• 제목/요약/키워드: Radiation heat loss

검색결과 163건 처리시간 0.025초

내측 블라인드의 하절기 일사열 차폐 성능 비교 (Comparing Solar Heat Shading Performances of Internal Blinds in the Summer)

  • 박은미;최동호;박민용;이경희
    • 한국태양에너지학회 논문집
    • /
    • 제34권6호
    • /
    • pp.75-83
    • /
    • 2014
  • Heat loss through windows and doors occupies 20 to 45% of the total heat loss in building. It accounts for a large proportion of the total heat loss in building. In order to suppress the amount of heat flow through the windows and doors were considered actions such as reinforcement of insulation performance of window, adoption of low-e glass, and installation of solar heat shading device. The Purpose of this study is to compare solar heat shading performances of 3 types of internal blinds in the summer. In order to verify the solar heat shading performances of the blinds, a roll blind, blind A(Venetian blind) and blind B(Daylight guiding venetian blind)were installed in the four rooms with the same environmental conditions. As a result of the experiment, the blind B, blind A, roll blind showed an excellent performance in that order. Its because the blind B is made of aluminum materials coated with special paints on surface. It doesn't converted to long wave by short wave light. and it is reflected to short wave to outside.

東海熱收支 의 時.空間的인 分布 (Temporal and spatial distributions of heat fluxes in the East Sea(Sea of Japan))

  • 박원선;오임상
    • 한국해양학회지
    • /
    • 제30권2호
    • /
    • pp.91-115
    • /
    • 1995
  • 동해에서의 해양-대기 열교환량을 1961년부터 1990년까지의 선상관측자료와 1976 년부터 1985년까지의 일본기상처 부표자료를 이용하여 구하였다. 그리고 이 결과와 해 양상층부 200m 내의 열용량의 계절변화로부터 해양내부의 열유동량을 계산하였다. 겨 울에는 유입되는 단과복사량과 방출되는 장파오복사량의 크기가 비슷해 복사에 의한 열방출량은 적지만 열속과 자멸속이 강하여 전 해역에서 대기로 많은 열량을 방출한 다. 유효열방출량의 공간적인 변화폭은 100 Wm/SUP -2/이상이며, 최대의 열방출량은 쓰가루해협 부근에서 일어나고 대한해협과 울릉분지역등 남부역이 높은 방출량이 나타 난다. 특히 남서 해역의 강한 열방출이 겨울에 동해 중층균실수의 형성에 영향을 주는 것으로 보인다. 여름에는 강한 태양복사와 낮은 난류속의 영향으로 전해역에서 120~ 140 Wm/SUP -2/의 비슷한 크기로 해양이 가열된다. 해양내부의 열유동은 일본연안에서 양의 값을 나타내 여름의 강한 대마난류에 의한 열량의 유입을 보이며, 그 크기는 해 면을 통해 흡수한 열량보다 커서 여름에는 대마난류에 의한 열유입이 중요함을 보여준 다. 한국연안에서는 음의 값으로 수온이 낮은 북한 한류계수의 남하를 나타낸다. 봄과 가을은 3월과 100월에 각각 최소, 최대를 나타낸다. 유효열교환량의 연변화폭은 남서 해역의 경우 약 580 Wm/SUP -2/이다. 해표면을 통한 연평균 유효열교환량은 모든 해역 에서 음의 값으로 대기중으로 열량을 방출하며, 그 크기는 쓰가루해협부근에서 -130 Wm/SUP -2/로 강하고 대한해협과 울릉분지역에서도 이웃하는 해역보다 많은 열량을 방 출한다. 위도 35$^{\circ}$~39$^{\circ}$N 사이에서의 공간적인 연평균값의 크기는 단파복사량, 자멸 속, 장파복사, 열속의 크기로 각각 129, -90, -58, -32Wm/SUP -2/으로 유효열교환량은 -51W/SUP -2이다.

  • PDF

방사소음 및 투과소음에 대한 승용차량 대시패널의 설계인자별 영향도분석 (Evaluation of design variables to improve noise radiation and insulation performances of a dash panel component of an automotive vehicle)

  • 유지우;채기상;박철민;서진관;이기용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2011년도 춘계학술대회 논문집
    • /
    • pp.526-531
    • /
    • 2011
  • A dash panel component, close to passengers, plays a very important role to protect heat and noise from a power train. Meanwhile, it is also a main path that transfers vibration energy and eventually radiates acoustic noise into the cavity. Therefore, it seems important to provide an optimal design scheme incorporating sound packages such as dash isolation pad and carpet, as well as structures. The present study is the extension of the previous investigation how design variables affect sound radiation, which was carried out using the simple plate and framed system. The system taken into account in this paper is a dash panel component of a sedan, which includes A pillar, front side member, dash panel and the corresponding sound packages. Design variables such as panel thickness and sound package layers are investigated how they are related for the better radiation performance (i.e. structure-borne) and sound transmission loss (i.e. air borne).

