• Title/Summary/Keyword: Radiation intensity

Search Result 970, Processing Time 0.029 seconds

The Radiation Spot Size due to Wiggler Errors in a Free-Electron Laser Oscillator

  • Nam, Soon-Kwon;Park, Y.S.
    • Journal of the Korean Physical Society
    • /
    • v.73 no.10
    • /
    • pp.1495-1501
    • /
    • 2018
  • We have developed an extended three-dimensional free-electron laser (3D FEL) code with source-dependent expansion to calculate the intensity of the radiation field and the spot size in a free-electron laser oscillator. The effect of the wiggler field errors was evaluated for the case of a planar wiggler generated by a magnet stack with parabolic shaped pole faces by using the extended three-dimensional equations in a free-electron laser oscillator based on the proposed FEL facility which is to be operated in the far-infrared and the infrared regions. The radiation spot size due to the wiggler field errors also have been analyzed for wiggler errors of ${\Delta}B/B=0.0$, 0.03, 0.06 and 0.09% at z = 1 m and z = 2 m. The effect of the diffraction of radiation field due to the wiggler field errors of ${\Delta}B/B=0.0$ and ${\Delta}B/B=0.09%$ at 200 passes was evaluated by using the extended 3D code that we developed. The variation of the curvature of the phase front and the effect of the radiation field intensity due to the wiggler field errors were also evaluated for B = 0.5 T and B = 0.7 T with the wiggler error of ${\Delta}B/B=0.09%$ at 200 passes and the results were compared to those of without errors. The intensity of the radiation, behavior of the radiation spot size and the variation of the curvature of the phase were highly sensitive to the wiggler error of ${\Delta}B/B$ > 0.09%, but were less sensitive to the wiggler errors for ${\Delta}B/B$ < 0.09% in a free-electron laser (FEL) oscillator based on the proposed FEL facility.

Dosimetric Comparison between Intensity Modulated Radiotherapy and 3 Dimensional Conformal Radiotherapy in the Treatment of Rectal Cancer

  • Simson, David K;Mitra, Swarupa;Ahlawat, Parveen;Sharma, Manoj Kumar;Yadav, Girigesh;Mishra, Manindra Bhushan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.11
    • /
    • pp.4935-4937
    • /
    • 2016
  • Objective: To compare dosimetric parameters of 3 dimensional conformal radiotherapy (3 DCRT) and intensity modulated radiotherapy (IMRT) in terms of target coverage and doses to organs at risk (OAR) in the management of rectal carcinoma. Methods: In this prospective study, conducted between August 2014 and March 2016, all patients underwent CT simulation along with a bladder protocol and target contouring according to the Radiation Therapy Oncology Group (RTOG) guidelines. Two plans were made for each patient (3 DCRT and IMRT) for comparison of target coverage and OAR. Result: A total of 43 patients were recruited into this study. While there were no significant differences in mean Planning Target Volume (PTV) D95% and mean PTV D98% between 3 DCRT and IMRT, mean PTV D2% and mean PTV D50% were significantly higher in 3 DCRT plans. Compared to IMRT, 3 DCRT resulted in significantly higher volumes of hot spots, lower volumes of cold spots, and higher doses to the entire OAR. Conclusion: This study demonstrated that IMRT achieves superior normal tissue avoidance (bladder and bowel) compared to 3 DCRT, with comparable target dose coverage.

A Study on the Incidence of Side Effects according to the Number of Beams in Intensity-modulated Radiation Therapy for Prostate Cancer using 15 MV (15 MV를 이용한 전립샘암 세기조절 방사선치료 시 빔의 개수에 따른 부작용 발생률에 관한 연구)

  • Joo-Ah Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.481-487
    • /
    • 2023
  • In this study, we analyzed the incidence of side effects of photoneutron dose according to the number of beams during intensity-modulated radiotherapy of prostate cancer using 15 MV. The radiation treatment plan design for intensity-modulated radiation therapy for prostate cancer was established with a prescription dose of 220 cGy per dose and a total of 7260 cGy for 33 treatments. The linear accelerator used in the experiment is Varian's True Beam STx (Varian, USA). Photoneutron dose was generated by using 15 MV energy in the planning target volume (PTV). The treatment plan was designed with IMRT 5, 7, and 9 portals using the Eclipse System (Varian Ver 10.0, USA). An optically stimulated luminescence albedo neutron dosimeter (Landauer Inc., USA) was used to measure photoneutron dose. IMRT 5 portals, 1.7 per 1,000, 7 portals, 1.8 per 1,000, 9 portals, 2.0 per 1,000 were calculated as the probability of experiencing side effects on the thyroid gland due to photoneutron dose. This study studies the risk of secondary radiation exposure dose that can occur during intensity-modulated radiation therapy, and it is considered that it will be used as useful data in relation to stochastic effects in the future.

