• Title/Summary/Keyword: Radiation Dose Rate

Search Result 1,257, Processing Time 0.029 seconds

Dose Rate of Restroom in Facilities using Radioisotope (방사성동위원소 사용시설(내/외) 화장실의 외부선량률)

  • Cho, Yong-Gwi;An, Seong-Min
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.237-246
    • /
    • 2016
  • This study is therefore aimed at measuring the surface dose rate and the spatial dose rate in and outside the radionuclide facility in order to ensure safety of the patients, radiation workers and family care-givers in their use of such equipment and to provide a basic framework for further research on radiation protection. The study was conducted at 4 restrooms in and outside the radionuclide facility of a general hospital in Incheon between May 1 and July 31, 2014. During the study period, the spatial contamination dose rate and the surface contamination dose rate before and after radiation use were measured at the 4 places-thyroid therapy room, PET center, gamma camera room, and outpatient department. According to the restroom use survey by hospitals, restrooms in the radionuclide facility were used not only by patients but also by family care-givers and some of radiation workers. The highest cumulative spatial radiation dose rate was 8.86 mSv/hr at camera room restroom, followed by 7.31 mSv/hr at radioactive iodine therapy room restroom, 2.29 mSv/hr at PET center restroom, and 0.26 mSv/hr at outpatient department restroom, respectively. The surface radiation dose rate measured before and after radiation use was the highest at toilets, which are in direct contact with patient's excretion, followed by the center and the entrance of restrooms. Unsealed radioactive sources used in nuclear medicine are relatively safe due to short half lives and low energy. A patient who received those radioactive sources, however, may become a mobile radioactive source and contaminate areas the patient contacts-camera room, sedation room, and restroom-through secretion and excretion. Therefore, patients administered radionuclides should be advised to drink sufficient amounts of water to efficiently minimize radiation exposure to others by reducing the biological half-life, and members of the public-family care-givers, pregnant women, and children-be as far away from the patients until the dose remains below the permitted dose limit.

Evaluation of Caregivers' Exposed Dose and Patients' External Dose Rate for Radioactive Iodine (I-131) Therapy Administration in Isolated Ward (방사성요오드(I-131) 격리병실 치료 관리를 위한 환자의 체외방사선량률과 상주 보호자의 피폭선량평가)

  • Kang, Seok-Jin;Lee, Doo-Hyeon;So, Young;Lee, Jeong-Woo
    • Journal of radiological science and technology
    • /
    • v.45 no.4
    • /
    • pp.347-353
    • /
    • 2022
  • In this study, the radiation dose rate was measured by time and distance and evaluated whether radiation dose rate was suitable for domestic and international discharge criteria. In addition, the radiation dose emitted from the patient was measured with a glass dosimeter to evaluate the exposure dose if the caregiver stays in the isolated ward by placing a humanoid phantom instead of the caregiver at a distance of 1 m from the patient, on the second day of treatment. After 23 hours of isolation, the radiation dose rates at a distance of 1 m were 20.54 ± 6.21 µSv/h at 2.96 GBq administration and 27.94 ± 12.33 µSv/h at 3.70 GBq administration. The radiation dose rates at a distance of 1 m were 25.90 ± 2.21 µSv/h when 2.96 GBq was administered and 34.22 ± 10.06 µSv/h when 3.70 GBq was administered after 18 hours of isolation. However, if the isolation period is short may cause unnecessary radiation exposure to the third person. The reading of the attached dosimeter from the morning of the second day of treatment until removal was 0.01 to 0.95 mSv, which is a surface dose determined by the International Commission on Radiation Units and Measurements. And the depth dose was 0.01 to 0.99 mSv. On the second day of treatment, even if the patient caregivers stayed in the isolation ward, the exposure dose of the patient family did not exceed the effective dose limit of 5 mSv recommended by the ICRP and NCRP.

