• Title/Summary/Keyword: Radiation exposures

Search Result 99, Processing Time 0.023 seconds

Effects of Ultraviolet Radiation on the Skin (자외선에 의한 피부반응)

  • Youn, Jail-Il
    • Journal of Radiation Protection and Research
    • /
    • v.20 no.3
    • /
    • pp.181-186
    • /
    • 1995
  • UV irradiation causes a variety of biologic effects on the skin. These effects can be devided to acute reactuons and chronic reacxtions by duration of UV irradiation. Acute reactions are erythema reaction, pigment reactions and changes in epidermal thickness. Among them erythema reaction is most common and conspicuous acute effects of the skin. Upon exposure to sun or artificial UV soures, a faint redness response of skin may begin. Larger exposure causes sunburn reaction which is exaggerated erythema reactionassociated with pain, swelling, vesicle and dulla. Extent and time course of erythema reaction depend upon several factors including wavelength and dose of UVR, skin conditions likeas skin type, site, color, temperature, humidity and environmental factors. Evaluation of erythema erythema induced by UV irradiation is difficult to quantify. Degree of redness of skin are usually estimated by subjective visual evaluation. The lowest exposure dose required to protuce erythema is called minimal erythema dose (mod). Repeated exposures of UVR result in photaging skin. In this condition we can see wrinkling, skin atrophy, dilated blood vessels and keratoses. In sensitive persons photocarcinogenesis is can Be developed on exposed area of skin. Recently skin canser is increasing now in our country. An effective public education and photopreventive method must be developed.

  • PDF

Performance Evaluation of an Electrometer for Quality Control and Dosimetry in Radiation Therapy (방사선 치료의 정도관리 및 선량측정에 이용되는 전리계의 성능평가)

  • Kim, Chang-Seon;Kim, Chul-Yong;Park, Myung-Sun
    • Progress in Medical Physics
    • /
    • v.11 no.2
    • /
    • pp.123-130
    • /
    • 2000
  • The performance of an electrometer directly affects on the accuracy and precision in radiation dosimetry. This study is to list of the quality control for maintaining performance and to perform evaluation tests of an electrometer. Performance tests selected include proper polarizing voltages, warm-up and equalization time, leakages, long-term stability, linearity, and effect of ambient conditions. An electrometer connected with a rigid stem ionization chamber was evaluated with a Strontium-90 check device. Bias voltage was measured directly on the input socket. Equalization time is the time required for reaching threshold of charged state after the power is on or the bias voltage is changed. Pre- and post-signal leakages are defined as the accumulation of signal with no exposure and after exposure, respectively. Over three months period, the electrometer's long-term stability was measured by comparison of the temperature-pressure corrected readings. Linearity was expressed as the deviation of readings from multiple short exposures from one continuous exposure. Effect of ambient conditions was expressed as the zero drift of the electrometer over 17-34$^{\circ}C$ temperature ranges. For two nominal values, 300 and 500 volts, measured voltages were lower by 2.5 and 5.8%, respectively. The warm-up time, 20 minutes, was longer than the lamp time by 9 minutes and the equalization time was less than 1 minute. Without exposure, the zero-drift was 0.002 scale-unit in 15 minutes and the leakage after 10 minutes exposure was minimal. The IQ-4 was stable over 99.4% for three-month periods. Deviation from the linearity was 0.9% for measurement scale, 0.000-9.991. Over 17-34$^{\circ}C$ temperature range, the zero-drift was minimal, less than 0.2%. For a clinically-used electrometer, a list for the basic peformance evaluations is proposed. By running this program, the measurement error using an electrometer can be reduced and in turn the improvement in accuracy and precision of radiation dosimetry can be achieved.

  • PDF

Radon Exhalation from Five Wood Species

  • Lee, Ju Yong;Choi, Gyu Woong;Kang, Seog Goo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.46 no.6
    • /
    • pp.735-747
    • /
    • 2018
  • Radon radiation exposures in home have been posed as a potential cancer hazard. This research aims to present the basic data of the indoor radon concentration level by examining the radon exhalation rates of wood species. Radon exhalation rates from five commonly used wood species in Korean wood building construction were measured with Continuous Radon Monitor (CRM), Model 1028 (Sun Nuclear Co., USA) using the Closed Chamber Method (CCM). The mass exhalation rate was observed to vary from $0.00089Bq{\cdot}kg^{-1}{\cdot}h^{-1}$ to $0.00181Bq{\cdot}kg^{-1}{\cdot}h^{-1}$, whereas the surface exhalation rate was observed to be $0.00677-0.01517Bq{\cdot}m^{-2}{\cdot}h^{-1}$. The radon exhalation rate of Quercus accutissima Carruth (white oak) which has the highest density showed the highest figure among the five wood species, on the other hand, the rest of four species showed similar results which were similar to the radon exhalation rates of wood in the U.S.A. and Canada. The average of the concentration measured by the CCM represented well up to the second half-life period (7.7 days). Because result of these small quantities seems to indicate that radon exhalation from the tested wood species has almost negligible impact, the main culprit of the high indoor radon concentration is clearly derived from the background of surrounding wood house. Therefore, as a safety precaution, infrastructures made of wood materials should be designed with the consideration of influx of radon and built accordingly. Furthermore, it is highly desirable that wood will be needed to use for furniture and interior finishing material in indoor environment.

