희토류계(稀土類系) 증감지(增感紙)에 관(關)한 연구(硏究) (Study on the Rare-earth Phosphors Intensifying Screen)

  • 허준;김창균
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제1권1호
    • /
    • pp.15-24
    • /
    • 1978
  • The characteristics of the rare earth phosphors intensifying screen (LM-6, Grenex-8) as compared with $CaWO_4$ intensifying screen had been studied utilizing several common x-ray films, and found the following results. 1. Compared with the conventional CaWO4 intensifying screen, the rare earth phosphors intensifying screen was found to be more sensitive over to 1.26-3.47 times. So the radiation exposure could be reduced to 1/1.26 -1/3.47. 2. Sharpness as well as the film speed were both increased. So the motion blurring and geometrical unsharpness could be decreased. 3. In spite of that the film speed was increased, photographic contrast was kept up. Therefore, the more ideal film of greater latitude could be obtained. 4. The effects of the rare earth phosphors intensifying screen would be much increased as using with orthochromatic x-ray films.

  • PDF

증감지를 이용한 방사선검출기 개발 (Development of Radiation Detector with Intensifying Screen)

  • 서정민
    • 한국방사선학회논문지
    • /
    • 제17권6호
    • /
    • pp.859-863
    • /
    • 2023
  • 본 연구에서는 엑스선 증감지와 광센서, 마이크로컨트롤러(MCU)를 이용하여 휴대와 이동이 용이한 교육용 방사선검출기를 제안하였다. 광센서와 증감지로 이루어진 검출부와 마이크로컨트롤부로 간단하게 구성되어 제작이 쉽고 소형화 및 휴대형으로 적합하게 제작되었다. 검출기의 성능 확인을 위해 전압을 50에서 100 kVp까지 변경하며 검출시스템과 흡수선량계를 이용하여 방사선을 측정하였다. 관전류량은 100 mAs, SDD는 100 cm로 고정하였고 각 관전압에서 10회 반복 측정하였다. 측정값을 이용하여 검출기의 응답과 선형성을 확인하였다. 검출기와 흡수선량계의 측정결과 비교에서 높은 상관성(r:0.998, p<.001)을 보임을 확인하였다. 이러한 결과를 통하여 본 연구에서 제안된 증감지와 마이크로컨트롤러 기반의 검출기의 사용가능성을 확인할 수 있었으며, 휴대형 방사선검출시스템이 소형, 저가형, 휴대형 시스템으로 교육용으로 적용이 가능할 것으로 판단되었다.

흉부(胸部) X선촬영시(線撮影時) 부가여과사용(附加濾過使用)에 따른 선양(線量)과 선질(線質)에 관(關)한 연구(硏究) (A Study of Radiation Dose and Quality by Using Added Filtration in Chest Radiography)

  • 유병헌;추성실;허준
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제10권1호
    • /
    • pp.13-23
    • /
    • 1987
  • Author has studied for finding the method of decreasing the radiation dose and increasing diagnostic range in chest X-ray radiography. The study for the added filter thickness from half value layer to 1/8 value layer by decreasing curve and research for the exposure factors, decreasing ratio of radiation dose, ratio of scatter ray and image quality in chest X-ray radiography. The results were as follows: 1. By using the rare earth intensifying screen system at 120 Kvp, the sensitivity is increased by times and the exposure ratio is decreased 0.22 by comparison with the $CaWO_{4}$ intensifying screen system at 80 Kvp. 2. By using Al added filter of 1/8 value layer, the scatter ray is increased more than no filter, But the scatter ray is decreased more in $G_{4}/RxOG$ intensifying system than in LT-II/Rx intensifying system. 3. At 120 Kvp, the image quality value of $G_{4}/RxOG$ system is increased more than LT-II/Rx system compared with slight decreasing image quality value at 80 Kvp. Concluded that by using the added filter could decrease the radiation dose by 1/3 and obtain effective image quality with the added filter at high voltage hard exposure.

  • PDF

유연한 Gd2O2S:Tb 증감지 제작 및 피로누적에 대한 영향 (Fabrication of Bendable Gd2O2S:Tb Intensifying Screen and Evaluation of Fatigue Properties)

  • 박지군;양승우;전제훈;김주희;허예지;강상식;김교태
    • 한국방사선학회논문지
    • /
    • 제11권7호
    • /
    • pp.611-617
    • /
    • 2017
  • 본 연구에서는 연성을 형광체 층이 가질 수 있다면 외부의 기계적 외력에 대하여 장기간 안정성을 확보할 수 있을 것으로 기대하였다. 이에 본 연구에서는 스크린 프린팅 공법을 통하여 유연한 $Gd_2O_2S:Tb$ 증감지를 제작하였고 장기적인 외력에 의한 피로누적과 반복적인 외력에 의한 피로누적에 따른 영향을 고찰하고자 RMS 분석과 히스토그램을 분석을 통하여 영상 균일도를 평가하였다. 연구 결과, 지속적인 외력에 대하여는 지배적인 픽셀 영역이 일정하게 유지되면서 RSD가 10% 이내를 만족하였으나, 반복적인 외력의 경우 지배적인 픽셀 영역이 3 영역으로 분할되며 영상 균일도에 악영향을 미치며 RSD가 10% 이상으로 증가하는 것으로 나타났다. 이러한 결과를 바탕으로 기존 방사선증감지에 대비하여 기계적 안정성을 확보함으로써 곡면 검출기의 적용 가능성을 제시하였으나 아직까지 플렉시블 검출기에 적용하기 위해서는 추가적인 연구가 필요할 것으로 사료된다. 이러한 결과 유연성을 가진 방사선 증감지는 다양한 곡면에 적용이 가능하므로 향후 핵의학, 치료용, 산업 분야 등과 같은 다양한 분야에 적용할 수 있을 것으로 기대된다.