• 제목/요약/키워드: Radiation field Size

검색결과 389건 처리시간 0.027초

통방융합용 소형 모바일 안테나 및 근거리장 특성 (Compact mobile antenna and near field characterization for Communication Broadcasting Convergence)

  • 강정진
    • 한국인터넷방송통신학회논문지
    • /
    • 제8권5호
    • /
    • pp.43-49
    • /
    • 2008
  • 통방융합서비스가 가시화되면서 성능이 더욱 우수한 안테나 모델을 개발하기 위해 다양한 기술적 접근이 시도되고 있다. 본 논문은 핸드폰에 부착할 수 있고, 통방융합용에 적용할 수 있는 소형모바일 안테나를 제안한다. 모바일 핸드셑용 안테나 설계에서, 크기축소는 중요한 요소 중의 하나이며, 루프안테나의 소형화는 접어진 다이폴을 굽힘으로서 실현된다. 짧은 평면 다이폴은 더 큰 입력저항을 만들기 위해 두 배의 접어진 다이폴과 루프안테나로 변환된다. 그 안테나의 전류분포는 루프 안테나와 같고, 방사패턴은 전방향 특성을 갖는다. 또한 전기광학효과 맵핑 시스템을 이용하여 전류유기 근거리장 방사패턴에 의해 RFID안테나의 성능을 분석한다.

  • PDF

[ $Bi_2Sr_2CaCu_2O{8+\delta}$ ] Intrinsic Josephson Junctions in a Parallel Magnetic Field

  • Lee, J.H.;Chong, Yon-Uk;Lee, Su-Youn;Khim, Z.G.
    • Progress in Superconductivity
    • /
    • 제1권2호
    • /
    • pp.110-114
    • /
    • 2000
  • We have investigated the Josephson vortex dynamics in $Bi_2Sr_2CaCu_2O{8+\delta}$ intrinsic Josephson junctions subjected to a magnetic field parallel to $CuO_2$ planes. We investigated mesas with $40\times40{\mu}m^2$ in size and containing 6 and 20. intrinsic junctions. The zero field I-V characteristics exhibited a typical hysteretic, multi-branched nature of the intrinsic Josephson effect. At high magnetic fields (H>1.5 T), I-V characteristics showed flux flow steps. The Swihart velocity obtained from this observation was about $4.2\times10^5$ m/s, which was the lowest mode electromagnetic wave velocity of N coupled stack. The experimental I-V curves fitted well into the simple model of Cherenkov radiation including Ohmic and non-linear dissipation terms. This suggests that the dissipation mechanism of Josephson vortex be due to both Cherenkov radiation and quasiparticle tunneling current.

  • PDF

Analytical Anisotropic Algorithm을 사용한 폐암 치료 시 MU 검증 프로그램 적용에 관한 고찰 (Examinations on Applications of Manual Calculation Programs on Lung Cancer Radiation Therapy Using Analytical Anisotropic Algorithm)

  • 김종민;김대섭;홍동기;백금문;곽정원
    • 대한방사선치료학회지
    • /
    • 제24권1호
    • /
    • pp.23-30
    • /
    • 2012
  • 목 적: Analytical Anisotropic Algorithm (AAA)을 사용하여 계산된 폐 부위 방사선치료계획은 Pencil Beam Convolution (PBC) Algorithm 기반의 MU 검증 프로그램을 이용하였을 때 MU의 오차가 발생하여 MU 검증 프로그램 사용에 어려움이 있다. 본원에서는 AAA를 사용하여 계산된 치료계획을 검증할 방법에 대하여 연구하였다. 대상 및 방법: Eclipse treatment planning system (Version 8.9, Varian, USA)을 사용하여 폐 부위 정위적체부방사선치료(Stereotactic Body Radiation Therapy, SBRT) 7건에서의 총 57개 조사야(Field) 각각에 대하여 선량계산 알고리즘으로 PBC와 AAA를 사용하여 계산하였다. 수립된 치료계획의 MU를 자체 개발하여 사용 중인 MU 검증 프로그램의 MU와 비교 분석하였다. PBC 알고리즘과 AAA에서 발생한 오차에 영향을 미칠 수 있는 조사야크기(Field size), 방사선이 폐 조직을 통과한 거리, 방사선이 종양 조직을 통과한 거리, 유효깊이(Effective depth) 등 4가지 변수에 대하여 오차와의 상관관계를 상용 프로그램을 이용하여 분석하였다. 결 과: PBC 알고리즘의 오차는 $0.2{\pm}1.0%$로 나타났으며 AAA의 오차는 $3.5{\pm}2.8%$로 나타났다. 또한, 오차에 영향을 미칠 수 있는 4가지 변수에 대해 분석한 결과, 방사선이 폐 조직을 통과한 거리와 MU의 오차와의 관계에서 상관계수 0.648 (P=0.000)로 유의하게 증가하였고, ${\Delta}_{AAA}$=L.P 0.00903+0.02048이라는 MU 보정인자를 산출해 낼 수 있었으며 MU 보정인자를 MU 검증 프로그램에 적용한 결과, 적용 전 $3.5{\pm}2.8%$의 오차는 $0.4{\pm}2.0%$ 이내로 줄어들었다. 결 론: 본 연구에서는 방사선이 폐 조직을 통과한 거리가 커질수록 MU 검증 프로그램과의 오차가 커짐을 알아냈으며, MU보정인자라는 간단한 방법을 통해 AAA 알고리즘의 MU를 검증할 수 있게 되었다.

