• Title/Summary/Keyword: Radiation exposure management

Search Result 233, Processing Time 0.021 seconds

The Expression changes of AMPK, ERK-1/2, and p38 protein associated with Exercise in the Mouse hippocampus exposed to Radiofrequency Radiation (전자파(電磁波)에 노출된 생쥐의 해마에서 운동이 AMPK, ERK-1/2, p38 단백 발현 변화에 미치는 생체 영향)

  • Lee, Min-Sun;Park, Oak Jin;Kim, Hyun Taeg;Kim, Myeung Ju
    • Journal of Digital Convergence
    • /
    • v.18 no.3
    • /
    • pp.267-273
    • /
    • 2020
  • To determine the biological effects of exercise on hippocampus in mice brain exposed to radiofrequency radiaton (RF), the expression of AMPKα, p-AMPKα, ERK1/2, p-ERK1/2, p38, and p-p38 protein in the mouse exposed to RF were investigated in the hippocampal tissues, Western blot method was used to compare the protein expression levels for each molecule. Significant increases in protein expression of individual and phosphorylated molecules were observed in the spontaneous exercise group, and the expression of these molecules was notably decreased in the RF exposure and spontaneous exercise group. This study shows that neuroplasticity can be increased by exercise in hippocampus that is responsible for memory, but memory and cognitive function may be affected by exposure to RF. We may expect clinically interesting results on dementia or Alzheimer disease if we proceed further investigation on the effect of RF.

Development of Simple and Rapid Radioactivity Analysis for Thorium Series in the Products Containing Naturally Occurring Radioactive Materials (NORM) (천연방사성물질(NORM)을 함유한 가공제품 내 토륨계열 방사능 평가를 위한 간단/신속 분석법 개발)

  • Yoo, Jaeryong;Park, Seyoung;Yoon, Seokwon;Ha, Wi-Ho;Lee, Jaekook;Kim, Kwang Pyo
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.1
    • /
    • pp.71-79
    • /
    • 2016
  • Background: It is necessary to analyze radioactivity of naturally occurring radioactive materials (NORM) in products to ensure radiological safety required by Natural Radiation Safety Management Act. The pretreatments for the existing analysis methods require high technology and time. Such destructive pretreatments including grinding and dissolution of samples make impossible to reuse products. We developed a rapid and simple procedure of radioactivity analysis for thorium series in the products containing NORM. Materials and Methods: The developed method requires non-destructive or minimized pretreatment. Radioactivity of the product without pretreatment is initially measured using gamma spectroscopy and then the measured radioactivity is adjusted by considering material composition, mass density, and geometrical shape of the product. The radioactivity adjustment can be made using scaling factors, which is derived by radiation transport Monte Carlo simulation. Necklace, bracelet, male health care product, and tile for health mat were selected as representative products for this study. The products are commonly used by the public and directly contacted with human body and thus resulting in high radiation exposure to the user. Results and Discussion: The scaling factors were derived using MCNPX code and the values ranged from 0.31 to 0.47. If radioactivity of the products is measured without pretreatment, the thorium series may be overestimated by up to 2.8 times. If scaling factors are applied, the difference in radioactivity estimates are reduced to 3-24%. Conclusion : The developed procedure in this study can be used for other products with various materials and shapes and thus ensuring radiological safety.

Sequence and Time Interval in Combination of Irradiation and Cis-Diamminedichloroplatinum in C3H Mouse Fibrosarcoma (C3H 마우스 섬유육종에 있어서 방사선 조사와 Cis-diamminedichloroplatinum의 병용시 순서 및 시간간격의 영향)

  • Ha, Sung-Whan;Choi, Eun-Kyung;Park, Charn-Il
    • Radiation Oncology Journal
    • /
    • v.11 no.1
    • /
    • pp.29-34
    • /
    • 1993
  • Experiments have been carried out with C3H mouse fibrosarcoma (FSa II) to determine the effect of different sequence and time intervals between irradiation and administration of cis-diammihedichloroplatinum (cis-DDP) with gross tumors (6 mm in diameter), microscopic tumors (3 days after transplantation of $10^3$ cells) and cells in culture. The drug was administered either 24, 12, 8, 4, 2, 1, 0.5 hour before irradiation, immediately before irradiation, or 0.5, 1, 2, 4, 8, 12, 24 hours after irradiation. In case of in vivo studies, tumor growth delay was used as an end point. Clonogenic cell surviving fraction was used for in vitro studies. Tumor growth delay for gross tumor after 10 Gy radiation plus 10 mg/kg cis-DDP ranged from 6.3 to 10.66 days and the enhancement ratio ranged from 1.37 to 2.23. The most effective combination was when cis-DDP was given 4 hours before irradiation. Tumor growth delay for microscopic tumor after 5 Gy of radiation and 5 mg/kg of cis-DDP ranged from 3.55 to 11.98 days with enhancement ratio from 2.05 to 6.92. Microscopic tumors showed response significantly greater than additive in every time interval and the most effective treatments were when cis-DDP was given 2 and 1 hour before irradiation. In in vitro experiment, the surviving fraction after 6 Gy of radiation and 1 hour exposure to 4 ${\mu}M$ cis-DDP fluctuated as a function of time between treatments, but the difference between maximum and minimum surviving fractions was very small. According to the above results the sequence and time interval between irradiation and chemotherapy is very critical especially for the management of microscopic tumors as in the case of postoperative adjuvant treatment.

