• Title/Summary/Keyword: Radiation field

Search Result 2,227, Processing Time 0.031 seconds

A Study on the dosimetry in boundary of shielding block in high energy irradiation (고에너지 방사선치료에서 차폐물 경계부위의 선량분포에 관한 고찰)

  • Kim, Myung-Se;Kim, Sung-Kyu;Shin, Sei-One
    • Journal of Yeungnam Medical Science
    • /
    • v.7 no.2
    • /
    • pp.115-120
    • /
    • 1990
  • Scatter-air ratios are used for the purpose of calculating scattered dose in the medium. The computation of the primary and the scattered dose separately is particularly useful in the dosimetry of irregular fields with shielding block in radiation field, dose distribution of scattered radiation using 18MeV Linear accelerator and Co-50 teletherapy measured. The effect of scattered radiation dose by protecting block was been ignored in radiation therapy, 2-3% of scattered radiation may be 90-200 cGy which could be influence vitial complications such as cataract, oligospermia or sterility. So that exect calculation of such scattered radiation especially for large field $\bar{c}$ small protection of vitial organ is very important. The purpose of this article is to calculate scattered radiation by protecting block exactly for irregular field $\bar{c}$ Linac or Co-60 irradiation and to applicate these data in clinical radiation field. Authors could obtain following results. 1. The lesser angle between shielding block showed more scattered radiation. 2. With decreasing distance between shielding blocks, the dependent of scattered radiation were increased. 3. Output of 18MeV Linear accelerator and Co-60 was related linear proportion on field size, but independent according to the size of shielding block in 18MeV Linear accelerator.

  • PDF

Cross Correlated Effects of Radiation Damping and the Distant Dipolar Field with a Pulsed Field Gradient in Solution NMR

  • Chung Kee-Choo;Ahn Sang-Doo
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.10 no.1
    • /
    • pp.46-58
    • /
    • 2006
  • With a simple pulse sequence ($\pi/2$-{gradient, duration T}-acquisition) in solution NMR, detected signal has slowly grown up to percents of the equilibrium magnetization. The source of this unusual resurrection of dephased magnetization after a crushed gradient is cross-correlated effects of radiation damping and the distant dipolar field, which has been demonstrated by a numerical simulation and theoretical analysis.

  • PDF

The Radiation Spot Size due to Wiggler Errors in a Free-Electron Laser Oscillator

  • Nam, Soon-Kwon;Park, Y.S.
    • Journal of the Korean Physical Society
    • /
    • v.73 no.10
    • /
    • pp.1495-1501
    • /
    • 2018
  • We have developed an extended three-dimensional free-electron laser (3D FEL) code with source-dependent expansion to calculate the intensity of the radiation field and the spot size in a free-electron laser oscillator. The effect of the wiggler field errors was evaluated for the case of a planar wiggler generated by a magnet stack with parabolic shaped pole faces by using the extended three-dimensional equations in a free-electron laser oscillator based on the proposed FEL facility which is to be operated in the far-infrared and the infrared regions. The radiation spot size due to the wiggler field errors also have been analyzed for wiggler errors of ${\Delta}B/B=0.0$, 0.03, 0.06 and 0.09% at z = 1 m and z = 2 m. The effect of the diffraction of radiation field due to the wiggler field errors of ${\Delta}B/B=0.0$ and ${\Delta}B/B=0.09%$ at 200 passes was evaluated by using the extended 3D code that we developed. The variation of the curvature of the phase front and the effect of the radiation field intensity due to the wiggler field errors were also evaluated for B = 0.5 T and B = 0.7 T with the wiggler error of ${\Delta}B/B=0.09%$ at 200 passes and the results were compared to those of without errors. The intensity of the radiation, behavior of the radiation spot size and the variation of the curvature of the phase were highly sensitive to the wiggler error of ${\Delta}B/B$ > 0.09%, but were less sensitive to the wiggler errors for ${\Delta}B/B$ < 0.09% in a free-electron laser (FEL) oscillator based on the proposed FEL facility.