Ghosting Artifacts in Digital Radiography (디지털 방사선영상에서 고스팅 아티팩트)

  • Jung, Wonhee;Chon, Kwonsu
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.7
    • /
    • pp.377-382
    • /
    • 2014
  • Because of using computer system in the field of medical radiology, many artifacts which can not be seen in film/screen system are being created, especially ghosting artifacts. This artifacts could be yielded by taking advantage of a flat panel Thin-Film Transistor array detector. Ghosting artifacts can be rarely seen in clinical practice when an image that has a high-contrast object within a region of high exposure is quickly followed by another image that puts the high-contrast ghosting image in an area of lower radiation exposure. In this experiment, the ghosting artifacts were minimized for approximately 3 minutes with the unaided eye and almost disappeared for 6 minutes quantitatively between exposures. Moreover, the artifacts were influenced by more tube voltage than current and those depended not upon the number of readout cycles, but upon time.

Comparative Study of the Effective Dose from Panoramic Radiography in Dentistry Measured Using a Radiophotoluminescent Glass Dosimeter and an Optically Stimulated Luminescence Detector

  • Lee, Kyeong Hee;Kim, Myeong Seong;Kweon, Dae Cheol;Choi, Jiwon
    • Journal of the Korean Physical Society
    • /
    • v.73 no.9
    • /
    • pp.1377-1384
    • /
    • 2018
  • Accurate measurement of the absorbed dose and the effective dose is required in dental panoramic radiography involving relatively low energy with a rotational X-ray tube system using long exposures. To determine the effectiveness of measuring the irradiation by using passive dosimetry, we compared the entrance skin doses by using a radiophotoluminescent glass dosimeter (RPL) and an optically stimulated luminescence detector (OSL) in a phantom model consisting of nine and 31 transverse sections. The parameters of the panoramic device were set to 80 kV, 4 mA, and 12 s in the standard program mode. The X-ray spectrum was applied in the same manner as the panoramic dose by using the SpekCalc Software. The results indicated a mass attenuation coefficient of $0.008226cm^2/g$, and an effective energy of 34 keV. The equivalent dose between the RPL and the OSL was calculated based on a product of the absorbed doses. The density of the aluminum attenuators was $2.699g/cm^3$. During the panoramic examination, tissue absorption doses with regard to the RPL were a surface dose of $75.33{\mu}Gy$ and a depth dose of $71.77{\mu}Gy$, those with regard to the OSL were surface dose of $9.2{\mu}Gy$ a depth dose of $70.39{\mu}Gy$ and a mean dose of $74.79{\mu}Gy$. The effective dose based on the International Commission on Radiological Protection Publication 103 tissue weighting factor for the RPL were $0.742{\mu}Sv$, $8.9{\mu}Sv$, $2.96{\mu}Sv$ and those for the OSL were $0.754{\mu}Sv$, $9.05{\mu}Sv$, and $3.018{\mu}Sv$ in the parotid and sublingual glands, orbit, and thyroid gland, respectively. The RPL was more effective than the OSL for measuring the absorbed radiation dose in low-energy systems with a rotational X-ray tube.

Assessment of radionuclides from coal-fired brick kilns on the outskirts of Dhaka city and the consequent hazards on human health and the environment

