Characteristics of Specific Absorption Rate (SAR) in Electromagnetic (EM) Dosimetry

  • Hwang, Sun-Tae;Choi, Kil-Oung
    • Journal of Radiation Protection and Research
    • /
    • 제25권2호
    • /
    • pp.109-114
    • /
    • 2000
  • The SI unit of specific absorption rate (SAR) in W/kg in the electromagnetic (EM) field as non-ionizing radiation is exactly same as the SI unit of absorbed dose rate in Gy/s in the ionizing radiation field. The SI unit of both physical quantities can be expressed in $[m^{\cdot}s^{-3}]$. Where, the unit of absorbed dose, Gy stands for Gray. In EM biological interactions, the SAR equations are derived and the characteristics of EM field energy absorption in terms of the SAR are discussed and described on the mathematical basis.

  • PDF

골반부 방사선 치료 환자에서 in vivo 선량측정시스템의 임상적용 (Clinical Application of in Vivo Dosimetry System in Radiotherapy of Pelvis)

  • 김보경;지의규;허순녕;이형구;하성환
    • Journal of Radiation Protection and Research
    • /
    • 제27권1호
    • /
    • pp.37-49
    • /
    • 2002
  • 방사선치료 시 종양에 정확한 양의 방사선을 조사하는 것은 국소 재발을 방지하고 합병증의 빈도를 낮춰 효과적인 치료를 가능하게 하는 중요한 요소이다. 종양에 조사되는 방사선량의 측정을 통해 치료의 정확성을 확인하기 위한 여러 방법들이 시도되고 있으며, 투과선량을 이용한 측정법도 그 중 한 예로 비침습적이며 매 치료 시 측정이 가능한 장점을 가지고 있다. 본 교실에서는 투과선량을 이용한 in vivo 선량측정시스템과 임의의 치료 조건에서 투과선량을 계산하기 위한 알고리즘을 개발하였다. 본 교실에서 개발한 in vivo 선량측정시스템의 단기간 및 장기간의 재현성을 확인하고, 환자의 방사선치료에서의 이용 시 발생할 수 있는 문제점을 파악하고 알고리즘의 정확성을 확인하기 위하여 본 연구를 시행하였다. 2000년 7월 25일부터 8월 14일 사이에 방사선치료를 시행 받은 환자 66명을 대상으로 투과선량의 측정을 시행하였으며, 이 중 골반부위의 방사선 치료를 3회 이상 시행 받은 11명의 환자를 대상으로 측정선량과 예측선량의 비교 분석을 시행하였다. 측정시스템의 재현성의 확인을 위하여 환자의 치료 전 및 치료 중 매시간 기준 조사조건에서 측정치를 확인하였다. 일별 및 일 중 변동은 ${\pm}2%$ 이내로 재현성을 확인할 수 있었다. 본 시스템의 사용 시 별다른 문제점은 없었으나, 2명의 흉부 치료환자에서 투과선이 치료용테이블의 측면 금속을 관통하는 문제가 발생하였다. 골반부위 환자에서는 골반부위의 불균질조직에 의한 영향의 확인을 위하여, CT 및 simulation film을 이용하여 골 조직의 두께를 확인하여 보정 전 및 후의 값을 비교하였다. 전후방 및 후방조사야의 경우 골 조직의 보정을 시행하지 않은 경우 평균오차가 -5.20% 내지 +2.20%이었으며, 보정을 시행한 경우 -0.62%내지 +3.32%로 환자에 따라 정도의 차이는 있으나 골 보정이 필요함을 확인할 순 있었다. 측정치와 예측치 간 오차의 표준편차는 1.19%내지 2.46%로서 재현성이 높음을 확인할 수 있었다. 좌우 측방조사야에서 골 보정을 시행하지 않은 경우 평균오차는 -10.80%내지 +3.46%로서 골 조직의 보정이 필요하지 않은 1인의 환자를 제외하면 모두 음수 값을 지녔고, 보정을 시행한 경우 -0.55% 내지 +3.50%의 평균오차를 지녀 골 보정의 필요성을 확인할 수 있었다. 측정치와 예측치 간 오차의 표준편차는 1.09%내지 6.98%로 전후방조사야의 경우보다 재현성이 낮음을 알 수 있었다. 복와위로 방사선치료를 시행 받은 환자의 경우를 제외하면, 표준편차는 1.09%내지 3.12%로 1례 외에는 2.57% 이내로 재현성이 높음을 확인할 수 있었다. 본 실험을 통하여 in vivo 선량측정시스템의 안전성과 재현성을 확인할 수 있었다. 정확한 예측치를 얻기 위하여 불균질 조직이 조사야에 포함되는 경우 보정이 요구되며, 골반의 경우 골 조직의 보정이 중요한 요인임을 알 수 있었다. 이를 위하여 불균질 조직에 대한 정확한 정보가 요구되며, 이는 CT 영상을 이용하는 것이 크게 도움이 되리라 생각된다.

