X선영상증배관의 상대변환계수 측정에 관한 검토 (The Study on Measurement of Relative Conversion Factor in X-ray Image Intensifier)

  • 김성철;신성일;이선숙;허준;김성수
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제20권2호
    • /
    • pp.28-33
    • /
    • 1997
  • For the Evaluation of X-ray image intensifier, we measured radiation dose at input of I. I., brightness and fluorescence at output of I. I. by using X-ray exposure meter, optometer and fluorescence meter for the relative conversion factor. Especially, by using fluorescence meter, we could easily get relative conversion factor without having regulated machine by JIS. Since using, the quality of image intensifier is going down. Consequently, it needs continuous quality maintenance.

  • PDF

Posterior reversible encephalopathy syndrome related to anemia correction in a patient with uterine myoma: a case report

  • Lee, Jisun;Lee, Hyun Jung
    • Journal of Yeungnam Medical Science
    • /
    • 제39권4호
    • /
    • pp.336-340
    • /
    • 2022
  • Although posterior reversible encephalopathy syndrome (PRES) is induced by various causes, a few cases have occurred after severe anemia correction. In this case report, a 45-year-old female patient visited emergency department with a chief complaint of dizziness due to severe anemia related to hypermenorrhea caused by uterine myoma. Before her operation, she had an abrupt headache and seizure during anemia correction with transfusion and injection of gonadotropin-releasing hormone agonist. Immediately after the operation, she experienced visual disturbances, followed by limb weakness and tonic-clonic movements. Magnetic resonance imaging showed alterations in parietal and occipital lobes suggesting cerebrovascular edema with hypoperfusion. Here, we presented and discussed the clinical and radiologic features of PRES related to anemia correction.

국산 이중에너지 방사선흡수 골밀도 장치와 GE Lunar Prodigy의 교차분석 식 도출에 관한 연구 (Cross-Calibration of Domestic Devices and GE Lunar Prodigy Advance Dual-Energy X-Ray Densitometer Devices for Bone Mineral Measurements)

  • 김정수;노영훈;이인주;김경아;이인자;김정민
    • 방사선산업학회지
    • /
    • 제11권1호
    • /
    • pp.27-31
    • /
    • 2017
  • Reliable follow-up of bone mineral density (BMD) by dual energy X-ray absorptiometry (DXA) is essential in clinical practice. When there is a difference in the BMD values from DXA systems in the same patient, cross calibration equation is required for the reliable follow-up. Unfortunately, no equation is existed in BMD measure between GE Lunar Prodigy Advance (US, GE Healthcare; LPA) and Osteosys Dexxum T (Korea, Osteosys; ODT) DXA systems. In this study, we evaluate the agreement of BMD values between LPA and ODT and suggest the cross calibration equation using European spine phantom (ESP) with two systems. We performed BMD measurements using ten scans with ESP in each DXA systems. We compared BMD values and calculated cross calibration equation by linear regression analysis. The comparison between the LPA and ODT bone densitometers used the ESP. Compared to the ESP BMD values, ODT underestimated 14.36% and LPA overestimated 12.96%. The average of total BMD measurement values acquired with ODT were 21.44% lower than those from LPA. Cross-calibration equation for LPA and ODT was derived from ESP. We calculated simple cross calibration equation for LPA and ODT DXA systems. Cross-calibration equation is necessary for the reliable follow-up of BMD values in two different systems.

형광유리선량계의 계측 직선성 연구 (A Study on the Measurement Linearity of Photoluminescent Dosimeter)

  • 정경환;정동경;서정민
    • 한국방사선학회논문지
    • /
    • 제15권6호
    • /
    • pp.841-847
    • /
    • 2021
  • 방사선을 이용하는 관련 기관은 국내에 연구, 의료, 교육 등 다양하다. 최근에는 검진 및 의료기관의 방문 횟수가 증가하고 있다. 이로 인해 의료기관에서 방사선학적 검사 횟수가 증가하고 있다. 방사선작업종사자의 피폭뿐만 아니라 방사선 안전관리가 필요하다. 안전관리를 위해서 우선적으로 개인피폭선량계의 올바른 착용 및 착용 후 정확한 측정이 필요하다. 본 연구는 진단용 방사선발생장치의 방사선에 의한 PLD 소자의 계측 직선성을 평가하고 검증하려고 한다. 방사선 분할 조사 시간간격은 10, 30, 60 sec로 10회 조사와 거리에 따라 흡수선량 변화를 측정하기 위해서 조사거리를 30 ~ 100 cm까지 10 cm 간격으로 조사 후 측정하였다. 그 결과 시간 간격에 의한 흡수선량은 차이가 없었다. 이는 고흡수선량 연구에 진단용발생장치를 이용하여 다양한 연구에 도움이 될 것으로 여겨진다.

