• Title/Summary/Keyword: Radioactive Iodine ($^{131}I$)

Search Result 70, Processing Time 0.026 seconds

Comparison of Thallium-201, Tc-99m MIBI and I-131 Scan in the Follow-up Assessment after I-131 Ablative Therapy in Differentiated Thyroid Cancer (방사성 옥소 치료 후 분화된 갑상선암 추적관찰에서 Thallium-201 스캔, Tc-99m MIBI 스캔과 I-131 스캔 검사 결과의 비교)

  • Kwon, Jae-Sung;Lee, Sung-Keun;Kim, Doe-Min;Park, Sae-Jong;Jang, Kyong-Sun;Kim, Eun-Sil;Kim, Chong-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.6
    • /
    • pp.493-501
    • /
    • 1999
  • Purpose: We conducted a comparative study to evaluate the diagnostic values of T1-201, Tc-99m MIBI and I-131 scans in the follow-up assessment after ablative I-131 therapy in differentiated thyroid cancer. Materials and Methods: The study population consisted of 20 patients who underwent surgical removal of thyroid cancer and ablative radioactive iodine therapy, and followed by one or mote times of I-131 retreatments (33 cases). In all patients, T1-201, Tc-99m MIBI, diagnostic and therapeutic I-131 scans were performed and the results were analyzed retrospectively. Also serum thyroglobulin levels were measured in all patients. The final diagnosis of recurrent or metastatic thyroid cancer was determined by clinical, biochemical, radiologic and/or biopsy findings. Results: Positive rates (PR) of Tc-99m MIBI, T1-201, diagnostic and therapeutic I-131 scans in detecting malignant thyroid tissue lesions were 70% (19/27), 54% (15/28), 35% (17/48) and 63% (30/48), respectively. The PR in the group of 20 cases (28 lesions) who underwent concomitant T1-201 and I-131 scans were in the order of therapeutic 131 scan 71%, T1-201 scan 54% and diagnostic I-131 scan 36%. There was no statistically significant difference between T1-201 and diagnostic I-131 scans (p>0.05). In the group of 20 cases (27 lesions) who underwent concomitant Tc-99m MIBI and I-131 scans, the PR were in the order of Tc-99m MIBI scan 70%, I-131 therapeutic scan 52% and I-131 diagnostic scan 33%. The PR of Tc-99m MIBI was significantly higher than that of diagnostic I-131 scan (p<0.05). Conclusion: Tc-99m MIBI scan is superior to diagnostic I-131 scan in detecting recurrent or metastatic thyroid cancer following ablation therapy in patients with differentiated thyroid cancer. T1-201 scan did not showed significantly higher positive rate than diagnostic I-131 scan. Instead of diagnostic I-131 scan before the I-131 retreatment, Tc-99m MIBI scan without discontinuing thyroid hormone replacement would be a prudent and effective approach in the management of these patients.

  • PDF

An Experimental Study on Airborne Contamination and Decontamination for $Na^{131}I$ Solution ($Na^{131}I$에 의(依)한 오염도(汚染度) 및 오염제거(汚染除去)의 실험적(實驗的) 연구(硏究))

  • Chu, Sung-Sil;Park, Chang-Yun
    • Journal of Radiation Protection and Research
    • /
    • v.9 no.2
    • /
    • pp.112-117
    • /
    • 1984
  • A lot of radioisotopes are applied to medical fields. It's very important to measure the activities on airborne radioiodine discharged in air from $Na^{131}I$ solutions and from patients treated with radioiodine. Also surface decontamination is another one important problem to be completly solved in the isotope laboratory where there is always the possibility of radiation contamination. The Authors measured the activities on airborne radioiodine with RI collector and scintillation counter. 1. The mean accumulative activity of airborne radioiodine discharged into air from $Na^{131}I$ solution was measured as $1.3{\times}10^{-3}/hr$ rate, and the maximum value was $1.8{\times}10^{-3}/hr$. 2. Radioactivity rate per hour of airborne iodine discharged into air from patients treated with $Na^{131}I$ was measured as $6.2{\times}10^{-5}/hr$ at 8 hour after administration of radioiodine and decreased into $2{\times}10^{-6}/hr$ after 24 hour. 3. Metalic surfaces such as stainless steel or aluminum are decontaminated 5 to 6 times more rapidly than wood and concrete surfaces. 4. Decontamination with wet wiping with detergent was 9 to 10 times more rapidly than dry wiping method, but dry wiping was useful for the first step to prevent spreading and flowing from liquid radioactive materials.