  • PDF

Functional outcome predictors following mandibular reconstruction with osteocutaneous fibula free flaps: correlating early postoperative videofluoroscopic swallow studies with long-term clinical results

  • Gonzalez, Santiago R.;Hobbs, Bradley;Vural, Emre;Moreno, Mauricio A.
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.41
    • /
    • pp.30.1-30.8
    • /
    • 2019
  • Background: Advancements in the field of microvascular surgery and the widespread adoption of microvascular surgical techniques have made the use of osteocutaneous fibula free flaps the standard of care in the surgical management of segmental mandibular defects. Although the literature possesses abundant evidence to support the effectiveness of fibula free flaps as a reconstructive method, there are relatively few studies reporting on outcomes as objectively measured by videofluoroscopic swallowing studies (VFSS). The purpose of this study is to explore the potential correlation between early postoperative VFSS and the long-term swallowing outcomes in patients who underwent mandibular reconstruction with fibula free flaps. Methods: We performed a retrospective chart review of 36 patients who underwent mandibular reconstruction with osteocutaneous fibular free flaps between 2009 and 2012. Demographics, clinical variables, VFSS data, and diet information were retrieved. Penetration and aspiration findings on VFSS, long-term oral feeding ability, and the need for gastrostomy tube were statistical endpoints correlated with postoperative clinical outcomes. Results: Thirty-six patients were reviewed (15 females and 21 males) with a mean age of 54 years (7-81). Seventeen cases were treated for malignancy. The size of the bony defect ranged from 3 to 15 cm (mean = 9 cm). The cutaneous paddle, a surrogate for soft tissue defect, ranged from 10 to 125 ㎠ (mean = 52 ㎠). A gastrostomy tube was present in patients preoperatively (n = 8), and postoperatively (n = 14). Seventeen patients had neoadjuvant exposure to radiation. Postoperative VFSS showed penetration in 13 cases (36%) and aspiration in seven (19%). Overall, 29 patients (80.6%) achieved unrestricted diet, and this was statistically correlated with age (p = 0.037), radiation therapy (p = 0.002), and preoperative gastrostomy tube (p = 0.03). The presence of penetration or aspiration on VFSS was a strong predictor for long-term unrestricted oral diet (p < 0.001). Conclusion: Early postoperative VFSS is an excellent predictor for long-term swallowing outcomes in patients undergoing mandibular reconstruction with osteocutaneous fibula free flaps.

Comparison on the Dosimetry of TLD and PLD by Dose Area Product (DAP(Dose Area Product)를 이용한 TLD와 PLD의 선량 측정 비교)

  • Choi, Jae-Ho;Kang, Gu-Jun;Chang, Seo-Goo
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.3
    • /
    • pp.244-250
    • /
    • 2012
  • The results of analyzing the difference between performances of individual dosimeters on this research subjecting the PLD and TLD, which are the official personal dosimeters, through dosimetry are as follows. After scanning the integral dose using an automatic scanner, the values of two devices that went through dose adjustment process had a statistical difference in TLD and PLD measurements under each filming conditions which were 70kVp, 200mA, 0.012sec and 42kVp, 100mA, and 0.012sec (p<0.001 and p<0.001 respectively). As for the difference of measurement value between DAP and the two particles under 70kVp, 200mA, 0.012sec filming condition, TLD had a value lower than DAP average value by $44.2mGy{\cdot}cm^2$ and PLD had a value of $246.8mGy{\cdot}cm^2$ which was lower than DAP average value by $15.5mGy{\cdot}cm^2$, while under 42kVp, 100mA, 0.012sec filming condition, TLD had a value lower than DAP average value by $17.9mGy{\cdot}cm^2$ and PLD had a value of $82.6mGy{\cdot}cm^2$ which was lower than DAP average value by 7.6$mGy{\cdot}cm^2$. Also, compared to PLD, each of 10 devices measured dose value in TLD had a larger deviation between the particles, and for a reproducibility test which repeatedly measured one particle, PLD had ${\pm}1%$ which was lower than TLD's ${\pm}2%$. As such, PLD had a superior performance result in dose measurement capacities aspect compared to TLD, and therefore we could verify that PLD is more appropriate and advantageous in managing radiation-related task performing worker's personal radiation exposure management in the diagnostic radiation field.

