• Title/Summary/Keyword: Radiation medicine

Search Result 3,968, Processing Time 0.036 seconds

Evaluation on Medical Application of Survey meters in Convergence Perspective for the Efficient Disaster Responses in the Massive Radiological Disasters: A Simulation Study of Externally Contaminated Patients Using Two Representative type of Survey-Meters (융합적 관점에서 본 대량방사선 재난에서 효율적 재난반응을 위한 오염감시기의 의학적 적용에 대한 평가: 대표적 두가지 오염감시기를 이용한 방사선외부오염환자 시뮬레이션 연구)

  • Kim, Chu Hyun
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.3
    • /
    • pp.77-83
    • /
    • 2021
  • The purpose of the study is to evaluate the effect on medical application and convergence for the efficient disaster responses in the massive radiological events by comparison of two types of survey-meters(hand held survey-meter and transportable portal monitor). In the simulated radiation disaster drill, twelve participants randomly wore a personal protective equipments (PPE) with twelve check source. We measured participants to detect five real radioactive sources of the twelve check sources, using two types of survey meters. The primary outcome was the measuring time. The secondary outcome was the sensitivity and specificity of the detection of the real radioactive source. The average time by the hand held survey meter was 231.9 ± 116.6 seconds, and the time by transportable portal monitor was statistically shorter 8.690 ± 1.667 seconds. There was no difference in the sensitivity and specificity between two survey meters. The transportable portal monitor survey meter was considered to have medical application and play an important role in radiological disasters.

Autonomic Nerve Change after Loess Bedding Radiating Far-infrared ray and energy (원적외선에너지 방출 황토침구 사용 후의 자율신경 변화에 대한 연구)

  • Lee, Ku Yeon;Lee, Hyung H.;Hahm, Suk Chan
    • Journal of Naturopathy
    • /
    • v.9 no.1
    • /
    • pp.27-32
    • /
    • 2020
  • Purpose: The purpose of this study was to investigate the changes in the autonomic nervous system of the human body after the use of ocher bedding radiating far-infrared rays to 15 insomnia subjects. Methods: Changes of autonomous nerve in the subjects after using loess bedding estimated by heart rate variability. Results: The mean HF before the use of ocher bedding was 220.8 msec2, and the mean after use decreased to 5.1 msec2. The average value of LF before use was 418.1 msec2, and the mean after use decreased to 5.2 msec2. The average before use of the VLF was 1463.3 msec2, and the average after use dropped to 6.8 msec2. The average value of TP before use was 977.3 msec2, and the average after use dropped to 6.7 msec2. The decrease in postoperative values of all four items was statistically significant, and the high value of the subjects before use inferred to be the reason that all of the subjects had high stress and anxiety due to their long-term sleep disorder. There was no significant difference in the pulses of the subjects before the use of the bedding. SDNN and RMSSD were not significantly different before and after use. Conclusions: Autonomic nerves HF, LF, VLF, TP frequency is evaluated to be affected by the investigation of far-infrared radiation that occurs ocher. This research data regarded as high value as primary data in this field.