Transiting Nerve Rootlet Abnormalities on MRI after Lumbar Laminectomy: Associations with Persistent Postoperative Pain

  • Chankue Park;In Sook Lee;Kyoung Hyup Nam;You Seon Song;Tae Hong Lee;In Ho Han;Dong Hwan Kim
    • Korean Journal of Radiology
    • /
    • 제22권2호
    • /
    • pp.225-232
    • /
    • 2021
  • Objective: To determine whether changes in the transiting nerve rootlet or its surroundings, as seen on MRI performed after lumbar hemilaminectomy, are associated with persistent postoperative pain (PPP), commonly known as the failed back surgery syndrome. Materials and Methods: Seventy-three patients (mean age, 61 years; 43 males and 30 females) who underwent single-level partial hemilaminectomy of the lumbar spine without postoperative complications or other level spinal abnormalities between January 2010 and December 2018 were enrolled. Two musculoskeletal radiologists evaluated transiting nerve rootlet abnormalities (thickening, signal alteration, distinction, and displacement), epidural fibrosis, and intrathecal arachnoiditis on MRI obtained one year after the operations. A spine surgeon blinded to the radiologic findings evaluated each patient for PPP. Univariable and multivariable analyses were used to evaluate the association between the MRI findings and PPP. Results: The presence of transiting nerve rootlet thickening, signal alteration, and ill-distinction was significantly different between the patients with PPP and those without, for both readers (p ≤ 0.020). Conversely, the presence of transiting nerve rootlet displacement, epidural fibrosis, and intrathecal arachnoiditis was not significantly different between the two groups (p ≥ 0.128). Among the above radiologic findings, transiting nerve rootlet thickening and signal alteration were the most significant findings in the multivariable analyses (p ≤ 0.009). Conclusion: On MRI, PPP was associated with transiting nerve rootlet abnormalities, including thickening, signal alterations, and ill-distinction, but was not associated with epidural fibrosis or intrathecal arachnoiditis. The most relevant findings were the nerve rootlet thickening and signal alteration.

방사선사 업무의 발전에 관한 조사 연구 (Study on Development in Professional Work of Radiological Technologists)

  • 최종학;김창균;김원철;김승철
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제29권3호
    • /
    • pp.197-210
    • /
    • 2006
  • 방사선기술 분야는 비약적으로 확대되고 있고, 중앙화 집약화 표준화 전문화되고 있다. 이를 기반으로 하는 방사선사의 역할 및 업무영역은 해를 거듭할수록 더욱 고도화, 전문화되고 있음은 폭넓게 인정된 사실이다. 이 연구는 우리나라에서 방사선사와 관련한 면허제도, 교육, 전문적 업무, 법률의 변천과정과 실태 및 동향을 조사하고 분석하여, 향후 전문 직업으로서 방사선사의 발전 전략을 모색하고자 수행하였다. 조사한 자료를 분석 및 검토하여, 다음과 같은 결과를 얻었다. 방사선사의 국가면허 제도는 1965년부터 시작되었으며, $1965{\sim}1972$년에는 엑스선사(의료보조원), 1973년${\sim}$2006년 현재까지 방사선사(의료기사) 면허로 시행되었다. 방사선사 국가시험$(1965{\sim}2006년)$의 평균 합격률은 46.6%이었다. 앞으로 국가시험에서 시험방법, 시험과목, 문항 수준 등을 개선할 필요가 있다. 방사선사 양성 대학의 교육연한은 $1963{\sim}1990$학년도는 2년, $1991{\sim}1999$학년도는 3년, $2000{\sim}2006$학년도는 4년과 3년제로 운영되었다. 2006학년도 현재, 4년제 대학교 12개, 3년제 대학 18개이었고, 입학정원은 1,956명이었다. 의료와 과학의 발달에 따라, 방사선기술과학 교육의 발전적 패러다임을 구축해야 한다. 전문방사선사 제도는 2004년부터 민간자격(대한방사선사협회 주관)으로 운영하고 있으며, 앞으로 국가자격으로 발전시킬 필요가 있다. 방사선사와 의료인, 의료종사자 사이의 수직적, 수평적 관계를 법률 개정을 통해 재정립 하여야 한다. 특히, 의사 또는 치과의사의 의료기사에 대한 '지도' 권한은 '처방 또는 의뢰'로 개정하여야 한다. 의료현장에서 방사선사의 전문적 업무상황을 반영하여 '방사선사의 업무범위'를 확대하고, 업무범위를 규정한 의료기사 등에 관한 법률을 개정하여야 한다.

