• Title/Summary/Keyword: Radiations

Search Result 214, Processing Time 0.028 seconds

The Study for Radio Protection According to a Possible Danger of Exposure During dental X-ray Examination (치과 방사선 검사 시 노출 위험성에 따른 피폭선량 방어연구)

  • Lim, Cheong-Hwan;Kim, Seung-Chul;Jung, Hong-Ryang;Hong, Dong-Hee;You, In-Gyu;Jeong, Cheon-Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.5
    • /
    • pp.237-244
    • /
    • 2011
  • Generally, X-ray examinations for dentistry use low energy radiation. It explains that the radiations are mainly absorbed to a human body because of the weak permeability. We made up some counterplans for decrease in radiation exposure, when guardians and radiologists are overexposed owing to unavoidable circumstances. The equipments for the test are GX-770 and CRANEX TOME CEPH which are used for various exams. Besides we measured the radiations in the projection room and in the control room using model 2026c and 20X6-1800. According to the test, the measurement value in the control room was low dose below $20{\mu}R$, the maximum dose in the projection room was $702.8{\mu}R$ and the measurement value of back dose was higher than lateral one. As the result, if we use a shielding door, it's effective for radioprotection and when we didn't prepare protectors, we should secure appropriate distance and be situated at the side area($90{\sim}135^{\circ}$) on the basis of centeral radiation. That way will provide valuable aid for radioprotection.

The Effects of Urban Forest on Summer Air Temperature in Seoul, Korea (도시림의 여름 대기온도 저감효과 - 서울시를 대상으로 -)

  • 조용현;신수영
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.30 no.4
    • /
    • pp.28-36
    • /
    • 2002
  • The main purpose of this study was to estimate a new regression model to explain the relationship between urban forest and air temperature in summer, 2001. This study consists of two parts: correlation coefficient analysis and regression analysis. According to correlation coefficient analysis, thermal infra-red radiations of the major land use categories found significant difference in each category. However there were no significant relationship between the data (thermal infra-red radiation and NDVI) derived from Landsat-7 ETM+ image and air temperature at Automatic Weather Stations(AWSs). After estimating various regression models for summer air temperature, the final models were chosen. The final regression models consisted of two variables such as forest m and traffic facilities area. The regression models explained over 78% of the variability in air temperatures. The regression models with variables of forest area and traffic facilities area showed that the coefficient of the first variable was even more significant than the second one. However, the negative impact of the traffic facilities area was slightly greater than the positive impact of the forest area. Consequently, the effects of forest area and traffic facilities area were apparent to explain summer air temperature in Seoul. Therefore two policies have the most important implications to mitigate the summer air temperature in Seoul: to expand and to conserve the urban forest; and to change the Oafnc facilities'characteristics. The results from this study are expected to be useful not merely in informing the public that urban forest mitigates summer air temperahne, but in urging the necessity of budgets for trees and managing urban forests. It is recommended that field swey of summer air temperature be Performed for the vadidation of the models. The main purpose of this study was to estimate a new regression model to explain the relationship between urban forest and air temperature in summer, 2001. This study consists of two parts: correlation coefficient analysis and regression analysis. According to correlation coefficient analysis, thermal infra-red radiations of the major land use categories found significant difference in each category. However there were no significant relationship between the data (thermal infra-red radiation and NDVI) derived from Landsat-7 ETM+ image and air temperature at Automatic Weather Stations(AWSs). After estimating various regression models for summer air temperature, the final models were chosen. The final regression models consisted of two variables such as forest m and traffic facilities area. The regression models explained over 78% of the variability in air temperatures. The regression models with variables of forest area and traffic facilities area showed that the coefficient of the first variable was even more significant than the second one. However, the negative impact of the traffic facilities area was slightly greater than the positive impact of the forest area. Consequently, the effects of forest area and traffic facilities area were apparent to explain summer air temperature in Seoul. Therefore two policies have the most important implications to mitigate the summer air temperature in Seoul: to expand and to conserve the urban forest; and to change the traffic facilities'characteristics. The results from this study are expected to be useful not merely in informing the public that urban forest mitigates summer air temperature, but in urging the necessity of budgets for trees and managing urban forests. It is recommended that field survey of summer air temperature be Performed for the vadidation of the models.

