• Title/Summary/Keyword: Radiographic results

Search Result 1,333, Processing Time 0.033 seconds

Prevalence Of Radiographic Ankle Osteoarthritis (방사선적 족관절염의 유병율)

  • Moon, Woo-Nam;Lee, Kyung-Sang
    • Journal of Korean Foot and Ankle Society
    • /
    • v.5 no.1
    • /
    • pp.13-17
    • /
    • 2001
  • Objectives: This study was done to determine the prevalence of radiographic ankle osteoarthritis (OA) in Korean women with clinical primary ankle OA. Methods: This analysis involved 160 Korean women who visited our out patient clinic due to ankle joint pain. Ankle AP and lateral weight-bearing radiographs were evaluated retrospectively to check whether they have radiographic OA or not. Radiographs were read for features of ankle OA using School classification. Demographic factors and radiographic findings in both radiographic ankle OA group and non-radiographic ankle OA group were analyzed by the student t-test, the chi square test and the Pearson's analysis. A p value <0.05 was considered significant. Results: The prevalence of radiographic ankle OA in Korean women is 18.2 % in patient between 18 and 39 years and is 55.6 % in patient over 40. There was significant difference between two groups with age (P<0.001) and relatively strong correlation between radiographic OA and age (r=0.474, P<0.001). Conclusion: These results show that the prevalence of Korean women with radiographic changes of ankle OA was 45 % and there was relatively strong correlation between age and radiographic ankle OA.

  • PDF

The radiographic depth of approximal root cavities : A comparative study of conventional and digital radiographs (인접면 치근 인공우식병소의 깊이 평가: 구내 일반 방사선사진과 디지털 방사선사진과의 비교)

  • Park Hyun-Jung;Cho Bong-Hae
    • Imaging Science in Dentistry
    • /
    • v.33 no.1
    • /
    • pp.15-20
    • /
    • 2003
  • Purpose : To investigate the reproducibility of the conventional and digital radiographs to determine the depth of approximal root cavities. Materials and Methods : A total of 80 artificial root cavities were prepared in the approximal surfaces of premolars, maxillary and mandibular molars. Standardized radiographs were taken at the baseline (0° horizontal and 0° vertical) and at a horizontal angulation of 10° in both mesial and distal directions. Radiographic cavity depths were measured by both conventional and digital radiographs. Results: At 0° horizontal angulation, no statistically significant differences could be determined between the results of conventionally and digitally determined radiographic depths with respect to the actual cavity depths in all premolar, maxillary, and mandibular molar groups. All conventional and digital radiographic depths at both 10° mesial and distal angulations showed statistically significant increases in depth compared to the actual cavity depths (p < 0.05), with the exception of digital radiographic depth at 10° mesial angulation for premolars. There were no statistically significant differences between conventional and digital radiographic depths for all groups. Conclusion: The present study suggests that both conventional and digital radiographs provide reproducible assessment of the depth of the approximal root cavity. But horizontal X-ray beam movements are likely to result in increase in radiographic cavity depth.

  • PDF

Usefulness of the Oblique Radiographic View in Ankle Fractures (족근 관절 골절에서 사면상 단순 방사선 사진의 유용성)

  • Cho, Duck-Yun;Song, Sang-Jun;Yoon, Hyung-Ku;Han, Soo-Hong;Chang, Ji-Hoon;Yoon, Byung-Ho
    • Journal of Korean Foot and Ankle Society
    • /
    • v.9 no.1
    • /
    • pp.94-98
    • /
    • 2005
  • Purpose: To compare the radiographic evaluations between two radiographic views (AP and lateral views) and four radiographic views (AP, lateral and both oblique views) in ankle fractures. Materials and Methods: From January 2000 to June 2002, 60 cases of ankle fractures were treated with open reduction and internal fixation and its followed up periods were at least 2 years. All cases were classified into three groups according to the method of preoperative radiographic evaluation. Two radiographic views (AP and lateral views) were taken in group A and four radiographic views (AP, lateral and both oblique views) were taken in group B. 12 Cases were evaluated with three dimensional computed tomography (3D CT). Four radiographic views and 3D CT were taken in group C. All cases were classified according to the Danis-Weber and Lauge-Hansen classification. Displacement of fracture fragment of medial, lateral, posterior malleolus and size of fracture fragment of posterior malleous were measured using picture archiving communication system (PACS). Results: Although kappa value between two or four radiographic views were good or excellent in Danis-Weber classification and Lauge-Hansen classification of ankle fractures, the displacements of medial and lateral malleoli were statistically different. Four radiographic views evalulated the degree of displacement of medial and lateral fragments more accurately compared to two radiographic views. Conclusion: Four radiographic views will be more useful than two radiographic views to decide the method of treatment and operation considering the displacement of fracture fragment.

