• Title/Summary/Keyword: Radiation Test

Search Result 1,568, Processing Time 0.033 seconds

Factors Affecting Radiation Protection Behaviors among Operating Room Nurses (수술실 간호사의 방사선 방어행위의 영향 요인)

  • Kim, Jin;Kim, Jin Sun;Kim, Hyunlye
    • Korean Journal of Adult Nursing
    • /
    • v.28 no.6
    • /
    • pp.680-690
    • /
    • 2016
  • Purpose: This study was designed to identify knowledge, attitude, environment, and self-efficacy among perioperative nurses in terms of radiation protection and to describe those factors affecting radiation protection behaviors. Methods: The sample was comprised of 128 perioperative nurses who agreed to participate in this descriptive study. Data were collected from a self-administered questionnaire and were analyzed using the t-test, analysis of variance, Mann-whitney U test, Kruskal-Wallis test, Pearson's correlation, and multiple regression analyses. Results: Radiation protection behaviors were significantly different by participant's gender, length of career as a perioperative nurse, educational level and prior experience with radiation protection education. Radiation protection behaviors were significantly correlated with radiation protection environment and self-efficacy in terms of radiation protection behaviors. In the multiple linear regression models, radiation protection environment and self-efficacy on radiation protection behaviors were statistically significant predictors of radiation protection behaviors, which accounted for 50.3% of variance in dependent variable. Conclusion: This study concluded that radiation protective environment in operating room is important to promote radiation protective behaviors and radiation safety management program to enhance self-efficacy is highly recommended.

Effects of Radiation Safety Management Education with the Use of a Booklet for Intensive Care Unit Nurses (중환자실 간호사를 대상으로 소책자를 활용한 방사선 안전관리 교육의 효과)

  • Lee, Jeong Eun;Kim, Sang Hee
    • Journal of Korean Critical Care Nursing
    • /
    • v.10 no.2
    • /
    • pp.1-13
    • /
    • 2017
  • Purpose: This study investigated the effects that the use of a booklet for intensive care unit nurses had on radiation safety management education (knowledge about and behaviors in radiation safety management, and awareness of anxiety caused by radiation hazards). Methods: A randomized control group pretest-posttest design was used. A booklet about radiation safety management developed by the authors was used as educational material. Participants (N=42) were intensive care unit nurses of P hospital in B city. Training was provided to the experimental group (N=21). Knowledge about and behaviors in radiation safety management and awareness of anxiety caused by radiation hazards were measured by questionnaires before and after the intervention. Data was analyzed by an $X^2$-test, non-paired t-test, and paired t-test. Results: There was a significant difference between groups in knowledge of (t=-14.932, p<.001) and behaviors in (t=-8.297, p<.001) radiation safety management and awareness of anxiety caused by radiation hazards (t=9.378, p<.001). Conclusion: The levels of knowledge about and behaviors in radiation safety management and awareness of anxiety generated by radiation hazards of intensive care unit nurses increased after receiving one session of radiation safety management education using the booklet. Therefore, providing radiation safety management training is suggested as an effective strategy for improving radiation safety management.

  • PDF

The Radiation Safety Management in the Animal Hospital Using Inspection Standard of Diagnosis Radiation System (진단용 방사선발생장치의 검사기준을 적용한 동물병원의 방사선 안전관리)

  • Kim, Sang-Woo;Rhim, Jea-Dong;Han, Dong-Kyoon;Seoung, Youl-Hun
    • Journal of the Korea Safety Management & Science
    • /
    • v.12 no.4
    • /
    • pp.73-80
    • /
    • 2010
  • The purpose of this study was to investigate the actual conditions of radiation safety supervision in animal clinics using inspection standard of X-ray generator for diagnosis. The surveys for inspection standard system, equipment condition, and safety supervision were carried out in 18 animal clinics randomly. The inspection standard included reproducibility of dose exposure, kVp, mAs, collimator accuracy test, collimator luminance test, X-ray view box luminance test, grounding system equipment test and external leakage current test. The surveys of equipment condition and safety supervision used one-on-one interview with 5 points measurement. As a result, 44.44% of reproducibility of dose exposure was proper, 81.25% of kVp test was good, and 100% of mAs test was appropriate. Also, 66.66% of collimator accuracy test was proper, 61.11% of collimator luminance test was good, 53.13% of X-ray view box luminance test was suitable. In addition, only 5.55% of grounding system equipment and ground resistance was proper, 63.64% of external leakage current test was appropriate in grounding system equipment test. The 100mA electric capacity of X-ray generator for diagnosis was popular with 44.44%, and its 55.56% was purchased used equipment. Monthly average of less than 50 times (61.11%) was top frequency in use, and no animal clinic had a thermo-luminescence dosimeter(TLD). The 16 animal clinics with radiation safety zone and 2 without radiation safety zone were appeared.

