은나노입자의 방사성 동위원소 운반체 적용 유효성 검증 연구 (Feasibility Study on Silver Nanoparticle Application to a Radioisotope Carrier)

  • 장범수;이주상;박해준;김화정;박상현
    • 방사선산업학회지
    • /
    • 제5권3호
    • /
    • pp.197-202
    • /
    • 2011
  • In this study, an Ag-polyaniline-silica (Ag-PANI-silica) nanoparticle was evaluated as a radioisotope carrier. An Ag-PANI-silica nanoparticle was incubated in the $^{125}I$ solution for a duration of 24 hr to test its radioisotope absorptivity. During the incubation, radioactivity of the nanoparticle was measured at 3, 6, 12, and 24 hr. After a 24 hr incubation, $^{125}I$-Ag-PANI-silica nanoparticle was incubated in a fresh saline for a duration of 48 hr to check its stability. Additionally, the $^{125}I$-Ag-PANI-silica nanoparticle was injected to the ICR mouse to investigate its in-vivo distribution characteristics. The $^{125}I$ absorption yield of the Ag-PANI-silica nanoparticle was higher than 95% after a 6 hr incubation period in the $^{125}I$ solution. And $^{125}I$-Ag-PANI-silica was stable for 48 hr at 80% yield at room temperature. The SPECT/CT image of a mouse that received $^{125}I$-Ag-PANI-silica complex showed that the $^{125}I$-Ag-PANI-silica complex was distributed in the lung, stomach and thyroid at 30 min post injection. From these results, the Ag-PANI-silica nanoparticle has good radio-iodine carrying property and can be applicable for the purpose of diagnosis and therapy.

3차원 방사선 탐지장치용 검출센서의 차폐체 및 Collimator 구조 분석 연구 (The Analysis of the Collimator & Radiation Shield for the Radiation Sensor for the 3Dimension Radiation Detection)

  • 황영관;이남호;박성훈;정상훈;김종열;최명진
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2014년도 춘계학술대회
    • /
    • pp.707-709
    • /
    • 2014
  • 핵폭발이나 원자력 발전시설 사고와 같이 대규모 방사선사고 발생 시 주변지역은 감응방사선 또는 방사선 낙진으로 인해 오염된다. 이러한 오염지역을 원격에서 탐지하여 오염물질에 대한 분포 및 오염 정도를 확보한다면 오염물질 제거뿐만 아니라 오염에 대한 피해를 최소화 할 수 있다. 본 논문에서는 오염 물질을 탐지하기 위한 스테레오 검출기 개발의 일환으로 MCNP코드를 이용하여 검출기의 차폐체 및 콜리메이터를 설계하고 교정된 감마선 조사시설을 통해 일정한 선량의 감마선을 조사하여 차폐체 및 콜리메이터에 대한 영향을 분석하였다. 본 논문의 결과는 방사선 탐지를 위한 효율적인 검출기 구조를 설계를 위한 기초자료로 활용될 것이다.

  • PDF

Using RESRAD-BUILD for Potential Radiation Dose Estimation the Korea Research Reactor-1 When It Opens to the Public as a Memorial Hall

  • Lee, Sangbok;Yoon, Yongsu;Kim, Sungchul
    • International Journal of Contents
    • /
    • 제16권2호
    • /
    • pp.102-108
    • /
    • 2020
  • The purpose of this study was to estimate and analyze the potential radiation dose that the future visitors and the cleaning staff will be exposed to when the KRR-1 reactor is converted into a memorial hall. The radiation doses were estimated using the RESRAD-BUILD software, where case, building, receptor, shielding, and source parameters were applied as the input data. Also, the basic data for the assessment of the radiation doses were determined in an indirect manner using the data on the waste generated during the decommissioning process of the reactor. The assessment results indicate that the potential radiation dose to the visitors and the cleaning staff will be less than 1 mSv, the annual dose limit for the general public. However, if anyone for a significant period of time is close to the reactor, the overall dose will increase. The radiation dose for the future visitors and the cleaning staff was determined to be lower than the annual dose limit for the general public. Given such a risk, systematic measures, such as periodic monitoring or limiting hours, are imperative.