방사선 치료시 생식선 차폐체 성능 평가를 위한 MOSFET 선량 측정 (MOSFET Dosimetry for Evaluation of Gonad Shielding during Radiotherapy)

  • 김휘영;최윤석;박소연;박양균;예성준
    • Journal of Radiation Protection and Research
    • /
    • 제36권1호
    • /
    • pp.23-27
    • /
    • 2011
  • 방사선 치료를 받는 환자의 생식선에 대한 피폭 선량을 최소화하기 위한 차폐체의 성능을 MOSFET 측정을 통해 평가하고자 서울대학교 병원 방사선 종양학과에서 4명의 남자 직장암 환자를 대상으로 2009 년 이후로 시행한 생식선 차폐체 선량 측정 결과를 이용하였다. 환자 치료는 Varian 21EX 선형가속기 (LINAC) 에서 방출되는 6 MV 와 15 MV 의 X.ray 를 이용하였다. 선형가속기의 조준기 (collimator) 등에 의한 산란선 (scattered ray) 뿐만 아니라 방사선조사영역(radiation field) 내의 치료부위로부터 산란되어 전달되는 산란선을 최소로 하기 위하여 3면이 모두 차폐될 수 있도록 차폐체는 상자 모양으로 제작되었다. 차폐체는 납으로 만든 $7.5\;cm\;{\times}\;9.5\;cm\;{\times}5.5\;cm$ 크기의 상자와 $9\;cm\;{\times}\;9.5\;cm\;{\times}\;1\;cm$ 크기의 덮개로 이루어져 있다. 차폐체의 성능 평가를 위한 선량 측정은 MOSFET 을 이용하였다. 생식선 차폐체를 이용한 경우 차폐체 안쪽의 피폭 선량이 바깥쪽에 비해 평균적으로 23.07% 로 감소하였다. 차폐체 안쪽에 전달된 선량은 평균 0.01 Gy (표준편차 0.004 Gy) 로 측정되었다. 차폐체의 성능은 환자들 별로 적게는 18.76%부터 많게는 38.20% 까지 차이를 보였으나 전달된 절대적 선량은 무정자증 (aspermia) 의 가능성이 있는 0.35 Gy 와, 불임을 초래할 수 있는 2.0 Gy 의 기준치 이하로서, 차폐체의 효과는 충분한 것으로 확인할 수 있다. MOSFET 측정 결과, 생식선 차폐체를 이용하여 환자 생식선에 피폭되는 선량을 효과적으로 감소시킬 수 있음을 확인하였다. 기존의 연구에서 TLD 를 이용한 측정과 비교하여 MOSFET 을 이용하였을 때 보다 실시간으로 정확하게 차폐체에 의한 생식선의 선량 감소 효과를 평가할 수 있음을 확인하였다.

Study of Neutron Detection with OSL

  • 홍덕균;김명진;박세환;이정일
    • 대한방사선방어학회:학술대회논문집
    • /
    • 대한방사선방어학회 2011년도 추계 학술발표회 및 심포지엄
    • /
    • pp.290-291
    • /
    • 2011
  • PDF

EPR Dosimetry for ageing effect in NPP

  • Choi, Hoon;Lim, Young-Ki;Kim, Jong-Seog;Jung, Sun-Chul
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 2005년도 추계학술발표회
    • /
    • pp.973-974
    • /
    • 2005
  • PDF

THREE-DIMENSIONAL VERIFICATION OF INTRACRANIAL TARGET POINT DEVIATION USING MRI-BASED POLYMER-GEL DOSIMETRY FOR CONVENTIONAL AND FRACTIONATED STEREOTACTIC RADIOSURGERY

  • Lee, Kyung-Nam;Lee, Dong-Joon;Suh, Tae-Suk
    • Journal of Radiation Protection and Research
    • /
    • 제36권3호
    • /
    • pp.107-118
    • /
    • 2011
  • Conventional (SRS) and fractionated (FSRS) stereotactic radiosurgery necessarily require stringent overall target point accuracy and precision. We determine three-dimensional intracranial target point deviations (TPDs) in a whole treatment procedure using magnetic resonance image (MRI)-based polymer-gel dosimetry, and suggest a technique for overall system tests. TPDs were measured using a custom-made head phantom and gel dosimetry. We calculated TPDs using a treatment planning system. Then, we compared TPDs using mid bi-plane and three-dimensional volume methods with spherical and elliptical targets to determine their inherent analysis errors; finally, we analyzed regional TPDs using the latter method. Average and maximum additive errors for ellipses were 0.62 and 0.69 mm, respectively. Total displacements were 0.92 ${\pm}$ 0.25 and 0.77 ${\pm}$ 0.15 mm for virtual SRS and FSRS, respectively. Average TPDtotal at peripheral regions was greater than that at central regions for both. Overall system accuracy was similar to that reported previously. Our technique could be used as an overall system accuracy test that considers the real radiation field shape.