An Analysis of Radiation Field Characteristics for Estimating the Extremity Dose in Nuclear Power Plants (원전 종사자의 말단선량평가를 위한 고피폭 접촉 방사선장 특성분석)

  • Kim, Hee-Geun;Kong, Tae-Young
    • Journal of Radiation Protection and Research
    • /
    • v.34 no.4
    • /
    • pp.176-183
    • /
    • 2009
  • Maintenance on the water chamber of steam generator during outage in nuclear power plants (NPPs) has a likelihood of high radiation exposure to whole body of workers even short time period due to the high radiation exposure rates. In particular, it is expected that hands would receive the highest radiation exposure because of its contact with radiation materials. In this study, characteristic analysis of inhomogeneous radiation fields for contact operations was conducted using thermoluminescent dosimeter (TLD) readouts from the application tests of two-dosimeter algorithm to Korean NPPs in 2004. It is regarded that inhomogeneous radiation fields for contact operations in NPPs are dominated by high energy photons. In addition, field tests for workers who participated in maintenance on the steam generator during outage at Ulchin NPPs in 2009 and pressure tube replacement at Wolsong NPPs in 2009 were conducted to analyze radiation fields and to estimate the extremity dose. As a result, radiation fields were dominated by high energy photons.

Importance of PET/CT Scan Use in Planning Radiation Therapy for Lymphoma

  • Milana, Mitric-Askovic;Marko, Erak;Miroslav, Latinovic;Tihomir, Dugandzija
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.5
    • /
    • pp.2051-2054
    • /
    • 2015
  • Background: Radiation therapy is a key part of the combined modality treatment for Hodgkin's lymphoma (HL) and non-Hodgkin's lymphoma (NHL), which can achieve locoregional control of disease. The 3D-conformal radiation oncology can be extended-field (EFRT), involved-field (IFRT) and involved node (INRT). New techniques have resulted in a smaller radiation field and lower dose for critical organs such as lung heart and breast. Materials and Methods: In our research, we made a virtual simulation for one patient who was treated in four different radiotherapeutic techniques: mantle field (MFRT), EFRT, IFRT and INRT. After delineatiion we compared dose-volume histograms for each technique. The fusion of CT for planning radiotherapy with the initial PET/CT was made using Softver Xio 4.6 in the Focal program. The dose for all four techniques was 36Gy. Results: Our results support the use of PET/CT in radiation therapy planning. With IFRT and INRT, the burden on the organs at risk is less than with MFRT and EFRT. On the other hand, the dose distribution in the target volume is much better with the latter. Conclusions: The aim of modern radiotherapy of HL and NHL is to reduce the intensity of treatment and therefore PET/CT should be used to reduce and not increase the amount of tissue receiving radiation.

Optimized inverse distance weighted interpolation algorithm for γ radiation field reconstruction

  • Biao Zhang;Jinjia Cao;Shuang Lin;Xiaomeng Li;Yulong Zhang;Xiaochang Zheng;Wei Chen;Yingming Song
    • Nuclear Engineering and Technology
    • /
    • v.56 no.1
    • /
    • pp.160-166
    • /
    • 2024
  • The inversion of radiation field distribution is of great significance in the decommissioning sites of nuclear facilities. However, the radiation fields often contain multiple mixtures of radionuclides, making the inversion extremely difficult and posing a huge challenge. Many radiation field reconstruction methods, such as Kriging algorithm and neural network, can not solve this problem perfectly. To address this issue, this paper proposes an optimized inverse distance weighted (IDW) interpolation algorithm for reconstructing the gamma radiation field. The algorithm corrects the difference between the experimental and simulated scenarios, and the data is preprocessed with normalization to improve accuracy. The experiment involves setting up gamma radiation fields of three Co-60 radioactive sources and verifying them by using the optimized IDW algorithm. The results show that the mean absolute percentage error (MAPE) of the reconstruction result obtained by using the optimized IDW algorithm is 16.0%, which is significantly better than the results obtained by using the Kriging method. Importantly, the optimized IDW algorithm is suitable for radiation scenarios with multiple radioactive sources, providing an effective method for obtaining radiation field distribution in nuclear facility decommissioning engineering.

