• Title/Summary/Keyword: Radiation Generator

검색결과 237건 처리시간 0.029초

Analysis of Status of Radiation/Radioisotopes Utilization

  • Park, Chan Hee;Lee, Seung Hyun;Kim, Na Kyung;Kim, Kon Wuk
    • Journal of Radiation Protection and Research
    • /
    • 제42권1호
    • /
    • pp.1-8
    • /
    • 2017
  • Background: The use of radiation and radioisotopes in Korea has been increasing each year, and its impact on economy and industry is expected to be increasing progressively following the development of industrial technology and the expansion of their usage. To establish and supporting policies for industries using radiation and radioisotopes, it is necessary to check the status of related industries accurately, as well as to gather data required to establish plans for industrial development by studying both revenues and economic scale (contributing to revenue). Materials and Methods: To analyze the status of utilization, surveys were carried out on 6,621 organizations engaged in nuclear operations handling radiation and radioisotopes pursuant to the Nuclear Safety Act as of end 2014, on 33,471 medical institutions using radiation generators for medical and diagnostic purposes pursuant to the Medical Service Act, and on 2,218 organizations using radiation generators for animal diagnostics pursuant to the Veterinary License Act. Results and discussion: The overall status of the domestic radiation market including the number of user organizations, that of employees, and the size of distributions (imports, productions, and exports) with which the scale of domestic radiation market can be judged showed a growth trend compared to the previous year, though the number of employees for radiation operation in industrial sector, research sector, education sector, military sector, and power plants (nuclear power plants) and the size of imports was reduced somewhat. Conclusion: It is expected that data acquired through periodic surveys on the status of utilization would be utilized practically in establishing governmental policies related to the promotion of usage of radiation and radioisotopes, and also be utilized widely in cultivating and developing the industry efficiently to invigorate the related industries.

Review of Shielding Evaluation Methodology for Facilities Using kV Energy Radiation Generating Devices Based on the NCRP-49 Report

  • Na Hye Kwon;Hye Sung Park;Taehwan Kim;Sang Rok Kim;Kum Bae Kim;Jin Sung Kim;Sang Hyoun Choi;Dong Wook Kim
    • Progress in Medical Physics
    • /
    • 제33권4호
    • /
    • pp.53-62
    • /
    • 2022
  • In this study, we have investigated the shielding evaluation methodology for facilities using kV energy generators. We have collected and analysis of safety evaluation criteria and methodology for overseas facilities using radiation generators. And we investigated the current status of shielding evaluation of domestic industrial radiation generators. According to the statistical data from the Radiation Safety Information System, as of 2022, a total of 7,679 organizations are using radiation generating devices. Among them, 6,299 facilities use these devices for industrial purposes, which accounts for a considerable portion of radiation. The organizations that use these devices evaluate whether the exposure dose for workers and frequent visitors is suitable as per the limit regulated by the Nuclear Safety Act. Moreover, during this process, the safety shields are evaluated at the facilities that use the radiation generating devices. However, the facilities that use radiating devices having energy less than or equal to 6 MV for industrial purposes are still mostly evaluated and analyzed according to the National Council on Radiation Protection and Measurements 49 (NCRP 49) report published in 1976. We have investigated the technical standards of safety management, including the maximum permissible dose and parameters assessment criteria for facilities using radiation generating devices, based on the NCRP 49 and the American National Standards Institute/Health Physics Society N.43.3 reports, which are the representative reports related to radiation shielding management cases overseas.

The first private-hospital based proton therapy center in Korea; status of the Proton Therapy Center at Samsung Medical Center

  • Chung, Kwangzoo;Han, Youngyih;Kim, Jinsung;Ahn, Sung Hwan;Ju, Sang Gyu;Jung, Sang Hoon;Chung, Yoonsun;Cho, Sungkoo;Jo, Kwanghyun;Shin, Eun Hyuk;Hong, Chae-Seon;Shin, Jung Suk;Park, Seyjoon;Kim, Dae-Hyun;Kim, Hye Young;Lee, Boram;Shibagaki, Gantaro;Nonaka, Hideki;Sasai, Kenzo;Koyabu, Yukio;Choi, Changhoon;Huh, Seung Jae;Ahn, Yong Chan;Pyo, Hong Ryull;Lim, Do Hoon;Park, Hee Chul;Park, Won;Oh, Dong Ryul;Noh, Jae Myung;Yu, Jeong Il;Song, Sanghyuk;Lee, Ji Eun;Lee, Bomi;Choi, Doo Ho
    • Radiation Oncology Journal
    • /
    • 제33권4호
    • /
    • pp.337-343
    • /
    • 2015
  • Purpose: The purpose of this report is to describe the proton therapy system at Samsung Medical Center (SMC-PTS) including the proton beam generator, irradiation system, patient positioning system, patient position verification system, respiratory gating system, and operating and safety control system, and review the current status of the SMC-PTS. Materials and Methods: The SMC-PTS has a cyclotron (230 MeV) and two treatment rooms: one treatment room is equipped with a multi-purpose nozzle and the other treatment room is equipped with a dedicated pencil beam scanning nozzle. The proton beam generator including the cyclotron and the energy selection system can lower the energy of protons down to 70 MeV from the maximum 230 MeV. Results: The multi-purpose nozzle can deliver both wobbling proton beam and active scanning proton beam, and a multi-leaf collimator has been installed in the downstream of the nozzle. The dedicated scanning nozzle can deliver active scanning proton beam with a helium gas filled pipe minimizing unnecessary interactions with the air in the beam path. The equipment was provided by Sumitomo Heavy Industries Ltd., RayStation from RaySearch Laboratories AB is the selected treatment planning system, and data management will be handled by the MOSAIQ system from Elekta AB. Conclusion: The SMC-PTS located in Seoul, Korea, is scheduled to begin treating cancer patients in 2015.

