• Title/Summary/Keyword: Radiation emergency

Search Result 215, Processing Time 0.031 seconds

Radiation risk perception and its associated factors among residents living near nuclear power plants: A nationwide survey in Korea

  • Sung, Hyoju;Kim, Jung Un;Lee, Dalnim;Jin, Young Woo;Jo, Hyemi;Jun, Jae Kwan;Park, Sunhoo;Seo, Songwon
    • Nuclear Engineering and Technology
    • /
    • v.54 no.4
    • /
    • pp.1295-1300
    • /
    • 2022
  • There has been increased interest in researching risk perception of radiation to implement successful risk communication, particularly given the recent worldwide nuclear policy movement regarding nuclear energy. This study aimed to investigate characteristics of risk perception among residents living near normally operating nuclear power plants in South Korea by identifying factors associated with risk perception. A survey was conducted with face-to-face interviews for 1200 residents aged 20e84 years by gender- and age-stratified random sampling. Risk perception was associated with trust perception in nuclear safety, but was not highly correlated with benefit perception for utilizing nuclear power. Relatively high risk perception was observed in women, older age groups, and residents not having experience of nuclear-related education or work. This association remained after adjusting for other factors including benefit perception, trust perception, and psychological distress. In addition to these individual characteristics, risk perception was also associated with a residential district's own unique context, indicating that a strategy of risk communication should be developed differently for residents facing nuclear-related circumstances. Given that risk perception can be changed, depending on social values such as safety culture and economic setting, further studies are required to understand the changing characteristics of radiation risk perception.

Optimization of In-vivo Monitoring Program for Radiation Emergency Response

  • Ha, Wi-Ho;Kim, Jong Kyung
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.4
    • /
    • pp.333-338
    • /
    • 2016
  • Background: In case of radiation emergencies, internal exposure monitoring for the members of public will be required to confirm internal contamination of each individual. In-vivo monitoring technique using portable gamma spectrometer can be easily applied for internal exposure monitoring in the vicinity of the on-site area. Materials and Methods: In this study, minimum detectable doses (MDDs) for $^{134}Cs$, $^{137}Cs$, and $^{131}I$ were calculated adjusting minimum detectable activities (MDAs) from 50 to 1,000 Bq to find out the optimal in-vivo counting condition. DCAL software was used to derive retention fraction of Cs and I isotopes in the whole body and thyroid, respectively. A minimum detect-able level was determined to set committed effective dose of 0.1 mSv for emergency response. Results and Discussion: We found that MDDs at each MDA increased along with the elapsed time. 1,000 Bq for $^{134}Cs$ and $^{137}Cs$, and 100 Bq for $^{131}I$ were suggested as optimal MDAs to provide in-vivo monitoring service in case of radiation emergencies. Conclusion: In-vivo monitoring program for emergency response should be designed to achieve the optimal MDA suggested from the present work. We expect that a reduction of counting time compared with routine monitoring program can achieve the high throughput system in case of radiation emergencies.

Organ dose reconstruction for the radiation epidemiological study of Korean radiation workers: The first dose evaluation for the Korean Radiation Worker Study (KRWS)

  • Tae-Eun Kwon;Areum Jeong;Wi-Ho Ha;Dalnim Lee;Songwon Seo;Junik Cho;Euidam Kim;Yoonsun Chung;Sunhoo Park
    • Nuclear Engineering and Technology
    • /
    • v.55 no.2
    • /
    • pp.725-733
    • /
    • 2023
  • The Korea Institute of Radiological and Medical Sciences has started a radiation epidemiological study, titled "Korean Radiation Worker Study," to evaluate the health effects of occupational exposure to radiation. As a part of this study, we investigated the methodologies and results of reconstructing organ-specific absorbed doses based on personal dose equivalent, Hp(10), reported from 1984 to 2019 for 20,605 Korean radiation workers. For the organ dose reconstruction, representative exposure scenarios (i.e., radiation energy and exposure geometry) were first determined according to occupational groups, and dose coefficients for converting Hp(10) to organ absorbed doses were then appropriately taken based on the exposure scenarios. Individual annual doses and individual cumulative doses were reconstructed for 27 organs, and the highest values were observed in the thyroid doses (on average 0.77 mGy/y and 10.47 mGy, respectively). Mean values of individual cumulative absorbed doses for the red bone marrow, colon, and lungs were 7.83, 8.78, and 8.43 mSv, respectively. Most of the organ doses were maximum for industrial radiographers, followed by nuclear power plant workers, medical workers, and other facility workers. The organ dose database established in this study will be utilized for organ-specific risk estimation in the Korean Radiation Worker Study.

