• Title/Summary/Keyword: Radiation sensitivity

Search Result 576, Processing Time 0.026 seconds

Evaluation of Residential Radiation Doses from Korean Atomic Power Plants - Effect of Socioenvironmental Inputs (국내 원전주변 주민 방사선 피폭선량 평가 - 입력변수의 영향)

  • 조대철;이갑복
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.4 no.3
    • /
    • pp.223-229
    • /
    • 2003
  • Annual radiation dose of residential individuals near 4 nuclear power plants in Korea was calculated via K-DOSE 60 based on the updated ICRP-60. The critical exposure variables were chosen as radionuclides, exposed organs and intake pathways. From the calculation results, the critical nuclides were found to be $^3$H, $^{133}$ Xe, $^{60}$ Co for Kori plants and $^{14}$ C, $^{41}$ Ar for Wolsung plants. The most critical pathway was 'vegetable intake' for adults and 'milk intake' for infants. However, there was no preference in the effective organs. Sensitivity analyses showed that the chemical composition in a nuclide much more influenced upon the radiation dose than any other input parameters such as food intake, radiation discharge, and transfer/concentration coefficients by more than 10$^2$ factor. The effect of transfer/concentration coefficients on the radiation dose was negligible. All input parameters showed highly estimated correlation with the radiation dose, approxinated to 1.0.

  • PDF

Radiation Effects on Fiber Bragg Grating Sensors by Irradiation Conditions of UV Laser (UV 레이저 노출조건에 따른 FBG 센서의 방사선 영향)

  • Kim, Jong-Yeol;Lee, Nam-Ho;Jung, Hyun-Kyu
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.12
    • /
    • pp.2310-2316
    • /
    • 2016
  • We studied the effect of $Co^{60}$ gamma-radiation on the fiber Bragg gratings (FBGs) by irradiation time of UV Krypton fluoride (KrF) excimer laser among grating processing parameters. The FBGs were fabricated in a different UV laser irradiation time at 30, 60, 90, and 120 seconds using the same commercial Ge-doped silica core fiber (SMF-28e). It was exposed to gamma-radiation up to a high dose of 34.3 kGy at the dose rate of 106 Gy/min, and then it was analyzed radiation effects by measuring the radiation-induced change in the temperature sensitivity coefficient and Bragg wavelength shift. According to the experimental results, We confirmed that the UV laser irradiation period for grating inscription has a highly effect on the radiation sensitivity of the FBGs. The radiation-induced Bragg wavelength shift by the change of laser irradiation conditions showed a difference more than about 50 %.

Development of Electronic Personal Dosimeter with Hybrid Preamplifier using Semiconductor Detector (반도체 검출기를 이용한 Hybrid 전치증폭기형 전자식 개인선량계 개발)

  • Lee, B.J.;Kim, B.H.;Chang, S.Y.;Kim, J.S.;Rho, S.R.
    • Journal of Radiation Protection and Research
    • /
    • v.27 no.1
    • /
    • pp.51-57
    • /
    • 2002
  • An electronic personal dosimeter(EPD) with hybrid type preamplifier adopting a semiconductor detector as a radiation detector has been developed, manufactured and test-evaluated. The radiation detection characteristics of this EPD has been performance-tested by using a reference photon radiation field. After several test-irradiations to a $^{137}Cs$ gamma radiation source the radiation detection sensitivity of this EPD appeared to be $3.8\;cps/Gy{\cdot}h^{-1}$. The linearity of radiation response was kept within 8% of the dose equivalent ranges of $10{\mu}Sv{\sim}4Sv$ and the angular dependence was under less than 4% in angles of ${\pm}60^{\circ}$. It was confirmed that the energy response range was in $60{\sim}1,250keV$ given in the ISO standard. This EPD satisfied the international criteria for the EPD in the mechanical and the environmental performance test for 9 test categories according to IEC 61526.

