• 제목/요약/키워드: Radiographic film

검색결과 122건 처리시간 0.024초

방사선투과사진에 의한 결함깊이 및 높이의 평가 (Estimation of Flaw Depth and Height by Radiography)

  • 강계명;박은수;심언덕
    • 한국재료학회지
    • /
    • 제12권8호
    • /
    • pp.682-687
    • /
    • 2002
  • The three-dimensional estimation on the depth and height of flaw by using the difference of radiographic contrast density was studied. First, the specimens having artificial flaws of various depths and heights were prepared and the radiographic testing was performed. The radiographic depth of flaw was investigated and estimated on the effect of the scattered radiation with the change of distance between flaw and film. The height of flaw was estimated from the radiographic test with the reference specimen. The radiographic contrast with flaw depth decreased with increasing the flaw depth. The scattered radiation increased with increasing flaw depth and varied with the location between flaw and film. However, in the case of flaw height, the contrast density increased with increasing flaw height. It is thought due to the change in volume generating the scattered radiation which reaches a film.

Kodak Insight 치과필름의 특성에 관한 연구 (Study on the characteristics of Insight dental x-ray film)

  • 송영한;이완;이병도
    • Imaging Science in Dentistry
    • /
    • 제33권1호
    • /
    • pp.21-26
    • /
    • 2003
  • Purpose: To investigate the characteristics of the newly marketed, Insight dental X-ray film. Materials and Methods: Kodak Ultraspeed (DF-58), E-speed, Agfa Dentus M2, and Kodak Insight (IP-21) films were radiographed using a Trophy intra-oral radiographic machine. 10 step exposure times were prepared and each step exposure was monitored using a FH 40G (ESM Eberline Instruments) dosimeter for each of the 4 types of intra-oral film. All films were manually processed and the radiographic densities at 6 sites of each processed film were measured, and the characteristic curves of each of the 4 types intra-oral films were created utilizing these dosimetric data and radiographic densities, based on ISO 5779. The film contrast, speed, and base plus fog density of Insight film were compared with those of the 3 other films examined in this experiment. Results : E-speed film showed greatest average gradients followed by Insight film. E-speed and Ultraspeed film showed great average gradients at low density levels. Insight film showed the fastest speed followed by E-speed, Dentus M2 and Ultraspeed film. Dentus M2 film showed greatest base plus fog density level followed by Insight film. Conclusion : Kodak Insight film showed fastest film speed with comparable film contrast on characteristic curve.

  • PDF

관전압과 X선노출시간의 변화가 X선사진의 흑화도와 대조도에 미치는 영향에 관한 실험적 연구 (EXPERIMENTAL STUDY OF INFLUENCE ON RADIOGRAPHIC DENSITY AND CONTRAST BY THE CHANGE OF KILOVOLTAGE AND EXPOSURE TIME)

  • 이병도;이상래
    • 치과방사선
    • /
    • 제20권1호
    • /
    • pp.113-124
    • /
    • 1990
  • For the study of the influence of kilovoltage and exposure time on radiographic density and contrast, we measured radiographic density of aluminum step wedge which composed of contiguous 8 steps wedges of 2-16㎜ thickness with densitometer. Aluminum step wedge was radiographed on Kodak ultraspeed DF-58 and Ektaspeed EP-21 film with range of 60-90 kVp and 5-60 impulse and subject contrast of aluminum step wedge with constant radiographic density and image contrast percentage without radiographic density was evaluated. Then we evaluated the film quality of teeth and their surrounding structure according to the change of kVp and exposure time by score rating method. The obtained results were as follows: 1. Radiographic density was related to the change of kilovoltage, especially in increased exposure time. 2. With constant radiographic density, subject contrast of thin aluminum step wedges was greater in low kilovolt age than high kilovoltage, but kilovolt age had not great influence on subject contrast of thick aluminum step wedge. On the other hand, radiographic density difference between 2mm and 16mm aluminum step wedge was decreased according to in- creasing kilovoltage. 3. Without constant radiographic density, image contrast percentage was decreased with increasing kilovoltage, but was not related with the change of exposure time. 4. Radiographic contrast of teeth and their surrounding structure which was taken with the range of 60-90 kVp and 6-30 impulse had not great influence on film quality.