  • PDF

An Experimental Study of Radiographic Density of Alveolar Bone and Cortical Thickness of Mandible by Osteoporosis (골다공증에 따른 치조골 방사선사진농도와 하악하연두께의 변화에 대한 연구)

  • Lee Byeong-Do
    • Imaging Science in Dentistry
    • /
    • v.30 no.4
    • /
    • pp.235-242
    • /
    • 2000
  • Purpose: To evaluate the effect of the systemic osteoporosis on radiographic density of alveolar bone and cortical thickness of mandible. Materials and Methods: The bone mineral density values of lumbar and femur were measured by dual-energy X-ray absorptiometry and T scores of lumbar, femur were obtained respectively. Radiographic densities of alveolar bones and panorama mandibular index (PMI, represents as cortical thickness) were analysed statistically according to age and T score variables. Results: The radiographic density of alveolar bone of maxillary molar showed significant difference by age and femur T group. That of mandibular molar showed significant difference between femur T group. Panorama mandibular index showed significant difference between age groups. Conclusion: The radiographic density of alvealar bones was more dependent on age and femur T than lumbar T. Cortical thickness of mandible was correlated with increasing age.

  • PDF

EXPERIMENTAL STUDY OF INFLUENCE ON RADIOGRAPHIC DENSITY AND CONTRAST BY THE CHANGE OF KILOVOLTAGE AND EXPOSURE TIME (관전압과 X선노출시간의 변화가 X선사진의 흑화도와 대조도에 미치는 영향에 관한 실험적 연구)

  • Lee Byeong Do;Lee Sang Rae
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.20 no.1
    • /
    • pp.113-124
    • /
    • 1990
  • For the study of the influence of kilovoltage and exposure time on radiographic density and contrast, we measured radiographic density of aluminum step wedge which composed of contiguous 8 steps wedges of 2-16㎜ thickness with densitometer. Aluminum step wedge was radiographed on Kodak ultraspeed DF-58 and Ektaspeed EP-21 film with range of 60-90 kVp and 5-60 impulse and subject contrast of aluminum step wedge with constant radiographic density and image contrast percentage without radiographic density was evaluated. Then we evaluated the film quality of teeth and their surrounding structure according to the change of kVp and exposure time by score rating method. The obtained results were as follows: 1. Radiographic density was related to the change of kilovoltage, especially in increased exposure time. 2. With constant radiographic density, subject contrast of thin aluminum step wedges was greater in low kilovolt age than high kilovoltage, but kilovolt age had not great influence on subject contrast of thick aluminum step wedge. On the other hand, radiographic density difference between 2mm and 16mm aluminum step wedge was decreased according to in- creasing kilovoltage. 3. Without constant radiographic density, image contrast percentage was decreased with increasing kilovoltage, but was not related with the change of exposure time. 4. Radiographic contrast of teeth and their surrounding structure which was taken with the range of 60-90 kVp and 6-30 impulse had not great influence on film quality.

