• 제목/요약/키워드: Radiographic Testing

검색결과 71건 처리시간 0.028초

방사선투과시험(放射線透過試驗)에 있어서 KS와 ASME Code의 비교(比較)에 관(關)한 연구(硏究) (Study on Comparison of Korean Industrial Standard and ASME BPV Code for Radiographic Examination)

  • 김진구;박병철
    • 비파괴검사학회지
    • /
    • 제4권2호
    • /
    • pp.20-29
    • /
    • 1985
  • There are two basic concepts in industrial radiographic examination; one is a radio-graphic sensitivity, and the other is a acceptance criteria. The comparison of these main points are studied for KS Standard and ASME Boiler and Pressure Vessel Code. From the results of the experiment, higher radiographic sensitivity is required in KS Standard when the thickness of material to be examined is less than 20mm in single wall technique. The acceptance criteria for linear type indications are described on same concept in two standards, whereas the acceptance criteria for rounded indications of KS Standard which mainly depends upon the object thickness are more severe than those of ASME BPV Code.

  • PDF

방사선투과사진에 의한 결함깊이 및 높이의 평가 (Estimation of Flaw Depth and Height by Radiography)

  • 강계명;박은수;심언덕
    • 한국재료학회지
    • /
    • 제12권8호
    • /
    • pp.682-687
    • /
    • 2002
  • The three-dimensional estimation on the depth and height of flaw by using the difference of radiographic contrast density was studied. First, the specimens having artificial flaws of various depths and heights were prepared and the radiographic testing was performed. The radiographic depth of flaw was investigated and estimated on the effect of the scattered radiation with the change of distance between flaw and film. The height of flaw was estimated from the radiographic test with the reference specimen. The radiographic contrast with flaw depth decreased with increasing the flaw depth. The scattered radiation increased with increasing flaw depth and varied with the location between flaw and film. However, in the case of flaw height, the contrast density increased with increasing flaw height. It is thought due to the change in volume generating the scattered radiation which reaches a film.

용접부 비파괴 검사의 신뢰성 비교: 화력 발전소의 보일러 수냉벽 배관 사례연구 (Comparative Reliability of Nondestructive Testing for Weld: Water Wall Tube in Thermal Power Plant Boiler Case Study)

  • 최창덕;임익성
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제18권3호
    • /
    • pp.240-249
    • /
    • 2018
  • Purpose: The purpose of this research is to find which technique, between the PAUT (Phased array ultrasonic test) that has been used widely in practice and RT (Radiographic test) that was used widely in the past, has the higher reliability as a non-destructive testing of welding points in water wall tubes. Methods: To evaluated the reliability of non-destructive testing, eleven test pieces that were fabricated intentionally, which have the most frequently occurred defect types in water wall tubes and then both the PAUT and RT were performed on those eleven test pieces to compare their reliability. Results: The differences of type of defect, length are occurred due to the characteristics of nondestructive testing. The RT could not detect the lack of fusion defect type in specimen #4 and #8 while PAUT could not detect the lateral crack and 1 mm size small porosity in specimen #11. Conclusion: It is concluded that applying both the RT and PAUT result the best reliability rather than applying only one test method, if it is possible, in nondestructive testing of weld water wall tube in thermal power plant boiler case.

용접부에 대한 디지털 방사선투과영상과 필름 방사선투과영상의 상질 비교에 관한 연구 (Study on the Image Quality Comparison between in Digital RT and Film RT)

  • 박상기;안연식;길두송
    • 비파괴검사학회지
    • /
    • 제31권4호
    • /
    • pp.391-397
    • /
    • 2011
  • 용접부에 대한 품질 확보를 위하여 방사선투과시험을 실시하고 있으나 기존의 방사선투과시험은 필름을 사용한 아날로그 방법을 적용하고 있는데 비용과 시간이 많이 소요되고 시험 공정이 복잡하여 개선이 요구되고 있다. 본 연구에서는 용접부에 대한 디지털 방사선투과영상과 아날로그 방사선투과영상의 상질을 비교한 결과, 디지털 방사선투과영상은 디지털 영상 개선 과정으로 인하여 필름 영상에 비해 보다 세밀한 관찰을 할 수 있었다. 따라서 디지털 방사선투과시험이 개선이 요구되고 있는 기존 필름에 의한 방사선투과시험을 대체할 수 있을 것으로 평가된다.