Development of a polystyrene phantom for quality assurance of a Gamma Knife®

  • Yona Choi;Kook Jin Chun;Jungbae Bahng;Sang Hyoun Choi;Gyu Seok Cho;Tae Hoon Kim;Hye Jeong Yang;Yeong Chan Seo;Hyun-Tai Chung
    • Nuclear Engineering and Technology
    • /
    • v.55 no.8
    • /
    • pp.2935-2940
    • /
    • 2023
  • A polystyrene phantom was developed following the guidance of the International Atomic Energy Association (IAEA) for gamma knife (GK) quality assurance. Its performance was assessed by measuring the absorbed dose rate to water and dose distributions. The phantom was made of polystyrene, which has an electron density (1.0156) similar to that of water. The phantom included one outer phantom and four inner phantoms. Two inner phantoms held PTW T31010 and Exradin A16 ion chambers. One inner phantom held a film in the XY plane of the Leksell coordinate system, and another inner phantom held a film in the YZ or ZX planes. The absorbed dose rate to water and beam profiles of the machine-specific reference (msr) field, namely, the 16 mm collimator field of a GK PerfexionTM or IconTM, were measured at seven GK sites. The measured results were compared to those of an IAEA-recommended solid water (SW) phantom. The radius of the polystyrene phantom was determined to be 7.88 cm by converting the electron density of the plastic, considering a water depth of 8 g/cm2. The absorbed dose rates to water measured in both phantoms differed from the treatment planning program by less than 1.1%. Before msr correction, the PTW T31010 dose rates (PTW Freiberg GmbH, New York, NY, USA) in the polystyrene phantom were 0.70 (0.29)% higher on average than those in the SW phantom. The Exradin A16 (Standard Imaging, Middleton, WI, USA) dose rates were 0.76 (0.32)% higher in the polystyrene phantom. After msr correction factors were applied, there were no statistically significant differences in the A16 dose rates measured in the two phantoms; however, the T31010 dose rates were 0.72 (0.29)% higher in the polystyrene phantom. When the full widths at half maximum and penumbras of the msr field were compared, no significant differences between the two phantoms were observed, except for the penumbra in the Y-axis. However, the difference in the penumbra was smaller than variations among different sites. A polystyrene phantom developed for gamma knife dosimetry showed dosimetric performance comparable to that of a commercial SW phantom. In addition to its cost effectiveness, the polystyrene phantom removes air space around the detector. Additional simulations of the msr correction factors of the polystyrene phantom should be performed.

Shielding Performance of PLA and Tungsten Mixture using Research Extruder (연구용 압출기를 활용한 PLA와 텅스텐 혼합물의 차폐 성능)

  • Do-Seong Kim;Tae-Hyung Kim;Myeong-Seong Yoon;Sang-Hyun Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.4
    • /
    • pp.557-564
    • /
    • 2023
  • In this study, 3D printing technology was used to compensate for the shortcomings of the use of lead, which has proven to have excellent shielding performance, and to control unnecessary human exposure. 3D printers can implement three-dimensional shapes and can immediately apply individual ideas, which has great advantages in maintaining technology supplementation while reducing the cost and duration of prototyping. Among the various special 3D printers, the FDM method was adopted, and the filament used for output was manufactured using a research extruder by mixing two materials, PLA (Poly-Lactic-Acid) and tungsten. The purpose was to verify the validity through dose evaluation and to provide basic information on the production of chapezones of various materials. The mixed filament was implemented as a morphological shield. Filaments made of a research extruder by mixing PLA and tungsten were divided into 10 %, 20 %, 30 %, 40 %, and 50 % according to the tungsten content ratio. Through the process of 3D Modeling, STL File storage, G-code generation, and output, 10 cm × 10 cm × 0.5 cm was manufactured, respectively, and dose and shielding ability were evaluated under the conditions of tube voltages of 60 kVp, 80 kVp, 100 kVp, 120 kVp, and tube currents of 20 mAs and 40 mAs.

Added Value of Contrast Leakage Information over the CBV Value of DSC Perfusion MRI to Differentiate between Pseudoprogression and True Progression after Concurrent Chemoradiotherapy in Glioblastoma Patients

