• 제목/요약/키워드: Radiation Generator

검색결과 229건 처리시간 0.027초

방사선안전관리책임자 보수교육의 현황에 따른 정합성 판단 (Determination of Consistency according to the Status of Supplementary Education for Radiation Safety Management Managers)

  • 김승철
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제47권1호
    • /
    • pp.7-12
    • /
    • 2024
  • Medical institutions wishing to install and operate diagnostic radiation generators must complete appointment training within one year of appointment based on the 「Medical Act」 and the 「Rules on Safety Management of Diagnostic Radiation Generator Devices」 which will come into effect on January 1, 2024. Additionally, You must receive supplementary education every three years from the date you received it. The strengthening of safety management for diagnostic radiation generators used in medical institutions means that although the radiation exposure that may occur when using diagnostic radiation generators is low, the risk of carcinogenesis may be higher than previously evaluated. In addition, safety management of diagnostic radiation generators can be said to be an essential requirement because it has been reported that the incidence of leukemia and other diseases is increasing in diagnostic radiation tests. However, the safety management training targets and programs for radiation exposure management operated by other organizations other than diagnostic radiation generators are significantly different. In addition, since the public institutions that are responsible for radiation safety management are divided, there is a risk of duplicative, excessive, and under-administrative application to medical institutions and educational institutions that install and operate diagnostic radiation generators. Therefore, we would like to determine their consistency by comparing domestic and foreign related cases and the provisions of the 「Medical Act」 and the 「Nuclear Safety Act」.

원전 종사자의 말단선량평가를 위한 고피폭 접촉 방사선장 특성분석 (An Analysis of Radiation Field Characteristics for Estimating the Extremity Dose in Nuclear Power Plants)

  • 김희근;공태영
    • Journal of Radiation Protection and Research
    • /
    • 제34권4호
    • /
    • pp.176-183
    • /
    • 2009
  • 원전 계획예방정비기간 증기발생기 수실작업 등은 매우 높은 방사선량율을 보이는 지역으로, 짧은 시간 동안 작업으로 종사자는 높은 피폭을 받을 가능성이 있다. 특히, 방사성물질과 접촉작업을 하는 손 부위에서 고피폭이 예상된다. 이런 점을 고려하여 2004년 수행된 국내 원전의 복수선량계 알고리즘 적용성 시험의 TLD 판독결과를 이용하여 고피폭 접촉 작업의 방사선장을 분석하였다. 그 결과, 원전 고피폭 접촉작업의 입사방사선장은 고에너지 광자(High Energy Photon Field)에 의한 피폭으로 해석되었다. 한편 2009년 울진 4호기 계획예방정비기간 S/G 정비작업과 월성 1호기 압력관 교체작업에 참여한 방사선작업종사자에 대해 말단선량 현황과 방사선장을 분석하기위한 현장시험을 실시하였다. 그 결과 입사방사선장은 고에너지 방사선장으로 확인되었다.

와동 발생기를 이용한 자외선 살균 시스템 성능 향상에 관한 연구 (A Study on Enhancement of UV Disinfection System Performance by the Vortex Generator)

  • 김봉환;안국찬;김동진
    • 한국안전학회지
    • /
    • 제22권1호
    • /
    • pp.24-29
    • /
    • 2007
  • The effectiveness of a UV(ultra violet) disinfection system depends on the characteristics of the waste water, flow conditions, the intensity of UV radiation, the amount of time the microorganisms are exposed to the radiation, and the reactor configuration. The wast water flow conditions are important factors in the design of UV disinfection system from the point of enhancement view of UV disinfection. The turbulent energy intensity in the wake by the vortex shedding are effective for UV radiation. Therewith the effectiveness of vortex generator is considered as a enhancement of UV disinfection. The experimental results presented give important evidences and explain that it is possible to predict UV disinfection performance based on flow experiments. An experimental investigation of two types of the vortex generator is presented. The qualitative and quantitative evaluations of the wake are made by flow visualization using smoke wire method and the measurement of vortex frequencies in the wind tunnel. From the experiment, following results were obtained that the delta wing type vortex generator is more effective than circular type because of the higher vortex frequencies and the smaller drag.