  • PDF

Long-term outcomes of surgery and radiotherapy for secreting and non-secreting pituitary adenoma

  • Kim, Mi Young;Kim, Jin Hee;Oh, Young Kee;Kim, El
    • Radiation Oncology Journal
    • /
    • 제34권2호
    • /
    • pp.121-127
    • /
    • 2016
  • Purpose: To investigate treatment outcome and long term complication after surgery and radiotherapy (RT) for pituitary adenoma. Materials and Methods: From 1990 to 2009, 73 patients with surgery and RT for pituitary adenoma were analyzed in this study. Median age was 51 years (range, 25 to 71 years). Median tumor size was 3 cm (range, 1 to 5 cm) with suprasellar (n = 21), cavernous sinus extension (n = 14) or both (n = 5). Hormone secreting tumor was diagnosed in 29 patients; 16 patients with prolactin, 12 patients with growth hormone, and 1 patient with adrenocorticotrophic hormone. Impairment of visual acuity or visual field was presented in 33 patients at first diagnosis. Most patients (n = 64) received RT as postoperative adjuvant setting. Median RT dose was 45 Gy (range, 45 to 59.4 Gy). Results: Median follow-up duration was 8 years (range, 3 to 22 years). In secreting tumors, hormone normalization rate was 55% (16 of 29 patients). For 25 patients with evaluable visual field and visual acuity test, 21 patients (84%) showed improvement of visual disturbance after treatment. The 10-year tumor control rate for non-secreting and secreting adenoma was 100% and 58%, respectively (p < 0.001). Progression free survival rate at 10 years was 98%. Only 1 patient experienced endocrinological recurrence. Following surgery, 60% (n = 44) suffered from pituitary function deficit. Late complication associated with RT was only 1 patient, who developed cataract. Conclusion: Surgery and RT are very effective and safe in hormonal and tumor growth control for secreting and non-secreting pituitary adenoma.

소조사면 광자선의 팬톰산란인수 결정 (Determination of Phantom Scatter Factors for Small Photon Fields)

  • 오영기;최태진;김진희;김옥배
    • 한국의학물리학회지:의학물리
    • /
    • 제20권2호
    • /
    • pp.106-111
    • /
    • 2009
  • 본 연구에서는 얇은 엠엘씨 등을 사용하여 불규칙한 모양의 조사면으로 방사선수술을 시행하거나 필수적으로 소조사면을 포함할 수 밖에 없는 세기조절 방사선치료를 위해 중요한 요소인 소조사면의 출력인수 $S_{cp}$를 측정하였고 동일한 위치의 공기중에서 물등가 재질로 만든 선량증가두겁을 이용하여 제한기산란인수 $S_c$를 측정함으로서 이 결과를 이용하여 팬톰산란인수 $S_p$를 계산하였다. $S_{cp}$의 측정에서 기준 측정기인 0.125 cc 부피의 이온전리함과 이극소자측정기의 결과는 잘 일치하고 있으나 0.015 cc 부피의 소형 이온전리함의 결과는 $4.2{\times}4.2\;cm^2$ 이상의 조사면에서는 1~4% 정도 낮게 나타났고 $1.8{\times}1.8\;cm^2$, 이하의 소조사면에서는 이극소자측정기에 비해 8~16% 낮게 측정되었다. 물등가 재질로 만든 선량증가 두겁을 덮은 이극소자 측정기를 이용한 Sc의 측정은 전자오염 등으로 인해 약간의 오차를 보여주고 있으나 전체적인 추세는 잘 일치하고 있음을 확인하였고 이 결과들을 이용하여 계산한 Sp는 다른 연구결과들의 범주에 포함되는 결과를 얻었다.

