• 제목/요약/키워드: Radio frequency Communication method

검색결과 286건 처리시간 0.025초

Design of Single Balanced Diode Mixer with Filter for Improving Band Flatness in Microwave Frequency Down Converter (마이크로파 주파수 하향 변환기에서의 대역 평탄도 개선을 위한 여파기 집적형 단일 평형 다이오드 혼합기 설계)

  • Ryu, Seung-Kab;Hwang, In-Ho;Han, Seok-Kyun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • 제18권1호
    • /
    • pp.37-43
    • /
    • 2007
  • In this.paper, we introduce design and implementation results of the single balanced diode mixer for European point-to-point microwave radio in order to improve flatness performance. When a resonator such as RF filter is integrated with a mixer, impedance characteristic of 50 ohm is maintained only in RF band, not in LO band resulting deterioration of flatness performance because of LO power variation on the diode. In the paper, we suggest a design method of mixer integrated with image rejection filter and LO harmonic filter to have a better performance of flatness using embedding electrical length between filter and mixer's port. Frequency specification of fabricated mixer is $21.2{\sim}22.6\;GHz$ for RF, $19.32{\sim}20.72\;GHz$ for LO and 1.88 GHz+/-50 MHz for IF, respectively. Measured results show conversion loss of 8.5 dB, flatness of 2 dB, input PldB of 8 dBm, IIP3 of 15 dBm under LO power level of 10 dBm. Return losses of RF, LO and IF port are under -12 dB, -10 dB and -5 dB, respectively. Isolations of LO/RF and LO/IF are 20 dB and 50 dB, respectively.

Energy-Efficient Routing Protocol based on Interference Awareness for Transmission of Delay-Sensitive Data in Multi-Hop RF Energy Harvesting Networks (다중 홉 RF 에너지 하베스팅 네트워크에서 지연에 민감한 데이터 전송을 위한 간섭 인지 기반 에너지 효율적인 라우팅 프로토콜)

  • Kim, Hyun-Tae;Ra, In-Ho
    • The Journal of the Korea Contents Association
    • /
    • 제18권3호
    • /
    • pp.611-625
    • /
    • 2018
  • With innovative advances in wireless communication technology, many researches for extending network lifetime in maximum by using energy harvesting have been actively performed on the area of network resource optimization, QoS-guaranteed transmission, energy-intelligent routing and etc. As known well, it is very hard to guarantee end-to-end network delay due to uncertainty of the amount of harvested energy in multi-hop RF(radio frequency) energy harvesting wireless networks. To minimize end-to-end delay in multi-hop RF energy harvesting networks, this paper proposes an energy efficient routing metric based on interference aware and protocol which takes account of various delays caused by co-channel interference, energy harvesting time and queuing in a relay node. The proposed method maximizes end-to-end throughput by performing avoidance of packet congestion causing load unbalance, reduction of waiting time due to exhaustion of energy and restraint of delay time from co-channel interference. Finally simulation results using ns-3 simulator show that the proposed method outperforms existing methods in respect of throughput, end-to-end delay and energy consumption.

A Study on The RFID/WSN Integrated system for Ubiquitous Computing Environment (유비쿼터스 컴퓨팅 환경을 위한 RFID/WSN 통합 관리 시스템에 관한 연구)

