• 제목/요약/키워드: Radiation Quality Factor

검색결과 161건 처리시간 0.029초

방사선 치료를 받는 자궁경부암 환자의 가족지지와 성격이 삶의 질에 미치는 영향 (A study on the relationship of family support and personality with quality of life in the Patients receiving radiotherapy for cervix cancer)

  • 노영희
    • 대한방사선치료학회지
    • /
    • 제8권1호
    • /
    • pp.149-159
    • /
    • 1996
  • This descriptive correlational study was undertaken in order to investigate the relationship of family support and personality with quality of life in patients receiving radiotherapy for cervix cancer and to provide basic data to help them improve a better quality of life. The subjects for this study Were 80 out-patients undergoing a radiation therapy at C university hospital in K-city, from April, 1992 to October, 1994. The data were obtained using a convenience sampling technique. The tools used for this study were Ro's quality of life scale, Kang's family support scale and Wallston & others health locus of control scale. The collected data were analyzed by the SAS program using percentage, mean, standard deviation, pearson's correlation coefficients. The result were as follows : 1. The total average score of the quality of life of the subjects was 138.95(minimum score 121-maximum score 164), item mean score(range 1-5) was 2.95. The total average score of the family support of the subjects was 32.55 (minimum score 16-maximum score 47), item mean score(range 1-5) was 2.95 The total average score of the health locus of control of the subjects was 37.00 (minimum score 24-maximum score 49), item mean score (range 1-6) was 3.36. 2 The results of the analysis of the relationship between the quality of life scale and the health locus of control were as follows : the total average score in the quality of life of internal locus of control scale was 136.97, the total average score in the quality of life of external locus of control scale was 144.90. 3. There was a significant positive correlation between the health locus of control and the quality of life(r = 0.2927, p<0.01). The result of the analysis of the relationship between the each factor in the quality of life and health locus of control were as follows : There were significant differences between the health locus of control and emotional state factor(r=0.1514, p<0.01), economic life factor(r=0.2560, p<0.05), self-esteem factor(r=0.2289, p<0.05), physical state and function factor(r=0.1455, p<0.05), relationship with neighbors factor(r=0.0754, p<0.05), relationship with family factor (r=0.3324, p<0.01). 4. There was a significant positive correlation between the family support and the quality of life(r=0.459, p<0.001). The result of the analysis of the relationship between the each factor in the quality of life and family support were as follows : there were significant differences between family support and emotional state factor (r=0.3891, p<0.01), self-esteem factor(r=0.2661, p<0.05), relationship with family factor (r=0.4353, p<0.001).

  • PDF

몬테칼로법을 위한 선량당량 산정법의 도출 (Derivation of a Monte Carlo Estimator for Dose Equivalent)

  • 이재기
    • Journal of Radiation Protection and Research
    • /
    • 제10권2호
    • /
    • pp.89-95
    • /
    • 1985
  • 연속감속근사법(CSDA)과 감속평균선질계수를 이용하여 선량당량 정의에서의 본래의 LET분포 개념을 하전입자속 스펙트럼의 개념으로 변환함으로써 새로운 선량당량 산정법을 도출하였다. 이 산정법을 몬테칼로법에 적용함으로써 주어진 방사선장에 위치한 피사체 내에서의 선량당량을 직접적으로 간편하게 산출할 수 있다. 산정에 필요한 감속평균 선질계수는 중성자와 연조직과의 상호작용으로부터 발생될 수 있는 모든 하전입자에 대하여 10 MeV 이하의 에너지 범위에서 산출하여 제시하였다.

  • PDF

Survey of Radiation Shielding Design Goals and Workload Based on Radiation Safety Report: Tomotherapy Vault

  • Cho, Kwang Hwan;Jung, Jae Hong;Min, Chul Kee;Bae, Sun Hyun;Moon, Seong Kwon;Kim, Eun Seog;Cho, Sam Ju;Lee, Rena
    • 한국의학물리학회지:의학물리
    • /
    • 제29권1호
    • /
    • pp.42-46
    • /
    • 2018
  • The purpose of this study was to perform a survey of the radiation shielding design goals (P) and workload (W) based on the radiation safety reports concerned with structural shielding design for the IMRT treatment technique in Tomotherapy vaults. The values of the P and W factors as well as of a verified concrete thickness of the ceiling, bottom, sidewalls (sidewall-1 and sidewall-2), and door have been obtained from radiation safety reports for a total of 16 out of 20 vaults. The recommended and most widely used report for P values was the NCRP No. 151 report, which stated that the P factor in controlled and uncontrolled areas was 0.1 and 0.02 mSv/week, respectively. The range of the W factor was 600~14,720 Gy/week. The absorbed dose delivered per patient was 2~3 Gy. The maximum number of patients treated per day was 10~70. The quality assurance (QA) dose was 100~1,000 Gy/week. Fifteen values of the IMRT factor (F) were mostly used but a maximum of 20 values was also used. The concrete thickness for primary structures including the ceiling, bottom, sidewalls, and door was sufficient for radiation shielding. The P and W factors affect the calculation of the structural shielding design, and several parameters, such as the absorbed dose, patients, QA dose, days and F factor can be varied according to the type of shielding structure. To ensure the safety of the radiation shielding, it is necessary to use the NCRP No. 151 report for the standard recommendation values.