자궁강내 근접방사선조사시 인체조직등가 팬톰을 이용한 방사선량 측정 (Measurement of Radiation Using Tissue Equivalent Phantom in ICR Treatment)

  • 장홍석;서태석;윤세철;유미령;박용휘;신경섭
    • Journal of Radiation Protection and Research
    • /
    • 제20권1호
    • /
    • pp.45-52
    • /
    • 1995
  • 자궁경부암환자에서 자궁강내 근접 방사선조사시 선원 배열에 따른 선량분포와 임상적으로 중요한 표식점인 A 및 B점 선량값에 대한 정확성을 평가하기 위하여 조직등가 팬톰을 제작하고 필름선량계측법을 적용하여 측정한 후, 이를 along-away에 의한 계산과 전산화치료계획장치에 의한 값과 비교 분석하였다. 대상 및 방법 : 자궁강내 근접 방사선조사시 치료상태를 그대로 묘사할 수 있게 아크릴과 물을 이용하여, 인체조직등가 팬톰을 제작한 후 자궁경부암의 자궁강내 근접 방사선조사를 시행하는 것과 똑같이 Fletcher-Suit-Delclos applicator 를 삽입하였다. Tandem 에 $15.7mg\;Ra-eq$의 방사능을 가진 $^{137}Cs$ tube를 2cm 간격으로 3개 주입한 후, A점에 해당되는 단면에 수직방향과 평행방향으로 각각 필름을 팬톰 간극에 삽입하였고, 또한 팬톰표면의 방사선량분포측정을 위하여 팬톰표면을 필름으로 감싸서, 1시간 조사하였다. 필름에 현상된 음영을 필름농도계를 이용하여 농도분포를 측정하여, A점에 대한 방사선량을 환산하였고, 전체적인 선량분포도를 얻었다. 이러한 측정값과 전산화치료계획장치를 이용하여 얻은 A점 값, along-away 표에 의한 A점 선량을 비교하였고, 필름에 의한 선량분포와 컴퓨터에 의한 선량분포를 서로 비교하였다. 결과 : A점에 대한 필름 측정치는 시간당 51.2cGy였고, 전산화치료계획장치에 의한 계산값은 시간당 46.7cGy, along-away 표에 의한 값은 시간당 47.9 cGy여서 약 10% 이내로 비교적 일치하였다. 필름을 계측하여 얻은 선량분포와 전산화치료계획장치의 계산에 의한 선량분포는 비슷한 모습을 보여 주었다. 결른 : 본 연구에서 아크릴과 물을 이용하여, 간단하고 경제적인 방법으로 인체조직등가팬톰을 제작할 수 있었고, 이러한 간단한 팬톰을 이용하여 비교적 효과적으로 자궁강내 근접 방사선조사시 사용하는 밀봉선원인 $^{137}Cs$ tube 의 선량에 대한 품질검사는 물론, 전산화치료계획장치를 이용한 값과 이론적인 식을 바탕으로 수작업으로 계산한 값, 그리고 실험으로부터 구한 실측값을 비교 검토함으로써 치료계획의 신뢰성을 확인할 수 있었다.

  • PDF

Transmission Dose Estimation Algorithm for in vivo Dosimetry

  • Yun, Hyong-Geun;Huh, Soon-Nyung;Lee, Hyoung-Koo;Woo, Hong-Gyun;Shin, Kyo-Chul;Ha, Sung-Whan
    • Journal of Radiation Protection and Research
    • /
    • 제28권1호
    • /
    • pp.59-63
    • /
    • 2003
  • Purpose : Measurement of transmission dose is useful for in vivo dosimetry of QA purpose. The objective of this study is to develope an algorithm for estimation of tumor dose using measured transmission dose for open radiation field. Materials and Methods : Transmission dose was measured with various field size (FS), phantom thickness (Tp), and phantom chamber distance (PCD) with a acrylic phantom for 6 MV and 10 MV X-ray Source to chamber distance (SCD) was set to 150 cm. Measurement was conducted with a 0.6 cc Farmer type ion chamber. Using measured data and regression analysis, an algorithm was developed for estimation of expected reading of transmission dose. Accuracy of the algorithm was tested with flat solid phantom with various settings. Results : The algorithm consisted of quadratic function of log(A/P) (where A/P is area-perimeter ratio) and tertiary function of PCD. The algorithm could estimate dose with very high accuracy for open square field, with errors within ${\pm}0.5%$. For elongated radiation field, the errors were limited to ${\pm}1.0%$. Conclusion : The developed algorithm can accurately estimate the transmission dose in open radiation fields with various treatment settings.