  • Park, Yong-Min;Lee, Jun-Hyuk
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • 제49권1호
    • /
    • pp.31-46
    • /
    • 2012
  • The most critical technology to implement ubiquitous health care is Ubiquitous Sensor Network (USN) technology which makes use of various sensor technologies, processor integration technology, and wireless network technology-Radio Frequency Identification (RFID) and Wireless Sensor Network (WSN)-to easily gather and monitor actual physical environment information from a remote site. With the feature, the USN technology can make the information technology of the existing virtual space expanded to actual environments. However, although the RFID and the WSN have technical similarities and mutual effects, they have been recognized to be studied separately, and sufficient studies have not been conducted on the technical integration of the RFID and the WSN. Therefore, EPCglobal which realized the issue proposed the EPC Sensor Network to efficiently integrate and interoperate the RFID and WSN technologies based on the international standard EPCglobal network. The proposed EPC Sensor Network technology uses the Complex Event Processing method in the middleware to integrate data occurring through the RFID and the WSN in a single environment and to interoperate the events based on the EPCglobal network. However, as the EPC Sensor Network technology continuously performs its operation even in the case that the minimum conditions are not to be met to find complex events in the middleware, its operation cost rises. Moreover, since the technology is based on the EPCglobal network, it can neither perform its operation only for the sake of sensor data, nor connect or interoperate with each information system in which the most important information in the ubiquitous computing environment is saved. Therefore, to address the problems of the existing system, we proposed the design and implementation of USN integration management system. For this, we first proposed an integration system that manages RFID and WSN data based on Session Initiation Protocol (SIP). Secondly, we defined the minimum conditions of the complex events to detect unnecessary complex events in the middleware, and proposed an algorithm that can extract complex events only when the minimum conditions are to be met. To evaluate the performance of the proposed methods we implemented SIP-based integration management system.

Design and Implementation of 5G mmWave LTE-TDD HD Video Streaming System for USRP RIO SDR (USRP RIO SDR을 이용한 5G 밀리미터파 LTE-TDD HD 비디오 스트리밍 시스템 설계 및 구현)

  • Gwag, Gyoung-Hun;Shin, Bong-Deug;Park, Dong-Wook;Eo, Yun-Seong;Oh, Hyuk-Jun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • 제27권5호
    • /
    • pp.445-453
    • /
    • 2016
  • This paper presents the implementation and design of the 1T-1R wireless HD video streaming systems over 28 GHz mmWave frequency using 3GPP LTE-TDD standard on NI USRP RIO SDR platform. The baseband of the system uses USRP RIO that are stored in Xilinx Kintex-7 chip to implement LTE-TDD transceiver modem, the signal that are transceived from USRP RIO up or down converts to 28 GHz by using self-designed 28 GHz RF transceiver modules and it is finally communicated HD video data through self-designed $4{\times}8$ sub array antennas. It is that communication method between USRP RIO and Host PC use PCI express ${\times}4$ to minimize delay of data to transmit and receive. The implemented system show high error vector magnitude performance above 25.85 dBc and to transceive HD video in experiment environment anywhere.

Miniaturization of GPS Microstrip Antenna for Small Drone (초소형 드론 탑재용 GPS 대역 마이크로스트립 안테나의 소형화)

  • Kim, Wan-Ki;Woo, Jong-Myung
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • 제21권3호
    • /
    • pp.62-72
    • /
    • 2022
  • In this study, a miniaturized GPS band(L1 : 1.575 GHz) antenna that can be mounted on a small drone is proposed. The miniaturization was designed by applying the perturbation method based on the λ/4 microstrip antenna and lengthening the current path at the edge of the patch. The miniaturized antenna was fabricatred such that it could be attached to the surface of styrofoam(εr=1.06, t=10 mm) having a size of 10 mm × 9 mm × 10 mm (0.05 λ × 0.05 λ × 0.05 λ). The thickness and length of the feeding line and the spacing between short stubs were adjusted for impedance matching. S11 was found to be -18.8 dB at the center frequency of the fabricated antenna, 1.575 GHz. The radiation pattern measurement results show that the maximum gain of Eθ is 1.87 dBi in 0 directions in the xz-plane, and that Eθ is an omnidirectional characteristic with an average gain of -1.7 dBi in the yz-plane. It was found that the antenna can be used as an ultra-small microstrip antenna, which can be mounted on a small dron for GPS, and is capable of preserving a reduction ratio of 98.8% as compared to a λ/2 microstrip patch antenna.