TRY 방법론에 의한 표준일사량데이터 평가 (Evaluation of Typical Solar Radiation Data by the TRY Methodology)

  • 유호천;이관호;김경률;박소희
    • KIEAE Journal
    • /
    • 제7권6호
    • /
    • pp.23-28
    • /
    • 2007
  • Limited fossil fuels and unstable energy supply are considered as one of the critical problems in architecture requiring large amounts of energy. In order to this challenge, environment-friendly architecture design is required. Clear data should be prepared to apply solar energy to architecture aggressively and properly. This study used FS statistical analysis data regarding average daily solar radiation of Seoul observed over 20 years to find out standard year and standard daily solar radiation. This study also aims to compare and evaluate an appropriate method of selecting a standard year which is too close to measurement value through comparison and analysis with daily solar radiation acquired by applying overseas researchers' suggesting weight factor. As a result, the data nearest to measurement value of daily solar radiation was UK CIBSE TRY(TYPE 2) displaying 0.100in t-statistic index. For UK CIBSE TRY(TYPE 2), weight factor was applied to three climatic elements except relative humidity. TYPE 1 and TYPE 3 recorded 0.343 and 0.367, respectively, showing higher record of t-statistic than TYPE 2. TYPE 1 was calculated through FS statistical value of single data about daily solar radiation with other climatic elements excluded. For TYPE 3, relative humidity was added to TYPE 2. In particular, since TYPE 2 was closer to the measurement value compared to the others, it is necessary to consider relationship with other climate elements if other climate elements are added.

전자선을 이용한 아크릴산 그라프트 케냐프 섬유의 제조 및 이를 이용한 케냐프 섬유보강 시멘트의 투수특성 평가 (Preparation of Acrylic Acid-grafted Kenaf Fibers Using E-beam Irradiation and Evaluation of Permeability of Kenaf Fiber-cement Composites)

  • 김두영;전준표;김현빈;오승환;강필현
    • 방사선산업학회지
    • /
    • 제8권1호
    • /
    • pp.53-57
    • /
    • 2014
  • The kenaf is quickly developing as a renewable resource. Kenaf can be grown under a wide range of weather conditions. Modification of kenaf fiber by graft polymerization provides a significant route to alter the chemical properties, including surface hydrophilicity or hydrophobicity. In this study, kenaf fiber surfaces were grafted with acrylic acid as a hydrophilic group using electron beam irradiation. The grafting rate increased with an increase in grafting time. The FT-IR results confirmed that acrylic acid was successfully grafted onto the kenaf fibers. The wettability of the kenaf fiber was increased, accompanied by acylic acid grafting on the fiber surface. According to the permeability test result, it was found that acrylic acid grafted kenaf fiber reinforced cement composite was more reduced than non-grafted kenaf fiber reinforced cement composite.

Ion Beam-based Surface Modification of Polyimide Films for Adhesion Improvement with Deposited Metal Layer

  • Cho, Hwang-Woo;Jung, Chan-Hee;Hwang, In-Tae;Choi, Jae-Hak;Nho, Young-Chang
    • 방사선산업학회지
    • /
    • 제4권4호
    • /
    • pp.335-339
    • /
    • 2010
  • In this study, the surface of polyimide (PI) films was modified using ion implantation to enhance its adhesion to a deposited copper (Cu) layer. The surfaces of the PI films were implanted with 150 keV $Xe^+$ ions at fluences varying from $1{\times}10^{14}$ to $1{\time}10^{16}ions\;cm^{-2}$. The Cu layers were then deposited on the implanted PI. The surface properties of the implanted PI film were investigated based on the contact angle measurements, Fourier transform infrared spectroscopy (FT-IR), X-ray photoelectron spectroscopy (XPS), and atomic force microscopy (AFM). Furthermore, the adhesive strength between the deposited Cu layer and PI film was estimated through a scratch test using a nanoindenter. As a result, the surface environment of the PI film was changed by the ion implantation, which could have a significant effect on the adhesion between the deposited Cu layer and the PI.