Knowledge, Attitude, and Practice of Radiation Management among Radiation Generating Device Manufacturers and Medical Personnel (방사선 발생장치 제조업체 및 의료기관 종사자의 방사선 관리에 대한 지식, 태도 및 실천)

  • Kim, Kyu-Hwan;Bae, Seok-Hwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • 제22권2호
    • /
    • pp.418-426
    • /
    • 2021
  • This study investigates the perception of radiation safety management in radiation generator manufacturing workers and medical institutions. The basic data obtained is further applied to improve active coping ability and safety levels. The knowledge and attitude practice score of radiation was found to be related to gender, age, marital status, occupation, position, current work period, total work period, radiation related work period, the manual available, defense facility maintenance, number of defense equipment, radiation safety education, special health examination, and recognition of radiation terms. In particular, the knowledge score of radiologists was highest among the radiation-related occupations (<0.05). Radiation safety management requires active defense endeavors to prevent radiation exposure, by both workers of radiation manufacturers and medical institutions. Moreover, institutional devices such as compliance with guidelines, periodic education, facility reinforcement, manual preparation, and special health checkups are required for efficient radiation safety management.

Fabrication and characterization of plastic fiber-optic radiation sensor tips using inorganic scintillator material (무기 섬광체를 이용한 플라스틱 광섬유 방사선 센서부 제작 및 특성평가)

  • Hwang, Young-Muk;Cho, Dong-Hyun;Lee, Bong-Soo;Cho, Hyo-Sung;Kim, Sin
    • Journal of Sensor Science and Technology
    • /
    • 제14권4호
    • /
    • pp.244-249
    • /
    • 2005
  • In this study, radiation sensor tips are fabricated for remote sensing of X or gamma ray with inorganic scintillators and plastic optical fiber. The visible range of light from the inorganic scintillator that is generated by radiation source is guided by the plastic optical fiber and is measured by optical detector and power-meter. Two kinds of sensor tips are designed and fabricated such as film type and powder type. Many kinds of inorganic scintillators are used to fabricate both sensor tips, and the different wavelength of emitting lights from them are measured to determine the optimal inorganic scintillator which has maximum light output. As a radiation source X-ray generator and Ir-192 are selected to test a performance of sensor tip. It is expected that the fiber-optic radiation sensor is widely used in nuclear industry and medical applications due to its special characteristics such as good flexibility, easy in processing, long lengths and no interference to electro magnetic field.

Radiation safety management for diagnostic radiation generators and employees in animal hospitals in Korea (동물병원의 진단용 방사선 발생장치 및 방사선종사자 안전관리 실태 조사)

  • An, Hyo-Jin;Kim, Chung-Hyun;Kwon, Young-Jin;Kim, Don-Hwan;Wee, Sung-Hwan;Moon, Jin-San
    • Korean Journal of Veterinary Research
    • /
    • 제54권3호
    • /
    • pp.151-157
    • /
    • 2014
  • A nationwide survey on radiation safety management in Korean animal hospitals was conducted. By 2013, 53 radiation generators were registered as veterinary medical devices (41 X-ray generators and 12 computed tomography scanners). Additionally there were six approved laboratories for radiation equipment and protection facility, and five approved laboratories for radiation exposure of employees, respectively. By March 2013, 2,030 out of 3,829 animal hospitals operated radiation-generating devices. Among these devices, 389 (19.2%) out of 2,030 were not labeled with the model name and 746 (36.7%) were not labeled with production dates. Thus, most veterinary X-ray generators were outdated (42.6%) and needed replacements. When periodic inspections of 2,018 animal hospitals were performed after revision of the Veterinarians Act in 2011, the hospitals were found to be equipped with appropriate radiation generators and protection facilities. Among 2,545 employees exposed to radiation at the hospitals, 93.9% were veterinarians, 4.3% were animal nurse technicians, and 18% held other positions. Among 169 employees supervised by administrators, none of those had a weekly maximum operating load that exceeded $10mA{\cdot}min$. This study suggests that the radiation safety management system of animal hospitals was general good.