  • PDF

가상쐐기와 기존쐐기의 물리적 특성 비교 (Physical Characteristics Comparison of Virtual Wedge Device with Physical Wedge)

  • 조정근;최계숙;임청환;김정구;정홍량;이정옥;이만구
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제24권2호
    • /
    • pp.49-52
    • /
    • 2001
  • We compared the characteristics of Siemens virtual wedge device with physical wedges for clinical application. We investigated the characteristics of virtual and physical wedges for various wedge angles (15, 30, 45, and 60) using 6- and 15-MV photon beams. Wedge factors were measured in water using an ion chamber for various field sizes and depths. In case of virtual wedge device, as upper jaw moves during irradiation, wedge angles were estimated by accumulated doses. These measurements were performed at off-axis points perpendicular to the beam central axis in water for a $15\;cm\;{\times}\;20\;cm$ radiation field size at the depth of 10 cm. Surface doses without and with virtual or physical wedges were measured using a parallel plate ion chamber at surface. Field size was $15\;cm\;{\times}\;20\;cm$ and a polystyrene phantom was used. For various field sizes, virtual and physical wedge factors were changed by maximum 2.1% and 3.9%, respectively. For various depths, virtual and physical wedge factors were changed by maximum 1.9% and 2.9%, respectively. No major difference was found between the virtual and physical wedge angles and the difference was within 0.5. Surface dose with physical wedge was reduced by maximum 20% (x-ray beam : 6 MV, wedge angle : 45, SSD : 80 cm) relative to one with virtual wedge or without wedge. Comparison of the characteristics of Siemens virtual wedge device with physical wedges was performed. Depth dependence of virtual wedge factor was smaller than that of physical wedge factor. Virtual and physical wedge factors were nearly independent of field sizes. The accuracy of virtual and physical wedge angles was excellent. Surface dose was found to be reduced using a physical wedge.

  • PDF

임의의 위치에 가상 인텐시티 형성 방법: 방법론과 그 물리적 의미 (A method to generate virtual intensity at arbitrary position: Methodology and its physical meanings)

  • 최정우;김양한
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.652-657
    • /
    • 2003
  • This paper proposes a method to generate virtual intensity field in space. The sound field of a zone enclosing the listener position is controlled to have maximum acoustic intensity to the desired direction. In order to control acoustic intensity of a zone, space-averaged active intensity is introduced. The ratio of space-averaged active intensity and control effort is defined as a cost function and expressed as a function of source control signals. It is shown that the cost function represents radiation efficiency of multiple sources. The control signals maximizing the cost function is found through eigenvalue analysis. The proposed method is verified by numerical simulations performed in free field condition, and the results provide a relation between wavelength and the size of controllable intensity field.

  • PDF

유양돌기 방사선검사 시 조사야 사용법에 따른 영상의 유용성 평가 (Evaluation of the Usefulness of Images according to the Use of the Field Size in Mastoid Process Radiography)

  • 정홍량
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권5호
    • /
    • pp.435-441
    • /
    • 2021
  • The purpose of this study was to evaluate the quality of images and to quantitatively measure and analyze the dose of scattered ray to the organs, which were highly sensitive to radiation according to the use of cylinder cone in mastoid process radiography. When the cylinder cone was not used, the SID was 100cm and the field size was 24 × 36 cm(864 cm2). When using the cylinder cone which was a circle, the SID was 70 cm, the radius was 10.5 cm and field size was 86.59 cm2. As a result of the study, SNR of the image quality evaluation was measured to be 2.58 for Law method and 3.90 for Stenver's method when not using cylinder cone, and 2.87 for Law method and 14.67 for Stenver's method when using cylinder cone. CNR was measured to be 0.03 for Law method and 0.04 for Stenver's method when cylinder cone was not used, and 0.04 for Law method and 0.05 for Stenver's method when using cylinder cone. When the cylinder cone was not used, the scattered ray dose was measured to be 0.10 mGy in the right eyeball, 0.30 mGy in the left eyeball, 2.02 mGy in the parotid gland, and 0.29 mGy in the thyroid gland for Law method and to be 0.03 mGy in the right eyeball, 0.12 mGy in the left eyeball, 1.43 mGy in the parotid gland, and 0.09 mGy in the thyroid gland for Stenver's method. When the cylinder cone was used, the scattered ray dose was measured to be 0.05 mGy in the right eyeball, 0.03 mGy in the left eyeball and the parotid and thyroid gland were below the measurable values for Law method and all areas were below the measurable values for Stenver's method. This was found to be statistically significant(p<0.000).