Middle superior and anterior superior alveolar nerve injury following trauma to the maxillary sinus: a prospective clinico-radiographic evaluation

  • Sathish Radhakrishna;Eashwari Narayanan
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제49권5호
    • /
    • pp.262-269
    • /
    • 2023
  • Objectives: Anterior maxillary sinus wall fractures are common in all types of maxillofacial trauma. They can result in various complications, including injury to the surrounding nerves. Owing to its anatomy, trauma to the maxillary antrum can result in injury to the middle superior alveolar nerve (MSAN) and the anterior superior alveolar nerve (ASAN). The purpose of this study is to evaluate neurosensory deficits (NSD) present in maxillary gingiva, incisors, and premolars after injury to the anterior wall of the maxillary antrum. Materials and Methods: This prospective study was conducted among 39 patients sustaining unilateral fractures of the anterior maxillary sinus wall. Clinical neurosensory tests including two-point discrimination and fine touch discrimination were performed to classify the extent of nerve injuries as mild, moderate, severe, or anesthetic. Additional temperature discrimination and pulpal sensibility tests (electric pulp testing and cold testing) were carried out. A comparison of radiographic fracture patterns and severity of nerve injury was done. Testing was carried out immediately after trauma and at 2-month follow-up. Results: More than half of the patients assessed in the study group presented with NSD of the teeth and gingiva after trauma. The incidence of deficits varied with the type of test used to measure them. Most frequently, patients presented with both loss of two point as well as fine touch discrimination thresholds. Severe nerve injuries were associated with loss of temperature discrimination clinically and displaced fractures radiographically. There was no significant relationship between the recovery of pulpal and gingival sensation. The patterns of injury and recovery in ASAN and MSAN were similar. Conclusion: NSD after trauma to the maxillary antrum is relatively common. Clinical loss of temperature discrimination and radiographic signs of fracture lines passing through the canalis sinuosus are predictors of persistent and severe oral NSD.

노치가공법에 의한 기계적 피로결함 시험편 제조 (Fabrication of Mechanical Fatigue Flawed Specimen with Notch Processing)

  • 홍재근;박반욱
    • 연구논문집
    • /
    • 통권32호
    • /
    • pp.55-64
    • /
    • 2002
  • Performance demonstration with real flawed specimens has been strongly required for nondestructive evaluation of safety class components in nuclear power plant. Specimen has been designed to produce mechanical fatigue flaw with tension stress and fatigue flaw has been produced to control stress and cycle, for suitable roughness. Notch condition is considered for control of fracture mode. After seal welding for fracture surface, final welding was performed to complete flaw specimen with GTAW(Gas Tungsten Arc welding) and FCAW(Flux Cored Arc Welding). It was demonstrated flaw size of flawed specimen by radiographic. testing and ultrasonic testing.

  • PDF

액화천연가스 저장탱크 9% 니켈강 용접부의 방사선투과시험 필름에 나타나는 밴드형상의 지시 해석 (Interpretation for Band-Type Indication on Radiography of 9% Ni Steel Welds for LNG Storage Tanks)

  • 이승현;이승림;이영순
    • 비파괴검사학회지
    • /
    • 제30권5호
    • /
    • pp.479-483
    • /
    • 2010
  • 초저온 액화가스인 LNG의 저장탱크에 사용되는 9% 니켈강은 Inconel 혹은 Hastelloy 계열 용접봉을 사용하여 용접되며, 용접부는 저합금강과 오스테나이트 스테인리스강의 이종금속 용접부와 유사한 특성을 가지고 있다. 용접부에 대한 방사선투과시험 시 용접조건에 따라 밴드형태의 지시가 방사선투과 필름 상에 나타나곤 한다. 따라서 본 연구에서는 이에 대한 해석을 위하여 재료, 방사선투과시험, 초음파탐상시험, 액체침투탐상시험 및 조직시험을 통하여 의사지시 여부를 확인하였으며, 방사선투과시험 해석 및 밴드형태 지시의 발생 원인을 제시하였다.