  • PDF

층류확산화염의 불안정성에 대한 매연생성 특성의 역할 (Soot Formation Characteristics on the Instability of Laminar Diffusion Flames)

  • 남연우;이원남
    • 한국연소학회지
    • /
    • 제15권3호
    • /
    • pp.74-81
    • /
    • 2010
  • In this study, soot formation characteristics on the instability of laminar diffusion flames were investigated experimentally using a concentric co-flow burner. When a small amount of air was supplied through an inner nozzle, a stable propane laminar diffusion flame became unstable and began to oscillate mainly due to the dilution effect. The increase of air flow rate transformed an oscillating non-sooting flame into a stable nonsooting flame. When the air flow rate was continuously increased an inner flame was formed and the flame was changed to an oscillating sooting flame, an oscillating non-sooting flame and finally a stable non-sooting hollow flame. When the air flow rate was decreased, a non-sooting hollow flame was eventually changed back to a stable non-sooting flame. The presence of an inner flame, however, altered the soot formation characteristics of a flame. More soot production was observed with the presence of an inner flame. The increased or decreased soot formation/oxidation rates, the radiation heat loss, and the heating effect of inner flames are most likely to be responsible for the observed instability of laminar diffusion flames.

동적 단열재를 적용한 건물에서의 에너지소비량 비교 분석 (Heating Power Consumption Comparison Study Between Static Insulation and Dynamic Insulation at KIER Twin Test Cell)

  • 강은철;박용대;이의준;윤태권
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.919-924
    • /
    • 2008
  • Power consumption in the building thermal load could be the sum of the building fabric conduction load, building ventilation convection load and other such as radiation loss load. Dynamic Breathing Building (DBB) is the state-of-the-art to improve the wall insulation and indoor air quality(IAQ) performance as making air flow through the wall. This heat recovery type DBB contributes the power consumption saving due to the improved dynamic U-value. KIER twin test cell with static insulation(SI) and dynamic insulation(DI) at KIER was developed to test building power consumption at the real outside conditions. Then, the actual results were compared with the theory to predict the power consumption at the KIER twin test cell and introduced the building new radiation loss factor $\alpha$ to explain the difference between the both the theory and the actual case. As the results, the power consumption at the breathing DI wall building could saved 10.8% at the 2ACH(Air change per hour) compared with conventional insulation. The building radiation loss factor $\alpha$ for this test condition to calibrate the actual test was 0.55 in the test condition.

  • PDF

고온연료의 점화 및 화염 소화특성에 미치는 복사효과 (Radiation Effects on the Ignition and Flame Extinction of High-temperature Fuel)

  • 김유정;오창보;최병일;한용식
    • 한국화재소방학회논문지
    • /
    • 제27권6호
    • /
    • pp.50-56
    • /
    • 2013
  • 대향류 비예혼합 연료-공기 유동장에서 고온연료의 점화특성과 형성된 화염의 소화특성에 미치는 복사효과에 대해 수치계산을 통해 검토하였다. 화학반응의 계산을 위해 GRI-v3.0의 상세화학반응기구를 사용하였으며, 단열계산과 광학적으로 얇은 복사모델을 적용하여 계산을 수행하였다. 대향류 유동장의 점화와 소화점을 정확히 찾기 위하여 화염제어 연속계산법을 적용하였다. 결과를 통해 스트레인율 변화에 대해 최고 온도보다는 최고 H 라디칼 농도가 점화와 소화거동을 이해하는데 더 적합하다는 것을 확인하였다. 최고 H 라디칼 농도변화 거동을 통해 기존에 알려진 S-곡선, C-곡선 및 O-곡선 등을 확인하였다. 복사열손실 분율($f_r$)과 공간에 대해 적분된 열발생률(IHRR)을 통해 $f_r$이 가장 큰 점에서 복사효과에 의한 소화가 발생하였으며, 화염신장 소화점에서는 IHRR이 가장 높지만 화염에서의 전도에 의한 열손실로 인해 소화가 되는 것을 확인하였다. 복사는 화염신장 소화점에는 거의 영향이 없지만 복사 소화점과 점화점에는 큰 영향을 주는 것을 알 수 있었다. 또한 연료의 온도가 높아질수록 복사에 의한 소화점의 스트레인율과 화염신장에 의한 스트레인율 사이의 영역이 넓어지게 되어 화염 안정성이 향상되고 있음을 알 수 있었다.

