• 제목/요약/키워드: Radiographic inspection

검색결과 41건 처리시간 0.026초

ATOS 80 고장력강의 용접 패스에 따른 용접부 방사선검사에 관한 연구 (A Study on the Radiograph Inspection of Specimen in Welding Pass Using ATOS 80 High-strength Steel)

  • 백정환;최병기
    • 한국생산제조학회지
    • /
    • 제21권6호
    • /
    • pp.915-919
    • /
    • 2012
  • In constructing all kinds of equipment and steel structure, parts with discontinuities such as weld defects formed in the welded structure can generate fatigue cracks that results in damage or accidents. In this study, weld zones are investigated with X-rays and the latent images are put on film. Weld zone defects can be verified by developing the film. As weld defects are investigated by radiographic testing and correlated with the welding condition, more appropriate welding conditions can be found. According to the result of X-ray radiographic inspection of butt welding ATOS 80 high-strength steel with a thickness of 12mm, the best conditions for welding without creating weld defects are 4 weld-passes, a protective gas of 20% $CO_2$ and 80% Ar, a protective gas flow of 20L/min, a welding current of 200A, an arc voltage of 24V, a welding speed of 14.4cm/min, a welding rod angle of $50^{\circ}$, a welding gap of 5 mm with a ceramic base, and sand pre-heating to $160^{\circ}$ Celsius prior to welding.

초음파 다중 반사를 이용한 추진제/라이너 미접착 검출 기법 연구 (Inspection Technology of Detection of Propellant/Liner Debond Using Ultrasonic Multi-reflection)

  • 나성엽;김동륜;류백능
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2007년도 제28회 춘계학술대회논문집
    • /
    • pp.17-21
    • /
    • 2007
  • 초음파를 이용한 로켓 모타의 비파괴검사는 X-ray 검사에 비하여 경제성이 우수하고, 미접착 등의 결함 검출이 우수한 편이다. 그리고 전용 시설 없이 현장에서 실시간으로 검사가 가능하며 방사선 작업에 비하여 안전한 방법이다. 본 논문에서는 초음파 다중반사에 의한 추진제/라이너 미접착 검출 기법에 대하여 실험 및 이론적 모델링으로 분석하였다. 실험 결과, 추진제/라이너 미접착의 신호가 정상 접착과 구별되는 뚜렷한 신호 차이를 보였으며, 실험에서 측정한 신호와 이론적 모델링 신호가 대체적으로 일치하였다.

  • PDF

한국 의료기관의 방사선 영상검사 평가 현황 및 과제 (A Study on the Status and Improvement Direction of Radiographic Imaging Examination Assessment in Korea Medical Institutions)

  • 조영권
    • 한국방사선학회논문지
    • /
    • 제17권4호
    • /
    • pp.565-572
    • /
    • 2023
  • 본 연구에서는 국내 공공 부문에서 실시하고 있는 의료기관 평가 중 영상검사와 관련된 현황을 살펴보고 개선 방향을 제시하고자 하였다. 의료기관 평가 중 영상검사와 관련된 주요 평가는 의료기관 인증평가와 영상검사 적정성 평가가 있으며, 의료기관 인증평가에서는 영상검사 운영과정, 정확한 결과 제공, 안전관리 절차 준수 등을 평가하고 있다. 영상검사 적정성 평가에서는 인력, 장비와 관련된 구조 지표, 환자평가 실시율, 피폭 저감 프로그램 등이 포함되어 있었다. 하지만 좀 더 안전하고 질 높은 영상검사를 위해서는 의료기관의 인증평가 참여율을 높이는 방안 마련이 필요하며, 영상검사 적정성 평가의 인력지표 개선과 인센티브 지급에 대한 고려도 필요하다. 마지막으로 국가 차원의 방사선 노출 통합관리도 함께 병행되어야 할 것이다.