  • PDF

Dietary evaluation of a low-iodine diet in Korean thyroid cancer patients preparing for radioactive iodine therapy in an iodine-rich region

  • Ju, Dal Lae;Park, Young Joo;Paik, Hee-Young;Kim, Min-Ji;Park, Seonyeong;Jung, Kyong Yeun;Kim, Tae Hyuk;Choi, Hun Sung;Song, Yoon Ju
    • Nutrition Research and Practice
    • /
    • v.10 no.2
    • /
    • pp.167-174
    • /
    • 2016
  • BACKGROUND/OBJECTIVES: Despite the importance of a low-iodine diet (LID) for thyroid cancer patients preparing for radioactive iodine (RAI) therapy, few studies have evaluated dietary intake during LID. This study evaluated the amount of dietary iodine intake and its major food sources during a typical diet and during LID periods for thyroid cancer patients preparing for RAI therapy, and examined how the type of nutrition education of LID affects iodine intake. SUBJECTS/METHODS: A total of 92 differentiated thyroid cancer patients with total thyroidectomy were enrolled from Seoul National University Hospital. All subjects completed three days of dietary records during usual and low-iodine diets before $^{131}I$ administration. RESULTS: The median iodine intake was $290{\mu}g/day$ on the usual diet and $63.2{\mu}g/day$ on the LID. The major food groups during the usual diet were seaweed, salted vegetables, fish, milk, and dairy products and the consumption of these foods decreased significantly during LID. The mean energy intake on the LID was 1,325 kcal, which was 446 kcal lower than on the usual diet (1,771 kcal). By avoiding iodine, the intake of most other nutrients, including sodium, was significantly reduced during LID (P < 0.005). Regarding nutritional education, intensive education was more effective than a simple education at reducing iodine intake. CONCLUSION: Iodine intake for thyroid cancer patients was significantly reduced during LID and was within the recommended amount. However, the intake of most other nutrients and calories was also reduced. Future studies are needed to develop a practical dietary protocol for a LID in Korean patients.

Studies on the Effects of Injected Amount of I131 in Uptake and Release Rate by Thyroid in Guinea Pigs 1. On the Influence of Injected Amount of Redioiodine-131 in Uptake and Release Rate by Thyroid in Male Guinea Pigs (방사성옥도(放射性沃度)(I131)의 주입량(注入量)이 기니픽 갑상선(甲狀腺)에의 섭취(攝取) 및 방출률(放出率)에 미치는 영향(影響)에 관(關)한 연구(硏究) 제(第)1보(報) 방사성옥도(放射性沃度)(I131)의 주입량(注入量)이 웅(雄)기니픽 갑상선(甲狀腺)에서의 섭취(攝取) 및 방출률(放出率)에 미치는 영향(影響))

  • Chung, Yung Chai;Shim, Sang Chil;Lee, Heung Shik
    • Korean Journal of Veterinary Research
    • /
    • v.6 no.1
    • /
    • pp.24-30
    • /
    • 1966
  • In order to observe the effect of the injected radioactive iodine-$I^{131}$ on the uptake in thyroid of normal male guinea pigs and P.B.$I^{131}$ conversion ratio of $I^{131}$ in serum, 24 matured male guinea pigs were divided in 4 groups and $35{\mu}c$, $70{\mu}c$, $140{\mu}c$ and $280{\mu}c$ per kg of body weight respectively were injected subcutaneously. 1. The uptake rates of radioactveiodine-$I^{131}$ by external counts of thyroidal uptake reached the maximum level of uptake in 24 hours after injection. 2. As the injected amount increases, the uptake rates of maximum levels and release rate were increased. 3. Uptake rate in the removed thyroid have shown no statistical in the $35{\mu}c$ and $70{\mu}c$ groups of injected guinea pigs. 4. There was no statistical significance in $140{\mu}c$ and $280{\mu}c$ groups of injected guinea pigs. 5. P.B.$I^{131}$ conversion ratio of $I^{131}$ in serum was not in proportion to injected amounts: 61.0%(35), 70.2%(70), 75.3%(140) and 64.8%(280).