  • PDF

In vivo assessment of accuracy of Propex II, Root ZX II, and radiographic measurements for location of the major foramen

  • Tampelini, Fernanda Garcia;Coelho, Marcelo Santos;de Azevedo Rios, Marcos;Fontana, Carlos Eduardo;Rocha, Daniel Guimaraes Pedro;Pinheiro, Sergio Luiz;da Silveira Bueno, Carlos Eduardo
    • Restorative Dentistry and Endodontics
    • /
    • v.42 no.3
    • /
    • pp.200-205
    • /
    • 2017
  • Objectives: The aim of this in vivo study was to assess the accuracy of 2 third-generation electronic apex locators (EALs), Propex II (Dentsply Maillefer) and Root ZX II (J. Morita), and radiographic technique for locating the major foramen (MF). Materials and Methods: Thirty-two premolars with single canals that required extraction were included. Following anesthesia, access, and initial canal preparation with size 10 and 15 K-flex files and SX and S1 rotary ProTaper files, the canals were irrigated with 2.5% sodium hypochlorite. The length of the root canal was verified 3 times for each tooth using the 2 apex locators and once using the radiographic technique. Teeth were extracted and the actual WL was determined using size 15 K-files under a ${\times}25$ magnification. The Biostat 4.0 program (AnalystSoft Inc.) was used for comparing the direct measurements with those obtained using radiographic technique and the apex locators. Pearson's correlation analysis and analysis of variance (ANOVA) were used for statistical analyses. Results: The measurements obtained using the visual method exhibited the strongest correlation with Root ZX II (r = 0.94), followed by Propex II (r = 0.90) and Ingle's technique (r = 0.81; p < 0.001). Descriptive statistics using ANOVA (Tukey's post hoc test) revealed significant differences between the radiographic measurements and both EALs measurements (p < 0.05). Conclusions: Both EALs presented similar accuracy that was higher than that of the radiographic measurements obtained with Ingle's technique. Our results suggest that the use of these EALs for MF location is more accurate than the use of radiographic measurements.

Current status of dental intraoral imaging devices and radiographic safety management (치과 구내촬영 장비 현황과 방사선 안전 관리 실태 연구)

  • Kang, Eun-Ju;Hyeong, Ju-Hee
    • Journal of Korean society of Dental Hygiene
    • /
    • v.16 no.2
    • /
    • pp.205-214
    • /
    • 2016
  • Objectives: The purpose of the study is to investigate the current status and radiographic safety management in Korea. Methods: A self-reported questionnaire was completed by 200 dental hygienists in Jeonbuk province from September 1, 2014 and October 31, 2014. The questionnaire consisted of general characteristics of the subjects, radiation knowledge, radiation safety management, and radiation exposure anxiety. Data were analyzed using SPSS 18.0 program. Results: Duration of clinical experience(r=0.142) and number of daily radiation shot(r=0.145) showed a positive correlation to radiation safety management, and a nrgative correlation to use of intraoral films and digital devices(r=-0.587). A logistic regression analysis was performed in order to evaluate the influence on radiography knowledge. The results showed that the factors had significant influences on the age group over 41 years old(OR 7.25; 95% CI 1.30-40.43) and those who took a position above team leader(OR 0.23; 95% CI 0.59-0.90). Conclusions: It is very important to have the safety management toward dental intraoral imaging and radiograpgic shot in the dental hygienists. Continuous efforts should be emphasized on radiographic safety management and behavior.

When Do Clinical and Radiographic Results Stabilize after Proximal Chevron Osteotomy in Hallux Valgus? (무지외반증에 대한 근위 갈매기형 절골술 시행 후 임상적 및 방사선학적 결과는 언제 안정화되는가?)

  • Park, Chul Hyun;Lee, Woo Chun;Park, Jae Woo;Moon, Jeong Jae
    • Journal of Korean Foot and Ankle Society
    • /
    • v.19 no.3
    • /
    • pp.91-96
    • /
    • 2015
  • Purpose: The purpose of this study is to evaluate the sequential changes of clinical and radiographic results after proximal chevron osteotomy in patients with moderate to severe hallux valgus. Materials and Methods: Between January 2008 and December 2009, 93 patients (117 feet) were treated with proximal chevron osteotomy and distal soft tissue procedure for symptomatic moderate to severe hallux valgus deformity. The mean age of patients was 51 years (range, 19 to 71) and the mean duration of follow-up was 27.5 months (range, 24 to 35). Clinical results were evaluated using visual analogue scale (VAS) and American Orthopaedic Foot and Ankle Society (AOFAS) score preoperatively, at 3, 6, and 12 months after surgery, and at the last follow-up. Radiographic parameters including hallux valgus angle, intermetatarsal angle, and sesamoid position were evaluated preoperatively, immediately postoperatively, at 6 weeks, at 3, 6, and 12 months after surgery, and at the last follow-up. Results: VAS and AOFAS score showed significant improvement until 12 months after surgery. Hallux valgus angle and sesamoid position stabilized at 12 months after surgery and intermetatarsal angle stabilized at 6 months after surgery. Conclusion: Clinical and radiographic results were stabilized beyond 12 months after proximal chevron osteotomy in patients with moderate to severe hallux valgus.