Advances in gamma radiation detection systems for emergency radiation monitoring

  • Kumar, K.A. Pradeep;Sundaram, G.A. Shanmugha;Sharma, B.K.;Venkatesh, S.;Thiruvengadathan, R.
    • Nuclear Engineering and Technology
    • /
    • v.52 no.10
    • /
    • pp.2151-2161
    • /
    • 2020
  • The study presents a review of research advancements in the field of gamma radiation detection systems for emergency radiation monitoring, particularly two major sub-systems namely (i) the radiation detector and (ii) the detection platform - air-borne and ground-based. The dynamics and functional characteristics of modern radiation detector active materials are summarized and discussed. The capabilities of both ground-based and aerial vehicle platforms employed in gamma radiation monitoring are deliberated in depth.

Radiation Protective Effect of Selenium and Folic Acid Mixtures in the Development of Congenital Anomalies Following Radiation Exposure to the Fetus of Perinatal Female White Rats (주산기 암컷 백서의 태아에 방사선피폭에 따른 선천성기형 발생 시 셀레늄과 엽산 혼합물의 방사선 방호효과)

  • Jung, Do-Young;Choi, Hyung-Seok;Kim, Jang-Oh;Shin, Ji-Hye;Kim, Joo-Hee;Park, Gyeong-Jin;Min, Byung-In
    • Journal of radiological science and technology
    • /
    • v.41 no.2
    • /
    • pp.157-162
    • /
    • 2018
  • This study is a search for radiation protection effects of radiation exposure on the organogenic period during the prenatal period, which is known to be the most likely to have congenital malformations by radiation exposure. To study the radiation protection for the mixture of selenium that is strong antioxidant and folic acid that is essential vitamin for DNA synthesis, 2 Gy of radiation was irradiated to pregnant female rats. then, after 14 days of fetal birth, observing blood components, SOD(Superoxide Dismutase), histological changes and external malformations. There was a significant protective effect to reduce blood cell damage(p<0.05) in the irradiation group after selenium and folic acid mixture were administered than irradiation group, and the activation of SOD which is antioxidant enzymes was increased. In addition, confirmed the effect of suppressing the expression of apoptosis of small intestinal cells and the reduction of cerebral cortex layer reduction by radiation. thus, it was confirmed that the congenital malformations were reduced as a result of these protective effects. Based on these results, selenium and folic acid mixture may reduce the incidence of congenital malformations, and it will reduce the damage of the fetus caused by the exposure of the organogenic period due to accidents.

Initial Management of Radiation Injuries

  • Linnemann Roger E.
    • Journal of Radiation Protection and Research
    • /
    • v.5 no.1
    • /
    • pp.11-25
    • /
    • 1980
  • The increasing utilization of radioactive isotopes in industry, medicine and research has raised the question, 'How should hospitals deal with radiation injuries when they occur?' A system for initial management of radiation injuries has been developed by Radiation Management Corporation. Radiation injuries are classified and a treatment plan outlined for each at the emergency and short term medical care phase. This system includes clinical prognosis as well as a detailed plan for quick set up or a Radiation Emergency Area in any hospital. Procedures for patient admission, preparation of the facility, general decontamination, sample taking, and wound decontamination are included.

  • PDF

Fingernail electron paramagnetic resonance dosimetry protocol for localized hand exposure accident

  • Jae Seok Kim;Byeong Ryong Park;Minsu Cho;Won Il Jang;Yong Kyun Kim
    • Nuclear Engineering and Technology
    • /
    • v.55 no.1
    • /
    • pp.270-277
    • /
    • 2023
  • Exposure to ionizing radiation induces free radicals in human nails. These free radicals generate a radiation-induced signal (RIS) in electron paramagnetic resonance (EPR) spectroscopy. Compared with the RIS of tooth enamel samples, that in human nails is more affected by moisture and heat, but has the advantages of being sensitive to radiation and easy to collect. The fingernail as a biological sample is applicable in retrospective dosimetry in cases of localized hand exposure accidents. In this study, the dosimetric characteristics of fingernails were analyzed in fingernail clippings collected from Korean donors. The dose response, fading of radiation-induced and mechanically induced signals, treatment method for evaluation of background signal, minimum detectable dose, and minimum detectable mass were investigated to propose a fingernail-EPR dosimetry protocol. In addition, to validate the practicality of the protocol, blind and field experiments were performed in the laboratory and a non-destructive testing facility. The relative biases in the dose assessment result of the blind and field experiments were 8.43% and 21.68% on average between the reference and reconstructed doses. The results of this study suggest that fingernail-EPR dosimetry can be a useful method for the application of retrospective dosimetry in cases of radiological accidents.

