• Title/Summary/Keyword: Radiation monitoring system

Search Result 234, Processing Time 0.029 seconds

Development of a muon detector based on a plastic scintillator and WLS fibers to be used for muon tomography system

  • Chanwoo Park;Kyu Bom Kim;Min Kyu Baek;In-soo Kang;Seongyeon Lee;Yoon Soo Chung;Heejun Chung;Yong Hyun Chung
    • Nuclear Engineering and Technology
    • /
    • v.55 no.3
    • /
    • pp.1009-1014
    • /
    • 2023
  • Muon tomography is a useful method for monitoring special nuclear materials (SNMs) such as spent nuclear fuel inside dry cask storage. Multiple Coulomb scattering of muons can be used to provide information about the 3-dimensional structure and atomic number(Z) of the inner materials. Tomography using muons is less affected by the shielding material and less harmful to health than other measurement methods. We developed a muon detector for muon tomography, which consists of a plastic scintillator, 64 long wavelength-shifting (WLS) fibers attached to the top of the plastic scintillator, and silicon photomultipliers (SiPMs) connected to both ends of each WLS fiber. The muon detector can acquire X and Y positions simultaneously using a position determination algorithm. The design parameters of the muon detector were optimized using DETECT2000 and Geant4 simulations, and a muon detector prototype was built based on the results. Spatial resolution measurement was performed using simulations and experiments to evaluate the feasibility of the muon detector. The experimental results were in good agreement with the simulation results. The muon detector has been confirmed for use in a muon tomography system.

Correlation Between Exposure Rate and Quasi-Effective Energy of Natural Radiation in Japan -TLD Application-

  • Nakajima, Toshiyuki
    • Journal of Radiation Protection and Research
    • /
    • v.12 no.1
    • /
    • pp.54-60
    • /
    • 1987
  • The quasi-exposure rate and the quasi-effective energy of the natural radiation in the field at 47 monitoring points around nuclear power plants have been studied with the pair filter thermoluminescence dosimeter system. The results of the six years observation showed that the relationship between the quasi-exposure rate $X_q$, and quasi-effective energy $E_q$ can be represented as a hyperbolic function: $X_q=A+C/(E_q-B)$, where the constants A and B correspond to the quasi-exposure rate of cosmic-rays and the minimum quasi-effective energy of natural radiation, respectively. Furthermore, the constant A is in close agreement with the values obtained by using ionization chambers and scintillation detectors. The constant B is approximately 0.68 MeV, closely corresponding to the mean energy of the photons emitted from natural uranium.

  • PDF

A study of an environmental radiation monitoring system(ERMS) using digital single channel analyzer(SCA) and dose conversion unit(DCU) (디지털 SCA와 DCU를 이용한 환경방사선 감시기에 관한 연구)

  • 오길환;우희곤;이쾌희;하달규
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.1372-1375
    • /
    • 1996
  • In this paper, we developed and ERMS, which monitors radiation continuously in the vicinity of the nuclear power plant not only to intend health and security of the adjacent residents but also to prevent environmental pollution. Especially, applying digital DCU and SCA which are easy to control and accurate, we obtained good results.

  • PDF

Statistical Analysis of Count Rate Data for On-line Seawater Radioactivity Monitoring

