• 제목/요약/키워드: Radiographic Testing

Search Result 71, Processing Time 0.028 seconds

Dental imaging characterization of micropigs

  • Lee, Hyeyeon;Choi, Mihyun;Chang, Jinhwa;Jung, Joohyun;Kim, Mieun;Lee, Namsoon;Kim, Junyoung;Choi, Mincheol
    • Korean Journal of Veterinary Research
    • /
    • v.50 no.4
    • /
    • pp.311-317
    • /
    • 2010
  • Recently the micropig has been developed as human disease model. The dental and orofacial region of micropig is similar to that of humans, so it has been used for testing implant materials and techniques. The purpose of this study is on dental image at each age using radiography and computed tomography. Total twenty-two male micropigs, two or three animals of each 1, 3, 5, 7, 9, 12, 18 and 24 months old, were given radiographic examinations. After general anesthesia, extra- and intra-oral radiographic technique and computed tomographic scans were performed to assess the dental characterization of micropigs. The total deciduous dental formula comprised 28 teeth and was depicted as Di 3/3, Dc 1/1, Dp 3/3. The total permanent dental formula comprised 44 teeth and was depicted as I 3/3, C 1/1, P 4/4, M 3/3. Hypodontia of the first premolars was common in the micropig. The permanent teeth erupted from 3 to 24 month after birth. The sequence of eruption of the permanent teeth was M1, P1, I3, C, M2, I1 + P3 + P4, P2, I2, M3. Dental imaging enables visualization of the unerupted teeth and gives more information about the development of the teeth. The growth pattern of the teeth obtained through radiographic and computed tomographic examination provides basic data in the micropig as animal model for dental research.

Autosomal Recessive Malignant Infantile Osteopetrosis Associated with a TCIRG1 Mutation: A Case Report of a Neonate Presenting with Hypocalcemia in South Korea

  • Oh, Yun Kyo;Choi, Koung Eun;Shin, Youn-Jeong;Kim, Eun Ryoung;Kim, Ji Yeon;Kim, Min Sun;Cho, Sung Yoon;Jin, Dong Kyu
    • Neonatal Medicine
    • /
    • v.28 no.3
    • /
    • pp.133-138
    • /
    • 2021
  • Osteopetrosis refers to a group of genetic skeletal disorders characterized by osteosclerosis and fragile bones. Osteopetrosis can be classified into autosomal dominant, autosomal recessive, or X-linked forms, which might differ in clinical characteristics and disease severity. Autosomal recessive osteopetrosis, also known as malignant osteopetrosis, has an earlier onset, more serious clinical symptoms, and is usually fatal. We encountered a 1-day-old girl who was born full-term via vaginal delivery, which was complicated by meconium-stained amniotic fluid, cephalo-pelvic disproportion, and nuchal cord. Routine neonatal care was provided, in addition to blood tests and chest radiography to screen for sepsis, as well as skull radiography to rule out head injuries. Initial blood tests revealed hypocalcemia, which persisted on follow-up tests the next day. Radiographic examinations revealed diffusely increased bone density and a "space alien" appearance of the skull. Based on radiographic and laboratory findings, the infantile form of osteopetrosis was suspected and genetic testing for identification of the responsible gene. Eventually, a heterozygous mutation of the T cell immune regulator 1, ATPase H+ transporting V0 subunit a3 (TCIRG1) gene (c.292C>T) was identified, making this the first reported case of neonatal-onset malignant osteopetrosis with TCIRG1 mutation in South Korea. Early-onset hypocalcemia is common and usually results from prematurity, fetal growth restriction, maternal diabetes, perinatal asphyxia, and physiologic hypoparathyroidism. However, if hypocalcemia persists, we recommend considering 'infantile of osteopetrosis' as a rare cause of neonatal hypocalcemia and performing radiographic examinations to establish the diagnosis.

A Study on Quantitative Thickness Evaluation Using Film Density Variation in Film Radiography (Film Radiography에서 농도차를 이용한 정량적 두께 평가에 관한 연구)

  • Lee, Sung-Sik;Lee, Jeong-Ki;Kim, Young-H.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.19 no.5
    • /
    • pp.356-362
    • /
    • 1999
  • Based on the assumption that film density increases exponentially with exposure in the industrial radiographic film. an equation representing the characteristic curves of industrial radiographic films and a new density-thickness relation are suggested. The accuracy and reliability of the suggested relation has been tested using radiographs of a carbon steel step wedge with known thickness variation by polychromatic X-ray and ${\gamma}$-ray ($Ir^{192}$). The experimental results were well agreed to the proposed relation in the range of film densities from 1.0 to 3.5 and it was more accurate than the conventional relation. It is also found that ${\gamma}$-ray is more effective in this purpose than polychromatic X-ray, which results in variation of effective linear absorption coefficient due to beam hardening effect as thickness increases. Therefore using the equation and experimentally determined parameters the quantitative evaluation of thickness variation is possible and it can be used to evaluate the depth of local corrosion of pressure vessels in plants.