  • PDF

정상 해부학적 구조물에 대한 X-선 영상의 비교 연구 (A Comparative Study of Radiographic Images on Normal Anatomical Structures)

  • 최향희;최의환;김재덕
    • 치과방사선
    • /
    • 제29권1호
    • /
    • pp.283-297
    • /
    • 1999
  • Purpose: To compare radiographic images of Digora/sup (R)/ system and Ektaspeed Plus film obtained from normal adults. Materials and methods: Storage phosphor plate(SPP) was placed in a film holder behind Ektaspeed Plus film package without lead foil. The effect of film on SPP was studied in a separate in vitro experiment. Forty-seven sets of images were prepared for the evaluaton. The regions of interest(ROI) for evaluation were designated at seven sites including normal anatomical structures. The image quality for each ROI was evaluated on enhanced and unenhanced storage phosphor(SP) images and Ektaspeed Plus film. Results: Two film-SPP configurations showed significantly different gray levels at each step of the aluminum step wedge(p<0.05). The contrasts were comparable. Enhanced SP images were significantly superior to unenhaned images and film in all anatomical sturctures(p<0.01). The differences between unenhanced SP images and film were significant(p<0.05) except root canal and cortical bone on alveolar crest. For anatomical items. there were statistically significant difference among five observers(p<0.05). Conclusions: The image quality of enhanced SP images were superior to Ektaspeed Plus film. and Digora system is potentially applicable to clinical diagnosis.

  • PDF

소동물 X-선 진단에 있어서 광범위 관용도 필림의 이용에 관하여 (Application of Wide Latitude Film to Radiographic Diagnosis in Small Animal)

  • 최민철
    • 한국임상수의학회지
    • /
    • 제9권2호
    • /
    • pp.473-481
    • /
    • 1992
  • To elucidate the applicability of the wide latitude X-ray film for radiographic diagnosis and treatment of diseases in small animals, the quality of the wide latitude film was compared with that of the standard latitude film which is commonly used in veterinary clinic. The images of head, neck, thorax, abdomen, extremities and joints were radiographed with the wide latitude and standard latitude film in fourteen dogs. In soft tissues such as abdominal organs, lung, skin, mammary glands, the clearer and higher contrast of the image was observed on the wide latitude film. And these advantages were more apparent in pneumoeritoneography. Therefore. it can be suggested that the wide latitude film is practically useful for the evaluation of the images of soft tissues, and also can be used on hard tissue radiography with the same quality as the standard latitude film.

  • PDF

일반 측방 두부규격 방사선사진과 측방 추부규격 전산화 방사선사진에서의 계측점의 신뢰도에 대한 비교 연구 (A COMPARATIVE STUDY OF COMPUTED RADIOGRAPHIC CEPHALOMETRY AND CONVENTIONAL CEPHALOMETRY IN RELIABILITY OF HEAD FILM MEASUREMENTS (LANDMARKS IDENTIFICATION))

  • 김형돈;김기덕;박창성
    • 치과방사선
    • /
    • 제27권1호
    • /
    • pp.99-106
    • /
    • 1997
  • The purpose of this study was to compare & to find out the variability of head film measurements (and marks identification) between Fuji computed radiographic cephalometry and conventional cephalometry. 28 Korean adults were selected. Lateral cephalometric FCR film and conventional cephalometric film of each subject was taken. Four investigators identified 24 cephalometric landmarks on lateral cephalometric FCR film and conventional cephalometric film. The comparable measurements between lateral cephalometric FCR film and conventional cephalometric film were statistically analysed. The results were as follows : 1. In FCR film & conventional film, coefficient of variation (C.V.) of 24 landmarks was taken horizonta1ly & vertically. There is no significant difference of rank order of landmarks in C.V. between two films. 2. In comparison of significant differences of landmarks variability between FCR film & conventional film, horizontal value of coefficient of variation, showed significant differences in four landmarks among twenty-four landmarks, but vertical value of coefficient of variation showed significant differences in sixteen landmarks among twenty-four landmarks. FCR film showed significantly less variability than conventional film in 17 subjects among 20(4+16) subjects that showed significant difference.