복사 열손실로 인한 확산 화염의 맥동 불안정에 관한 연구 (Radiation-Induced Oscillatory Instability in Diffusion Flames)

  • 손채훈;김종수
    • 대한기계학회논문집B
    • /
    • 제23권9호
    • /
    • pp.1185-1191
    • /
    • 1999
  • Radiation-induced oscillatory instability in diffusion flames is numerically investigated with nonlinear dynamics considered. As the simplest flame model, a diffusion flame established in the stagnant mixing layer is employed with optically thin gas-phase radiation and unity Lewis numbers for all species. Attention is focused on the radiation-induced extinction regime, which occurs at large $Damk\ddot{o}hler$ number. Once the steady flame structure is obtained for a prescribed value of the initial $Damk\ddot{o}hler$ number, transient solution of the flame is calculated after a finite amount of the $Damk\ddot{o}hler$-number perturbation is imposed on the steady flame. Transient evolution of the flame exhibits three types of flame-evolution behaviors, namely decaying oscillatory solution, diverging solution to extinction and stable limit-cycle solution. A dynamic extinction boundary is identified for laminar flamelet library.

층류제트 부상화염에서 열손실에 의한 자기진동에 관한 연구 (Study on Heat-Loss-Induced Self-Excitation in Laminar Lifted Jet Flames)

  • 윤성환;박정;권오붕;김정수;배대석;윤진한;길상인
    • 대한기계학회논문집B
    • /
    • 제35권3호
    • /
    • pp.309-319
    • /
    • 2011
  • 질소 희석된 프로판 부상화염에서 열손실에 의한 자기진동을 기초로 화염안정화선도를 도출하기 위하여 노즐직경 0.3 mm, 1.0 mm에서 실험적 연구를 수행하였다. 예혼합화염에서 확산화염으로의 전도 열손실에 의한 자기진동 및 매연 복사에 의한 자기진동을 관찰하였다. 0.1 Hz보다 낮은 주파수 성향을 띄는 열손실에 의한 자기진동은 제안된 메커니즘에 의해 잘 묘사되었고 반면 매연복사에 의한 자기진동은 O(0.1 Hz)의 주파수 범위를 나타내었으며 제안된 메커니즘은 항온항습실 실험을 통해 입증하였다. 질소 희석된 프로판 부상화염에서 관찰된 열손실에 의한 자기진동의 특성화는 관련된 변수 및 스트라훌 수에 의해 잘 묘사되었다.

복사열을 이용한 샌드위치 패널 심재의 연소특성 분석 (A Combustion Characteristic Analysis of Sandwich Panel Core Using Radiation Heat Flux)

  • 박형주
    • 한국화재소방학회논문지
    • /
    • 제21권4호
    • /
    • pp.25-31
    • /
    • 2007
  • 본 연구에서는 샌드위치 패널 심재에 대한 연소열과 일정한 외부 복사열에 의한 연소특성을 분석하였다. 일정한 외부 복사열원에 노출된 샌드위치 패널 심재의 착화시간, 임계열유속, 착화온도, 시료 표면 온도의 변화를 측정하기 위해 3가지 Type의 시료를 사용하였으며, 연소열을 측정하기 위해 Oxygen bomb calorimeter를, 연소특성을 측정하기 위해 Mass loss calorimeter를 사용하였다. 연소특성을 측정하기 위해 $100\;mm{\times}100\;mm{\times}50\;mm$ 크기의 시료를 사용하였다. 연구결과, 연소열과 착화온도에 있어서 가장 좋은 특성을 갖는 것은 Type B인 반면 임계열유속과 시료 표면온도 변화에 있어서는 Type C에서 가장 좋은 특성을 나타내었다. 모든 연구 데이터를 종합한 결과 Type C가 가장 좋은 화재안정성을 나타낸다는 것을 알 수 있었다. 향후, 샌드위치 패널 심재에 대한 열방출률 특성과 질량감소속도에 대한 실험연구가 필요할 것으로 판단된다.

Remote Nozzle Blocking Device of RCS Pipe during Mid-Loop Operation in Nuclear Power Plants

  • Kang, Ki-Sig;Lee, Se-Yub;Chi, Ham-Chung
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 춘계학술발표회논문집(1)
    • /
    • pp.571-576
    • /
    • 1996
  • Currently most nuclear power plants(NPPs) are adopted the mid-loop operation to minimize the overhaul period and save the operating cost. For mid-loop operation it is essential to install nozzle dam between RCS pipe and steam generator(SG). Because SG remains more highly contaminated with radioactive material than any other parts of the NPPs, the repairmen are very reluctant to carry out installing nozzle dam inside the SG. Until now, unfortunately, it appears that no practically applicable device was developed to provide the longstanding demand. Also the accidents have been reported by licenser event report during this operation mode due to loss of residual heat removal(RHR). The purpose of this paper is to conduct remotely blocking and disintegration of nozzle of a SG which has the highest radiation exposure during the maintenance in NPPs. The remote nozzle blocking device of a SG includes three bladders, hubs, air controller provisions to supply and contact air pressure into the bladders. This remote nozzle block device will give the larger operation margin to prevent the loss of RHR and minimize the radiation exposure dose to the repairman and shorten the overhaul periods.

  • PDF