The Gauge Invariant Formulation for the Interaction of the Quantized Radiation Field with Matter

  • 이덕환
    • Bulletin of the Korean Chemical Society
    • /
    • v.20 no.6
    • /
    • pp.720-726
    • /
    • 1999
  • It has been proved by the semi-classical gauge invariant formulation (GIF) that the correct interaction operator for coupling the field-free material states with the radiation field must be the position form regardless of the gauge chosen for expressing the electromagnetic potentials, in accordance with the well-established principle of gauge invariance. The semi-classical GIF is now extended to the quantized radiation field interacting with matter by defining the energy operator for the quantized radiation field in the presence of matter. It will be shown in this paper that the use of the energy operator guarantees the position form of the interaction operator even in the Coulomb gauge, contrary to the conventional approach in which the dark material Hamiltonian is used to get the interaction operator of the momentum form. The multipolar Hamiltonian is examined in the context of the quantum mechanical gauge transformation.

The effective of Radiation Pattern on Two Shape of Slot Antenna

  • Chanwattanapong, W.;Anantrasirichai, N.;Wakabayachi, T.
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1660-1663
    • /
    • 2003
  • This paper present the characteristics of radiation pattern of microstrip slot antenna on the ground plane fed by microstrip line. It is proposed for resonance frequency at 10 GHz. We will analysis two shape of slot antenna; double L-shape slot antenna and U-shape slot antenna. In this case, we will compare far-field radiation pattern of two shape slot antenna. Far-field radiation pattern of double L-shape slot antenna is bi-directional nevertheless U-shape slot antenna is uni-directional. The microstrip slot antenna is propose to analyze far-field radiation pattern for use in the wireless communication systems

  • PDF

Feasibility of Shrinking Field Radiation Therapy through 18F-FDG PET/CT after 40 Gy for Stage III Non-Small Cell Lung Cancers

  • Ding, Xiu-Ping;Zhang, Jian;Li, Bao-Sheng;Li, Hong-Sheng;Wang, Zhong-Tang;Yi, Yan;Sun, Hong-Fu;Wang, Dong-Qing
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.1
    • /
    • pp.319-323
    • /
    • 2012
  • Objective: To explore the feasibility of shrinking field technique after 40 Gy radiation through 18F-FDG PET/CT during treatment for patients with stage III non-small cell lung cancer (NSCLC). Methods: In 66 consecutive patients with local-advanced NSCLC, 18F-FDG PET/CT scanning was performed prior to treatment and repeated after 40 Gy. Conventionally fractionated IMRT or CRT plans to a median total dose of 66Gy (range, 60-78Gy) were generated. The target volumes were delineated in composite images of CT and PET. Plan 1 was designed for 40 Gy to the initial planning target volume (PTV) with a subsequent 20-28 Gy-boost to the shrunken PTV. Plan 2 was delivering the same dose to the initial PTV without shrinking field. Accumulated doses of normal tissues were calculated using deformable image registration during the treatment course. Results: The median GTV and PTV reduction were 35% and 30% after 40 Gy treatment. Target volume reduction was correlated with chemotherapy and sex. In plan 2, delivering the same dose to the initial PTV could have only been achieved in 10 (15.2%) patients. Significant differences (p<0.05) were observed regarding doses to the lung, spinal cord, esophagus and heart. Conclusions: Radiotherapy adaptive to tumor shrinkage determined by repeated 18F-FDG PET/CT after 40 Gy during treatment course might be feasible to spare more normal tissues, and has the potential to allow dose escalation and increased local control.