• Title/Summary/Keyword: Radiographic testing

Search Result 72, Processing Time 0.027 seconds

Maxillary Sinusitis by Staphylococcus aureus Infection in a Thoroughbred Gelding: Case Report

  • Lee, Sang Kyu;Lee, Inhyung
    • Journal of Veterinary Clinics
    • /
    • v.38 no.5
    • /
    • pp.225-230
    • /
    • 2021
  • A 4-year-old gelding Thoroughbred racehorse, which had been undergoing antibiotic therapy at a local veterinary clinic, was referred to the KRA veterinary center with a 20-day history of continuous right nasal discharge. Patient's history, endoscopic examination, and radiographic examination revealed primary maxillary sinusitis. Under sedation, surgical intervention was performed to collect samples and remove the accumulated mucopurulent exudate in the sinus. Swab samples were collected from the sinus during surgery for cytology and antimicrobial susceptibility testing. Only one type of bacteria was cultured, and molecular analyses of 16S ribosomal RNA gene sequences identified it as Staphylococcus aureus (S. aureus). The isolate was resistant to multiple antibiotics, which are frequently used in equine practice. Trimethoprim-sulfamethoxazole was chosen based on antibiotic susceptibility test, trephination, and sinus lavage using saline were applied to treat bacterial sinusitis. The clinical signs improved after 1 month and the patient resumed training. This report describes S. aureus isolated from bacterial maxillary sinusitis in a horse and its antibiotic susceptibility.

Are Magnetic Resonance Imaging Findings of Ankle Instability Always Correlated with Operative and Physical Examination Findings? (외측 인대 손상의 자기공명영상 소견들이 수술 소견 및 신체검사와 항상 일치할까?)

  • Park, Hyun-woo
    • Journal of Korean Foot and Ankle Society
    • /
    • v.25 no.1
    • /
    • pp.1-5
    • /
    • 2021
  • Physical examination and surgical findings and symptoms are often inconsistent with magnetic resonance imaging (MRI) findings when diagnosing chronic ankle lateral ligament instability, and confirmed surgical findings are used as the gold standard in most clinical studies. Anterior drawer testing is considered unreliable because normal findings are highly variable, and its accuracy ranges from 50% to 100%. Furthermore, radiographic stress imaging, such as in anterior drawer stress view, is performed under manual stress or using a stress device, and its findings also vary widely and confuse when interpreting stress views. The average accuracy of MRI findings is around 85% (range, 66%~91.7%), and thus, cannot be used as a primary indicator for surgery. For patients with suspected lateral ankle ligament instability, based on symptoms and physical examination findings, MRI may be useful for identifying lesions in ankle joints and for differentiating them from other conditions.

Comparison of Multi-Label U-Net and Mask R-CNN for panoramic radiograph segmentation to detect periodontitis

  • Rini, Widyaningrum;Ika, Candradewi;Nur Rahman Ahmad Seno, Aji;Rona, Aulianisa
    • Imaging Science in Dentistry
    • /
    • v.52 no.4
    • /
    • pp.383-391
    • /
    • 2022
  • Purpose: Periodontitis, the most prevalent chronic inflammatory condition affecting teeth-supporting tissues, is diagnosed and classified through clinical and radiographic examinations. The staging of periodontitis using panoramic radiographs provides information for designing computer-assisted diagnostic systems. Performing image segmentation in periodontitis is required for image processing in diagnostic applications. This study evaluated image segmentation for periodontitis staging based on deep learning approaches. Materials and Methods: Multi-Label U-Net and Mask R-CNN models were compared for image segmentation to detect periodontitis using 100 digital panoramic radiographs. Normal conditions and 4 stages of periodontitis were annotated on these panoramic radiographs. A total of 1100 original and augmented images were then randomly divided into a training (75%) dataset to produce segmentation models and a testing (25%) dataset to determine the evaluation metrics of the segmentation models. Results: The performance of the segmentation models against the radiographic diagnosis of periodontitis conducted by a dentist was described by evaluation metrics(i.e., dice coefficient and intersection-over-union [IoU] score). MultiLabel U-Net achieved a dice coefficient of 0.96 and an IoU score of 0.97. Meanwhile, Mask R-CNN attained a dice coefficient of 0.87 and an IoU score of 0.74. U-Net showed the characteristic of semantic segmentation, and Mask R-CNN performed instance segmentation with accuracy, precision, recall, and F1-score values of 95%, 85.6%, 88.2%, and 86.6%, respectively. Conclusion: Multi-Label U-Net produced superior image segmentation to that of Mask R-CNN. The authors recommend integrating it with other techniques to develop hybrid models for automatic periodontitis detection.

