Design and performance prediction of large-area hybrid gamma imaging system (LAHGIS) for localization of low-level radioactive material

  • Lee, Hyun Su;Kim, Jae Hyeon;Lee, Junyoung;Kim, Chan Hyeong
    • Nuclear Engineering and Technology
    • /
    • 제53권4호
    • /
    • pp.1259-1265
    • /
    • 2021
  • In the present study, a large-area hybrid gamma imaging system was designed by adopting coded aperture imaging on the basis of a large-area Compton camera to achieve high imaging performance throughout a broad energy range (100-2000 keV). The system consisting of a tungsten coded aperture mask and monolithic NaI(Tl) scintillation detectors was designed through a series of Geant4 Monte Carlo radiation transport simulations, in consideration of both imaging sensitivity and imaging resolution. Then, the performance of the system was predicted by Geant4 Monte Carlo simulations for point sources under various conditions. Our simulation results show that the system provides very high imaging sensitivity (i.e., low values for minimum detectable activity, MDA), thus allowing for imaging of low-activity sources at distances impossible with coded aperture imaging or Compton imaging alone. In addition, the imaging resolution of the system was found to be high (i.e., around 6°) over the broad energy range of 59.5-1330 keV.

진단용 엑스선 장치에 있어서 방사선 방어에 대한 일반 요구사항 -IEC 60601-1-3:2008에 근거한 KFDA DRS 1-1-3:2008- (General Requirements Pertaining to Radiation Protection in Diagnostic X-ray Equipment -KFDA DRS 1-1-3 : 2008 base on IEC 60601-1-3:2008-)

  • 강희두;동경래;권대철;최준구;정재호;정재은;류영환
    • 대한디지털의료영상학회논문지
    • /
    • 제11권2호
    • /
    • pp.69-77
    • /
    • 2009
  • This study gives an account of the collateral standards in IEC 60601-1-3: 2008 specifying the general requirements for basic safety and essential performance of diagnostic X-ray equipment regarding radiation protection as it pertains to the production of X-rays. The collateral standards establish general requirements for safety regarding ionization radiation in diagnostic radiation systems and describe a verifiable evaluation method of suitable requirements regarding control over the lowest possible dose equivalent for patients, radiologic technologists, and others. The particular standards for each equipment can be determined by the general requirements in the collateral standard and the particular standard is followed in the risk management file. The guidelines for radiation safety of diagnostic radiation systems is written up in ISO 13485, ISO 14971, IEC 60601-1-3(2002)1st edition, medical electric equipment part 1-3, and the general requirements for safety-collateral standards: programmable electrical medical systems. Therefore the diagnostic radiation system protects citizens' health rights with the establishment and revisions of laws and standards for diagnostic radiation systems as a background for the general requirements of radiation safe guards applies, as an international trend, standards regarding the medical radiation safety management. The diagnostic radiation system will also assure competitive power through a conforming evaluation unifying the differing standards, technical specifications, and recognized processes.

  • PDF

구내 촬영용 엑스선 장치의 관전류에 따른 영상 평가 (Image Evaluation according to Tube Current of X-ray Device for Intraoral Imaging)