  • Lee, Dong-Myung;Cong, Binh Do;Lee, Jun-Ho;Yeo, In-Young;Kim, Cheol-Su
    • Journal of Radiation Protection and Research
    • /
    • v.44 no.2
    • /
    • pp.64-71
    • /
    • 2019
  • Background: It is very difficult to distinguish between a radioactive contamination source and background radiation from natural radionuclides in the marine environment by means of online monitoring system. The objective of this study was to investigate a statistical process for triggering abnormal level of count rate data measured from our on-line seawater radioactivity monitoring. Materials and Methods: Count rate data sets in time series were collected from 9 monitoring posts. All of the count rate data were measured every 15 minutes from the region of interest (ROI) for $^{137}Cs$ ($E_{\gamma}=661.6keV$) on the gamma-ray energy spectrum. The Shewhart ($3{\sigma}$), CUSUM, and Bayesian S-R control chart methods were evaluated and the comparative analysis of determination methods for count rate data was carried out in terms of the false positive incidence rate. All statistical algorithms were developed using R Programming by the authors. Results and Discussion: The $3{\sigma}$, CUSUM, and S-R analyses resulted in the average false positive incidence rate of $0.164{\pm}0.047%$, $0.064{\pm}0.0367%$, and $0.030{\pm}0.018%$, respectively. The S-R method has a lower value than that of the $3{\sigma}$ and CUSUM method, because the Bayesian S-R method use the information to evaluate a posterior distribution, even though the CUSUM control chart accumulate information from recent data points. As the result of comparison between net count rate and gross count rate measured in time series all the year at a monitoring post using the $3{\sigma}$ control charts, the two methods resulted in the false positive incidence rate of 0.142% and 0.219%, respectively. Conclusion: Bayesian S-R and CUSUM control charts are better suited for on-line seawater radioactivity monitoring with an count rate data in time series than $3{\sigma}$ control chart. However, it requires a continuous increasing trend to differentiate between a false positive and actual radioactive contamination. For the determination of count rate, the net count method is better than the gross count method because of relatively a small variation in the data points.

Development of the ZnS(Ag)/BC-408 phoswich detector for monitoring radioactive contamination inside pipes (배관 내부 방사능 오염도 측정용 ZnS(Ag)/BC-408 phoswich 검출기 개발)

  • Kim, Gye-Hong;Park, Chan-Hee;Jung, Chong-Hun;Lee, Kune-Woo;Seo, Bum-Kyoung
    • Journal of Radiation Protection and Research
    • /
    • v.31 no.3
    • /
    • pp.123-128
    • /
    • 2006
  • A small radiation detection system is necessary for the direct characterization of alpha/beta-ray contamination inside pipes generated during the decommission of a nuclear facility. In this work, the new type phoswich detector consisting of the ZnS(Ag) and plastic scintillator for ${\alpha}/{\beta}$ simultaneous counting was designed as part of a development of a equipment capable of monitoring radiological contamination inside pipes. The optimum counting conditions in dimensions of scintillator and a detection system were experimentally confirmed and a performance of alpha/beta-ray discrimination was evaluated. As a result, optimum conditions of a detector suitable for monitoring radiological contamination inside pipes and a feasibility of application to pipe-inside were confirmed.

Development of a Greenhouse Monitoring System Using Network (네트워크를 이용한 온실 감시 시스템의 개발)

  • 임정호;류관희;진제용
    • Journal of Biosystems Engineering
    • /
    • v.28 no.1
    • /
    • pp.53-58
    • /
    • 2003
  • This study was carried out to design, construct, and test a greenhouse monitoring system fur the environment and status of control devices in a greenhouse from a remote site using internet. The measuring items selected out of many environmental factors were temperature, humidity, solar radiation, CO$_2$, SOx, NOx concentration, EC, pH of nutrient solution, the state of control devices, and the image of greenhouse. The developed greenhouse monitoring system was composed of the network system and the measuring module. The network system consists of the three kinds of monitors named the Croup Monitor. the Client Monitor and the Server Monitor. The results of the study are summarized as follows. 1. The measuring module named the House Monitor. which is used to watch the state of the control device and the environment of the greenhouse, was developed to a embedded monitoring module using one chip microprocessor 2. For all measuring items. the House Monitor showed a satisfactory accuracy within the range of ${\pm}$0.3%FS. The House Monitors were connected to the Croup Monitor by communication method of RS-485 type and could operate under power and communication fault condition within 10 hours. The Croup Monitor was developed to receive and display measurement data received from the House Monitors and to control the greenhouse environmental devices. 3. The images of the plants inside greenhouse were captured by PC camera and sent to the Group Monitor. The greenhouse manager was able to monitor the growth state of plants inside greenhouse without visiting individual greenhouses. 4. Remote monitoring the greenhouse environment and status of control devices was implemented in a client/server environment. The client monitor of the greenhouse manager at a remote site or other greenhouse manager was able to monitor the greenhouse environment and the state of control devices from the Server Monitor using internet.

