• Title/Summary/Keyword: Radiographic Evaluation

Search Result 454, Processing Time 0.029 seconds

Radiographic Evaluation of Adenoidal Size and Assessment of Impedance Audiometry in Children (소아 인두편도의 방사선적 고찰 및 Impedance 청력검사 소견)

  • 김주일;김철우;이병희;천경두
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1981.05a
    • /
    • pp.41.2-41
    • /
    • 1981
  • Tonsillectomy and adenoidectomy are the most common operations in the ENT field. Recent emphasis on careful selection of patients for these procedures derives from concern for complications of surgery, as well as the immunologic and anatomic functions of tonsils and adenoids. Adenoidectomy can relieve nasopharyngeal airway obstruction caused by enlarge adenoids, and can prevent complications such as heart failure and recurrent or chronic otitis media. We researched 117 cases of tonsilloadenoidectomy patients and 266 patients having routine examination from March, 1979 to February, 1981, and described the A/N ratio derived from linear measurements of lateral radiographs of the nasopharynx. The results of Impedance Audiometry and X-ray films from 117 cases of T&A patients were compared: 1) The average A/N ratio by age groups for 266 cases of normal children showed: 0.508 for age group, 0 to 3 years old, 0.533 for age group, 4 to 6 years old, 0.524 for age group, 7 to 9 years old, 0.519 for age group, 10 to 12 years old, 0.507 for age group, 13 to 15 years old, 0.481 for age group over 15 years old. The peak value lies in the age group of 4 to 6 years old. The sex difference of A/N ratio was not significant. 2) The average A/N ratio by age groups from 117 cases of T&A patients showed: 0.709 for age group, 0 to 3 years old, 0.733 for age group, 4 to 6 years old, 0.693 for age group, 7 to 9 years old, 0.707 for age group, 10 to 12 years old, 0.620 for age group, 13 to 15 years old, 0.756 for age group over 15 years old. 3) Among the 117 cases of T&A patients, the average A/N ratio for 57 cases in normal tympanogram was 0.688 and the average A/N ratio for 60 cases in abnormal tympanogram was 0.705. 4) Among 57 cases in abnormal tympanogram: 6 cases (10.5%) showed 0.40-0.59 of A/N ratio, 44 cases (77.2%) showed 0.60-0.79 of A/N ratio, and 7 cases (12.3%) showed 0.80-0.99 of A/N ratio. 5) Among 117 cases of T&A patients, 3 of 15 cases showing A/N ratio under 0.6, and 67 of 102 cases showing A/N ratio over 0.6, had paranasal sinusitis.

  • PDF

Clinical Result of Arthroscopic Partial Repairs in Massive Rotator Cuff Tears (광범위 회전근 개 파열의 관절경하 부분 봉합술의 임상적 결과)

  • Yoo, Jae-Chul;Ko, Kyung-Hwan;Woo, Kyung-Jea
    • Clinics in Shoulder and Elbow
    • /
    • v.12 no.2
    • /
    • pp.150-158
    • /
    • 2009
  • Purpose: With the better understanding of cuff function, partial repair or "force couple repair" for treating massive irreparable rotator cuff tear has gained some popularity. However, there were few reports on the results of partial repair. The purpose of this study was to report the clinical outcome of massive irreparable rotator cuff tears who received arthroscopic force-couple repair or partial repair. Materials and Methods: From June 2005 to Feb 2008, arthroscopic partial repairs were performed for 16 irreparable rotator cuff tears among the 101 large to massive rotator cuff tears that were operated on. Clinical and radiographic evaluation were done at the final follow-up. Results: There were 7 men and 9 women with a mean age of 66.6 years. The mean follow-up period was 27.3 month (range: 15-46). The pain VAS improved from 4.4 ($\pm2.50$) to 2.1 ($\pm2.26$) and the functional VAS improved from 46.9 ($\pm16.64$) to 70.0 ($\pm22.80$). The ASES score improved from 39.0 ($\pm10.80$) to 80.3 ($\pm16.78$) and the KSS score was 81.9 ($\pm16.74$) at the final follow-up. The acromio-humeral distance was 6.6 cm ($\pm1.74$) preoperatively and 6.2 cm ($\pm1.69$) postoperatively without significant change (p=0.3874). The degenerative changes had no statistically progressed (p=0.2663). Conclusion: Partial repair for massive rotator cuff injury patients showed improvement in the clinical score without progression of arthritic change at a mean of 2.3 years follow-up.