복사 차폐막이 설치된 극저온 용기의 열부하 특성에 관한 실험적 연구 (An Experimental Study on the Thermal Load of a Cryochamber with Radiation Shields)

  • 김영민;강병하;박성제
    • 설비공학논문집
    • /
    • 제20권1호
    • /
    • pp.11-16
    • /
    • 2008
  • Infrared (IR) detectors are widely used for such applications as thermoelastic stress analysis, medical diagnostics and temperature measurement. Infrared detectors commonly need to be refrigerated below 80 K, and thus a cooling system should be equipped together with the detector system. The cooling load, which should be removed by the cooling system to maintain the nominal operating temperature of the detector, critically depends on the insulation efficiency of the cryochamber housing the detector. Thermal load of a cryochamber is attributed to the conduction heat transfer through a cold finger, the gases conduction and radiation heat transfer. The thermal loads of an infrared detector cryochamber with a radiation shield are investigated experimentally in present study. Since the effect of radiation heat transfer on thermal loads is significant, radiation shields is installed in the cold finger part to protect heat input through radiation.

New methods for optical distance indicator and gantry angle quality control tests in medical linear accelerators: image processing by using a 3D phantom

  • Shandiz, Mahdi Heravian;Layen, Ghorban Safaeian;Anvari, Kazem;Khalilzadeh, Mohammadmahdi
    • Radiation Oncology Journal
    • /
    • 제33권1호
    • /
    • pp.42-49
    • /
    • 2015
  • Purpose: In order to keep the acceptable level of the radiation oncology linear accelerators, it is necessary to apply a reliable quality assurance (QA) program. Materials and Methods: The QA protocols, published by authoritative organizations, such as the American Association of Physicists in Medicine (AAPM), determine the quality control (QC) tests which should be performed on the medical linear accelerators and the threshold levels for each test. The purpose of this study is to increase the accuracy and precision of the selected QC tests in order to increase the quality of treatment and also increase the speed of the tests to convince the crowded centers to start a reliable QA program. A new method has been developed for two of the QC tests; optical distance indicator (ODI) QC test as a daily test and gantry angle QC test as a monthly test. This method uses an image processing approach utilizing the snapshots taken by the CCD camera to measure the source to surface distance (SSD) and gantry angle. Results: The new method of ODI QC test has an accuracy of 99.95% with a standard deviation of 0.061 cm and the new method for gantry angle QC has a precision of $0.43^{\circ}$. The automated proposed method which is used for both ODI and gantry angle QC tests, contains highly accurate and precise results which are objective and the human-caused errors have no effect on the results. Conclusion: The results show that they are in the acceptable range for both of the QC tests, according to AAPM task group 142.

CBCT와 panorama 촬영시 위치에 따른 선량 비교 (Comparison of Dose Depending on the Position when Shooting Panorama and CBCT)

  • 정천수;김종일
    • 한국방사선학회논문지
    • /
    • 제7권3호
    • /
    • pp.175-179
    • /
    • 2013
  • 파노라마와 CBCT 같은 회전하는 방사선 발생장치에서 방사선작업종사자와 보호자의 적절한 피폭 방어 대책을 알아보고자 위치에 따른 방사선 조사선량을 비교 분석하였다. 사용된 장치로는 파노라마 DP-90-P PAX-500(Vatech, Korea)와 CBCT DCT-90-P IMPLAGRAPHY Dental CT system (Vatech, Korea)을 사용하였다. 조사선량 측정기는 Ion chamber model 2026과 Reader기 20X5-60E를 사용하였다. 촬영조건은 임상에서 사용하는 인자와 동일하게 설정하였다. 실험결과 파노라마는 검사가 처음 시작하는 A지점이 81${\mu}R$ 으로 가장 높게 나왔고, 검사가 끝나는 D점이 53${\mu}R$ 으로 가장 낮게 나왔다. CBCT의 경우는 검사가 끝나는 D지점이 1,021${\mu}R$ 으로 가장 높게 나왔고, 검사가 시작하는 A지점이 809.67${\mu}R$ 으로 가장 높게 측정되었다. 부득이하게 보호자나 방사선작업종사자가 환자를 잡고 검사해야 할 경우에는 피폭선량이 가장 많은 지점을 피해서 X선관이 회전하기 시작하는 지점과 끝나는 지점의 가운데 위치해야 할 것이다. 그리고 장비의 특성상 기계의 반대편이며, 환자의 측면에서 지지하는 것보다 후방에서 지지하는 것이 가장 안전할 것이고, 적절한 방호기구를 착용해야 할 것이다.