Tibial Tuberosity Advancement for Partial Rupture of Cranial Cruciate Ligament in Two Dogs (경골조면 전이동술을 이용한 개에서의 부분 전십자인대 단열치료 2례)

  • Heo, Su-Young;Lee, Hae-Beom
    • Journal of Veterinary Clinics
    • /
    • v.31 no.2
    • /
    • pp.141-144
    • /
    • 2014
  • Two dogs (Case 1 weighing 27 kg, Case 2 weighing 42 kg) were referred with hindlimb lameness. On physical examination, there was moderate pain on stifle joint testing and mild cranial translation on cranial drawer testing in Case 1. This translation was obvious when the patient was under general anesthesia. Case 2 showed discomfort during hyperextension of the stifle joint, but no significant cranial translation under general anesthesia. Joint effusion was detected on radiography in both cases. Based on physiologic and radiographic examinations, cranial cruciate deficiency was suspected, so exploratory arthroscopy was performed. Arthroscopy revealed partial rupture of the cranial cruciate ligament (CrCL) in both cases. Case 1 showed unstable partial CrCL rupture, while Case 2 had stable CrCL rupture. Tibial tuberosity advancement (TTA) was carried out as planned. Seroma occurred one week postoperatively in Case 2, and was removed surgically. The patients returned to satisfactory weight-bearing ambulation 5 months after initial surgery. Based on the results of these cases, TTA appears to be a useful procedure in the treatment of CrCL partial rupture.

The Optimization of NDT Method for Real Time X-ray Imaging (X선 실시간 영상장치를 이용한 비파괴시험 조건 최적화 연구)

  • Na, Sung-Youb;Choi, Yong-Kyu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.16 no.1
    • /
    • pp.19-28
    • /
    • 1996
  • This study has investigated the optimization of NDT method and the minimum detectable defect size for complex structures such as the solid propellant rocket motor using real time X-ray imaging system. Test specimens were made of steel plates with various defect size, and installed with proper thickness for which solid propellant, rubber, and case converted to the steel equivalent thickness according to the radiographic equivalent theory. As the results, this examination obtained optimum magnification and X-ray energy, dose rate according to steel equivalent thickness, also, obtained the relationship between minimum detectable defect size and the ratio(defect depot/object thickness). Thus, this simulated test is the preliminary procedure before performing NDT for real objects, and is possibly applied for NDT of other complex structures.

  • PDF

Development of Radiometric Scanning System for the Evaluation of the Pipeline (배관 검사용 Radiometric Scanning System 제작 및 시험)

  • Kim, Yong-Kyun;Hong, Seok-Boong;Chung, Chong-Eun;Lee, Yoon-Ho;Jung, Yong-Ha;Lee, Jeong-Ki
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.5
    • /
    • pp.474-482
    • /
    • 2002
  • One dimensional Radiometric scanning system was fabricated and tested as a filmless radiographic inspection system, which could be applied to the evaluation of the corrosion and deposits in the pipeline. This system is composed of the single radioactive source of the collimated focusing beam, and single scintillation detector of BGO, and the mechanical scanning system to transport and align the source and detector, and the operating software to automatically control the mechanical scan system. The performance of the system was simulated using GEANT4 software. This system is applied to one specimen having an artificial falw(flat bottom hole) in the pipe and the other specimen with thickness variation. For the inspection by using the radioactive source in the pipeline, it is possible to evaluate the corrosion and deposits in real time and without film.