원전 스팀 제네레이터의 자동보수 유지를 위한 로보트비젼 시스템 개발 (Development of a Robot Vision System for Automatic Repair and Maintenance of Steam Generator in Nuclear Power Plants)

  • 한성현
    • 한국생산제조학회지
    • /
    • 제6권4호
    • /
    • pp.9-18
    • /
    • 1997
  • It is proposed a new approach to the development of the automatic vision system to examine and repair the steam generator tubes at remote distance. In nuclear power plants, workers are reluctant of works in steam generator because of the high radiation environment and limited working space. It is strongly recommended that the examination and maintenance works be done by an automatic system for the protection of the operator from to radiation exposure. Digital signal processors are used in implementing real time recognition and examination of steam generator tubes in the proposed vision system. Performance of proposed digital vision system is illustrated by simulation and experiment for similar steam generator model.

  • PDF

Generator 컬럼용 68GeO2 합성 및 68Ga3+의 거동에 관한 연구 (Study on Synthesis of 68GeO2 and Behavior of 68Ga3+ for Generator Column)

  • 김건균;이준영;김상욱;허민구;양승대;박정훈
    • 방사선산업학회지
    • /
    • 제10권4호
    • /
    • pp.189-192
    • /
    • 2016
  • $^{68}Ga$ has emerged as a promising candidate for non-invasive diagnostic imaging within Positron Emission Tomography (PET) because of its advantageous radiochemical characteristics ($t_{1/2}=68min$, ${\beta}^+$ yield ~89%). $^{68}Ga$ forms a stable chelation with various ligands and it is possible to be quickly and easily study using a $^{68}Ge/^{68}Ga$ generator. Commercial $^{68}Ge/^{68}Ga$ generators are chromatographic system using the inorganic materials such as alumina and tin dioxide which are employed as column matrixes for $^{68}Ge$. In this study, we tried out to make $^{68}Ge/^{68}Ga$ generator system with the $^{68}GeO_2$ microstructures for column matrix. $^{68}Ge$ tends to have stable bond with oxide as $^{68}GeO_2$ microstructures. The $^{68}GeO_2$ has been synthesized by hydrolysis of $GeCl_4$ (sol-gel method) and characterized by X-ray diffraction and scanning electron microscope for geometrical analysis. The stability of $GeO_2$ was tested using eluents with diverse solvents(water, ethanol and 0.1 N HCl). The radioactivity of $^{68}Ga^{3+}$ in eluate through $GeO_2$ was measured to prove a function as column material for a generator.

Analytic simulator and image generator of multiple-scattering Compton camera for prompt gamma ray imaging

  • Kim, Soo Mee
    • Biomedical Engineering Letters
    • /
    • 제8권4호
    • /
    • pp.383-392
    • /
    • 2018
  • For prompt gamma ray imaging for biomedical applications and environmental radiation monitoring, we propose herein a multiple-scattering Compton camera (MSCC). MSCC consists of three or more semiconductor layers with good energy resolution, and has potential for simultaneous detection and differentiation of multiple radio-isotopes based on the measured energies, as well as three-dimensional (3D) imaging of the radio-isotope distribution. In this study, we developed an analytic simulator and a 3D image generator for a MSCC, including the physical models of the radiation source emission and detection processes that can be utilized for geometry and performance prediction prior to the construction of a real system. The analytic simulator for a MSCC records coincidence detections of successive interactions in multiple detector layers. In the successive interaction processes, the emission direction of the incident gamma ray, the scattering angle, and the changed traveling path after the Compton scattering interaction in each detector, were determined by a conical surface uniform random number generator (RNG), and by a Klein-Nishina RNG. The 3D image generator has two functions: the recovery of the initial source energy spectrum and the 3D spatial distribution of the source. We evaluated the analytic simulator and image generator with two different energetic point radiation sources (Cs-137 and Co-60) and with an MSCC comprising three detector layers. The recovered initial energies of the incident radiations were well differentiated from the generated MSCC events. Correspondingly, we could obtain a multi-tracer image that combined the two differentiated images. The developed analytic simulator in this study emulated the randomness of the detection process of a multiple-scattering Compton camera, including the inherent degradation factors of the detectors, such as the limited spatial and energy resolutions. The Doppler-broadening effect owing to the momentum distribution of electrons in Compton scattering was not considered in the detection process because most interested isotopes for biomedical and environmental applications have high energies that are less sensitive to Doppler broadening. The analytic simulator and image generator for MSCC can be utilized to determine the optimal geometrical parameters, such as the distances between detectors and detector size, thus affecting the imaging performance of the Compton camera prior to the development of a real system.