  • 김아연;조병두;이승재
    • 한국방사선학회논문지
    • /
    • 제17권4호
    • /
    • pp.515-521
    • /
    • 2023
  • 치과 구내 촬영 시 사용하는 관전류 및 시간에 따라 환자가 받는 피폭선량은 달라진다. 영상의 질을 위해서는 많은 양의 관전류가 필요하지만, 환자에게 부여되는 방사선량은 그만큼 높아진다. 이에 본 연구에서는 시뮬레이션을 통한 치과 구내 촬영 시 사용하는 관전류에 따른 영상의 질 평가를 통해 영상의 질을 확보하면서 환자가 받는 피폭선량은 감소시킬 수 있는 최적의 관전류 양을 산출하였다. 치과 구내 촬영의 진단참고수준 가이드라인에 제시된 평균 관전류와 시간 및 관전압을 기본 촬영 조건으로 사용하고, 관전류만 변화시켰을 때 영상을 획득한 후 기본 영상과의 영상의 질 비교·분석을 통해 최적의 관전류 양을 산출하였다. 기본 조건은 63 kV, 6 mA, 0.29 s로 하고 관전류를 0.1, 0.5, 1, 2, 3, 4, 5 mA로 변경시켜 영상을 획득하였다. 획득한 영상은 ICY 프로그램을 사용하여 6 mA의 조건으로 촬영한 영상과 구조적 유사지수를 평가하였다. 그 결과 0.5 mA의 관전류 조건에서도 6 mA의 영상과 구조적 유사지수가 높은 것으로 평가되었다. 이러한 결과를 바탕으로 치과 구내 촬영 시 6 mA가 아닌 0.5 mA로 촬영한다면 환자에게 부여되는 피폭선량을 매우 감소시킬 수 있을 것으로 판단된다.

Verification of Microstructure Qualities of ACR-Approved Mammography Phantoms by Refraction-Enhanced Synchrotron Radiation Imaging

  • Imamura, Keiko;Ehara, Norishige;Inada, Yoichi;Miyamoto, Keiko;Kanemaki, Yoshihide;Umetani, Keiji;Uesugi, Kentaro;Ochiai, Yoshinori;Fukuda, Mamoru;Nakajima, Yasuo
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.415-417
    • /
    • 2002
  • Images of microcalcification specks showed large variation in conventional radiographs of phantoms which are approved for mammography image quality standard by the American College of Radiology (ACR). This kind of variation is not appropriate for image quality standards because the number of specks are visually counted in images and that number is important in image quality evaluation. Our study using synchrotron radiation (SR) imaging revealed the overlapping of micro-sized air bubble(s) to some specks, and also the structural deformation or crackings. Eight phantoms approved by ACR from two different makers and an air-bubble phantom were examined. SR imaging was performed at a synchrotron radiation facility, SPring-8, in Japan. The image-detector was a fluorescent-screen optical-lens coupling system using a CCD camera with a spatial resolution of 6 $\square$m. Objects when imaged with longer sample-to-detector distance show edge enhancement due to a difference in refraction indices, that is refraction enhancement. Refraction-enhanced SR images revealed that some of specks carried foreign objects, which were proven to be air. In phantoms provided by one maker, attaching/overlapping airs were observed for 62 out of 150 specks (41%) , with a higher incidence for the smallest specks. A speck becomes hardly visible in a conventional radiograph when air(s) overlaps the majority part of a speck, though depending on the size of the air-inclusion and on its configuration. Those airs might have been adsorbed on a speck surface before being embedded and then introduced into the matrix together with specks. Our study using SR imaging has clearly shown the nature of defects in some mammography phantoms which seriously degrade the quality as an image standard.

  • PDF

Numerical Modeling and Experiment for Single Grid-Based Phase-Contrast X-Ray Imaging

  • Lim, Hyunwoo;Lee, Hunwoo;Cho, Hyosung;Seo, Changwoo;Lee, Sooyeul;Chae, Byunggyu
    • 한국의학물리학회지:의학물리
    • /
    • 제28권3호
    • /
    • pp.83-91
    • /
    • 2017
  • In this work, we investigated the recently proposed phase-contrast x-ray imaging (PCXI) technique, the so-called single grid-based PCXI, which has great simplicity and minimal requirements on the setup alignment. It allows for imaging of smaller features and variations in the examined sample than conventional attenuation-based x-ray imaging with lower x-ray dose. We performed a systematic simulation using a simulation platform developed by us to investigate the image characteristics. We also performed a preliminary PCXI experiment using an established a table-top setup to demonstrate the performance of the simulation platform. The system consists of an x-ray tube ($50kV_p$, 5 mAs), a focused-linear grid (200-lines/inch), and a flat-panel detector ($48-{\mu}m$ pixel size). According to our results, the simulated contrast of phase images was much enhanced, compared to that of the absorption images. The scattering length scale estimated for a given simulation condition was about 117 nm. It was very similar, at least qualitatively, to the experimental contrast, which demonstrates the performance of the simulation platform. We also found that the level of the phase gradient of oriented structures strongly depended on the orientation of the structure relative to that of linear grids.