An Effective Block of Radioactive Gases for the Storage During the Synthesis of Radiopharmaceutical (방사성의약품 합성에서 발생하는 방사성기체의 효율적 차단)

  • Chi, Yong Gi;Kim, Dong Il;Kim, Si Hwal;Won, Moon Hee;Choe, Seong-Uk;Choi, Choon Ki;Seok, Jae Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.126-130
    • /
    • 2012
  • Purpose : Methode an effective block was investigated to deal with volatile radioactive gas, short lived radioactive waste generated as a result of the routinely produced radiopharmaceuticals FDG (2-deoxy-2-[$^{18}F$]fluoro-D-glucose) and compound with $^{11}C$. Materials and Methods : All components of the radiation stack monitoring and data management system for continuous radioactive gas detection in the air extract system purchase from fixed noble gas monitor of Berthold company. TEDLAR gas sampling bags purchase from the Dongbanghitech company. TEDLAR gas sampling bags (volume: 10 L) connected via paraflex or PTFE tubing and Teflon 3 way stopcock. When installing TEDLAR gas sampling bags in Hot cell on the inside and not radioactive gas concentrations were compared. According to whether the Hot cell inside a activated carbon filter installed, compare the difference in concentration of the radioactive gas $^{18}F$. Comparison of radiation emission concentration difference of module a FASTlab and TRACElab. Results : Activated carbon filter are installed in the Hot cell, a measure of the concentration of radioactive gas was 8 $Bq/m^3$. Without activated carbone filter in the hot cell was 300 $Bq/m^3$. Tedlar bag prior to installation of the radioactive gases a measure of the concentration was 3,500 $Bq/m^3$, $^{11}C$ synthesis of the measured concentration was 27,000 $Bq/m^3$. After installed a Tedlar bag and a measure concentration of the radioactive gases was 300 $Bq/m^3$ and $^{11}C$ synthesis was 1,000$Bq/m^3$. Conclusion : $^{11}C$ radioactive gas that was ejected out of the Hot cell, with the use of a Tedlar gas sampling bag stored inside. A compound of 11C is not absorbed onto activated carbon filter. But can block the release out by storing in a Tedlar gas sampling bag. We was able to reduce the radiation exposure of the worker by efficient radiation protection.

  • PDF

A Study on Segmentation Process of the K1 Reactor Vessel and Internals (K1 원자로 및 내부구조물 절단해체 공정에 대한 연구)

  • Hwang, Young Hwan;Hwang, Seokju;Hong, Sunghoon;Park, Kwang Soo;Kim, Nam-Kyun;Jung, Deok Woon;Kim, Cheon-Woo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.17 no.4
    • /
    • pp.437-445
    • /
    • 2019
  • After the permanent shutdown of K1 in 2017, decommissioning processes have attracted great attention. According to the current decommissioning roadmap, the dismantling of the activated components of K1 may start in 2026, following the removal of its spent fuel. Since the reactor vessel (RV) and reactor vessel internal (RVI) of K1 contain massive components and are relatively highly activated, their decommissioning process should be conducted carefully in terms of radiological and industrial safety. For achieving maximum efficiency of nuclear waste management processes for K1, we present activation analysis of the segmentation process and waste classification of the RV and RVI components of K1. For RVI, the active fuel regions and some parts of the upper and lower active regions are classified as intermediate-level waste (ILW), while other components are classified as low-level waste (LLW). Due to the RVI's complex structure and high activation, we suggest various underwater segmentation techniques which are expected to reduce radiation exposure and generate approximately nine ILW and nineteen very low level waste (VLLW)/LLW packages. For RV, the active fuel region and other components are classified as LLW, VLLW, and clearance waste (CW). In this case, we suggest in-situ remote segmentation in air, which is expected to generate approximately forty-two VLLW/LLW packages.