Evaluation of dental panoramic radiographic findings in edentulous jaws: A retrospective study of 743 patients "Radiographic features in edentulous jaws"

  • Kose, Taha Emre;Demirtas, Nihat;Karabas, Hulya Cakir;Ozcan, Ilknur
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.5
    • /
    • pp.380-385
    • /
    • 2015
  • PURPOSE. The aim of this study was to determine the frequency of significant panoramic radiographic findings and eventual treatment requirements before conventional or implant supported prosthetic treatment in asymptomatic edentulous patients. MATERIALS AND METHODS. A total of 743 asymptomatic edentulous patients were retrospectively evaluated using a digital panoramic system. We analyzed the radiographic findings, including impacted teeth, retained root fragments, foreign bodies, severe atrophy of the posterior maxillary alveolar bone, mucous retention cysts, soft tissue calcifications and radiopaque-radiolucent conditions. RESULTS. Four-hundred-eighty-seven (65.6%) patients had no radiographic finding. A total of 331 radiographic findings were detected in 256 (34%) patients. In 52.9% (n=175) of these conditions, surgical treatment was required before application of implant-supported fixed prosthesis. However, before application of conventional removable prosthesis surgical treatment was required for 6% (n=20) of these conditions. CONCLUSION. The edentulous patients who will have implant placement for implant-supported fixed prosthesis can frequently require additional surgical procedures to eliminate pathological conditions.

Clinical Significance of Lateral Ankle Radiograph after the Reduction of a Syndesmosis Injury (원위경비인대결합 손상 정복 후 관찰된 측면 방사선 영상의 임상적 중요성)

  • Suh, Jae Wan;Park, Hyun-Woo
    • Journal of Korean Foot and Ankle Society
    • /
    • v.21 no.4
    • /
    • pp.128-134
    • /
    • 2017
  • Purpose: To introduce reliable and newly developed radiographic measures based on a lateral ankle radiograph to assess a syndesmotic reduction after screw fixation and to compare with the radiographic measures based on the anteroposterior (AP) and mortise radiographs. Materials and Methods: The postoperative ankle radiographs of 34 ankle fracture cases after screw fixation for concurrent syndesmosis injury were reviewed. Two radiographic parameters were measured on each AP and mortise radiograph; tibiofibular clear space (TFCS) and tibiofibular overlap (TFO). Five radiographic parameters were measured on the true lateral radiographs; the anteroposterior tibiofibular (APTF) ratio, anterior tibiofibular ratio (ATFR), posterior tibiofibular ratio (PTFR), distances of intersection of the anterior fibular border and the tibial plafond to anterior cortex of the tibia (AA'), and the intersection of posterior fibular border and tibial plafond to the tip of the posterior malleolus (BB'). In addition, the distance (XP) between the fibular posterior margin (X) crossing tibial plafond or the posterior malleolus and posterior articular margin (P) of the tibial plafond was measured on the lateral view. Results: Using TFCS and TFO in the AP and mortise radiographs, malreductions of syndesmosis were estimated in 17 of 34 cases (50.0%). Using the introduced and developed radiographic measures in the lateral radiographs, syndesmotic malreductions were estimated in 16 out of 34 cases (47.1%). Seventeen cases (50.0%) showed no evidence of postoperative diastasis using the radiographic criteria on the AP and mortise view, 10 cases (58.8%) of whom showed evidence of a malreduction on the lateral radiograph. The newly developed measurements, XP, were measured 0 in 11 out of 34 cases (32.4%). Conclusion: The reduction of syndemosis after screw fixation can be accurately assessed intraoperatively with a combination of several reliable radiographic measurements of the lateral radiograph and traditional radiographic measurements of the AP and mortise radiograph.