Comparison of single-span plastic greenhouse in Korea and high tunnel in North America (우리나라 단동 비닐하우스와 북미지역 하이터널의 비교)

  • Nam, Sang-Woon;Both, Arend-Jan
    • Korean Journal of Agricultural Science
    • /
    • v.38 no.3
    • /
    • pp.505-512
    • /
    • 2011
  • Structural characteristics for standard models of single-span plastic greenhouse in Korea and high tunnels in North America were analyzed, and comparative analysis for greenhouse environments measuring in Korean farmhouse and Rutgers high tunnel was carried out to find structural and environmental improvements of single-span plastic greenhouses that occupy most of Korean greenhouse. Widths of high tunnels are similar to single-span plastic greenhouses but their heights are high comparatively and their side heights are fairly higher than single-span plastic greenhouses specially. Rafters, which are main frames, section sizes of high tunnels are bigger and their intervals are wider than single-span plastic greenhouses. Relative bending resistances compared with representative Korean greenhouse were analyzed by 0.92 to 1.42 in single-span plastic greenhouses, and 1.38 to 2.96 in high tunnels. Frame ratios of single-span plastic greenhouses were 6.8 to 8.6%, and those of high tunnels were 5.5 to 8.7%. We analyzed air temperatures and solar radiations measured in single-span plastic greenhouse and high tunnel on clear days in late March. There were outside temperatures in generally similar range, and judging by rise of indoor temperatures, ventilation performance of high tunnel is more excellent than single-span plastic greenhouse. Solar radiations of two areas were no big difference but light transmittance of high tunnel was a little bit higher than single-span plastic greenhouse. Single-span plastic greenhouses are disadvantageous in environmental managements such as ventilation performance and light transmittance because distance between greenhouses is too narrow and length of greenhouse is too long compared to high tunnels. To get the environmental improvement effects as well as to increase the structural resistance of single-span plastic greenhouses are achievable by widening the width of greenhouse in possible range, widening the space between rafters, and enlarging the section size of rafters. Also, we need to secure enough distance between greenhouses and to restrict the length of greenhouse by maximum 50 m in order to improve the ventilation performance and the light transmittance.

Development of TLD Algorithms by Monochromatic Fluorescence Radiations and Continuous Spectrum X-rays (단일에너지 형광 X선 및 연속 스펙트럼 X선장에 의한 TLD 알고리즘 개발)

  • Kim, Jang-Lyul;Kim, Bong-Hwan;Chang, Si-Young;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.3
    • /
    • pp.159-174
    • /
    • 1998
  • Personal dosimetry system is required to measure the personal dose equivalent accurately in a wide range of radiation fields, but the dose evaluation algorithms have been developed with the X-ray fields described in MOST Ordinance (equivalent to the ANSI N13.11) from which the actual fields to be monitored may be significantly different. To evaluate the dose more accurately when workers are exposed to the non-ANSI N13.11 radiation fields, two algorithms for monochromatic radiations (one algorithm was used for various ratios of TL dosimeter and the other for matrix approximation) were developed with the experimental data of the energy responses of the $CaSO_4:Dy$ TL materials irradiated by monochromatic X-ray fields recently established in KAERI, and compared with the another algorithm developed on the basis of the ANSI N13.11 continuous spectrum X-ray fields. Then it follows the discussions for some results of the algorithm testing including mixed fields irradiations and angular response conducted in IAEA/RCA intercomparison as well as ANSI and ISO continuous spectrum X-ray and monochromatic radiation fields. The developed algorithms were successfully performed the test not only in the continuous spectrum X-ray fields given by MOST Ordinance but also in the several non-MOST Ordinance radiation fields which could be encountered in the practical working environments.

  • PDF

Fault Tolerance Design for Servo Manipulator System Operating in a Hot Cell

  • Jin, Jae-Hyun;Ahn, Sung-Ho;Park, Byung-Suk;Yoon, Ji-Sup;Jung, Jae-Hoo
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.2467-2470
    • /
    • 2003
  • In this paper, fault tolerant mechanisms are presented for a servo manipulator system designed to operate in a hot cell. A hot cell is a sealed and shielded room to handle radioactive materials, and it is dangerous for people to work in the hot cell. So, remote operations are necessary to handle radioactive materials in the hot cell. KAERI has developed a servo manipulator system to perform such remote operations. However, since electric components such as servo motors are weak to radiations, fault tolerant mechanisms have to be considered. For fault tolerance of the servo manipulator system, hardware and software redundancy have been considered. In case of hardware, radioactive resistant electric components such as cables and connectors have been adopted and motors driving a transport have been duplicated. In case of software, a reconfiguration algorithm accommodating one motor's failure has been developed. The algorithm uses redundant axis to recover the end effector's motion in spite of one motor's failure.

  • PDF

Measurement of the Space Radiation Dose for the Flight Aircrew at High-Altitude

  • Lee, Jaewon;Park, Inchun;Kim, Junsik;Lee, Jaejin;Hwang, Junga;Kim, Young-Chul
    • Journal of Astronomy and Space Sciences
    • /
    • v.31 no.1
    • /
    • pp.33-39
    • /
    • 2014
  • This paper describes an experimental approach to evaluate the effective doses of space radiations at high-altitude by combining the measured data from the Liulin-6K spectrometer loaded onto the air-borne RC-800 cockpit and the calculated data from CARI-6M code developed by FAA. In this paper, 15 exposed dose experiments for the flight missions at a high-altitude above 10 km and 3 experiments at a normal altitude below 4 km were executed over the Korean Peninsula in 2012. The results from the high-altitude flight measurements show a dramatic change in the exposed doses as the altitude increases. The effective dose levels (an average of $15.27{\mu}Sv$) of aircrew at the high-altitude are an order of magnitude larger than those (an average of $0.30{\mu}Sv$) of the normal altitude flight. The comparison was made between the measure dose levels and the calculated dose levels and those were similar each other. It indicates that the annual dose levels of the aircrew boarding RC-800 could be above 1 mSv. These results suggest that a proper procedure to manage the exposed dose of aircrew is required for ROK Air Force.