A Mobile Robot for Remote Inspection of Radioactive Waste (방사선폐기물 원격감시용 이동로봇)

  • 서용칠;김창회;조재완;최영수;김승호
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2004.06a
    • /
    • pp.430-432
    • /
    • 2004
  • Tele-operation and remote monitoring techniques are essential and important technologies for the inspection and maintenance of the radioactive waste. A mobile robot has been developed for the application of remote monitoring and inspection of nuclear facilities, where human access is limited because of the high-level radioactive environments, The mobile robot was designed with reconfigurable crawler type of wheels attached on the front and rear side in order to pass through the ditch, The extendable mast, mounted on the mobile robot, car be extended up to 8 m vertically. The robust controller for radiation is designed in focus on electric components to prevent abnormal operation in a highly radioactivated area during reactor operation, This robot system will enhance the reliability of nuclear power facilities, and cope with the unexpected radiation accident.

  • PDF

Development of Prototype Liquid Scintillator System for Monitoring Liquid Radioactive Waste (배수 모니터링 액체섬광검출시스템의 프로토 타입 개발)

  • Nam, Uk-Won;Seon, Kwang-Il;Kong, Kyoung-Nam;Kim, Chang-Kyu;Lee, Dong-Myung;Lee, Sang-Kook
    • Journal of Radiation Protection and Research
    • /
    • v.28 no.3
    • /
    • pp.173-182
    • /
    • 2003
  • A prototype liquid scillatillator system for measurement of multiple beta-labeled mixtures was developed and its characteristic was investigated. The signal processing system consists of two photomultiplier tubes and the coincident count circuit. The characteristic of the system was analyzed using 4 beta-labeled samples $(^3H,\;^{14}C,\;^{36}Cl\;and\;^{90}Sr)$. Beta spectra from the samples were obtained without radiation shielding, and the detection limits for each nuclides were estimated based on the spectra. The estimated detection limits were compared to the legal regulation values. It is found that the liquid radioactive nuclides are detectable well below the legal regulation values.

In-House Developed Surface-Guided Repositioning and Monitoring System to Complement In-Room Patient Positioning System for Spine Radiosurgery

  • Kim, Kwang Hyeon;Lee, Haenghwa;Sohn, Moon-Jun;Mun, Chi-Woong
    • Progress in Medical Physics
    • /
    • v.32 no.2
    • /
    • pp.40-49
    • /
    • 2021
  • Purpose: This study aimed to develop a surface-guided radiosurgery system customized for a neurosurgery clinic that could be used as an auxiliary system for improving the accuracy, monitoring the movements of patients while performing hypofractionated radiosurgery, and minimizing the geometric misses. Methods: RGB-D cameras were installed in the treatment room and a monitoring system was constructed to perform a three-dimensional (3D) scan of the body surface of the patient and to express it as a point cloud. This could be used to confirm the exact position of the body of the patient and monitor their movements during radiosurgery. The image from the system was matched with the computed tomography (CT) image, and the positional accuracy was compared and analyzed in relation to the existing system to evaluate the accuracy of the setup. Results: The user interface was configured to register the patient and display the setup image to position the setup location by matching the 3D points on the body of the patient with the CT image. The error rate for the position difference was within 1-mm distance (min, -0.21 mm; max, 0.63 mm). Compared with the existing system, the differences were found to be as follows: x=0.08 mm, y=0.13 mm, and z=0.26 mm. Conclusions: We developed a surface-guided repositioning and monitoring system that can be customized and applied in a radiation surgery environment with an existing linear accelerator. It was confirmed that this system could be easily applied for accurate patient repositioning and inter-treatment motion monitoring.

Multi-Radioactivity Measurement System Design for Indoor Environmental Monitoring (실내 환경 모니터링을 위한 다중 방사능계측 시스템 설계)

  • Sagong, Byung-Il;Kim, Nam-Ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.05a
    • /
    • pp.459-461
    • /
    • 2022
  • In this paper, we propose a measurement system for measuring radioactivity detected in an indoor environment. This is to measure and prevent radiation generated in various spaces such as general house, workplace, and research institutes. Multi-radioactivity sensors are used to measure multiple spaces simultaneously. The measured radioactivity data is transmitted to the PC in real time through ZigBee and monitored. Even with a small amount of radioactivity, it is considered that it must be installed in a place where radiation exposure is expected, such as a laboratory or workplace, for prevention from chronic radiation syndrome.

  • PDF