Diagnosis and Monitoring of Socket Welded Pipe Damaged by Bending Fatigue Using Acoustic Emission Technique (음향방출법을 이용한 굽힘피로 손상된 소켓용접배관의 진단 및 감시)

  • Kim, C.S.;Oh, S.W.;Park, Ik-Keun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.4
    • /
    • pp.323-330
    • /
    • 2008
  • High cycle bending fatigue of socket welded small bore pipe was characterized, and also the fatigue crack initiation of small bore pipe was monitored in situ by the acoustic emission (AE) technique. The STS 316L stainless steel specimens were prepared by gas tungsten arc welding (GTAW) process having the artificial defect (i.e., lack of penetration) and defect free at the root. The fatigue failure was occurred at the loc for high stress and root for relatively low stress. The crack initiation cycles ($N_i$) was defined to the abrupt increase in AE counts during the fatigue test, and then the cracks were observed by the radiographic test and electron microscope before and after the fatigue crack initiation cycles. The socket welded pipe damaged by bending fatigue was studied regarding the welding defect, failure mode, and crack initiation cycles for the diagnosis and monitoring.

Evaluation of the Integrity of TIG Welding Using Non-Contact SH-EMAT (비접촉 SH-EMAT을 이용한 TIG용접부 건전성 평가)

  • Park, Tae Sung;Park, Yeong Hwan;Park, Ik Keun
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.25 no.1
    • /
    • pp.48-53
    • /
    • 2016
  • An EMAT can be used to reliably detect defects as it serves as a non-contact transducer with the ability to transmit ultrasonic waves into specimens without couplant. Moreover, an EMAT can easily generate desired waves by altering the design of the coil and magnet. This study proposes an SH-EMAT to evaluate the integrity of the TIG welding part. A stainless steel was welded using the TIG welding method. The welding current was varied to create artificial defects. Both the PA-UT and the RT were applied to verify the defect size. The experimental results generated by using the EMAT were compared with those methods. The amplitude was observed to decrease with an increase in the defect size. These results confirmed that the presence of defects can be reliably detected by attenuation of signal amplitude. The results demonstrated that the proposed method is suitable for evaluating the integrity of TIG welding.

Endodontic treatment enhances the regenerative potential of teeth with advanced periodontal disease with secondary endodontic involvement

  • Kwon, Eun-Young;Cho, Yunjung;Lee, Ju-Youn;Kim, Sung-Jo;Choi, Jeomil
    • Journal of Periodontal and Implant Science
    • /
    • v.43 no.3
    • /
    • pp.136-140
    • /
    • 2013
  • Purpose: The aim of this study was to identify a role for endodontic intervention in enhancing the regenerative potential of the periodontal ligament when combined with periodontal treatment in seriously involved teeth with a secondary endodontic component. Methods: Patients who exhibited radiolucency extending to the periapical region, abnormal electric pulp testing values, and deep probing depth derived from primary periodontal disease with secondary endodontic involvement were included. Intentional root canal treatment was applied to those teeth in which the apical lesions were presumed to communicate with those of the periodontal lesion of the teeth that remained vital. In all three selected cases, regenerative periodontal therapy incorporating either bone graft or guided tissue regeneration was instituted 3 months after the endodontic intervention. Results: Remarkable enhancement in radiographic density was noticeable around the affected teeth as evidenced by changes in radiopacity. There was a significant reduction in the probing pocket depth and gain in the clinical attachment level. Chewing discomfort gradually disappeared from the commencement of the combined treatment. Conclusions: An intentional endodontic intervention may be a worthwhile approach for the sophisticated management of teeth suffering from serious attachment loss and alveolar bone destruction with concomitant secondary endodontic involvement.

A case of dystrophic calcification in the masseter muscle

  • Kim, Heon-Young;Park, Jung-Hyun;Lee, Jun-Bum;Kim, Sun-Jong
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.39
    • /
    • pp.31.1-31.5
    • /
    • 2017
  • Background: Dystrophic calcification can occur in any soft tissue with the absence of a systemic mineral imbalance and is often associated with trauma, infection, or inflammation. It is easily found in the site of the heart and skeletal muscles and rarely appears in the head and neck area. Case report: We present a rare case of multiple calcified masses in the left masseter muscle of a 26-year-old female with a history of trauma in the area. In computed tomography, multiple radiopaque masses were observed inside the left masseter muscle and blood test results were normal. The calcified masses were diagnosed as dystrophic calcification and removed by surgery without any complications. Conclusion: Different types of calcifications may occur in the cheek area, and they need to be distinguished from dystrophic calcification. Thorough clinical examination and history taking is required together with blood testing and radiographic examinations.