Effect of Crosslinking on the PTC Stability Carbon Black Filled HDPE/EEA Copolymer Composite (카본블랙 충전 HDPE/EEA Copolymer 복합재료에 있어서 가교구조가 PTC 특성에 미치는 영향)

  • Lee, Gun-Joo
    • Proceedings of the KIEE Conference
    • /
    • 2001.11a
    • /
    • pp.140-145
    • /
    • 2001
  • In order to apply for silane crosslinking process to PTC products, especially. self-regulating heater, silane crosslinked samples were compared with radiation crosslinked sample in terms of PTC characteristic and PTC stability. Silane crosslinked samples have lower PTC intensity than radiation crosslinked sample. It can be explained that multiple networks of silane crosslink restrict the movement of molecules in the composite as the sample is heating. As a result of heat cycles at $140^{\circ}C$, the changes of volume resistivity and PTC intensity for radiation crosslinked sample were higher than those of silane crosslinked samples. Whereas, in the case of heat cycles at $85^{\circ}C$, which is limiting temperature for self-regulating heater, both silane and radiation crosslinked samples show stable results without pronounce changes of resistivity up to five cycles.

  • PDF

Effect of the Pin Radius on the Radiation Characteristics of a Patch Antenna with a Pin Array on a Patch (핀 반경이 패치에 핀 배열을 가지는 안테나의 방사 특성에 미치는 영향)

  • Lee, Woo-Ram;Kim, Tae-Young;Kim, Boo-Gyoun;Shin, Jong-Dug
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.355-356
    • /
    • 2008
  • Effect of the pin radius on the radiation characteristics of a patch antenna with a pin array inserted between a patch and ground plane is investigated. As the pin radius increases, the resonant frequency increases and the radiation intensity in the horizontal plane decreases. However, the radiation intensity in the horizontal plane increases for the pin radius larger than a certain value.

  • PDF

The Effects of W-B Radiation on Photosynthetic Electron Transport of Baney (Hondeum vulgare L) Leaves (UV-B가 보리(Hordeum vulgare L.)잎의 광합성 전자전달에 미치는 영향)

  • 박강은;정화숙
    • Journal of Environmental Science International
    • /
    • v.6 no.4
    • /
    • pp.369-378
    • /
    • 1997
  • The effects of various intensity of W-B on barley seeding were investigated by PS I and II activities and chlorophyll fluorescence. The Inhibitory effect of UV-B radiation on electron transport activity was Increased as the intensity of UV-B Irradiation was increased. Especially, PS I is more sensitive to UV-B radiation than PS I is. By the addition of uncle electron donor, DPC, to the chloroplasts of the barley seedlings treated with UV-B, the photoreduction of DCPIP was recovered by only 1 IBI on electron transport activity. However, the activity of PS II was Inhibited by 45% by the treatment with UV-B, but recovered it only 11% by the addition of DPC. These suggest that other sites besides the oxidation site of PS II may be affected more by UV-B Irradiation. As the intensify of UV-B was Increased, Fo was Increased while Fv was decreased, and thus Fv/Fm was decreased. This means that photochemical efficiency was reduced. With this parameters, it might be that UV-B radiation affected adversely to around PS II.