Implementation of the Radiation Protection Module for Electronic Equipment from Pulsed Radiation and Its Function Tests (펄스방사선에 대한 전자장비 방호용 모듈구현 및 기능시험)

  • Lee, Nam-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.10
    • /
    • pp.1421-1424
    • /
    • 2013
  • The electronic equipment which is exposed to high level pulsed radiation is damaged by Upset, Latchup, and Burnout. Those damages come from the instantaneous photocurrent from electron-hole pairs generated in itself. Such damages appear as losses of a power in military weapon system or as a blackout in aerospace equipment and eventually caused in gross loss of national power. In this paper, we have implemented a RDC(Radiation detection and control module) as a part of the radiation protection technology of the electronic equipment or devices from the pulsed gamma radiation. The RDC, which is composed of pulsed gamma-ray detection sensor, signal processors, and pulse generator, is designed to protect the an important electronic circuits from the a pulse radiation. To verify the functionality of the RDC, LM118s, which had damaged by the pulse radiation, were tested. The test results showed that the test sample applied with the RDC was worked well in spite of the irradiation of a pulse radiation. Through the experiments we could confirm that the radiation protection technology implemented with the RDC had the functionality of radiation protection for the electronic devices.

AN INVESTIGATION INTO RADIATION LEVELS ASSOCIATED WITH DISMANTLING THE KOREA RESEARCH REACTOR

  • Choi, Geun-Sik;Kim, Hee-Reyoung;Han, Moon-Hee
    • Nuclear Engineering and Technology
    • /
    • v.42 no.4
    • /
    • pp.468-473
    • /
    • 2010
  • We confirmed that the dismantling of two research reactors with thermal power of $2MW_{th}$ and $100kW_{th}$, respectively, reveals no significant difference between the radiation levels of the research reactor site and the surrounding environment far away from it, from the radiation level aspect. Radiation dose and radioactivity were measured at monitoring points around the research reactor site of the Korea Atomic Energy Research Institute (KAERI) in Seoul and comparison points 0.5 km to 3.3 km from the site. To grasp trends in the radiation levels during dismantling from the end of 2002 to the end of 2007, the gamma radiation dose rate, the accumulated dose, and the radioactivity of the strontium, tritium, and gamma isotopes were statistically treated and estimated. The averages of these items between the two groups, the research reactor site and comparison points, were assessed by applying a T-test with a significance level of 0.05. P-values found by using the T-test were from 0.12 to 0.83 where the values were much higher than the significance level. As a result, no difference was observed between the radiation levels at the research reactor site and at the comparison points by this T-test. This study showed that dismantling activity of the Korea Research Reactor of the Seoul site did not expose the public or the environment to harmful levels of radiation.

The Public Impression of Radiation as a Product of Science Communication (방사선과 과학커뮤니케이션: 성공과 실패 -북한 핵실험 관련 사례분석-)

  • Kim, Hak-Soo;Oh, Mi-Young;Choi, Jinmyeung;Ha, Hyo-Suk
    • Journal of Radiation Industry
    • /
    • v.2 no.1
    • /
    • pp.35-42
    • /
    • 2008
  • The purpose of this study is to observe how the public impression of radiation is changing over the North Korea's nuclear bomb test. We found that the nuclear bomb test brought more negative impressions of radiation, but, in one year, more positive ones prevailed as in the pre-bomb-test. Those positive impressions were found to be composed of useful and positive elements mostly relative to health care. This suggests that we need to apply radiation (fusion) technology to solving everyday life problems in order to bring more positive impressions of radiation.

Experimental Analysis of Wheel Radiation Noise of HANVIT 200 Train in Curve Lines (곡선부에서의 한빛 200 열차 차륜방사 소음 특성)

  • Lee, Chan-Woo;Kim, Jae-Chul
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.907-910
    • /
    • 2008
  • The wheel radiation noise characteristic of Korean tilting train(Hanvit 200) on curved rail under the field test conditions is analyzed in this paper. The test railroad track was selected from Seodaejon to Songjeongri in Honam line. $5^{th}$ and $6^{th}$ car are decided to measure radiation noise level among a train of six cars. The test subject curve radius executed from R400, R500, R600, R700 and R800 segments. The speed of test trains when from R600 and R800 curves existing operation speed and speed up 20% of existing speed. On curved rail at the time of operation speed of Hanvit 200 trains from below 95km/h wheel radiation noise level at $94dBA{\sim}99dBA$, the operation speed from between $100km/h{\sim}144km/h$ wheel radiation noise level at $100dBA{\sim}106dBA$.