  • PDF

직접 디지탈 방사선 촬영시스템과 Ektaspeed 및 Ektaspeed Plus 필름을 이용한 방사선 사진용 디지탈 영상시스템과의 비교 연구 (COMPARATIVE STUDY OF DIRECT DIGITAL RADIOGRAPHIC SYSTEM WITH FILM-BASED DIGITAL IMAGING SYSTEM USING EKTASPEED AND EKTASPEED PLUS FILM)

  • 도정주;김은경
    • 치과방사선
    • /
    • 제25권1호
    • /
    • pp.51-70
    • /
    • 1995
  • The purpose of this investigation was to compare the direct digital radiographic system with film-based digital imaging system using Ektaspeed and Ektaspeed Plus film with respect to image characteristics and detectability and evaluate the sensor noise with the use of subtraction method. Direct digital radiographic system which used was Sens-A-Ray system(Regam Medical Systems, Sundsvall, Sweden) and film-based digital imaging system was composed of Macintosh II ci computer, high resolution Sony XC-77 CCD camera and intraoral x-ray film(Kodak Ektaspeed film, Kodak Ektaspeed Plus film). Images were taken by using CCD sensor of Sens-A-Ray system, Ektaspeed film and Ektaspeed Plus film with variable exposure time(0.06s, 0.1s, 0.16s, 0.2s, 0.3s, 0.4s, 0.5s, 0.6s, O.8s, LOs), 5 times at each exposure time. And then ektaspeed films and ektaspeed plus films were digitized using CCD camera. Image groups were divided into 3 groups; Sens-A-Ray group(direct digital radiographic system), Ektaspeed group and Ektaspeed Plus group (film-based digital imaging system) They were assessed by the following three aspects; image density, image contrast and detectability and sensor noise of Sens-A-Ray system was also evaluated. The results were as follow : 1. S group showed higher density than E , EP group except at the low exposure time(p<0.01). 2. S group showed higher contrast than E,EP group except at the high exposure time(p<0.01). 3. All groups showed good detectability at the each proper exposure time. Lowest exposure time which shows maximum detectability in S,EP group(0.5s) was lower than that in E group(0.6s). 4. Sensor noise of Sens-A-Ray system generally increased according to exposure time. On the basis of the above results, it was considered that Sens-A-Ray system could show higher speed, higher contrast than Ektaspeed, Ektaspeed Plus film except at too high and low exposure time and the same detectability as the conventional intraoral film.

  • PDF

구내전악표준방사선사진 촬영시 촬영법과 필름유지법에 따른 촬영상의 실책 (TECHNICAL ERRORS IN COMPLETE MOUTH RADIOGRAPHIC SURVEYS ACCORDING TO RADIOGRAPHIC TECHNIQUES AND FILM HOLDING METHODS)