안와 주변 방사선 치료 시 수정체 피폭선량 감소를 위한 2차 차폐의 유용성 평가 (Usefulness assessment of secondary shield for the lens exposure dose reduction during radiation treatment of peripheral orbit)

  • 곽용국;홍순기;하민용;박장필;유숙현;조웅
    • 대한방사선치료학회지
    • /
    • 제27권1호
    • /
    • pp.87-95
    • /
    • 2015
  • 목 적 : 안와 주변 방사선 치료 시 수정체 피폭선량감소를 위하여 사용된 2차 차폐 block의 유용성을 알아보고자 한다. 대상 및 방법 : Human phantom(Alderson Rando Phantom, The Phantom Laboratory, USA)을 사용하여 CT(Somatom Definition AS, Siemens, Germany) 모의촬영 후 전산화치료계획시스템(Pinnacle, PHILIPS, USA)을 통해 실제 치료와 유사한 IMRT치료계획을 실시하였다. 2차 차폐를 위하여 두께 3mm 지름 25 mm의 납판과 3 mm tungsten eye-shield block(Extra small size, Radiation Products Design, Inc, USA)를 사용하였으며, TPS(Treatment Planning System) 상의 lens dose와 모의치료 상의 lens dose를 OSLD로 측정 비교하였다. 또한, 5 cm 두께의 acrylic phantom에 동일한 조건의 2차 차폐물인 3 mm 납판과 tungsten eye-shield block을 사용하여 200 MU(6 MV, SPD(Source to Phantom Distance)=100 cm, $F{\cdot}S\;5{\times}5cm$)를 조사 및 측정하였으며, 조사야 밖의 누설선 및 투과방사선 영향을 제한시키고자 8 cm 납블럭(O.S.B: Outside Scatter Block)을 적용하여 위와 동일한 실험을 시행하였다. 조사야로부터 1 cm 이격하여 phantom 끝 옆면에 OSLD(Optically Stimulated Luminescence Dosimeter)를 부착하였고, eyelid의 두께에 해당하는 bolus 3 mm를 적용하였다. 결 과 : human phantom을 이용하여 IMRT 치료계획 상의 Lens dose와 실 측정치는 각각 315.9, 216.7 cGy가 측정되었고, 3 mm 납판과 tungsten eye-shield block으로 2차 차폐 후 각각 234.3, 224.1 cGy가 측정되었다. acrylic phantom을 이용한 실험 결과는 no block, 3 mm 납판, tungsten eye-shield block을 사용했을 때 5.24, 5.42, 5.39 cGy가 측정되었으며, 조사야 밖에 O.S.B를 적용하여 no block, 3 mm 납판, tungsten eye-shield block을 실험한 결과 각각 1.79, 2.00, 2.02 cGy가 측정되었다. 결 론 : 광자선 조사 시 critical organ을 보호하기 위하여 2차 차폐를 적용할 시에는 field 외부일지라도 헤드 누설방사선 및 collimator & MLC 투과방사선이 존재하므로 치료부위와 beam 방향에 따라 금속과 같은 높은 원자번호의 차폐물질이 critical organ근처에 있다면 선량 증가의 원인이 될 수 있다는 사실을 알 수 있었다. 따라서 피폭선량 감소를 위한 2차 차폐의 시도는 분명 의미가 있었으나 미 검증된 시도는 오히려 역효과를 가져올 수 있다는 사실을 인지하여 QA를 통해 목적에 부합하는 결과가 나오는지를 사전에 알아보아야 할 것이다.

  • PDF

의료용 선형가속기의 X-선 분포도 측정을 위한 1차원 광섬유 방사선 센서의 제작 및 성능평가 (Fabrication and performance evaluation of one-dimensional fiber-optic radiation sensor for X-ray profile irradiated by clinical linear accelerator)

  • 조동현;장경원;유욱재;이봉수;조효성;김신
    • 센서학회지
    • /
    • 제16권1호
    • /
    • pp.33-38
    • /
    • 2007
  • In this study, one-dimensional fiber-optic radiation sensor with an organic scintillator tip is fabricated to measure high energy X-ray beam profile of CLINAC. According to the energy and field size of X-ray, scintillating light signal from one-dimensional fiber-optic sensor is measured using a photodiode-amplifier system. This sensor has many advantages such as high resolution, real-time measurement and ease calibration over conventional ion chamber and film.