국소적으로 진행된, 절제 불가능한 췌장암에서 정위 방사선 치료 (Locally Advanced, Unresectable Pancreatic Cancer Treated by Stereotactic Radiation Therapy)

  • 최철원;김미숙;조철구;류성렬;양광모;유형준;이동한;지영훈;한철주;김진;김영한
    • Radiation Oncology Journal
    • /
    • 제24권1호
    • /
    • pp.11-20
    • /
    • 2006
  • 목적: 국소적으로 진행된, 절제 불가능한 췌장암 치료에 있어 고식적 방사선 치료와 비교하여 Cyberknife(CK)를 이용한 정위 방사선 치료의 생존율 및 급성 독성에 대해 분석하고자 하였다. 대상 및 방법: 2003년 4월부터 2004년 4월까지의, Eastern Cooperative Oncology Group (ECOG) 활동도 3 이하이며 CT 및 PET/CT로 평가하여 원격 전이 없는 국소 진행된 췌장암 환자 19명을 대상으로 하였다 대상 환자는 점차 방사선량을 증가시키는 방법으로 33 Gy, 36 Gy, 39 Gy를 3분할로 각각 6명, 4명, 9명에서 CK를 이용한 정위 방사선 치료를 시행하였으며, 생존율 및 Radiation Therapeutic Oncology Group (RTOG) acute radiation morbidity criteria에 의한 위장관 독성을 분석하였다 또한 나이, 성별, ECOG 수행 점수, 항암 치료, 우회로 조성술(bypass surgery) 여부, 방사선량, CAl9-9, 계획용 표적 체적(planning target volume, PTV), CT상 주위 장기 및 혈관 침범 여부 등을 Log Rank test를 이용하여 예후 인자를 평가하였다. 결과: 본 연구에서 중앙 생존 기간은 11개월, 1년 생존율은 36.8%였다. 추적 조사 기간 중(범위 $3{\sim}20$개월, 중앙값 10개월) 유의한 위장관 급성 독성은 관찰되지 않았다 단일 인자 분석에서 계획용 표적 체적만이 유의한 예후 인자로 80cc 이하인 경우가 80cc 이상인 경우보다 생존율이 높았으며(p-value < 0.05), 나이, 성별, ECOG 수행 점수, 항암 치료, 우회로 조성술, CAl9-9 수치, 주위 장기 및 혈관 침범 여부 등에서는 통계적으로 유의한 차이를 보이지 않았다. 다인자 분석에서는 65세 이하인 경우와 PTV 80 co 이하인 경우에서 생존율이 높았다. 결론: 고식적 방사선 치료, 고선량 입체조형 방사선 치료(high dose conformal radiation therapy), 수술 중 방사선 치료(intraoperative radiation therapy) 또는 세기 조절 방사선 치료(Intensity modulated radiation therapy, IMRT)를 이용한 최근의 결과와 비교하여 CK를 이용한 정위 방사선 치료는 생존율 측면에서 비슷하거나 나은 결과를 보였다. 또한 심각한 부작용은 관찰되지 않았으며 짧은 기간의 치료로 환자에게 편의를 제공할 수 있어 결과적으로 삶의 질을 향상시킬 수 있을 것이다. 따라서, 이 새로운 치료 방법은 국소 진행된, 절제 불가능한 췌장암 환자에서 심각한 부작용 없는 효과적인 치료가 될 것으로 생각된다. 또한 계획용 표적 체적은 CK 치료의 유용한 예후 인자로 사용될 것이다.