  • M.M. Mahfuz Siraz;M.D.A. Rakib;M.S. Alam;Jubair Al Mahmud;Md Bazlar Rashid;Mayeen Uddin Khandaker;Md. Shafiqul Islam;S. Yeasmin
    • Nuclear Engineering and Technology
    • /
    • v.55 no.8
    • /
    • pp.2802-2811
    • /
    • 2023
  • In a first-of-its-kind study, terrestrial radionuclide concentrations were measured in 35 topsoil samples from the outskirts of Dhaka using HPGe gamma-ray spectrometry to assess the radiological consequences of such a vast number of brick kilns on the plant workers, general as well as dwelling environment. The range of activity concentrations of 226Ra, 232Th, and 40K is found at 19 ± 3.04 to 38 ± 4.94, 39 ± 5.85 to 57 ± 7.41, and (430 ± 51.60 to 570 ± 68.40) Bq/kg, respectively. 232Th and 40K concentrations were higher than the global averages. Bottom ash deposition in lowlands, fly ash buildup in soils, and the fallout of micro-particles are all probable causes of the elevated radioactivity levels. 137Cs was found in the sample, which indicates the migration of 137Cs from nuclear accidents or nuclear fallout, or the contamination of feed coal. Although the effective dose received by the general public was below the recommended dose limit but, most estimates of hazard parameters surpass their respective population weighted global averages, indicating that brick kiln workers and nearby residents are not safe due to prolonged exposures to terrestrial radiation. In addition, the soil around sampling sites is found to be unsuitable for agricultural purposes.

A Study on the Exposure Parameter and the Patient Dose for Digital Radiography System in Dae Goo (디지털 방사선의학에서의 조사선량 설정과 인지에 대한 실태 - 대구 경북지역을 중심으로 -)

  • Jo, Gwang-Ho;Kang, Yeong-Han;Kim, Bu-Sun
    • Journal of radiological science and technology
    • /
    • v.31 no.2
    • /
    • pp.177-182
    • /
    • 2008
  • Digital imaging for general rediography has many advantages over the film/screen systems, including a wider dynamic range and the ability to manipulate the images produced. The wider range means that acceptable images may by acquired at a range of dose levels, and therefore repeat exposures can be reduced. Digital imaging can result in the over use of radiation, however, because there is a tendency can be reduced. Digital imaging can result in the over use of radiation, however, because there is a tendency for images to be acquired at too high a dose. We investigated the actual exposure dose conditions on general radiography and a questionnaire survey was conducted with radiotechnologiest at medical institutions using digital radiology system. As a results, the dose of exposure was not controlled with patient's figure and dose optimization but was controlled by worker's convenience and image quality. Radio-technologiests often set up the exposure dose regardless of patient figure and body part to be examined. Many organizations, such as the International Commission on Radiological Protection, recommend to keep the dose as low as possible. In addition, they strongly recommend to keep the optimal but minimal dosage by proper training programs and constant quality control, including frequent patient dose evaluations and education.

  • PDF

From Hiroshima to Fukushima: Nuclear and Artist Response in Japan (히로시마에서 후쿠시마까지, 핵과 미술가의 대응)

  • Choi, Tae Man
    • The Journal of Art Theory & Practice
    • /
    • no.13
    • /
    • pp.35-71
    • /
    • 2012
  • The purpose of this essay is to examine the responses of artists on nuclear experiences through an analysis of the nuclear images represented in contemporary Japanese art. Japan has previously as twice experienced nuclear disaster in 20th century. The first atomic bombs were dropped in 1945 as well as the 5th Fukuryumaru, Japanese pelagic fishing boat, exposed by hydrogen bomb test operated by the US in 1954 nearby Bikini atoll. Due to Tsunami taken place by the great earthquake that caused the meltdown of Fukushima Nuclear Power Plant in March 2010, Japan is being experienced a nuclear disaster again. Despite practical experiences, comtemporary Japanese art has avoided the subject of nuclear disasters since the end of the Asia-Pacific War for a variety of reasons. Firstly, GHQ prohibited to record or depict the terrible effect of atomic bomb until 1946. Secondly, Japanese government has tried to sweep the affair under the carpet quite a while a fact of nuclear damage to their people. Because Japan has produced numerous war record paintings during the Second World War, in the aftermath of the defeated war, most of Japanese artists thought that dealing with politics, economics, and social subject was irrelevant to art as well as style of amateur in order to erase their melancholic memory on it. In addition, silence that was intended to inhibit victims of nuclear disasters from being provoked psychologically has continued the oblivion on nuclear disasters. For these reasons, to speak on nuclear bombs has been a kind of taboo in Japan. However, shortly after the atomic bomb dropped on Hiroshima, the artist couple Iri and Toshi Maruki visited to ruin site as a volunteer for Victim Relief. They portrayed the horrible scenes of the legacy of nuclear bomb since 1950 based on their observation. Under the condition of rapid economical growth in 1960s and 1970s, Japanese subculture such as comics, TV animations, plastic model, and games produced a variety of post apocalyptic images recalling the war between the USA and Japanese militarism, and battle simulation based on nuclear energy. While having grown up watching subculture emerged as Japan Neo-Pop in 1990s, New generation appreciate atomic images such as mushroom cloud which symbolizes atomic bomb of Hiroshima. Takashi Murakami and other Neo-Pop artists appropriate mushroom cloud image in their work. Murakami curated three exhibitions including and persists in superflat and infantilism as an evidence in order to analyze contemporary Japanese society. However, his concept, which is based on atomic bomb radiation exposure experience only claimed on damage and sacrifice, does not reflect Japan as the harmer. Japan has been constructing nuclear power plants since 1954 in the same year when the 5th Fukuryumaru has exposed until the meltdown of Fukushima Nuclear Plant although took place of nuclear radiation exposures of Three Mile and Chernobyl. Due to the exploding of Fukushima Nuclear Power Plant, Japan reconsiders the danger of nuclear disaster. In conclusion, the purpose of this paper may be found that the sense of victim which flowed in contemporary art is able to inquire into the response of artist on the subject of nuclear as well as the relationship between society, politics, culture, and modern history of Japan and international political situation.