Evaluation and Experimental Production of Single-Phase Full-wave Rectification Type for X-ray Equipment of High Precision (고정밀도의 단상전파정류형 X선 장치의 제작 및 평가)

  • Han, Dong-Kyoon;Jung, Jae-Eun;Choi, Jun-Gu;Seoun, Youl-Hun;Ko, Shin-Gwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.1
    • /
    • pp.413-419
    • /
    • 2011
  • Diagnosis X-ray equipment localized at 1950's but it is developed suddenly at 1960's with demand together. Manufacture of Diagnostic X-ray equipment is controled by the KS regulation and the Ministry of Health and Welfare because of hazardous element etc. exposure by radiation. Most of diagnostic X-ray equipment ware single phase and three phase full-wave rectification but from 1980's it transforms it was exchanged in inverter type X-ray equipment. Inverter type X-ray equipment produces approximately 50~80% more average photon intensity then single phase full-wave rectification and the accuracy is high. But from a clinic it dose not use because expensive therefor the efficiency improvement of single phase full-wave rectification is necessary. We produced single phase full-wave rectification X-ray equipment control unit, high tension transformer, filament heating transformer, rectification circuit, high tension cable and others and evaluated efficiency, in result which is excellent compare with Rule of Safety Management and KS regulation.

Uncertainty Management on Human Intrusion Scenario Assessment of the Near Surface Disposal Facility for Low and Intermediate-Level Radioactive Waste: Comparative Analysis of RESRAD and GENII (중저준위방사성폐기물 표층처분시설의 인간침입 시나리오 평가에 대한 불확실성 관리: RESRAD와 GENII의 비교분석)

  • Kim, Minseong;Hong, Sung-Wook;Park, Jin Beak
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.15 no.4
    • /
    • pp.369-380
    • /
    • 2017
  • In order to manage the uncertainty about the evaluation and analysis of the human intrusion scenario of the Gyeongju Low and Intermediate Level Radioactive Waste(LILW) disposal facility, the calculation result by the GENII code was assessed using the RESRAD code, which was developed to evaluate the radiation effects of contaminated soil. The post-drilling scenario was selected as a human intrusion scenario into the near-surface disposal facility to analyze the uncertainty of the modeling by identifying any limitations in the simulation of each code and comparing the evaluation results under the same input data conditions. The results revealed a difference in the migration of some nuclides between the codes, but confirmed that the dose trends at the end of the post-closure control period were similar for all exposure pathways. Based on the results of the dose evaluation predicted by RESRAD, sensitivity analysis on the input factors was performed and major input factors were derived. The uncertainty of the modeling results and the input factors were analyzed and the reliability of the safety evaluation results was confirmed. The results of this study can be applied to the implementation 'Safety Case Program' for the Gyeongju LILW disposal facility.

Triathlon-Related Overuse Injury and Medical Issues (트라이애슬론의 과사용 부상과 의학적 위험요인에 대한 고찰)

  • Park, Chan-Ho;Kwak, Yi-Sub;Kim, Tae-Un
    • Journal of Life Science
    • /
    • v.20 no.2
    • /
    • pp.314-320
    • /
    • 2010
  • As the nature of triathlons is competition in three successive sports, triathletes experience elevated levels of stress on the body that are absent in single-sport athletic events, and consequently there are more potential medical problems to prepare for. Triathletes can also experience problems such as hypothermia, heat illness, excessive exposure to ultraviolet radiation, musculoskeletal injuries and trauma, immunosuppression, and haemolysis. Depending on the potentiality of such above-listed problems occurring in any given race, race organizers will prepare preventative measures and treatments accordingly. Olympic distance is not the only triathlon racing distance. Sprints, which are normally around half the Olympic distance, are common distances, as well as Long (2 km swim, 80 km bike, 20 km run), Ironman (3.8 km swim, 180 km bike, 42 km run), and ultra-distance events varying in length. Races of longer duration normally result in a higher percentage of athletes experiencing the above-mentioned medical problems, as well as inducing additional health risks such as hyponatraemia. Minimizing the occurrences of serious health issues is possible through the following means: carefully preparing for the probable race-day weather conditions; proper management and organization of the race; preparing an extensive water-safety and ground-course safety plan; distributing necessary nutrition along the course; and stressing the importance for athletes to have proper knowledge concerning race nutrition, biomechanical technique, physical preparation, and utilization of safe equipment. While risks of competing in triathlon are many, the instances of such medical problems are not excessive, and the triathlon has a reputation of being a reasonably safe sport as long as athletes with high risk take added precautions.