Measurement of relative dose irradiated from a Co-60 source using a scintillating fiber-optic dosimeter (광섬유 방사선량계를 이용한 Co-60 방사선원으로부터 조사되는 상대선량측정)

  • Jang, Kyoung-Won;Cho, Dong-Hyun;Yoo, Wook-Jae;Seo, Jeong-Ki;Heo, Ji-Yeon;Lee, Bong-Soo;Shin, Sang-Hun;Park, Byung-Gi;Kim, Sin
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.1
    • /
    • pp.52-57
    • /
    • 2010
  • In this study, we have fabricated a scintillating fiber-optic dosimeter for a radiotherapy dosimetry. And ${\gamma}$-rays generated by a Co-60 are measured using a scintillating fiber-optic dosimeter and percent depth dose curves are obtained according to the different depths of solid water phantoms. Also, Cerenkov radiations generated by primary or secondary electrons are measured at different depths of water phantom using a background optical fiber.

Lung Perfusion Imaging and $Tc^{99m}-Macroaggregated$ Human Serum Albumin

  • Haider, Kh.H.;Ilyas, M.;Hyder, Q.;Kim, Chong-Kook
    • Journal of Pharmaceutical Investigation
    • /
    • v.31 no.2
    • /
    • pp.73-80
    • /
    • 2001
  • Lung perfusion scanning, invariably combined with ventilation studies provides a reliable and non-invasive mean to diagnose lung related pathologies despite the availability of modern techniques such as angiography, magnetic resonance imaging, magnetic resonance angiography, and helical (spiral) computed tomography. The technique involves the generation of images by radiations emitted from radioisotopes introduced in to the lungs. Various radiopharmaceuticals have been proposed and designed to incorporate $Tc^{99m}$ in to macroparticulate form for lung perfusion imaging. However, most of these have associated difficulties such as reproducibility of the product with regards to particle size distribution and poor elimination from the lung capillary bed. $Tc^{99m}$ macroaggregated albumin $(Tc^{99m}-MAA)$ is used extensively for clinical lung perfusion imaging and is considered as the radiopharmaceutical of choice. It is non-toxic, safe, and being biodegradable, is easily eliminated from the lung capillary bed by proteolytic enzyme metabolism and by mechanical forces due to lung movement.

  • PDF

Dose-Incidence Relationships on the Prenatal Effects of Gamma-Radiation

  • Kim, Sung-Ho;Lee, Jong-Hwan;Oh, Heon;Kim, Se-Ra;Jo, Sung-Kee;Kim, Tae-Hwan;Lee, Yun-Sil;Lee, Cha-Soo
    • Proceedings of the Korean Society of Veterinary Pathology Conference
    • /
    • 2001.09a
    • /
    • pp.21-21
    • /
    • 2001
  • The objective of this investigation was to evaluate of dose-incidence relationships on the prenatal effects of gamma-radiation. Pregnant ICR mice were exposed on day 11.5 after conception, coincident with the most sensitive stage for the induction of major congenital malformations, with 0.5-4.0 Gy of gamma-radiations. The animals were sacrificed on day 18 of gestation and the fetuses were examined for mortality, growth retardation, change in head size and any other morphological abnormalities. With increasing radiation dose, incidence of small head, growth retarded fetus, cleft palate, dilatation of cerebral ventricle and abnormalities of the extremities in live fetuses rose. The threshold doses of radiation that induced cleft palate and dilatation of cerebral ventricle, and abnormal extremities were between 1.0 and 2.0 Gy, and between 0.5 and 1.0 Gy, respectively.

  • PDF

ELINT Intra-pulse Modulation Recognition using Fuzzy Algorithm (퍼지 알고리즘을 이용한 전자정보의 펄스 내 변조 인식)

  • Kim, Young-Min
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.9
    • /
    • pp.1986-1995
    • /
    • 2013
  • The ELINT system which derives intelligence from electromagnetic radiations plays an important role in modern electric warfares. Among radar characteristics inferred from the signals, intra-pulse modulation scheme is a useful feature to identify modern radars. This paper proposes the method to classify intra-pulse modulation schemes such as UM, PSK, BFSK, QFSK, LFM and NLFM based on the fuzzy algorithm. The proposed method defines fuzzy membership functions to characterize input signals, and then it calculates accordance rates for each modulation scheme with fuzzy inference rules. The experimental results show that the probability of correct recognition is more than 95% for SNR > 10dB.