X-선 발생장치 정류방식에 따른 출력특성에 관한 연구

  • 나길주;백수웅;양현훈;박계춘
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 추계학술대회 논문집
    • /
    • pp.126-126
    • /
    • 2009
  • X-ray high-voltage generator is the most important part that can decide the radiation exposure dose affecting a patient or operator according to the characteristic. If decrease of X-ray radiation exposure dose and output characteristic of high-voltage generator is unstable, a patient or operator must be exposed to more radiation. This study measures and analyzes the exposure dose reproducibility and output characteristic according to a change of tube current on the various rectification methods of diagnostic X-ray equipment. It can find that quality bastardize and output is increased if voltage of X-ray tube is increased. Exposure dose reproducibility according to output of X-ray equipment is extremely excellent in inverter type, and is stable in order of following three-phase, a single-phase and condenser method. This study can find that the reply incidence of high-voltage generator is generated due to difference in rectification method, noise occurs in X-ray due to that, quality of an image is decreased due to that, and medical diagnosis can be failed due to that.

  • PDF

마코프 모델을 이용한 방사선 방어의 최적화 (Optimization of Radiation Protection Using Markov Model)

  • 정진엽;이건재
    • Journal of Radiation Protection and Research
    • /
    • 제14권2호
    • /
    • pp.1-9
    • /
    • 1989
  • 방사선 방어를 위한 방안을 결정하는데 도움을 주기 위해서는 각종 방사선 방어 최적화 방안들 사이에 정량적인 비교를 할 수 있는 해석적 방법이 필요하다. 본 논문에서는 발전소에서 행해지고 있는 검사, 시험 및 보수가 방사선 방어에 미치는 영향을 평가할 수 있는 동적 마코프 모델의 개념을 도입하였다. 마코프 모델의 응용을 다루기 위해 예로 든 증기발생기 전열관 파열에서는 고리 2호기와 외국의 자료에 기초해 비용과 피폭 선량을 줄이기 위한 증기발생기의 최적 검사주기를 산출하였으며 그 결과 피폭 선량은 비용에 비해 그 기여도가 매우 낮은 것으로 나타났다. 예제 계산이 이용된 마코프 모델은 자료를 좀 더 보강함으로써 국내 발전소에도 쉽게 적용할 수 있으며 방사선 방어의 최적화를 위한 여러 가지 대안의 비교 우위를 평가하는 데에도 이용할 수 있다.

  • PDF

고속 고정밀 중성자 측정을 위한 하드웨어 설계에 관한 연구 (A Study On Hardware Design for High Speed High Precision Neutron Measurement)

  • 장경욱;이주현;이승호
    • 전기전자학회논문지
    • /
    • 제20권1호
    • /
    • pp.61-67
    • /
    • 2016
  • 본 논문에서는 중성자 방사선 측정을 위한 고속 고정밀 중성자 측정을 위한 하드웨어 설계방법을 제안한다. 제안된 고속 고정밀 중성자 측정 장치의 하드웨어 설계는 고성능 A/D 변환기를 사용하여 고정밀 고속의 아날로그 신호를 디지털 데이터로 변환할 수 있도록 구성된다. 중성자 센서를 사용하여 입사된 중성자 방사선 입자를 검출하고, 극저전류 정밀 측정 모듈을 통해 검출된 중성자 방사선을 보다 정밀하고 빠르게 측정하는 모듈을 설계한다. 고속 고정밀 중성자 측정을 위한 하드웨어 시스템은 중성자 센서부, 가변 고전압 발생부, 극저전류 정밀 측정부, 임베디드 시스템부, 디스플레이부 등으로 구성 된다. 중성자 센서부는 고밀도 폴리에틸렌을 통해 중성자 방사선을 검출하는 기능을 수행한다. 가변 고전압 발생부는 중성자 센서가 정상적으로 운영되기 위하여 발열 및 잡음 특성에 강인한 0 ~ 2KV 가변 고전압 발생장치의 기능을 수행한다. 극저전류 정밀 측정부는 중성자 센서에서 출력되는 고정밀 고속의 극저전류 신호를 고성능 A/D 변환기를 사용하여 정밀하고 빠르게 측정하고 아날로그 신호를 디지털 신호로 변환하는 기능을 수행한다. 임베디드 시스템부는 고속 고정밀 중성자 측정을 위한 중성자 방사선 측정 기능, 가변 고전압 발생장치 제어 기능, 유무선 통신 제어 기능, 저장 기능 등을 수행한다. 제안된 고속 고정밀 중성자 측정을 위한 하드웨어를 실험한 결과, 불확도, 중성자 측정 속도, 정확도, 중성자 측정 범위 등에서 기존의 장치보다 우수한 성능이 나타남을 확인할 수가 있다.