• Title/Summary/Keyword: Radiation Shielding

검색결과 613건 처리시간 0.023초

Determination of X-ray and gamma-ray shielding capabilities of recycled glass derived from deteriorated silica gel

  • P. Sopapan;O. Jaiboon;R. Laopaiboon;C. Yenchai;C. Sriwunkum;S. Issarapanacheewin;T. Akharawutchayanon;K. Yubonmhat
    • Nuclear Engineering and Technology
    • /
    • 제55권9호
    • /
    • pp.3441-3449
    • /
    • 2023
  • We determined the radiation shielding properties for 10CaO-xPbO-(90-x) deteriorated silica gel (DSG) glass system (x = 20, 25, 30, 35, 40, and 45 mol.%). The mass attenuation coefficient (MAC) has been estimated at photon energies of 74.23, 97.12, 122, 662, 1173, and 1332 keV using a narrow beam X-ray attenuation and transmission experiment, the XCOM program, and a PHITS simulation. The obtained MAC values were applied to estimate the half value layer (HVL), mean free path (MFP), effective atomic number, and effective electron density. Results show that the MAC value of the studied glasses ranges between 0.0549 and 1.4415 cm2/g, increases with the amount of PbO, and decreases with increasing photon energy. The HVL and MFP values decrease with increasing PbO content and increase with increasing photon energy. The recycled glass, with the addition of PbO content (20-45 mol.%), exhibited excellent radiation shielding capabilities compared to standard barite and ferrite concretes and some glass systems. Moreover, the experimental radiation shielding parameters agree with the XCOM and PHITS values. This study suggests that this new waste-recycled glass is an effective and cost-saving candidate for X-ray and gamma-ray shielding applications.

친환경 소재의 의료 방사선 차폐 시트 개발; II: 바륨, 토르말린의 실리콘 폴리머 차폐 시트의 성능 평가 (Development of Radiation Shielding Sheet with Environmentally-Friendly Materials; II: Evaluation of Barum, Tourmaline, Silicon Polymers in the Radiation Shielding Sheet)

  • 김선칠;박명환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제34권2호
    • /
    • pp.141-147
    • /
    • 2011
  • 의료방사선 차폐체로 납과 같은 차폐효과를 가지는 동시에, 납과 동일한 경제성과 가공성을 지니고 있어 의료방사선 방어복인 에이프런(Apron)을 제작할 수 있는 납 대체물질을 시트형태로 개발하고자 연구하였다. 이는 의료 환경에 친환경 방사선 차폐시트로 제작하여 1차 실험과 동일한 조건에서 황산바륨의 충전률을 높이고 제작 시트의 유연성을 확보하기 위해 토르말린(Tourmaline)을 실리콘 폴리머에 첨가하여 차폐율과 시트의 가공성을 높이고자 하였다. 실험결과 저에너지에서는 5 mm에서 고에너지에서는 7 mm에서 실용적인 차폐효과가 있었으며, 황산바륨만을 충전했을 때보다는 제작시트의 유연성과 충전률이 다소 높은 결과를 얻을 수 있었으나, 독립적인 방사선 차폐효과의 토르말린 효과는 크지 않아 차폐율의 큰 변화는 기대할 수 없었다. 다만, 향후 차폐 시트 제작의 혼합과정의 재현성과 황산바륨의 혼합과 분산과정의 충전율과 공극률을 정량적으로 평가할 수 있는 연구가 지속되어야 할 것으로 사료된다.

한국인 임산부의 흉부 후-전 방향 방사선검사 시 적절한 차폐막 높이 (Optimal Height of Shielding Plate of Radiation in Posteroanterior Chest Radiography for Pregnant Women on Korea)

  • 주영철;김규형
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권2호
    • /
    • pp.97-102
    • /
    • 2018
  • The purpose of this study is to provide the basic data for reducing unnecessary radiation dose to the abdomen and fetus of pregnant women by presenting proper height of shielding protector for efficient abdominal shielding in chest PA examination of Korean pregnant women. The subjects of this study were 288 persons who were eligible for this study among 798 pregnant women who had chest PA examination from January 1, 2015 to December 31, 2016 Retrospective study was performed. Measurements was performed from the apex of the right and left lungs to costophrenic angle of the right and left lungs and to the lowest costophrenic angle among the right and left lungs at the top of the image(this line called Joo's line in this study). The mean of the right and left lung height of pregnant women were 259.09 mm and 263.57 mm, respectively. Also, the average height of the Joo's line designed by the researcher for proper abdominal radiation protection was 322.15 mm. For proper and efficient abdominal radiation protection for pregnant women, it is necessary to adjust the shielding according to the height of the pregnant woman. It is appropriate that the height of the shielding protector should be adjusted so that the upper part of the shield is located at 342.30 mm below from upper part of the detector.