THE CURRENT STATUS OF BIOMEDICAL ENGINEERING IN THE USA

  • Webster, John G.
    • Proceedings of the KOSOMBE Conference
    • /
    • 대한의용생체공학회 1992년도 춘계학술대회
    • /
    • pp.27-47
    • /
    • 1992
  • Engineers have developed new instruments that aid in diagnosis and therapy Ultrasonic imaging has provided a nondamaging method of imaging internal organs. A complex transducer emits ultrasonic waves at many angles and reconstructs a map of internal anatomy and also velocities of blood in vessels. Fast computed tomography permits reconstruction of the 3-dimensional anatomy and perfusion of the heart at 20-Hz rates. Positron emission tomography uses certain isotopes that produce positrons that react with electrons to simultaneously emit two gamma rays in opposite directions. It locates the region of origin by using a ring of discrete scintillation detectors, each in electronic coincidence with an opposing detector. In magnetic resonance imaging, the patient is placed in a very strong magnetic field. The precessing of the hydrogen atoms is perturbed by an interrogating field to yield two-dimensional images of soft tissue having exceptional clarity. As an alternative to radiology image processing, film archiving, and retrieval, picture archiving and communication systems (PACS) are being implemented. Images from computed radiography, magnetic resonance imaging (MRI), nuclear medicine, and ultrasound are digitized, transmitted, and stored in computers for retrieval at distributed work stations. In electrical impedance tomography, electrodes are placed around the thorax. 50-kHz current is injected between two electrodes and voltages are measured on all other electrodes. A computer processes the data to yield an image of the resistivity of a 2-dimensional slice of the thorax. During fetal monitoring, a corkscrew electrode is screwed into the fetal scalp to measure the fetal electrocardiogram. Correlations with uterine contractions yield information on the status of the fetus during delivery To measure cardiac output by thermodilution, cold saline is injected into the right atrium. A thermistor in the right pulmonary artery yields temperature measurements, from which we can calculate cardiac output. In impedance cardiography, we measure the changes in electrical impedance as the heart ejects blood into the arteries. Motion artifacts are large, so signal averaging is useful during monitoring. An intraarterial blood gas monitoring system permits monitoring in real time. Light is sent down optical fibers inserted into the radial artery, where it is absorbed by dyes, which reemit the light at a different wavelength. The emitted light travels up optical fibers where an external instrument determines O2, CO2, and pH. Therapeutic devices include the electrosurgical unit. A high-frequency electric arc is drawn between the knife and the tissue. The arc cuts and the heat coagulates, thus preventing blood loss. Hyperthermia has demonstrated antitumor effects in patients in whom all conventional modes of therapy have failed. Methods of raising tumor temperature include focused ultrasound, radio-frequency power through needles, or microwaves. When the heart stops pumping, we use the defibrillator to restore normal pumping. A brief, high-current pulse through the heart synchronizes all cardiac fibers to restore normal rhythm. When the cardiac rhythm is too slow, we implant the cardiac pacemaker. An electrode within the heart stimulates the cardiac muscle to contract at the normal rate. When the cardiac valves are narrowed or leak, we implant an artificial valve. Silicone rubber and Teflon are used for biocompatibility. Artificial hearts powered by pneumatic hoses have been implanted in humans. However, the quality of life gradually degrades, and death ensues. When kidney stones develop, lithotripsy is used. A spark creates a pressure wave, which is focused on the stone and fragments it. The pieces pass out normally. When kidneys fail, the blood is cleansed during hemodialysis. Urea passes through a porous membrane to a dialysate bath to lower its concentration in the blood. The blind are able to read by scanning the Optacon with their fingertips. A camera scans letters and converts them to an array of vibrating pins. The deaf are able to hear using a cochlear implant. A microphone detects sound and divides it into frequency bands. 22 electrodes within the cochlea stimulate the acoustic the acoustic nerve to provide sound patterns. For those who have lost muscle function in the limbs, researchers are implanting electrodes to stimulate the muscle. Sensors in the legs and arms feed back signals to a computer that coordinates the stimulators to provide limb motion. For those with high spinal cord injury, a puff and sip switch can control a computer and permit the disabled person operate the computer and communicate with the outside world.

  • PDF