  • PDF

Assessment of Effective Dose from Diagnostic X-ray Examinations of Adult (진단X선에 의한 성인의 진단행위별 유효선량평가)

  • Kim, Woo-Ran;Lee, Choon-Sik;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.27 no.3
    • /
    • pp.155-164
    • /
    • 2002
  • Methodology to evaluate the effective doses to adults undergoing various diagnostic x-ray examinations were established by Monte Carlo simulation of the x-ray examinations. Anthropomorphic mathematical phantoms, the MIRD5 male phantom and the ORNL female phantom, were used as the target body and x-ray spectra were produced by the x-ray spectrum generation code SPEC78. The computational procedure was validated by comparing the resulting doses to the results of NRPB studies for the same diagnostic procedures. The effective doses as well as the organ doses due to chest, abdomen, head and spine examinations were calculated for x-rays incident from AP, PA, LLAT and RLAT directions. For instance, the effective doses from the most common procedures, chest PA and abdomen AP, were 0.029 mSv and 0.44 mSv, respectively. The fact that the effective dose from PA chest x-ray is far lower than the traditional value of 0.3 mSv(or 30 mrem), which results partly from the advances of technology in diagnostic radiology and partly from the differences in the dose concept employed, emphasizes necessities of intensive assessment of the patient doses in wide ranges of medical exposures. The methodology and tools established in this study can easily be applied to dose assessments for other radiology procedures; dose from CT examinations, dose to the fetus due to examinations of pregnant women, dose from pediatric radiology.

An External Costs Assessment of the Impacts on Human Health from Nuclear Power Plants in Korea (국내원전운전(國內原電運轉)에 따른 보건영향(保健影響)의 외부비용평가(外部費用評價))

  • Kim, Kyoung-Pyo;Kang, Hee-Jung
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.2
    • /
    • pp.67-76
    • /
    • 2008
  • As the first comprehensive attempt at a national implementation, this study aims at assessing the external costs of major electricity generation technologies in Korea, particularly an evaluation of the impacts on human health resulting from exposures to atmospheric radiological emissions from nuclear power plants, and a monetary quantification of their damages. The methodology used for the assessment of the externalities of the selected fuel cycles has been developed by the International Atomic Energy Agency (IAEA), namely the SimPacts Model Package. The model is internationally recognized as a tool which can be applied to a wide range of fuels, different technologies and locations, for an externalities study. In this study, the relevant emissions are quantified first and then their impacts on human health are evaluated and compared. The study focused on all the nuclear power plants for the last 6 years ($2001{\sim}2006$) in Korea. With respect to nuclear power, the impact analysis only focuses on a power generation, however the front- and back-end nuclear fuel cycles are not included, namely uranium mining, conversion, enrichment, reprocessing, conditioning, etc., because these facilities are not present in Korea. The analysis results show that nuclear power in general, generates low external costs. The highest damage costs from the nuclear power plants among the 4 sites in Korea were estimated to be 3.9 mills/MWh, which is about 1/20th of the result for a similar case study conducted in the U.K., implemented through the ExternE project. This difference is largely due to the number of radionuclides included in the study and the amount of released radioactive emissions based on up-to-date information in Korea. In this study, the sensitivities of the major factors for nuclear power plants were also calculated. The analysis indicates that there was around a ${\pm}3%$ damage costs variation to a ${\pm}15%$ change of the reference population density and a ${\pm}1%$ damage cost variation to a $1{\sim}30$ meters change of the effective release height, respectively. These sensitive calculations show that there is only a minor difference when the reference costs are compared.