Radio-sensitivity Analysis and Selection of Useful Mutants of Rape (Brassica napus L.) by Gamma Irradiation (방사선 처리에 의한 유채의 생육 및 감수성 조사)

  • Goh, Eun Jeong;Kim, Wook-Jin;Kim, Jin-Baek;Kim, Dong Sub;Kim, Sang Hoon;Kang, Si-Yong
    • Journal of Radiation Industry
    • /
    • v.4 no.3
    • /
    • pp.277-283
    • /
    • 2010
  • Rape (Brassica napus L.) plants are one of the major oilseed crops. The main components of rapeseed are oil (35 to 47%) and protein (15 to 32%). For the biodiesel production, the development of a new variety of rape plant with high biomass and/or oleic acid contents is required. In order to determine the optimum dose of gamma-ray irradiation, the rape seeds of cvs. Hanra (Hr), Youngsan (Ys), Tammi (Tm), and Tamra (Tr) were irradiated with a 100~4,000 Gy dose range of gamma-rays. Considering the growth factors, the optimum doses were determined to be within the range of 600~1,000 Gy for the selection of useful mutant lines. Six-hundred and eighty-eight (688) $M_2$ mutant lines were obtained from 600~1,000 Gy gamma-ray-irradiated $M_1$ plants through selfing. The growth characteristics, leaf shape, early flowering, and flower color were all investigated. The selected mutant numbers of early flowering, leaf shape, and flower color were 34, 52, and 3 from the four cultivars, respectively. These mutant lines will be used for the development of a new variety of rape plant with high biomass and oleic acid contents.

Characteristics of the Contact Angle Using the Microwave Plasma Treatment on Scintillator Panel Substrates (마이크로웨이브 플라즈마 처리를 통한 섬광체 패널 기판의 접촉가 특성변화)

  • Kim, Byoungwook;Kim, Youngju;Ryu, Cheolwoo;Choi, Byoungjung;Kwon, Youngman;Lee, Youngchoon;Kim, Myungsoo;Cho, Gyuseong
    • Journal of Radiation Industry
    • /
    • v.8 no.1
    • /
    • pp.43-47
    • /
    • 2014
  • By measuring decrease change of the contact angle after microwave plasma treatment on the glass and Al as a scintillator panel sample substrate, the adhesive performance of scintillator panel can be expected to improve. Also resolution and sensitivity of scintillator panel after microwave plasma treatment can be expected to maintain highly.

Diagnostic Value of 18F-FDG PET/CT in Comparison to Bone Scintigraphy, CT and 18F-FDG PET for the Detection of Bone Metastasis

  • Liu, Ning-Bo;Zhu, Lei;Li, Ming-Huan;Sun, Xiao-Rong;Hu, Man;Huo, Zong-Wei;Xu, Wen-Gui;Yu, Jin-Ming
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.6
    • /
    • pp.3647-3652
    • /
    • 2013
  • Purpose: To evaluate the diagnostic value of $^{18}F$-FDG PET/CT for detection of bone metastasis in comparison with the efficacies of $^{18}F$-FDG PET/CT, CT, $^{18}F$-FDG PET and conventional planar bone scintigraphy in a series of cancer patients. Methods: Five hundred and thirty patients who underwent both $^{18}F$-FDG PET/CT and bone scintigraphy within 1 month were retrospectively analyzed. The skeletal system was classified into 10 anatomic segments and interpreted blindly and separately. For each modality, the sensitivity, specificity, accuracy, PPV and NPV were calculated and the results were statistically analyzed. Results: Bone metastases were confirmed in 117 patients with 459 positive segments. On patient-based analysis, the sensitivity, specificity, accuracy, PPV and NPV of $^{18}F$-FDG PET/CT were significantly higher than bone scintigraphy, CT and $^{18}F$-FDG PET (P<0.05). On segment-based analysis, the sensitivity of CT, bone scintigraphy, $^{18}F$-FDG PET and $^{18}F$-FDG PET/CT were 70.4%, 89.5%, 89.1% and 97.8%, respectively (P<0.05, compared with $^{18}F$-FDG PET/CT). The overall specificity and accuracy of the four modalities were 89.1%, 91.8%, 90.3%, 98.2% and 90.3%, 90.9%, 89.8%, 98.0%, respectively (P<0.05, compared with $^{18}F$-FDG PET/CT). The PPV and NPV were 89.8%, 87.6%, 85.6%, 97.2% and 85.6%, 93.2%, 92.8%, 98.6%, respectively. Three hundred and twelve lesions or segments were presented as lytic or sclerotic changes on CT images at the corresponding sites of increased $^{18}F$-FDG uptake. In lytic or mixed lesions, the sensitivity of $^{18}F$-FDG PET/CT and $^{18}F$-FDG PET were better than bone scintigraphy, while in osteoblastic lesions bone scintigraphy had a similar performance with $^{18}F$-FDG PET/CT but better than $^{18}F$-FDG PET alone. Conclusion: Our data allow the conclusion that $^{18}F$-FDG PET/CT is superior to planar bone scintigraphy, CT or $^{18}F$-FDG PET in detecting bone metastasis. $^{18}F$-FDG PET/CT may enhance our diagnosis of tumor bone metastasis and provide more information for cancer treatment.