Nozzle Dam Design Improvement in Steam Generator (증기 발생기용 노즐댐 설계개선)

  • Kim, Tae-Ryong;Park, Jin-Seok;Jung, Seung-Ho;Park, Jin-Ho
    • Nuclear Engineering and Technology
    • /
    • 제27권3호
    • /
    • pp.327-335
    • /
    • 1995
  • The normal shutdown and maintenance period of a nuclear power plant can be remarkably shortened when the examination and maintenance works in steam generator tubes are simultaneously carried out with refueling job. There are nozzle dams to Hock the coolant How from reactor to steam generator. Workers are reluctant to install nozzle dam because of the high radiation exposure and the limited working space in steam generator. Moreover, the heavy weight of present nozzle dam makes it installation and removal works much difficult. In this paper, a lighter KAERI nozzle dam with increased flexural rigidity-to-weight was designed and manufactured by changing the structure design of the present nozzle dam and by selecting new material, carbon fiber-reinforced plastic.

  • PDF

Study of a Protection Technology to the Transient Radiation for the Semiconductors (반도체에 대한 과도방사선 방호기술연구)

  • Lee, Nam-ho;oh, Sung-Chan;Jeong, Sang-hun;Hwang, Young-gwan;Kim, Jong-yul
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 한국정보통신학회 2013년도 춘계학술대회
    • /
    • pp.1023-1026
    • /
    • 2013
  • The electronic equipment which was exposed to high level pulsed radiation is damaged as Upset, Latchup, and Burnout. Those damages has come from the instantaneous photocurrent from electron-hole pairs generated in itself. Such damages appeared as losses of power in military weapon system or of blackout in aerospace equipment and eventually caused in gross loss of national. In this paper, we have implemented a RDC(Radiation detection and control module) as part of the radiation protection technology of the electronic equipment or devices from the pulsed gamma radiation. The RDC which is composed of pulsed gamma-ray detection sensor, signal processors, and pulse generator is designed to protect the important electronic circuits from the pulse radiation. To verify the functionality of the RDC, LM118s which had damaged by the pulse radiation were tested. The test results showed that the test sample applied with a RDC was worked well in spite of the irradiation of the same pulse radiation. Through the experiments we could confirm that the radiation protection technology implemented with RDC had the functionality of radiation protection to the electronic devices.

  • PDF

Developement of Radiation Measuring System using Wireless Communication (무선통신을 이용한 방사선측정 시스템 개발)

  • Lee, Bong-Jae;Chang, Si-Young
    • Journal of Radiation Protection and Research
    • /
    • 제20권2호
    • /
    • pp.85-95
    • /
    • 1995
  • Radiation measuring system using wireless communication method with single channel has been diveloped and tested. In this system, radiation signals from GM tube are transformed into digital pulses in pulse processing circuit and modulated in FSK (frequency shift keying) circuit for digital communication and then wirelessly transmitted to a receiving unit. The digital pulses received are then demodulated in FSK circuit and converted into radiation dose/dose rate in the data acquisition unit to display on the screen of a personal computer. The performance of this system was evaluated by using both a pulse generator and a standard radiation source(Cs-137). In both cases, digital pulses with 5V were observed in pulse processing circuit without distortion of their shape through wireless communication system. The experimental results of radiation measurement by this system after several test-irradiation of GM detector to a standard radiation source(Cs-137), showed good agreement with irradiation dose rate within 10% difference, and proved that this system could be effectively utillized as radiation measuring instrument. It is expected that this wireless radiation measuring system developed for the first time in Korea, can be used as a radiation monitor as well as a personal dosimeter if we can further improve this system to adopt wireless multichannel communication system.

  • PDF

The Determination of Radon Progeny Concentration in Controlled Radon Environment (라돈을 제어하는 환경에서 라돈 자핵종의 농도 결정)

  • Seo, Kyung-Won;Lee, Byung-Kee
    • Journal of Radiation Protection and Research
    • /
    • 제18권1호
    • /
    • pp.37-51
    • /
    • 1993
  • A standard radon chamber and a radon generator adjusted by ventilation system which had used in this research were assumed to calculate theoretically the concentration of radon progeny using Jacobi model theory. On the one hand, the filter sampled from the radon standard chamber and the radon generator was measured and analysed by the alpha spectrometry method. It is clear that measured result shows a good agreement with theoretical result. Therefore, it is observed that this research can made a great contribution to more accurate internal dose assessment by alpha emission of radon progeny in indoor radon environment, and fast individual measurement and determination of concentration for radon progeny.

  • PDF