Development of $14"{\times}8.5"$ active matrix flat-panel digital x-ray detector system and Imaging performance (평판 디지털 X-ray 검출기의 개발과 성능 평가에 관한 연구)

  • Park, Ji-Koon;Choi, Jang-Yong;Kang, Sang-Sik;Lee, Dong-Gil;Seok, Dae-Woo;Nam, Sang Hee
    • Journal of radiological science and technology
    • /
    • v.26 no.4
    • /
    • pp.39-46
    • /
    • 2003
  • Digital radiographic systems based on solid-state detectors, commonly referred to as flat-panel detectors, are gaining popularity in clinical practice. Large area, flat panel solid state detectors are being investigated for digital radiography. The purpose of this work was to evaluate the active matrix flat panel digital x-ray detectors in terms of their modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE). In this paper, development and evaluation of a selenium-based flat-panel digital x-ray detector are described. The prototype detector has a pixel pitch of $139\;{\mu}m$ and a total active imaging area of $14{\times}8.5\;inch^2$, giving a total 3.9 million pixels. This detector include a x-ray imaging layer of amorphous selenium as a photoconductor which is evaporated in vacuum state on a TFT flat panel, to make signals in proportion to incident x-ray. The film thickness was about $500\;{\mu}m$. To evaluate the imaging performance of the digital radiography(DR) system developed in our group, sensitivity, linearity, the modulation transfer function(MTF), noise power spectrum (NPS) and detective quantum efficiency(DQE) of detector was measured. The measured sensitivity was $4.16{\times}10^6\;ehp/pixel{\cdot}mR$ at the bias field of $10\;V/{\mu}m$ : The beam condition was 41.9\;KeV. Measured MTF at 2.5\;lp/mm was 52%, and the DQE at 1.5\;lp/mm was 75%. And the excellent linearity was showed where the coefficient of determination ($r^2$) is 0.9693.

  • PDF

Surgical Management of Comminuted Midshaft Clavicle Fractures Using Reconstruction Plate and Circumferential Wiring: Does the Circumferential Wiring Interfere with the Bone Union? (쇄골 간부 복합 골절에서 재건 금속판 및 환 강선을 이용한 수술적 치료: 환 강선이 골 유합을 방해하는가?)

  • Kim, Kyung-Tae;Shin, Chung-Shik;Park, Young-Chul;Kim, Dong-hyun;Kim, Min-Woo
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.3
    • /
    • pp.245-252
    • /
    • 2021
  • Purpose: This study examined the radiological and clinical outcomes of internal fixation using a reconstruction plate and 21G circumferential wire in comminuted midshaft clavicular fractures. Materials and Methods: A retrospective cohort study was performed on 51 patients between 2005 and 2019. Thirty-two patients underwent internal fixation with a reconstruction plate and a 21G circumferential wire with minimal soft tissue detachment, and 19 patients underwent surgery without a wire. The patients were assessed with the radiographic parameters, the University of California at Los Angeles (UCLA) score, and the visual analogue scale (VAS) pain score. Based on this, patients who operated without a circumferential wire were set as the control group, and the differences in bone union between the two groups were compared. Results: Thirty-two patients were followed-up for an average of 65 weeks, and 19 patients in the control group were followed-up for an average of 56 weeks. The radiological evaluation confirmed the anatomical reduction and bone union in all 32 patients. No case of nonunion was present. The UCLA score was 32.38 on average and 33.11 in the control group (p=0.395). The VAS score was 1.00 on average and 0.84 in the control group (p=0.668). A significant difference in the bony union time was observed between the group who underwent internal fixation with a reconstruction plate and a 21G circumferential wire with minimal soft tissue detachment, and the control group (p=0.015). On the other hand, there was no statistical significance when other variables were controlled (p=0.107). Conclusion: For displaced midshaft clavicular fractures, internal fixation using a reconstruction plate and 21G circumferential wire maintained accurate anatomical reduction. The satisfactory clinical and radiological results mean that internal fixation using a reconstruction plate and 21G circumferential wire may be a good option for surgical treatment.