Analytic Hierarchy Process for Prioritizing Radiation Safety Measures in Medical Institutions

  • Hyun Suk Kim;Heejeong Jeong;Hyungbin Moon;Sang Hyun Park
    • Journal of Radiation Protection and Research
    • /
    • 제49권1호
    • /
    • pp.40-49
    • /
    • 2024
  • Background: This study aimed to prioritize policy measures to improve radiation safety management in medical institutions using the analytic hierarchy process. Materials and Methods: It adopted three policy options-engineering, education, and enforcement-to categorize safety management measures, the so-called Harvey's 3Es. Then, the radiation safety management measures obtained from the current system and other studies were organized into action plan categories. Using the derived model, this study surveyed 33 stakeholders of radiation safety management in medical institutions and analyzed the importance of each measure. Results and Discussion: As a result, these stakeholders generally identified enforcement as the most important factor for improving the safety management system. The study also found that radiation safety officers and medical physicists perceived different measures as important, indicating clear differences in opinions among stakeholders, especially in improving quality assurance in radiation therapy. Hence, the process of coordination and consensus is likely to be critical in improving the radiation safety management system. Conclusion: Stakeholders in the medical field consider enforcement as the most critical factor in improving their safety management systems. Specifically, the most crucial among the six specific action plans was the "reinforcement of the organization and workforce for safety management," with a relative importance of 25.7%.

방사선량의 측정, 평가에서 선량당량(dose equivalent)과 등가선량(equivalent dose)의 정의 및 차이 (Definition and Difference between Dose Equivalent and Equivalent Dose in Radiation Dose Measurement and Evaluation)

  • 장시영
    • Journal of Radiation Protection and Research
    • /
    • 제18권1호
    • /
    • pp.1-7
    • /
    • 1993
  • 국제방사선방어위원회(ICRP)는 최근의 권고 60(1990)에서 이전의 권고 26(1976)에는 없었던 새로운 용어들을 도입하였다. 이중에서도 동 위원회는 지금까지 사용되어 왔던 국제 방사선단위 및 측정위원회(ICRU) 개념의 '션량당량(dose equivalent)'을 대체하는 용어로 '등가선량(equivalent dose)'을 새로 정의하여 방사선방어 프로그램에의 적용을 권고하고 있다. 그러나 한편 동 위원회는 선량 당량이라는 용어도 여전히 채택하고 있기 때문에 경우에 따라 두 양의 사용시 불필요한 혼동을 불러일으킬 수가 있다. 따라서 본 해설문에서는 방사선 방어, 관리 및 측정분야 종사자들의 이해를 돕기 위하여 두 양의 정의와 사용상의 차이점에 대하여 정리하였다.

  • PDF

고 에너지 광자선의 조사선량 측정 시 전리함의 스템효과 보정계수 (Stem Effect Correction Factor of Ionization Chamber in Exposure Measurements of High Energy Photons)

  • 박철우;이재승;권대철;차동수;김진수;김경근
    • 대한디지털의료영상학회논문지
    • /
    • 제12권1호
    • /
    • pp.51-58
    • /
    • 2010
  • Ionization chambers often exhibit a stem effect, caused by interactions of radiation with air near the chamber end, or with dielectric in the chamber stem or cable. In this study measured stem effect correction factor for length of ionization chamber from medical linear accelerator recommend to with the use of stem correction method. For a model of the Farmer-type chamber, were used to calculate the beam quality correction factor. These interactions contribute to the apparent measured exposure. Additionally, it needs to consider ionization chamber use of small volume and stem effect of cable by a large field. Linear accelerator generated photons energy and increased dose repeatedly measured by using stem correction method. Stem effect was dependence of the energy and increases with photon energy conditions improved of beam quality. In conclusion, stem effect correction factor was measured within 0.4% calculated according to the exposures stem length and also supposed to determined below 1% of another stem correction method.