  • Pak, Elena;Choi, Seung Hong;Park, Chul-Kee;Kim, Tae Min;Park, Sung-Hye;Won, Jae-Kyung;Lee, Joo Ho;Lee, Soon-Tae;Hwang, Inpyeong;Yoo, Roh-Eul;Kang, Koung Mi;Yun, Tae Jin
    • Investigative Magnetic Resonance Imaging
    • /
    • v.26 no.1
    • /
    • pp.10-19
    • /
    • 2022
  • Purpose: To evaluate whether the added value of contrast leakage information from dynamic susceptibility contrast magnetic resonance imaging (DSC MRI) is a better prognostic imaging biomarker than the cerebral blood volume (CBV) value in distinguishing true progression from pseudoprogression in glioblastoma patients. Materials and Methods: Forty-nine glioblastoma patients who had undergone MRI after concurrent chemoradiotherapy with temozolomide were enrolled in this retrospective study. Twenty features were extracted from the normalized relative CBV (nCBV) and extraction fraction (EF) map of the contrast-enhancing region in each patient. After univariable analysis, we used multivariable stepwise logistic regression analysis to identify significant predictors for differentiating between pseudoprogression and true progression. Receiver operating characteristic (ROC) analysis was employed to determine the best cutoff values for the nCBV and EF features. Finally, leave-one-out cross-validation was used to validate the best predictor in differentiating between true progression and pseudoprogression. Results: Multivariable stepwise logistic regression analysis showed that MGMT (O6-methylguanine-DNA methyltransferase) and EF max were independent differentiating variables (P = 0.004 and P = 0.02, respectively). ROC analysis yielded the best cutoff value of 95.75 for the EF max value for differentiating the two groups (sensitivity, 61%; specificity, 84.6%; AUC, 0.681 ± 0.08; 95% CI, 0.524-0.837; P = 0.03). In the leave-one-out cross-validation of the EF max value, the cross-validated values for predicting true progression and pseudoprogression accuracies were 69.4% and 71.4%, respectively. Conclusion: We demonstrated that contrast leakage information parameter from DSC MRI showed significance in differentiating true progression from pseudoprogression in glioblastoma patients.

The Study of Error for Analysis in Dynamic Image from the Error of Count Rates in NaI (Tl) Scintillation Camera (NaI (Tl) 신틸레이션 카메라에서 계수율 오차에 따른 동적 영상 분석치 산출 오류에 관한 연구)

  • Oh, Joo-Young;Kang, Chun-Goo;Kim, Jung-Yul;Park, Hoon-Hee;Oh, Ki-Baek;Kim, Jae-Sam
    • Journal of radiological science and technology
    • /
    • v.36 no.4
    • /
    • pp.291-297
    • /
    • 2013
  • This study is aimed to evaluate the effect of $T_{1/2}$ upon count rates in the analysis of dynamic scan using NaI (Tl) scintillation camera, and suggest a new quality control method with this effects. We producted a point source with $^{99m}TcO_4^-$ of 18.5 to 185 MBq in the 2 mL syringes, and acquired 30 frames of dynamic images with 10 to 60 seconds each using Infinia gamma camera (GE, USA). In the second experiment, 90 frames of dynamic images were acquired from 74 MBq point source by 5 gamma cameras (Infinia 2, Forte 2, Argus 1). There were not significant differences in average count rates of the sources with 18.5 to 92.5 MBq in the analysis of 10 to 60 seconds/frame with 10 seconds interval in the first experiment (p>0.05). But there were significantly low average count rates with the sources over 111 MBq activity at 60 seconds/frame (p<0.01). According to the second analysis results of linear regression by count rates of 5 gamma cameras those were acquired during 90 minutes, counting efficiency of fourth gamma camera was most low as 0.0064%, and gradient and coefficient of variation was high as 0.0042 and 0.229 each. We could not find abnormal fluctuation in $x^2$ test with count rates (p>0.02), and we could find the homogeneity of variance in Levene's F-test among the gamma cameras (p>0.05). At the correlation analysis, there was only correlation between counting efficiency and gradient as significant negative correlation (r=-0.90, p<0.05). Lastly, according to the results of calculation of $T_{1/2}$ error from change of gradient with -0.25% to +0.25%, if $T_{1/2}$ is relatively long, or gradient is high, the error increase relationally. When estimate the value of 4th camera which has highest gradient from the above mentioned result, we could not see $T_{1/2}$ error within 60 minutes at that value. In conclusion, it is necessary for the scintillation gamma camera in medical field to manage hard for the quality of radiation measurement. Especially, we found a tendency that count rate changes over time at this study, and we proved that it can effect $T_{1/2}$. And also, there is need of appropriate phantoms and the method of quality management like this study, because there are not any advice or limitation degrees for domestic medical purpose scintillation camera.