Personal Dosimeters Worn by Radiation Workers in Korea: Actual Condition and Consideration of Their Proper Application for Radiation Protection

  • Eunbi Noh;Dalnim Lee;Sunhoo Park;Songwon Seo
    • Journal of Radiation Protection and Research
    • /
    • v.48 no.3
    • /
    • pp.162-166
    • /
    • 2023
  • Background: Assessment of the radiation doses to which workers are exposed can differ depending on the placement of dosimeters on the body. In addition, it is affected by whether the placement is under or over a shielding apron. This study aimed to evaluate the actual positioning of personal dosimeters on the body, with or without shielding aprons, among radiation workers in Korea. Materials and Methods: We analyzed the survey data, which included demographic characteristics, such as sex, age, occupation, work history, and placement of the personal dosimeter being worn, from a cohort study of Korean radiation workers. We assessed the use of personal dosimeters among workers, stratified by sex, age, working period, starting year of work, and occupation. Results and Discussion: Overall, high compliance (89.1% to 99.0%) with the wearing of dosimeters on the chest was observed regardless of workers' characteristics, such as age, sex, occupation, and work history. However, the placement of dosimeters, either under or over the shielding aprons, was inconsistent. Overall, 40.1% of workers wore dosimeters under their aprons, while the others wore dosimeters over their aprons. This inconsistency indicates that radiation doses are possibly measured differently under the same exposure conditions solely owing to variations in the placement of worn dosimeters. Conclusion: Although a lack of uniformity in dosimeter placement when wearing a shielding apron may not cause serious harm in radiation dose management for workers, the development of detailed guidelines for dosimeter placement may improve the accuracy of dose assessment.

Assessment of Applicability of Portable HPGe Detector with In Situ Object Counting System based on Performance Evaluation of Thyroid Radiobioassays

  • Park, MinSeok;Kwon, Tae-Eun;Pak, Min Jung;Park, Se-Young;Ha, Wi-Ho;Jin, Young-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.42 no.2
    • /
    • pp.83-90
    • /
    • 2017
  • Background: Different cases exist in the measurement of thyroid radiobioassays owing to the individual characteristics of the subjects, especially the potential variation in the counting efficiency. An In situ Object Counting System (ISOCS) was developed to perform an efficiency calibration based on the Monte Carlo calculation, as an alternative to conventional calibration methods. The purpose of this study is to evaluate the applicability of ISOCS to thyroid radiobioassays by comparison with a conventional thyroid monitoring system. Materials and Methods: The efficiency calibration of a portable high-purity germanium (HPGe) detector was performed using ISOCS software. In contrast, the conventional efficiency calibration, which needed a radioactive material, was applied to a scintillator-based thyroid monitor. Four radioiodine samples that contained $^{125}I$ and $^{131}I$ in both aqueous solution and gel forms were measured to evaluate radioactivity in the thyroid. ANSI/HPS N13.30 performance criteria, which included the relative bias, relative precision, and root-mean-squared error, were applied to evaluate the performance of the measurement system. Results and Discussion: The portable HPGe detector could measure both radioiodines with ISOCS but the thyroid monitor could not measure $^{125}I$ because of the limited energy resolution of the NaI(Tl) scintillator. The $^{131}I$ results from both detectors agreed to within 5% with the certified results. Moreover, the $^{125}I$ results from the portable HPGe detector agreed to within 10% with the certified results. All measurement results complied with the ANSI/HPS N13.30 performance criteria. Conclusion: The results of the intercomparison program indicated the feasibility of applying ISOCS software to direct thyroid radiobioassays. The portable HPGe detector with ISOCS software can provide the convenience of efficiency calibration and higher energy resolution for identifying photopeaks, compared with a conventional thyroid monitor with a NaI(Tl) scintillator. The application of ISOCS software in a radiation emergency can improve the response in terms of internal contamination monitoring.

NOAA's Response Plan for Nuclear Emergencies

  • Hwang, Sun-Tae;Choi, Kil-Oung
    • Journal of Radiation Protection and Research
    • /
    • v.25 no.2
    • /
    • pp.115-118
    • /
    • 2000
  • With reference to nuclear emergency information concerning the national emergency plan for nuclear accidents, the response plan for the atmospheric nuclear emergencies of the U.S. National Oceanic and Atmospheric Administration (NOAA) was reviewed and described for introducing an overview on it to the Korean Association for Radiation Protection (KARP).

  • PDF