일반영상 검사 시 몬테칼로 시뮬레이션을 이용한 3D 프린팅 차폐기구의 효용성 평가 (Evaluation of the Effectiveness of 3D Printing Shielding Devices using Monte Carlo Simulation in Plain Radiography)

  • 조용인;김정훈
    • 한국방사선학회논문지
    • /
    • 제14권3호
    • /
    • pp.303-311
    • /
    • 2020
  • 일반영상 검사 시 발생되는 산란선은 검사목적 부위 외 다른 장기 및 조직에 대해 2차적인 피폭을 유발할 수 있다. 현재 방사선 피폭을 저감하기 위해 사용되는 차폐기구는 종사자들의 방사선 방호 목적으로 대부분 사용되며, 환자의 방사선 방호는 거의 이뤄지지 않고 있다. 이에 본 연구에서는 모의실험을 통해 일반 영상 검사 시 산란선에 의한 장기 선량과 3D 프린팅 재료를 통한 방사선 차폐기구로의 효용성을 평가하고자 한다. 그 결과, 검사 시 장기별 흡수선량은 선원과의 거리가 인접하고, 피부표면에 근접한 장기일수록 2차 산란선에 의해 높은 영향을 나타내었다. 이를 방호하기 위한 3D 프린팅 차폐기구 사용에 따른 선량감소효과는 플라스틱 계열에 비해 혼합 프린팅 재료의 경우 더 높은 차폐효과를 나타내었다.

CANDU 사용후핵연료 수송용기 방사선차폐 영향평가 (Radiation Shielding Analysis of CANDU Spent Fuel Transport Cask)

  • 최종락;윤정현;강희영;이흥영;정성환
    • Journal of Radiation Protection and Research
    • /
    • 제18권2호
    • /
    • pp.27-35
    • /
    • 1993
  • 중수로형 원자로에서 방출되는 사용후핵연료 다발을 안전하게 운반할 목적으로 CANDU 수송용기에 대한 방사선차폐해석을 수행하였다. 핵연료의 연소도는 7,800MWD/MTU, 냉각기간은 5년으로 하여 ORIGEN2 코드로 방사선원을 구하고 이것으로 핵연료 378다발을 운반할 수 있는 수송용기의 차폐체 두께변화에 따른 선량을 영향을 비교하였다. 계산은 ANISN과 DOT4.2 코드를 사용하였으며, 해석결과 최적의 차폐구조를 선정 하였으며, 또한 IAEA 및 국내 원자력법의 수송법규에 명시된 정상수송 및 가상사고조건에 따른 차폐해석을 수행하여 CANDU 수송용기의 안전성을 입증하였다.

  • PDF

Effect of rare earth dopants on the radiation shielding properties of barium tellurite glasses

  • Vani, P.;Vinitha, G.;Sayyed, M.I.;AlShammari, Maha M.;Manikandan, N.
    • Nuclear Engineering and Technology
    • /
    • 제53권12호
    • /
    • pp.4106-4113
    • /
    • 2021
  • Rare earth doped barium tellurite glasses were synthesised and explored for their radiation shielding applications. All the samples showed good thermal stability with values varying between 101 ℃ and 135 ℃ based on dopants. Structural properties showed the dominance of matrix elements compared to rare earth dopants in forming the bridging and non-bridging atoms in the network. Bandgap values varied between 3.30 and 4.05 eV which was found to be monotonic with respective rare earth dopants indicating their modification effect in the network. Various radiation shielding parameters like linear attenuation coefficient, mean free path and half value layer were calculated and each showed the effect of doping. For all samples, LAC values decreased with increase in energy and is attributed to photoelectric mechanism. Thulium doped glasses showed the highest value of 1.18 cm-1 at 0.245 MeV for 2 mol.% doping, which decreased in the order of erbium, holmium and the base barium tellurite glass, while half value layer and mean free paths showed an opposite trend with least value for 2 mol.% thulium indicating that thulium doped samples are better attenuators compared to undoped and other rare earth doped samples. Studies indicate an increased level of thulium doping in barium tellurite glasses can lead to efficient shielding materials for high energy radiation.

고선량율 근접치료기의 선원교정과 치료실주변 방사선량 측정 (Calibration and Radiation Survey of High Dose Rate Remote Afterloading System)

  • 이정옥;강정구;문성록
    • Radiation Oncology Journal
    • /
    • 제13권1호
    • /
    • pp.101-104
    • /
    • 1995
  • High Dose Rate Remote Afterloading system was installed at Wonkwang University Hospital in January 1994. In this report, the calibration of a Gammamed 12-i High Dose Rate Remote Afterloading system and the radiation survey around the facility after design and construct a shieding room are discussed. The radiation survey of the facility indicates that the use of ordinary concrete shielding of existing room will provide adequate shielding. Also, the methodologies for performing source calibration are presented.