방사형 척도분석 모델을 활용한 방사선투과검사 업체의 위험성 분석 (Risk Analysis of Radiographic Testing Companies using Radial Scale Analysis Model)

  • 한지영;권다영;김병수;김용민
    • 한국방사선학회논문지
    • /
    • 제12권6호
    • /
    • pp.745-753
    • /
    • 2018
  • 방사선이 다양한 분야에 사용됨에 따라 방사선작업종사자의 수가 증가하고 있으며, 이에 따라 종사자의 안전에 대한 우려도 높아지고 있다. 국내에서는 KISOE 시스템, 발주자보고 등을 통해 종사자의 안전 확보에 주력하고 있다. 선행연구에서는 종사자 및 업체의 안전 확보를 위한 위험성 평가에 피폭선량과 더불어 이외의 항목에 대한 추가적 평가가 효과적일 것이라고 판단하여 평가를 위한 항목들 및 방사형 척도분석 모델을 개발하였다. 이에 본 연구에서는 2016년 방사선투과검사업체의 자료를 방사형척도분석 모델에 적용하여 실제 업체의 위험성 평가를 수행하였다. 또한 위험성이 낮을 것으로 예상되는 업체 2곳과 위험성이 높을 것으로 예상되는 업체 2곳을 선정하여 위험성 분석을 수행하였다. 분석 결과에서 예상과 동일한 결과를 얻어 모델의 타당성을 확인할 수 있었다. 전체 56개 업체의 위험성 평가가 수행되었고 업체별 문제점에 따른 개선 및 점검사항을 예측하였다. 본 연구 결과를 방사선투과검사업체 및 규제기관에서 자체 평가 및 규제 기준 등으로 활용할 수 있을 것으로 예상된다.

감마선투과검사 장치의 자동 원격조작기 개발 (Development of Automatic Remote Exposure Controller for Gamma Radiography)

  • 주광태;신진성;김동언;송정호;주승환;장홍근
    • 비파괴검사학회지
    • /
    • 제22권5호
    • /
    • pp.490-499
    • /
    • 2002
  • 국내 감마선투과검사용 조사장치는 1,000여대로 2,500여명의 종사자가 대부분 수동으로 원격 조작하는 실정으로 작업의 효율화와 방사선피폭 저감화를 위하여 자동 원격조작기의 사용이 요구된다. 이에 연구팀은 실무에 적합한 토크와 안전계수로부터 $54kgf{\cdot}cm$의 출력을 지닌 24V, 200W의 BLDC모터를 이용하여 $0.4{\sim}1.2m/s$ 범위의 선원 이동 속도를 조절할 수 있는 구동장치와 RF 센서로 구동 속도 조절, 광전센서에 의한 선원 위치 및 timer로 노출시간을 제어할 수 있는 무선 원격조작기를 개발하였다. 이와 같이 개발한 자동원격조작기는 AC 와 DC 겸용, 그리고 기존의 수통 원격조작기에 탈착이 가능하여 자동과 수동을 겸용할 수 있는 경제적 이점 등으로 활용도가 클 것으로 기대된다.

ATOS 80 고장력강의 보호가스량에 따른 용접부 방사선검사에 관한 연구 (A Study on Indications in Radiographic Tests in Welding Specimens According to Shielded Amounts of ATOS 80 High-strength Steel)

  • 백정환;최병기
    • 한국생산제조학회지
    • /
    • 제21권6호
    • /
    • pp.910-914
    • /
    • 2012
  • In constructing all kinds of equipment and steel structures, discontinuous areas such as weld defects formed in a welded structure tend to generate cracks that will result in damage. In this study, ATOS high-strength steel welding becomes important in butt welding where the tensile strength of the steel is over 80kg/$mm^2$. Structural discontinuities such as joints are more susceptible cracks in part due to their repeated loading and fatigue crack growth. The quality of parts produced depend or the shielded amounts of steel and on the skill of the welders in making strong welds. It is true that there are many factors that can be used to generate a lot of research in this area. However geometry and load conditions due to the combined effects with many issues could be solved through this study. Butt welding material at a plate thickness of 12t in ATOS 80 high-strength steel with a 4 pass, 20l/min, 24V/200A welder is good at making specimens with the quality shown in radiographic testing.