열형광체를 이용한 X선 영상판의 제작 (Preparation of the X-Ray Imaging Plate Using Thermoluminescent Phosphor)

  • 이원진;이동명
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제14권1호
    • /
    • pp.49-60
    • /
    • 1991
  • Thermoluminescent phosphors, which are now being used widely in radiation dosimetry, have an excellent sensitivity to ionizing radiation. In this study, thermoluminescent phosphors of $CaSO_4$ : Mn, $CaSO_4$ : Dy and $CaSO_4$ : Tm are prepared and their physical properties are investigated by measuring the trapping parameters and their luminescent spectra. By considering the sensitivity to X-ray and fading characteristics, $CaSO_4$ : Dy is most adequate to imaging plate. The imaging plate are prepared by coating the $CaSO_4$ : Dy powder on the Al substrate and its dose dependence is linear within the range of 40 mGy-20 Gy X-ray. The sensitivity of imaging plate depends linearly on the thickness of coated phosphor layer up to $35\;mg/cm^2$ and is independent on the grain size of the phosphor in the range of $70{\sim}250\;{\mu}m$. By photographing the imaging plate, X-ray images of the test object are obtained and better than those of X-ray films.

  • PDF

SPATIO-SPECTRAL MAXIMUM ENTROPY METHOD: II. SOLAR MICROWAVE IMAGING SPECTROSCOPY

  • Bong, Su-Chan;Lee, Jeong-Woo;Gary Dale E.;Yun Hong-Sik;Chae Jong-Chul
    • 천문학회지
    • /
    • 제38권4호
    • /
    • pp.445-462
    • /
    • 2005
  • In a companion paper, we have presented so-called Spatio-Spectral Maximum Entropy Method (SSMEM) particularly designed for Fourier-Transform imaging over a wide spectral range. The SSMEM allows simultaneous acquisition of both spectral and spatial information and we consider it most suitable for imaging spectroscopy of solar microwave emission. In this paper, we run the SSMEM for a realistic model of solar microwave radiation and a model array resembling the Owens Valley Solar Array in order to identify and resolve possible issues in the application of the SSMEM to solar microwave imaging spectroscopy. We mainly concern ourselves with issues as to how the frequency dependent noise in the data and frequency-dependent variations of source size and background flux will affect the result of imaging spectroscopy under the SSMEM. We also test the capability of the SSMEM against other conventional techniques, CLEAN and MEM.

The Study of Opportunistic Infection in the Medical Radiation Environment

  • Kim, Hyun-Soo;Dong, Kyung-Rae;Park, Ho-Sung
    • 대한디지털의료영상학회논문지
    • /
    • 제13권3호
    • /
    • pp.105-109
    • /
    • 2011
  • With the development of medical technologies and the growth of household incomes, most of the people have become to be interested in health as it leads to significant early detection and cure of diseases. However the pattern of disease becomes diverse and it makes the imaging diagnosis department crowded with many patients. Therefore the opportunistic infection could be serious there. The hospital becomes the place which provides high risks of infection danger but it is true that the opportunistic infection of the hospital employees is not still recognized well. The imaging diagnosis department has developed a lot but it becomes the medium of secondary infection of patients and employees. So this study analyzesthe status of bacteria infection of the examination table, the handle of diagnostic equipment and the hands of radiation staffs in imaging diagnosis department of the general hospitals and individual ones. And the result shows that some bacteria were found even though it's little. We are trying to make the hospitals to be free of secondary infection securing safety measure to prevent the secondaryinfection from occurring to patients and hospital employees.