  • PDF

False-positive I-131 Uptake in Meningioma (갑상선암 환자에서 관찰된 뇌수막종의 위양성 옥소 섭취)

  • Jeong, Shin-Young;Seo, Ji-Hyoung;Bae, Jin-Ho;Hwang, Jeong-Hyun;Ahn, Byeong-Cheol;Lee, Jae-Tae;Lee, Kyu-Bo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.3
    • /
    • pp.272-273
    • /
    • 2004
  • We experienced a case with meningioma showing false positive I-131 uptake. A 55-years old female patient underwent high dose (150 mCi) radioactive iodine therapy to ablate remnant tissue after total thyroidectomy for papillary thyroid cancer. in addition to intense tracer uptake in thyroid bed, there was mild but focal abnormal uptake in left frontal lobe of the brain on post-therapy I-131 whole body scan. Subsequent brain MR imaging showed single mass lesion in left frontal lobe and the mass was resected under the impression of brain metastasis of thyroid carcinoma. Pathologic report confirmed meningioma from the surgical specimen.

Effect of therapeutic radioiodine activity on ablation response in differentiated thyroid cancer patients with cut-off serum thyroglobulin levels after 2 weeks of thyroid hormone withdrawal: a retrospective study

  • Ji Young Lee;Hee-Sung Song;Young Hwan Kim
    • Journal of Medicine and Life Science
    • /
    • v.19 no.3
    • /
    • pp.95-102
    • /
    • 2022
  • This retrospective study aimed to investigate whether there was a difference in the success rate of removal of residual thyroid tissue in patients with the same cutoff serum thyroglobulin (Tg) value-measured 2 weeks after thyroid hormone withdrawal (THW)-for different radioactive iodine (RAI) activities. We identified 132 patients with papillary thyroid cancer who were treated with total thyroidectomy and RAI therapy to evaluate the efficacy of three radioactivities of I-131: 1,110, 3,700, and 5,550 MBq. Serum Tg testing was performed 1 week before RAI treatment and 2 weeks after THW (pre-Tg); the cutoff pre-Tg level was below 10 ng/mL. Stimulated Tg levels were measured on the day of I-131 administration (off-Tg). After 6 months of treatment, we compared the groups for complete ablation, defined as no uptake on a diagnostic I-131 scan, stimulated Tg level of <1.0 ng/mL, and Tg antibody level of <100 ng/mL. Ninety-five patients (72.0%) achieved complete ablation, with 57.1% (8/14), 78.2% (68/87), and 61.3% (19/31) in the 1,110 MBq, 3,700 MBq, and 5,550 MBq groups, respectively. There was no significant difference in the complete ablation rates between the three groups. In the multivariate analysis, the off-Tg level was a significant predictor of complete ablation. RAI therapy with low radioactivity (1,110 MBq) seemed sufficient for ablation in patients with papillary thyroid cancer with a pre-Tg level below 10 ng/mL. The off-Tg level is a promising and useful predictor of complete ablation after initial RAI therapy.

Current Opinions on the Radioiodine Treatment of Graves' Hyperthyroidism (Graves병 갑상선 기능항진증에서 방사성 옥소 치료의 지견)

  • Lee, Sang-Woo;Lee, Jae-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.6
    • /
    • pp.341-354
    • /
    • 2003
  • Radioactive iodine therapy using I-131 for hyperthyroidism has been used for more than 50 years, and generally considered safe and devoid of major side effects. Appropriate patient selection criteria and clinical judgement concerning patient preparation should be employed for its optimal use. It has not been possible to resolve the trade-off between efficient definite cure of hyperthyroidism and the high incidence of post-therapy hypothyroidism. The dose of the I-131 needed to maintain euthyroid state remains an area of uncertainity and debate. Early side effects are uncommon and readily managable. Other than the need for long-term monitoring and, in most cases, lifelong thyroid hormone treatment for late adverse consequences of this treatment remains only conjectural. We have reviewed general principles and recent advances in radioiodine treatment for Graves' hyperthyroidism, specially regarding to several controversies.