  • PDF

Implementation Status of Performance Demonstration Program for Steam Generator Tubing Analysts in Korea

  • Cho, Chan-Hee;Lee, Hee-Jong;Yoo, Hyun-Ju;Nam, Min-Woo;Hong, Sung-Yull
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.1
    • /
    • pp.63-68
    • /
    • 2013
  • Some essential components in nuclear power plants are periodically inspected using non-destructive examinations, for example ultrasonic, eddy current and radiographic examinations, in order to determine their integrity. These components include nuclear power plant items such as vessels, containments, piping systems, pumps, valves, tubes and core support structure. Steam generator tubes have an important safety role because they constitute one of the primary barriers between the radioactive and non-radioactive sides of the nuclear power plant. There is potential that if a tube bursts while a plant is operating, radioactivity from the primary coolant system could escape directly to the atmosphere. Therefore, in-service inspections are critical in maintaining steam generator tube integrity. In general, the eddy current testing is widely used for the inspection of steam generator tubes due to its high inspection speed and flaw detectability on non-magnetic tubes. However, it is not easy to analyze correctly eddy current signals because they are influenced by many factors. Therefore, the performance of eddy current data analysts for steam generator tubing should be demonstrated comprehensively. In Korea, the performance of steam generator tubing analysts has been demonstrated using the Qualified Data Analyst program. This paper describes the performance demonstration program for steam generator tubing analysts and its implementation results in Korea. The pass rate of domestic analysts for this program was 71.4%.

Metallurgical Characteristics and Manufacturing Techniques of Ring-Pommel Swords Excavated from Ancient Tombs in Hadae, Ulsan (울산 하대고분 출토 민고리자루칼의 재질 특성과 환두부 제작 방법)

  • Jo, Ha Nui;Kim, Han Seul;You, Ha Rim;Lee, Jae Sung
    • Journal of Conservation Science
    • /
    • v.36 no.3
    • /
    • pp.197-212
    • /
    • 2020
  • This study analyzed the microstructure of ring-pommel swords, excavated from Ancient Tombs, Hadae, Ulsan and examined their production technique, using non-destructive testing and a metallurgical method. The results confirmed that the five ring-pommel swords, unearthed in Ancient Tombs, Hadae, Ulsan, as identified by radiographic non-destructive testing, had been solely manufactured using iron, through forging based on the single-piece technique. Furthermore, these results were compared with previous studies, and the manufacturing techniques of single-piece ring-pommel swords were categorized into three types: pure iron - changing the shape, pure iron - changing the shape - carburization, and steel - changing the shape - quenching. The ring-pommels of four swords had around 0.7% of carbon content, which is as much as for eutectoid steel and higher than for other parts of these swords, such as the backs of their blades and handles. The weapon function of a small ring-pommel sword, under 60cm in length, was maximized by quenching focusing on its blade. Conversely, the martensite quenching structure was not observed in four ring-pommel swords shorter than 75cm. In other words, the same types of single-piece ring-pommel swords(late in 2C~early in 4C) were unearthed from Ancient Tombs, Hadae, and the group who has manufactured these swords is presumed to have limited their effectiveness, functionally depending on purposes, through an iron-making process and heat-treatment techniques.

Detection and Comparison of Surface Defects in Pipe Welds (배관 용접부 표면결함 검출 및 비교)

  • Jung, Yoon-Soo;Gao, Jia-Chen;Ahn, Tae-Hyoung;Kim, Jae-Yeol
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.1
    • /
    • pp.43-48
    • /
    • 2020
  • At present, 24 nuclear power plants are in operation nationwide as the main power source responsible for about 27% of Korea's electricity, and five nuclear power plants are currently under construction. Issues of nuclear safety and reliability have always existed, but after the Fukushima accident, ensuring reliability has become an even more important issue for safety. Compared to other kinds of accidents, the initial response after a nuclear accident is more important than any other accident. Prior to accidents, it is important to be able to predict and judge the accident in advance for the sake of prevention. In this research, non-destructive inspection methods for existing pipe welds include radiographic, ultrasonic, magnetic particle practice, and liquid penetration testing. For this experiment, carbon steel pipes like that of the material used in nuclear pipes were adopted, and specimen welded to the flange (Flange) were manufactured. After testing, the weld specimen were not damaged through the infrared thermography (IRT) experiment. This study attempted to improve the safety of carbon steel pipes through a comparative analysis of finite element analysis.