  • PDF

Whole pelvic intensity-modulated radiotherapy for high-risk prostate cancer: a preliminary report

  • Joo, Ji Hyeon;Kim, Yeon Joo;Kim, Young Seok;Choi, Eun Kyung;Kim, Jong Hoon;Lee, Sang-Wook;Song, Si Yeol;Yoon, Sang Min;Kim, Su Ssan;Park, Jin-Hong;Jeong, Yuri;Ahn, Hanjong;Kim, Choung-Soo;Lee, Jae-Lyun;Ahn, Seung Do
    • Radiation Oncology Journal
    • /
    • v.31 no.4
    • /
    • pp.199-205
    • /
    • 2013
  • Purpose: To assess the clinical efficacy and toxicity of whole pelvic intensity-modulated radiotherapy (WP-IMRT) for high-risk prostate cancer. Materials and Methods: Patients with high-risk prostate cancer treated between 2008 and 2013 were reviewed. The study included patients who had undergone WP-IMRT with image guidance using electronic portal imaging devices and/or cone-beam computed tomography. The endorectal balloon was used in 93% of patients. Patients received either 46 Gy to the whole pelvis plus a boost of up to 76 Gy to the prostate in 2 Gy daily fractions, or 44 Gy to the whole pelvis plus a boost of up to 72.6 Gy to the prostate in 2.2 Gy fractions. Results: The study cohort included 70 patients, of whom 55 (78%) had a Gleason score of 8 to 10 and 50 (71%) had a prostate-specific antigen level > 20 ng/mL. The androgen deprivation therapy was combined in 62 patients. The biochemical failure-free survival rate was 86.7% at 2 years. Acute any grade gastrointestinal (GI) and genitourinary (GU) toxicity rates were 47% and 73%, respectively. The actuarial rate of late grade 2 or worse toxicity at 2 years was 12.9% for GI, and 5.7% for GU with no late grade 4 toxicity. Conclusion: WP-IMRT was well tolerated with no severe acute or late toxicities, resulting in at least similar biochemical control to that of the historic control group with a small field. The long-term efficacy and toxicity will be assessed in the future, and a prospective randomized trial is needed to verify these findings.

Gross tumor volume dependency on phase sorting methods of four-dimensional computed tomography images for lung cancer

  • Lee, Soo Yong;Lim, Sangwook;Ma, Sun Young;Yu, Jesang
    • Radiation Oncology Journal
    • /
    • v.35 no.3
    • /
    • pp.274-280
    • /
    • 2017
  • Purpose: To see the gross tumor volume (GTV) dependency according to the phase selection and reconstruction methods, we measured and analyzed the changes of tumor volume and motion at each phase in 20 cases with lung cancer patients who underwent image-guided radiotherapy. Materials and Methods: We retrospectively analyzed four-dimensional computed tomography (4D-CT) images in 20 cases of 19 patients who underwent image-guided radiotherapy. The 4D-CT images were reconstructed by the maximum intensity projection (MIP) and the minimum intensity projection (Min-IP) method after sorting phase as 40%-60%, 30%-70%, and 0%-90%. We analyzed the relationship between the range of motion and the change of GTV according to the reconstruction method. Results: The motion ranges of GTVs are statistically significant only for the tumor motion in craniocaudal direction. The discrepancies of GTV volume and motion between MIP and Min-IP increased rapidly as the wider ranges of duty cycles are selected. Conclusion: As narrow as possible duty cycle such as 40%-60% and MIP reconstruction was suitable for lung cancer if the respiration was stable. Selecting the reconstruction methods and duty cycle is important for small size and for large motion range tumors.

Monte Carlo Simulation of Small Photon Beam Measurements by Beam Intensity Scanner System(BISS)

  • Park, Kwangyl;Vahc, Young-Woo;Ohyun Kwon;Park, Kyung-Ran;Lee, Yong-Ha;Yi, Byung-Yong;Kim, Sookil
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.282-284
    • /
    • 2002
  • We have developed and used BISS as a radiation detector to verify patient dose and determine the physical characteristics of beams used in Stereotatic Radio Surgery(SRS) and Intensity Modulated Radiation Therapy(IMRT). In order to confirm the function and accuracy of our BISS, we simulate our measurements by BISS under the radiation of 6MV photons from a Varian Clinac 21EX equipped with a 60 leaf pairs MLC. For the simulation based on the Monte Carlo algorithm, which remains the most comprehensive and accurate theoretical method to verify beam profiles, we use the BEAM code. Compared with the measurements by BISS, our simulation of variously shaped phantom measurements show good agreements. Our simulation results can be used as a theoretical standard to compare and confirm measurements by BISS and other dosimeters such as ultramicro cylindrical ionization chamber(UCIC) and radiographic film.

  • PDF