  • PDF

전산화단층촬영 검사 시 Gantry Aperture 내의 선량분포와 영상의 질 (Dose Distribution and Image Quality in the Gantry Aperture for CT Examinations)

  • 조평곤;김유현;최종학;이기열;김형철;김장섭;신동철;이성현;이준협;신귀순
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제32권4호
    • /
    • pp.453-460
    • /
    • 2009
  • 슬라이스 두께(slice thickness)와 선속시준(beam collimation, BC)의 변화에 따른 CT gantry aperture 내의 선량 분포와 영상의 질을 알아보고자 하였다. CT장치로는 64-slice MDCT 스캐너(Brilliance 64, Philips, Cleveland, USA)를 사용하였다. 피사체가 없는 경우(air scan)의 선량측정을 위해 CT용 전리함을 gantry aperture내의 회전중심점(isocenter)과 12시, 3시, 6시, 9시 방향에서 회전중심점으로부터 5 cm 간격으로 30 cm까지 BC를 변화시키면서 각각 측정 하였다. 또한 5개의 구멍(팬텀의 중심과 12시, 3시, 6시, 9시 방향)으로 구성된 CT head and body dose phantom을 gantry aperture 내에 위치시키고 각 지점에서 선량을 측정하였다. Gantry aperture 내 피사체의 위치변화에 대한 영상의 노이즈를 비교하기 위해서 AAPM CT용 팬텀의 물통을 회전중심점과 12시 방향으로 5 cm와 10 cm 이동시킨 후 BC를 변화시키면서 스캔한 후 팬텀의 중심과 12시, 3시, 6시, 9시 방향의 지점에서 노이즈를 측정하였다. 이 중에서 몇 군데의 위치는 영상 영역에서 벗어나서 측정 할 수가 없었다. 이때 노이즈 측정을 위해서 영상재구성의 슬라이스 두께는 5 mm로 하였다. 측정한 결과 다음과 같은 결론을 얻었다: 첫째, CTDIw는 회전중심점으로부터 멀어질수록, BC가 넓어질수록 감소하였다. 둘째, BC의 넓이가 비슷한 경우의 CTDIw는 거의 유사한 값을 보였다. 즉, CTDIw는 검출기 배열의 수나 화소의 크기 보다는 전체적인 BC의 넓이에 의존하고 있음을 알 수 있었다. 셋째, air scan과 phantom scan 경우 모두에서 CTDIw는 BC가 증가될수록 감소하였다. 그러나 air scan의 경우보다 head phantom scan 시 약 30%, body phantom scan 시 약 52% 정도 CTDIw의 값이 감소하였다. 넷째, BC와 팬텀의 위치 변화에 따른 노이즈 값은 $2{\times}0.5\;mm$의 BC을 제외하고는 head phantom scan한 경우 3.9~5.9, body phantom scan한 경우 5.3~7.4로 나타나, BC와 팬텀의 위치변화에 따라서 큰 차이가 없었다. 따라서 피사체의 위치가 gantry aperture 내 SFOV(scan field of view)에 포함될 경우 회전중심점에 정확하게 위치시키지 않아도 영상의 질에는 많은 영향을 미치지 않는다는 것을 알 수 있었다.