A Study on Dose Response of MAGAT (Methacrylic Acid, Gelatin Gel and THPC) Polymer Gel Dosimeter Using X-ray CT Scanner (X-ray CT Scanner를 이용한 MAGAT (Methacrylic Acid, Gelatin Gel and THPC) 중합체 겔 선량계의 선량 반응성 연구)

  • Jung, Jae-Yong;Lee, Choong-Il;Min, Jeong-Hwan;Kim, Yon-Lae;Lee, Seong-Yong;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.21 no.1
    • /
    • pp.1-8
    • /
    • 2010
  • In this study, we evaluated the dose response of MAGAT (Methacrylic Acid Gelatin gel and THPC) normoxic polymer gel dosimeters based on the X-ray CT scanner. To perform this study, we determined the proper ratio of the gel composition and acquired X-ray scan parameters. MAGAT gel dosimeters were manufactured using MAA (MethacrylicAcid) and gelatin of various concentration, irradiated up to 20 Gy. We obtained the 20 CT images from the irradiated gel dosimeters by using on a Phillips Brilliance Big Bore CT scanner with the various scan parameters. This CT images were used to determine the $N_{CT}$-dose response, dose sensitivity and dose resolution As an amount of MAA and gelatin were increase, the slope and intercept were increase in each MAGAT gel dosimeter with various concentration of the $N_{CT}$-dose response curve. The dose sensitivity was $0.38{\pm}0.08$ to $0.859{\pm}0.1$ and increased were amount of the MAA was increased or the gelatin was decreased. However, the change of gelatin concentration was very small compare to MAA. The Dose resolution ($D_{\Delta}^{95%}$) varies considerably from 2.6 to 6 Gy, dependent on dose resolution and CT image noise. The slope and dose sensitivity was almost ident verywith the variation of the tube voltage, tube current and slice thickness in the dose response curve, but the noise (standard deviation of averamalg CT number) was decreased when the tube voltage, tube current and slice thickness are increase. The optimal MAGAT polymer gel dosimeter based on the CT were evaluated to determine the CT imaging scan parameters of the maximum tube voltage, tube current and slice thickness (commonly used in clinical) using the composition ratio of a 9% MAA, 8% gelatin and 83% water. This study could get proper composition ratio and scan parameter evaluating dose response of MAGAT normoxic polymer gel dosimeter using CT scanner.

Palliative Effect of Radiation Therapy in Management of Symptomatic Osseous Metastases (골 전이암에서 고식적 방사선치료의 효과)

  • Shin, Sei-One;Kim, Sung-Kyu;Kim, Myung-Se
    • Journal of Yeungnam Medical Science
    • /
    • v.9 no.1
    • /
    • pp.102-109
    • /
    • 1992
  • Bone metastases represent an important and frequent clinical problem in patients with advanced cancers. Especially, painful bone metastases are common features in these patients. Radiotherapy is an effective tool for palliative aim of painful metastatic osseous lesions. Various treatment results have been previously reported. The present retrospective study was aimed to evaluate the efficacy of palliative irradiation on pain relief, with the goal of selecting appropriate irradiation dose schedule. Radiotherapy consisted of 5times a week with a various fractional dose between 180 and 400cGy. The response of pain relief and the survival time after completion of radiotherapy are related to total dose and most of the patients have shown a similar response by the end of radiotherapy. The higher dose and the more aggressive multimodality treatment, the better pain control and the longer survival time.