  • PDF

방사선 치료시 생식선 차폐체 성능 평가를 위한 MOSFET 선량 측정 (MOSFET Dosimetry for Evaluation of Gonad Shielding during Radiotherapy)

  • 김휘영;최윤석;박소연;박양균;예성준
    • Journal of Radiation Protection and Research
    • /
    • 제36권1호
    • /
    • pp.23-27
    • /
    • 2011
  • 방사선 치료를 받는 환자의 생식선에 대한 피폭 선량을 최소화하기 위한 차폐체의 성능을 MOSFET 측정을 통해 평가하고자 서울대학교 병원 방사선 종양학과에서 4명의 남자 직장암 환자를 대상으로 2009 년 이후로 시행한 생식선 차폐체 선량 측정 결과를 이용하였다. 환자 치료는 Varian 21EX 선형가속기 (LINAC) 에서 방출되는 6 MV 와 15 MV 의 X.ray 를 이용하였다. 선형가속기의 조준기 (collimator) 등에 의한 산란선 (scattered ray) 뿐만 아니라 방사선조사영역(radiation field) 내의 치료부위로부터 산란되어 전달되는 산란선을 최소로 하기 위하여 3면이 모두 차폐될 수 있도록 차폐체는 상자 모양으로 제작되었다. 차폐체는 납으로 만든 $7.5\;cm\;{\times}\;9.5\;cm\;{\times}5.5\;cm$ 크기의 상자와 $9\;cm\;{\times}\;9.5\;cm\;{\times}\;1\;cm$ 크기의 덮개로 이루어져 있다. 차폐체의 성능 평가를 위한 선량 측정은 MOSFET 을 이용하였다. 생식선 차폐체를 이용한 경우 차폐체 안쪽의 피폭 선량이 바깥쪽에 비해 평균적으로 23.07% 로 감소하였다. 차폐체 안쪽에 전달된 선량은 평균 0.01 Gy (표준편차 0.004 Gy) 로 측정되었다. 차폐체의 성능은 환자들 별로 적게는 18.76%부터 많게는 38.20% 까지 차이를 보였으나 전달된 절대적 선량은 무정자증 (aspermia) 의 가능성이 있는 0.35 Gy 와, 불임을 초래할 수 있는 2.0 Gy 의 기준치 이하로서, 차폐체의 효과는 충분한 것으로 확인할 수 있다. MOSFET 측정 결과, 생식선 차폐체를 이용하여 환자 생식선에 피폭되는 선량을 효과적으로 감소시킬 수 있음을 확인하였다. 기존의 연구에서 TLD 를 이용한 측정과 비교하여 MOSFET 을 이용하였을 때 보다 실시간으로 정확하게 차폐체에 의한 생식선의 선량 감소 효과를 평가할 수 있음을 확인하였다.

이동형 X선 발생장치의 2차 방사선 차폐를 위한 선속조절기 개발 연구 (Development of Radiation Restrictor for Secondary Radiation Shielding of Mobile X-ray Generator)

  • 구본열;김가중
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권5호
    • /
    • pp.397-403
    • /
    • 2018
  • Mobile X-ray generators are used not in the radiation area but in open space, which causes the exposure of secondary radiation to the healthcare professionals, patients, guardians, etc., regardless of their intentions. This study aimed to investigate the shielding effect of the developed radiation restrictor to block the secondary radiation scattered during the use of mobile X-ray generator. Upon setting the condition of mobile X-ray generator with chest AP, spatial doses were measured by the existence of human equivalent phantom and radiation restrictor, and measured by the existences of phantom and radiation restrictor at the same length of 100 cm. Measurements were taken at intervals of 10 cm every $30^{\circ}$ from $-90^{\circ}$ (head direction) to $+90^{\circ}$ (body direction). Upon the study results, spatial doses in all direction were increased by 45% on average when using phantom in the same condition, however, they were decreased by 64% on average when using the developed radiation restrictor. The dose at 100 cm from the center of X-ray was $3.0{\pm}0.08{\mu}Gy$ without phantom and was increased by 40% with $4.2{\pm}0.08{\mu}Gy$ after phantom usage. The dose when using phantom and the developed radiation restrictor was $1.4{\pm}0.08{\mu}Gy$, which was decreased by 66% compared to the case without using them. Therefore, it is considered the scattered radiation can be shielded at 100-150 cm, the regulation of the distance between beds, effectively with the developed radiation restrictor when using mobile X-ray generators, which can lower the radiation exposure to the people nearby including healthcare professionals and patients.