  • PDF

MEMS 가속도 센서를 이용한 환자 호흡동작 모니터링 체계 연구 (Study of the Respiratory Monitoring System by Using the MEMS Acceleration Sensor)

  • 성지원;윤명근;정원규;김동욱;신동오
    • 한국의학물리학회지:의학물리
    • /
    • 제24권1호
    • /
    • pp.61-67
    • /
    • 2013
  • 본 연구팀은 호흡 훈련을 통해 호흡의 안정성과 재현성을 증대시킴으로써 환자 적용 범위를 넓히고자 미세전자기계시스템(micro-electro-mechanical system, MEMs) 가속도 센서를 이용한 새로운 호흡훈련시스템을 개발하고자 한다. 본 연구는 호흡동작 모니터링의 선형연구로 MEMS 센서의 성능평가를 Respiratory Gating Platform (RGP)을 이용하여 2.5, 3.0, 3.5 s/cycle의 속도와 4.0, 3.0, 2.0 cm을 진폭으로 하는 1차원 왕복운동에 대한 MEMS 가속도 센서의 순간중력가속도에 대한 반응을 측정하였고 이를 Varian RPM (real time patient monitoring system) 시스템과 비교하였다. RGP의 운동 주기에 대한 MEMS 가속도 센서의 주기 오차는 0.6~6.0%로 측정되었으며 RPM 시스템과 MEMS 가속도 센서에 대한 진폭 감도오차는 1%와 3.6~11.5%로 측정 되었다. 본 연구를 통하여 MEMS 가속도 센서에 대한 환자 호흡 훈련용으로서의 가능성을 확인할 수 있었다.

디지털 의료영상에서 Edge method에 의한 Modulation Transfer Function 보정방법과 특이성 (Edge Profile Correction for Modulation Transfer Function on Digital X-ray Imaging System)

  • 김정민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제30권3호
    • /
    • pp.251-257
    • /
    • 2007
  • 디지털 MTF의 정확도를 결정하는 요소로는 정확한 엣지 각도의 결정, 합성 ESF 또는 합성 LSF을 작성을 위한 재 샘플링, 스무징, 커브핏팅 등을 들 수가 있다. 본 실험에서는 Edge를 이용한 MTF커브 핏팅방법을 구현하였고, 슬릿법에 의한 MTF산출결과와 비교하였다. 실험결과 공간주파수 2.0 LP/mm 근방까지의 저주파수영역에서는 엣지법이 높은 수치를 나타내며 2.0 LP/mm 이상의 주파수 영역에서는 MTF값이 역전이 되어 슬릿법이 더욱 높은 값을 나타내었다. 이는 Cunningham의 보고와 완전히 일치한다.

  • PDF

방사선 종사자 근무 분야별 피폭에 관한 검토 (Radiation Exposure According to Radiation Technologist' Working Departments)

  • 윤철호;윤석환;최준구
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제31권3호
    • /
    • pp.217-222
    • /
    • 2008
  • 본 논문은 2006. 1. 1${\sim}$12. 31(1년)까지 방사선 종사자 근무분야별 피폭에 관하여 서울시내 3차 의료기관인 A, B, C병원의 방사선 분야 종사자 방사선 피폭선량에 대한 분석 결과, 다음과 같은 결론을 얻었다. 1. 방사선 종사자 근무분야별 피폭은 심혈관조영실이 1.41mSv로서 제일 많았고, 방사선종양학과는 0.64mSv로서 제일 낮았다. 2. 방사선 종사자 근무분야별 피폭선량은 시술건수에 비례하였다. 3. 방사선 종사자 근무분야별 시술건수 당 피폭선량은 심혈관조영실 근무자가 많았고, 영상의학과 근무자는 적은 것으로 나타났다. 4. 방사선 종사자 근무분야별 피폭선량 순위는 심혈관조영실, 핵의학과, 영상의학과, 방사선종양학과의 순이었다. 이상과 같은 결과로 볼 때, 국제방사선방어위원회(ICRP) 권고안 범위이내이므로 병원 방사선 종사자들의 피폭에 따른 유해는 없는 것으로 판단되었다.

  • PDF