Spontaneous Anterior Cerebral Artery Dissection Presenting with Simultaneous Subarachnoid Hemorrhage and Cerebral Infarction in a Patient with Multiple Extracranial Arterial Dissections

  • Park, Yung Ki;Yi, Hyeong-Joong;Lee, Young Jun;Kim, Young-Seo
    • Journal of Korean Neurosurgical Society
    • /
    • 제53권2호
    • /
    • pp.115-117
    • /
    • 2013
  • Simultaneous subarachnoid hemorrhage and infarction is a quite rare presentation in a patient with a spontaneous dissecting aneurysm of the anterior cerebral artery. Identifying relevant radiographic features and serial angiographic surveillance as well as mode of clinical manifestation, either hemorrhage or infarction, could sufficiently determine appropriate treatment. Enlargement of ruptured aneurysm and progressing arterial stenosis around the aneurysm indicates impending risk of subsequent stroke. In this setting, prompt treatment with stent-assisted endovascular embolization can be a reliable alternative to direct surgery. When multiple arterial dissections are coexistent, management strategy often became complicated. However, satisfactory clinical results can be obtained by acknowledging responsible arterial site with careful radiographic inspection and antiplatelet medication.

경사조사(傾斜照射) 강판튜브 방사선 관측영상의 수직 방향 공간분석 (Vertical Space Analysis for Gradient Radiating Steel-tube Radiographic Image)

  • 황중원;황재호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.29-31
    • /
    • 2007
  • In this paper we propose an directional analytic approach in image data space for X-ray image which is detected from the X-ray projection system. Such a radiographic nondestructive testing has long been used for steel-tube inspection and weld monitoring. The welded area and thickness of steel-tube are detected from gradient radiating mechanism based on the evaluation of biased X-ray source position. The welded area is an ellipse type on low contrast X-ray image including noise. Noise originates from most of elements of the system. such as shielding CCD camera, imaging screen, X-ray source, inspected object, electronic circuits and etc.. Projection incorrectness and noise influence on imaging quality is to be represented by vertical pixels' distribution. Space analysis due to vertical direction also shows the segmental possibility between regions by visual edge evaluation.

  • PDF

강판튜브 엑스선 영상의 영역별 영상잡음 특성분석 (Regional Image Noise Analysis for Steel-tube X-ray Image)

  • 황중원;황재호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.32-34
    • /
    • 2007
  • The X-ray projection system has long been used for steel-tube inspection and weld monitoring. The thickness of tubes and welded areas is based on the evaluation of radiographic shadow projections. The traditional tangential measurement estimates the distance of border lines of the projected wall shadows of a tube onto a radiographic image detector. The detected image in which although there is a variety of noise may be sectioned into several partitions according to its specific blocks. Imaging noise originates from most of elements of the system, such as shielding CCD camera, imaging screen, X-ray source, inspected object, electronic circuits and etc. The tangential projection incorrectness and noise influence on imaging quality. In this paper we first sectionalize the X-ray image on the basis of vertical contrast difference. And next functional and statistic analysis are carried on at each region. Geometrical distance and unsharpness of the edge caused by visual evaluation uncertainties are also discussed.

  • PDF

초음파를 이용한 고체 추진제 추진기관의 결함 검출 기법 (Ultrasonic Inspection Technology of Defect Detection of Solid Propellant Rocket Motor)

  • 나성엽
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2006년도 제26회 춘계학술대회논문집
    • /
    • pp.239-245
    • /
    • 2006
  • 초음파를 이용한 추진기관의 비파괴검사는 X-ray 검사에 비하여 경제성이 우수하고, X-ray 검사시 취약한 dis-bond, damage 등의 결함 검출이 우수한 편이다. 그리고 전용시설의 필요없이 현장에서 실시간으로 검사가 가능하며 방사선 작업에 비하여 안전한 방법이다. 본 논문에서는 고체 추진제에 대한 초음파 특성을 분석하고, 추진제/라이너 미접착에 대한 내측과 외측 검사 방법 및 추진제 damage에 의한 미세 크랙검출에 대하여 실험 및 분석하였다. 실험 결과, 추진제에서의 초음파 감쇠는 $6\sim8db/cm$로 비교적 큰 감쇠를 보였으며 추진제/라이너 미접착에 대한 내 외측 검사에 있어서도 제한된 조건이지만 검출 가능성을 보였다. 그리고 damage에 의한 추진제 미세 크랙도 초음파의 감쇠특성을 이용하여 검출 가능함을 보였다.