  • 최갑식;변종수;최순철
    • 치과방사선
    • /
    • 제16권1호
    • /
    • pp.103-112
    • /
    • 1986
  • 75명의 치과대학 4학년생들이 촬영한 300예의 구내전악표준방사선사진들을 촬영법과 필름의 유지법에 다라 필름을 피촬영자의 엄지나 검지로 유지하고 등각법으로 촬용한 경우 (Ⅰ군), 필름을 Rinn Sanp-A-Ray 기구로 유지하고 등각법으로 촬영한 경우 (Ⅱ군), 필름을 Rinn XCP기구로 유지하고 Short cone에서 평행법으로 촬영한 경우(Ⅲ군), 필름을 Rinn XCP기구로 유지하고 Long cone에서 평행법으로 촬영한 경우(Ⅳ군)으로 분류하여 75예의 구내전악표준방사선사진으로 구성된 각 군의 재촬영을 조사하여 각 군에서 가장 많이 나타난 실책의 종류와 부위, 그리고 구내전악표준방사선사진 1회당 평균재촬영매수에 대해 아래의 결과를 얻었다. Ⅰ군 : Incorrect film placement(47.8%)와 상악 견치부(26.9%)였으며 0.89매였다. Ⅱ군 : Incorrect film placement(44.0%)와 상악 대구치부(28.6%)였으며 1.12매였다. Ⅲ군 : Incorrect film placement(79.1%)와 상악 대구치부(32.0%)였으며 2.05매였다. Ⅳrns : Incorrect film placement(67.7%)와 상악 대구치부(30.7%)였으며 1.69매였다. 평균재촬영매수에서는 같은 촬영법인 Ⅰ군과 Ⅱ군간에서와, Ⅲ군과 Ⅳ군간에서는 유의한 차가 나타나지 않았으나 (P>0.05), 등각촬영법의 군 (Ⅰ+Ⅱ)보다 평행촬영법의 군(Ⅲ+Ⅳ)에서 0.86매 많았다 (P<0.01)

  • PDF

치아장경 측정을 위한 방사선학적 방법 (A RADIOGRAPHIC METHOD FOR DETERMINING THE ACTUAL TOOTH LENGTH)

  • 나경수;조봉혜
    • 치과방사선
    • /
    • 제25권2호
    • /
    • pp.281-286
    • /
    • 1995
  • Tooth length determination is a crucial step in endodontic treatment. Traditionally, radiographs are used to confirm working length of the root length. This study was performed to evaluate the radiographic distortion(magnification) and calculate correction coefficients for the object-film distance. Ninty-six radiographs were made of eight extracted teeth(two upper first premolars, two lower first premolars, two upper first molars, and two lower first molars) by using the 16 inch long cone paralelling techniques with 1mm interval from 5 to 16mm tooth-film distance. The results were as follows. 1. The least mean radiographic distortion from 5 to 16mm tooth-film distance was 2.42±0.68%(the length of mesiobuccal cusp-mesial root of lower first molars), the greatest distortion was 4.74±1.36%(the length of mesiobuccal cusp-mesiobuccal root of upper first molars). 2. The greatest correction coefficient was 0.986(the mesiobuccal cusp-mesial root of lower first molars, the lowest one was 0.937(the mesiobuccal cusp-mesiobuccal root of upper first molars).

  • PDF

용접부에 대한 디지털 방사선투과영상과 필름 방사선투과영상의 상질 비교에 관한 연구 (Study on the Image Quality Comparison between in Digital RT and Film RT)

  • 박상기;안연식;길두송
    • 비파괴검사학회지
    • /
    • 제31권4호
    • /
    • pp.391-397
    • /
    • 2011
  • 용접부에 대한 품질 확보를 위하여 방사선투과시험을 실시하고 있으나 기존의 방사선투과시험은 필름을 사용한 아날로그 방법을 적용하고 있는데 비용과 시간이 많이 소요되고 시험 공정이 복잡하여 개선이 요구되고 있다. 본 연구에서는 용접부에 대한 디지털 방사선투과영상과 아날로그 방사선투과영상의 상질을 비교한 결과, 디지털 방사선투과영상은 디지털 영상 개선 과정으로 인하여 필름 영상에 비해 보다 세밀한 관찰을 할 수 있었다. 따라서 디지털 방사선투과시험이 개선이 요구되고 있는 기존 필름에 의한 방사선투과시험을 대체할 수 있을 것으로 평가된다.