Development of charge sensitive amplifiers based on various circuit board substrates and evaluation of radiation hardness characteristics

  • Jeong, Manhee;Kim, Geehyun
    • Nuclear Engineering and Technology
    • /
    • v.52 no.7
    • /
    • pp.1503-1510
    • /
    • 2020
  • Ultra-low noise charge sensitive amplifiers (CSAs) based on various types of circuit board substrates, such as FR4, Teflon, and ceramics (Al2O3) with two different designs, PA1 and PA2, have been developed. They were tested to see the noise effect from the dielectric loss of the substrate capacitance before and after irradiation. If the electronic noise from the CSAs is to be minimized and the energy resolution enhanced, the shaping time has to be optimized for the detector, and a small feedback capacitance of the CSA is favorable for a better SNR. Teflon- and ceramic-based PA1 design CSAs showed better noise performance than the FR4-based one, but the Teflon-based PA1 design showed better sensitivity than ceramic based one at a low detector capacitance (<10 pF). In the PA2 design, the equivalent noise and the sensitivity were 0.52 keV FWHM for a silicon detector and 7.2 mV/fC, respectively, with 2 ㎲ peaking time and 0.1 pF detector capacitance. After 10, 100, 103, 104, and 105 Gy irradiation the ENC and sensitivity characteristics of the developed CSAs based on three different substrate materials are also discussed.

Sensitivity Analyses of the Meteorological Factors in the Estimation of Evapotranspiration Rates (증발산량 산정에 있어서 기상학적 요인들의 민감도 해석)

  • 임창수
    • Journal of Environmental Science International
    • /
    • v.5 no.5
    • /
    • pp.657-662
    • /
    • 1996
  • Meteorological and flux data measured from semiarid watersheds (Lucky Hills and Kendall) during the summer rainy and winter periods were used to study the sensitivity of the those variables used in the estimation of evapotranspiration rates. Relative sensitivity was examined to compare the importance of four meteorological and flux variables (net radiation wind speed, air temperature, and relative humidity) on Penman potential evapotranspiration (PET) estimation. The study results show that variations in Penman PET rates during the summer rainy period at both watersheds appears to be controlled by air temperature adn net radiation. During the winter period at both watersheds, wariations in Penman PET rates appears to be controlled by relative humidity and air temperature.

  • PDF

Radiation effect on the polymer-based capacitive relative humidity sensors

  • Shchemerov, I.V.;Legotin, S.A.;Lagov, P.B.;Pavlov, Y.S.;Tapero, K.I.;Petrov, A.S.;Sidelev, A.V.;Stolbunov, V.S.;Kulevoy, T.V.;Letovaltseva, M.E.;Murashev, V.N.;Konovalov, M.P.;Kirilov, V.N.
    • Nuclear Engineering and Technology
    • /
    • v.54 no.8
    • /
    • pp.2871-2876
    • /
    • 2022
  • The sensitivity of polymer-based capacitive relative humidity (RH) sensors after irradiation with neutrons, electrons and protons was measured. Degradation consists of the decreasing of the upper RH limit that can be measured. At the same time, low RH-level sensitivity is almost stable. After 30 krad of absorption dose, RH cut off is equal to 85% of max value, after 60 krad-40%. Degradation reduces after annealing which indicates high radiation sensitivity of the internal circuit in comparison to RH-sensing polymer film.