  • PDF

Film Radiography에서 농도차를 이용한 정량적 두께 평가에 관한 연구 (A Study on Quantitative Thickness Evaluation Using Film Density Variation in Film Radiography)

  • 이성식;이정기;김영환
    • 비파괴검사학회지
    • /
    • 제19권5호
    • /
    • pp.356-362
    • /
    • 1999
  • 공업용 방사선 필름의 필름 농도가 대략 3.5 이하의 농도 구간에서 상대 노출에 대해 지수 함수적으로 증가한다고 가정하여, 필름특성곡선에 관한 일반식과 두께 변화에 대한 농도 변화 관계식을 새로이 제안하였다. 연속 X-선과 $Ir^{192}$에 의한 ${\gamma}$-선으로 탄소강의 계단시편에 대해 시험한 결과, 대략 $1.0{\sim}3.5$의 농도 범위에서 두께 변화에 대한 농도의 상용 대수변화가 기존의 관계식에 비해 보다 선형적인 경향을 나타내었으며 실제 계단 시편의 치수와 제안한 관계식에 의한 평가를 비교한 결과 본 연구에서 제안한 농도-두께 관계식에 의한 결과가 기존의 관계식에 의한 결과보다 정확하였다. 그리고 시험체의 두께가 증가함에 따라 beam hardening effect에 의해 유효선흡수계수가 달라지는 연속 X-선에 비해 상대적으로 에너지 스펙트럼이 단순한 ${\gamma}$-선이 두께 평가를 위한 더 적합한 방사선원임을 확인하였다. 본 연구에서 제안한 관계식은 국부적인 부식 손상의 깊이와 분포도를 평가할 수 있으므로 압력 용기 등의 산업 설비의 건전성 평가에 활용할 수 있다.

  • PDF

3D 프린터 필라멘트 재료를 이용한 야외 방사선투과검사용 차폐체 개발을 위한 연구 (Study on the Development of an Outdoor Radiographic Test Shield Using 3D Printer Filament Materials)

  • 문익기;신상화
    • 한국방사선학회논문지
    • /
    • 제13권4호
    • /
    • pp.565-572
    • /
    • 2019
  • 본 연구에서는 야외 방사선투과검사 시 방사선작업종사자의 맞춤형 차폐체 제작을 위해 3D 프린터 필라멘트의 재질 및 두께에 대한 차폐 분석을 수행하였다. MCNPX를 이용한 모의 모사를 통해 복셀 선원 $^{192}Ir$, $^{75}Se$를 선택 후 ICRU Slab Phantom에 차폐체를 부착하고, 선원과 Slab Phantom의 거리를 100 cm으로 설정하였다. 12 개의 차폐물질에 대하여 차폐물질이 없는 경우부터 200 mm 까지 5 mm 단위로 나누어 각 차폐물질별 단위 질량 당 흡수되는 에너지를 평가하였다. 그 결과 모든 방사선투과검사용 감마선원에서 ABS + Tungsten, ABS + Bismuth, PLA + Copper, PLA + Iron 순으로 차폐 효과가 높은 것으로 나타났다. 그러나 납에 비해서는 다소 낮은 차폐 효과를 보였다. 향후 본 연구를 토대로 원자번호와 밀도가 높은 필라멘트 재료에 대한 추가적인 연구가 필요할 것으로 판단된다.

보온재 부착 파이프라인의 부식두께 측정에 관한 연구 (A Study on Real-Time Corrosion Thickness Measurement Technique of Insulated Pipeline)

  • 장지훈;조경식;이종오;김기동
    • 연구논문집
    • /
    • 통권31호
    • /
    • pp.135-147
    • /
    • 2001
  • The wall-thickness of insulated pipelines can be easily evaluated by measuring the gamma-ray transmission intensity because this intensity is inversely proportional to the thickness of insulated pipeline. The main purpose of this study is to develop the nondestructive and filmless on-line inspection system of corrosion by measuring the wall thickness of insulated pipeline. The inspection system is constructed with radioisotope, 64 channel photo diode array detector, crawler system and data taking and operating software. The traditional off-line radiographic method carried out by exposing film cassettes can be replaced by this cost-effective on-line digital imaging method and the application will be greatly expected especially in the chemical and petrochemical industries.

  • PDF