  • PDF

Impact of Adjuvant Chemoradiation Therapy on the Postoperative 5-year Survival Rates for Stage-II Gastric Cancer (2기 위암환자의 수술 후 보조 항암요법 및 방사선 치료가 생존율에 미치는 영향)

  • Hong, Seong-Kweon;Choi, Min-Gew;Baik, Yong-Hae;Noh, Jae-Hyung;Sohn, Tae-Sung;Kim, Sung
    • Journal of Gastric Cancer
    • /
    • v.5 no.4 s.20
    • /
    • pp.281-287
    • /
    • 2005
  • Purpose: This study was conducted to evaluate the effectiveness and the role of post-operative adjuvant chemoradiation therapy in a stage-II (UICC, 1997) primary gastric cancer. Materials and Methods: From September 1994 to December 2004, 954 stage-II gastric-cancer patients were seen, and all of them underwent a curative resection with extensive (D2) lymph-node dissection. The chemotherapy consisted of fluorouracil $(400mg/m^2)$ plus leucovorin $(20mg/m^2)$ for 5 days, followed by 4,500 cGy of radiotherapy for 5 weeks with fluorourcil and leucovorin on the first 4 days and the last 3 days of radiotherapy. Two five-day cycles of chemotherapy were given four weeks after the completion of radiotherapy. The Kaplan-Meier method was used to estimate the survival rates. To assess the importance of potential prognostic factors, we performed univariate and multivariate analyses using a log-rank test and Cox's proportional hazards regression model. A P value <0.05 was considered significant. Results: Univariate analysis revealed that age, tumor size, gross type, surgical method, and postoperative adjuvant therapy had statistical significance. Among these factors, age, surgical method, tumor size, surgical method, and postoperative adjuvant therapy were found to be independent prognostic factors by using a multivariate analysis. The postoperative adjuvant chemotherapy group and the chemoradiation therapy group had survival benefit compared to the surgery-only group. However the chemoradiation therapy group had no significant survival benefit compared to the chemotherapy group. Conclusion: The postoperative adjuvant therapy in stage-II gastric-cancer patients had significant benefit. Therefore, postoperative adjuvant chemoradiation therapy has an acceptable effect. A large-scale, randomized study is needed to evaluate the effectiveness and the role of postoperative radiation therapy.

  • PDF

Outcomes of Diffuse-Type Pigmented Villonodular Synovitis (PVNS) after Open Total Synovectomy (미만형 색소 융모 결절성 활액막염의 관혈적 활막 전 절제술 후 경과)

  • Lee, Mo-Ses;Lee, Soo-Hyun;Suh, Jin-Suck;Yang, Woo-Ik;Shin, Kyoo-Ho
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.16 no.1
    • /
    • pp.27-36
    • /
    • 2010
  • Purpose: Pigmented villonodular synovitis (PVNS) is a rare soft tissue tumor, which usually arises in larger joints, such as the knee. It has a high recurrence rate after surgical treatment. The purpose of this study is to evaluate and analyze the clinical results of diffuse-type pigmented villonodular synovitis cases that were treated with open total synovectomy. Materials and Methods: Between 1994 and 2006, 21 patients who had diffuse-type pigmented villonodular synovitis were selectively reviewed. Among the 21 cases studied, 14 patients presented at the knee, 5 at the ankle, and 2 at the shoulder and elbow. The mean follow up period was 5.5 years (range, 36-157 months). The average age of the patients was 34 years consist of 7 men and 14 women. Clinical outcomes were analyzed retrospectively, including range of motion and complications. Results: Open total synovectomy and adjuvant electrocautrization were done in all cases except one. During the regular follow-up period after the surgery, two patients showed symptoms of recurrence. After re-operation, only one case was pathologically confirmed as a recurrence. The patient who had partial synovectomy and the other patient who had second operation due to recur rence received additional radiation therapy. Clinical outcome scores were improved in every aspect (p<0.0001). 2 out of 14 Patients who had pigmented villonodular synovitis at the knee developed stiff knee after the surgery. Conclusion: After the open total synovectomy with electrocautrization, a low recurrence rate and satisfactory clinical outcome was achieved, observed in a minimum of 3 years of follow-up.