The Fabricating and Utilizing of the Transmission Scan Tool for I-131 Whole Body Scan (I-131 전신 스캔을 위한 Transmission Scan Tool 제작과 활용)

  • Shin, Chae-Ho;Pyo, Sung-Jai;Kim, Bong-Su;Cho, Yong-Gyi;Jo, Jin-Woo;Kim, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.40-46
    • /
    • 2009
  • Purpose: A whole body scan using a radioactive iodine (I-131) for the patients with differentiated thyroid cancer is generally an useful method to detect the remnant thyroid tissue, recurred lesion or metastasis lesion after a surgery. The high dose treatment using the radioactive iodine recently tends to increase, and a hospitalization wait for the treatment has been delayed for several months. In this hospital, the treatable patients per week were increased in number through expanding a water-purifier tank and the examination time also increased as the I-131 whole body scan patients increased. Improvement for this problem, this research reduce the existing examination time and classifying the lesion's exact position intended to by fabricating and utilizing the transmission scan tool and an excellent resolution for whole body imaging. Materials and Methods: After conducting the whole body scan for patients who visited the department from February to July 2008 and received the I-131 whole body scan using the ORBITER Gamma Camera. A rail was installed in the examination table for the transmission scan for show a contour of surface area and then the transmission image was obtained and fused to the whole body scan through fabricating the tool to put a flood phantom of diluted 2 mCi $^{99m}Tc$-pertechnetate. Results: Fused image of I-131 whole body scan and the transmission scan had the excellent resolution to discriminate an oral cavity or salivary gland region, neck region's lesion, and metastasis region's position through a simple marking, and could reduce the examination time of 8~28 minutes because without the additional local image. Conclusions: In I-131 whole body scan, the transmission scan can accurately show a contour of surface area through the attenuation of radioactivity, and is useful to indicate the remnant thyroid tissue or metastasis lesion's position by improving the resolution through the fusion image with alreadyexecuted I-131 whole body scan. Also, because the additional local image is not necessary, it can reduce the time required for the examination. It will extensively apply to other clinical examinations to be helpful for identifying an anatomical position because it shows the contour of surface area.

  • PDF

The Effect on The Result, in Case of the In-vitro Test Performance after an Imaging Test (핵의학 영상검사 후 시행된 핵의학 검체검사에서의 영향)

  • Moon, Ki Choon;Kwon, Won Hyun;Kim, Jung In;Lee, In Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.149-152
    • /
    • 2014
  • Purpose: At our hospital blood is collected from a patient before an imaging test, with the concern of any effect possible when a nuclear medicine imaging test and an in-vitro test are carried out at the same time. However, occasionally, the blood collection is performed after an imaging test, with the reasons that the patient is not properly guided or the patient doesn't follow the guide correctly. In that case, we prefer to gather blood again after a few days. The purpose of this study is not only to see whether there is any effect of an imaging test on the result of the in-vitro test performed with the blood collected after the imaging test, but also to study how many days waiting after each test is appropriate to take a blood sample, if the effect exists. Materials and Methods: From September to October 2013, blood were collected from 13 patients in our hospital regardless of age and sex each time before and after the injection of the radioactive isotope from the tests : PET-CT, Gated Myocardial SPECT, and DTPA GFR Scan. Considering a half-life, AFP, CA19-9, CEA, TSH, and T3 were carried out right after the blood collection. In case of an iodine therapy, blood were taken each time before and after taking radioactive iodine, and, after AFP, CA19-9, and CEA, the difference between them in consistency and in cpm were compared. Results: With 10 patients after the imaging tests and 3 patients after the iodine therapy, their serum cpm was over 10,000. Over time, the cpm decreased in accordance with the half-life ($^{18}F$ 110minutes, $^{99}mTc$ 6hours, $^{201}Tl$ 72hours, $^{131}I$ 7days). Between the two cases, one before and the other after the injection of the radioactive isotope, the cpm and the results of AFP, CA19-9, CEA, TSH, and T3 from three patients each test, PET-CT, Gated Myocardial SPECT, and DTPA GFR Scan, were very similar. In addition, in case of an iodine therapy, there was also not a meaningful difference in the cpm and the results of AFP, CA19-9, and CEA, from three patients in an iodine therapy, between the two cases, one before and the other after taking the radioactive iodine. Conclusion: In case a blood collection was performed after the imaging test which required a radioactive isotope injection, the cpm increased, differently according to the kind of the radioactive isotope. However, the results of the in-vitro tests like AFP, CA19-9, CEA, TSH, T3, etc were nearly not affected. As the result, it's considered that there will not be any significant effect also from other tests, as the result from the performed seven tests.

  • PDF