  • PDF

Development of the Numerical Guide for Cost-Benefit Analysis of Occupational Radiation Exposure In the Korean Next Generation Reactor

  • Sohn, Ki-Yoon;Kang, Chang-Sun
    • Nuclear Engineering and Technology
    • /
    • 제29권1호
    • /
    • pp.78-84
    • /
    • 1997
  • The specific purpose of this study is to develop the numerical guide for the cost-benefit analysis of ORE ($/person-Sv reduction) to meet the criterion of ALARA in the design stage of the KNGR. In deriving the guide, the risk factor which is defined by the risk to unit collective radiation exposure dose (deaths/person-Sv) and the monetary value of human life ($/death) are required. The risk factor has been estimated from various clinical data accumulated for a number of years and continuously modified. And the monetary value of human life is usually quantified using the human capital approach. In this study, the risk to radiation exposure perceived by a group of people is investigated through an extensive poll survey conducted among university students in order to modify the existing risk factor for radiation exposure. And in evaluating the monetary value of human life, the QOL factor is introduced in order to incorporate the degree of public welfare or quality of life. As a result of study, a value within the range of 151, 000~172, 000 dollars per person-Sv reduction is recommended as the appropriate interim numerical guide for cost-benefit analysis of ORE to meet the criterion of ALARA in the design stage of the KNGR. A poll survey was also conducted in order to see whether the public acceptance cost of nuclear power should be incorporated in developing the guide, and the result of study shooed that such a cost does not need to be considered.

  • PDF

원통형 전리함을 이용한 Ir-192 선원에 대한 공기커마세기 측정 시 선질보정에 관한 연구 (Quality Correction for Ir-192 Gamma Rays in Air Kerma Strength Dosimetry Using Cylindrical Ionization Chambers)

  • 정동혁;김진기;김기환;오영기;김수곤;이강규;문성록
    • 한국의학물리학회지:의학물리
    • /
    • 제20권1호
    • /
    • pp.30-36
    • /
    • 2009
  • Co-60 선원에 대해 교정된 원통형 전리함 이용하여 Ir-192 선원에 대한 공기커마세기를 측정하는 경우에 선질 차이에 대한 보정이 필요하다. 본 연구에서는 측정학적 방법을 적용하여 PTW-N30001과 N23333 전리함에 대하여 Ir-192 감마선에 대한 선질 인자를 결정하였다. Ir-192 선원(microSelectron)의 에너지스펙트럼을 적용할 경우에 선질인자($k_u$)는 두 전리함에 대해 각각 $k_u$=1.016 (N30001)과 $k_u$=1.017 (N23333)으로 계산되었다. 치료용 microSelectron 선원에 대해 선질 인자를 적용하여 공기커마 세기를 측정하였으며 결과를 기준값과 비교하였다. 결과적으로 선질인자를 적용하는 경우에 기준 공기커마율과 약 -0.5% 이내의 차이를 보였으며 적용하지 않는 경우에는 약 -2.0%의 차이를 보였다.

  • PDF

몬테카를로 시뮬레이션을 이용한 X선 의료영상 획득 시 산란선 발생 영향 연구 (The Study on Scattered Radiation Effects According to Acquisition of X-ray Imaging using Monte Carlo Simulation)

  • 박지군;강상식;양승우;허예지;김교태
    • 한국방사선학회논문지
    • /
    • 제12권5호
    • /
    • pp.549-555
    • /
    • 2018
  • 방사선 영상 기술은 피사체의 조성 및 두께에 따라 변화되는 X선의 흡수계수 차이를 기반으로 형성되는 대조도를 영상화하는 기술로서 영상 검출기에 입사하는 1차선 뿐 만 아니라 산란선이 영상 품질에 큰 영향을 미친다. 이에 본 연구에서는 피사체 두께, 조사야 변화에 따라 발생하는 산란선이 영상 품질에 미치는 영향을 고찰하고자 몬테카를로 시뮬레이션을 통하여 FSR 및 SPR 분석을 수행하였다. 연구 결과, 피사체 두께에 따른 FSR은 최대 15.3%p, SPR은 2.00 ~ 4.54로 분석되었으나, 조사야 변화에 대해서는 일정한 값을 유지하는 것으로 분석되었다. 이러한 결과를 바탕으로 피사체 두께는 영상 품질에 영향을 미치는 인자로서 고려되어야 하지만, 조사야는 영상 품질에 영향을 미치지 못하는 인자임을 검증하였다. 이러한 본 연구 결과는 영상 품질 개선을 위한 산란선에 대한 기초 자료로서 활용할 수 있을 것으로 사료된다.