  • PDF

Changes in External Radiation Dose Rate for PET-CT Test Patients (PET-CT 검사 환자의 외부 방사선량률 변화)

  • Kim, Su-Jin;Han, Eun-Ok
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.2
    • /
    • pp.103-107
    • /
    • 2012
  • This paper analyzes changes in the external radiation dose rate of PET-CT test patients as a part of providing basic materials for reduction of radiation exposure to PET-CT test patients. In theory the measurement of external radiation dose rate of PET-CT test patients shows that the further the distance from the patient injected with radioactive pharmaceutical and a longer time elapsement from the injection leads to a smaller amount of radiation. Particularly, the amount of radiation marked the highest in the chest was at 4.17 minutes immediately after the intravenous injection and in the head after 77.47 minutes after urination in advance to the PET-CT test. As in the generalized information, it is desired to keep distance between the patient and caretakers or professionals to reduce the amount of radiation exposure from PET-CT test patients and to resume contact the patient after the time when the radiation has reduced. If contact is unavoidable, it is desired to keep at least 200cm from the patient. In addition, the amount of radiation reached the highest in the chest at first and then in the head from 77 minutes after injection. Accordingly, it would be helpful in achieving the optimization if contact is made based on the patient's physical characteristics. This study is significant as it measures changes in radiation the dose rate by; distance from the PET-CT test patient, time elapsed, and specific parts of body. Further studies based on the findings in this paper are required to analyze changes in radiation dose rate in accordance with individual characteristics unique to PET-CT patients and to utilize the results to reduce the amount of radiation patient, caretakers and professions are exposed.

Perceptions and attitudes of dental hygienists toward radiation safety and protection in the Republic of Korea

  • Yun, Kwidug;Lee, Kyung-Min;An, Seo-Young;Yoon, Suk-Ja;Jeong, Ho-Gul;Lee, Jae-Seo
    • International Journal of Oral Biology
    • /
    • v.46 no.4
    • /
    • pp.168-175
    • /
    • 2021
  • To investigate the perceptions and attitudes of dental hygienists toward radiation safety management in Korea. A total of 800 dental hygienists were randomly selected for an anonymous survey, and 203 of them participated. The questionnaire items included the following: sex, career period, type of installed radiographic equipment, recognition of the diagnostic reference level (DRL), participation in radiation safety education, and attitudes toward radiation protection for both patients and dental hygienists. The participants were divided into two groups according to their years of experience (< 10 years versus ≥ 10 years). The difference between the groups was investigated according to frequency distribution. Fisher's exact test or Pearson's chi-square (𝛘2) test was used as appropriate. A regression analysis was performed to investigate the impact of wearing a thyroid collar for personnel protection during patient radiation exposure. The types of installed radiographic equipment included panoramic radiography (96.1%), cephalometric radiography (76.9%), intraoral radiography (72.9%), and cone-beam computed tomography (69.5%). Significant differences were observed in the learning pathway for the DRL (Fisher's exact test, p < 0.05), satisfaction with radiation safety education (Pearson's 𝛘2 test = 5.3975, Pr = 0.02), and use of personnel radiation monitoring systems (Pearson's 𝛘2 test = 18.1233, Pr = 0.000) between the groups. Significant differences were also observed in personnel protection using a thyroid collar and patient protection during panoramic radiography (odds ratio = 14.2). Dental hygienists with more than 10 years of experience were more satisfied with radiation safety education and more interested in radiation monitoring. Considering career experience, customized, continuous, and effective radiation safety management education should be provided.

Development of A Multipurpose Passive Type Radon Monitor (다목적 수동형 라돈농도 측정기 개발)

  • Lee, Bong-Jae;Park, Yeong-Ung
    • Radioisotope journal
    • /
    • v.21 no.4
    • /
    • pp.55-65
    • /
    • 2006
  • A passive type radon monitor adopting two silicon PIN detector as radiation detector has been developed, manufactured and test-evaluated. A radiation signal processing circuit has been electronically tested and then the radiation detection characteristics of this instrument has been performance-tested by using reference radon concentration and a reference photon radiation field. As a result, in a electronic performance test, radiation signals from each detector were well observed in each signal processing circuit. The radiation detection sensitivity of this instrument after several test-irradiations to a Cs-137 gamma radiation source and a standard radon concentration appeared to be 1.37 cph/$\mu$Svh-1 and 1.66 pCi/L respectively. The developed radon monitor in this paper could be used conveniently in monitoring of radon concentration in buildings which population utilize in Korea.

  • PDF