Development of Inspection System for Aluminum Castings with X-Ray TDI Camera (X-Ray TDI Camera를 이용한 알루미늄 주강품 검사장치 개발)

  • Nam, Mun-Ho;Park, Seong-Wook;Kim, Chang-Ho;Chung, Chan-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1734-1735
    • /
    • 2011
  • In case of inspection on aluminum castings, traditional RT (Radiographic Testing) method have been utilized for its advantages in interpretation, cost and perpetual storage. But it has disadvantages like time consumption in film processing, low efficiency in storage and environmental pollution. In this thesis, a DRS (Digital Radiography System) utilizing X-Ray TDI Camera (Time Delay and Integration Camera) is developed. Inspections on aluminum castings are performed using the developed Digital Radiography System, DRS and reviewed if newly developed system can substitute for the traditional method.

  • PDF

Method of Radiographic Testing and Industrial Application (방사선 투과검사의 방법과 산업적용)

  • Lee, Yong
    • Journal of Welding and Joining
    • /
    • v.12 no.4
    • /
    • pp.35-40
    • /
    • 1994
  • 비파괴검사(NDT)란 시험품에 손상을 주지 않고 내.외부에 존재하는 불연속부(결함)을 찾아내는 방법으로 다음과 같이 그 종류를 분류할 수 있다. (1) 표면결함 검출을 위한 비파괴검사 - 육안검사(VT) : 확대경 등에 의한 치수, 형상확인 - 자분탐상검사(MT) : 강자성체에 적용, 표면(하) 결함검출 - 침투탐상검사(PT) : 금속, 비철금속에 적용, 표면개구 결함검출 - 와류탐상검사(ET) : 도체 표층부(봉, 관 등) (2) 내부결함 검출을 위한 비파괴검사 - 방사선 투과검사(RT) : 결함의 종류, 형상의 판별 우수 - 초음파 탐상검사(UT) : 균열 등 면상 결함검출 등 우수 (3) 기타 비파괴검사 - Strain 측정 : 안전성 평가 - 음향방출시험(AET) - 누설시험(LT) - 중성자 방사선시험(NRT) 이상에서 보는 바와 같이 여러 종류의 비파괴검사가 있으나, 그 중에서 용접부에 적용되는 가장 일반적인 검사방법인 방사선 투과검사에 대해 기술하고자 한다.

  • PDF

The Evaluation of Joints Characteristics of Friction Stir Welded Al Alloys for Automobiles (마찰교반접합(FSW)에 의한 자동차용 Al합금의 접합부 특성 평가)

  • Kim, Heung-Ju;Jo, Hyeon-Jin;Jang, Ung-Seong;Bang, Han-Seo
    • Proceedings of the KWS Conference
    • /
    • 2005.06a
    • /
    • pp.171-173
    • /
    • 2005
  • To evaluate the applicability of dissimilar metal friction stir welding in automobile manufacturing process, friction stir welding trials were carried out for typical 5000 and 6000 series aluminum alloy sheets with 2mm thickness. The sound joints of A15052 and A16061-T6 alloys were successfully formed under a wide range of welding condition. Excellent weld ability has been obtained at a condition of rotating speed 2000rpm and travel speed 100mm/min, while a radiographic test also confirmed defect free joint for this condition. Through the Erichsen cup test, the plastic formability of the FSWelded joints was found to be about 83% of base metal.

  • PDF

Aural Abscess in a River Cooter (Pseudemys concinna)

  • Bae, Jieun;Go, Jae Cheon;Son, Jiwon;Han, Jae-Ik
    • Journal of Veterinary Clinics
    • /
    • v.37 no.1
    • /
    • pp.57-59
    • /
    • 2020
  • A 3-year-old, captive female river cooter was presented with a 4-day history of progressive unilateral swelling of the right side of the head, lethargy, and anorexia. History, physical examination, and radiographic examination revealed an aural abscess. After administration of antibiotics and supportive care, surgical intervention was performed. Swab samples were collected from the tympanic cavity during surgery for cytology and antimicrobial susceptibility testing. Molecular analyses of 16S ribosomal RNA gene sequences identified Citrobacter spp. and Morganella morganii. The patient was treated with ciprofloxacin and meloxicam and recovered after 2 months. This report describes the successful correction of a unilateral aural abscess that responded well to surgical intervention and a properly selected antibiotic.