Gamma Knife Radiosurgery for Vestibular Schwannomas

  • Lim, Young-Jin;Choi, Seok-Keun
    • Journal of Korean Neurosurgical Society
    • /
    • v.42 no.3
    • /
    • pp.159-167
    • /
    • 2007
  • Vestibular schwannoma (VS) is a benign tumor typically originated in the schwann cell of vestibular nerve and usually accompany hearing symptom. Microsurgical removal and radiosurgery have a great role for the treatment of VS. Recently radiosurgery has been considered as an alternative or primary treatment for VS with the tremendous increase of patients who were treated with gamma knife radiosurgery (GKS) though microsurgery still takes the premier. By many published results, it is proved that GKS is a effective and noninvasive technique for VS, especially small sized tumors with satisfactory tumor control rate. The authors assumed that GKS can be expected to achieve satisfactory tumor control rate for small VS under 5cc in volume. A major interest regarding radiosurgery nowadays is to determine the optimal radiation dose for hearing preservation to improve the quality of life of patients. The more high radiation dose are used for effective tumor growth control, the more radiation-related complications like as hearing deficit, the impairment of other cranial nerve function are increased. Since 1990's the mean radiation dose for tumor margin was more than 18 Gy, but there were high complication rate in spite of good tumor growth control. After the year of 2000, under the influence of advanced neuro-imaging techniques and radiosurgical planning system which enable clinicians to do more precise planning, marginal dose for VS has been decreased to 12-13 Gy and the radiation-related complications has been reduced. But because there may be a unexpected radiation induced complications as time goes by after the latency period, optimal radiation dose for VS should be established on the basis of more long term follow-up observation.

Effect of Low Dose of Gamma Radiation on the Growth of Groundnut (Arachis hypogaea L.) (저선량 감마선이 땅콩 생장에 미치는 효과)

  • 김재성;이은경;백명화;박홍숙;김광호
    • Korean Journal of Environmental Biology
    • /
    • v.17 no.3
    • /
    • pp.257-261
    • /
    • 1999
  • Effect of low dose gamma radiation on the growth of groundnut (Arachis hypognea L.) were investigated with respect to germination rate, seedling development and yield. Seeds of “Palpal” cultivar were irradiated with 0.5~20 Gy of ${\gamma}$ radiation in order to determine the hermetic effect of low dose radiation. The germination rate of ${\gamma}$-ray irradiation group was lower than that of the control but the seedling height of groundnut grown from seeds irradiated with low dose ${\gamma}$-ray was slightly higher than that of the control. The number of pod and kernels, and the seed yield increased by 27%, 17% and 19 %, respectively, in the 12.0 Gy irradiation group compared to that in the control group. The 100 seed weight was 87.2 g in the 4.0 Gy irradiation group, which was 11% heavier than 78.3 g in the control group. Low dose radiation showed an enhancement effects on the growth and yield components of groundnut.

  • PDF

Sensitivity of Lavender to Proton, Electron, and Gamma Radiation

  • Chen, Wensheng;Li, Hui;Shi, Lei;Bai, Hong Tong
    • Horticultural Science & Technology
    • /
    • v.34 no.1
    • /
    • pp.122-133
    • /
    • 2016
  • While ion beams are widely used in plant breeding, little is known about the sensitivity of Lavandula angustifolia (lavender) to ionizing radiation. To compare the biological effects of different types of ionizing radiation on the germination and survival rates of lavender, we exposed lavender seeds to gamma rays, 3 MeV electron beams, and 1.89 MeV proton ion beams. We observed that the seed germination rate decreased with increasing dosages of all three types of ionizing radiation. The malformation rate of lavender seedlings exposed to electron beams and gamma rays increased with increasing radiation dosage. By contrast, the effect of the accelerated proton beams on the malformation rate was negatively correlated with the dosage used. The survival rate of lavender seedlings exposed to the three types of ionizing radiation decreased in a dose-dependent manner. In addition, the survival rate of seedlings irradiated with proton and electron beams decreased more slowly than did that of seedlings irradiated with gamma rays. The half-lethal dose of gamma rays, electron beams, and proton beams was determined to be 48.1 Gy, 134.3 Gy, and 277.8 Gy, respectively, and the most suitable proton-ion energy for lavender seeds in terms of penetration depth was determined to be 5 MeV. These findings provide valuable information for the breeding of lavender by radiation mutation.

Albumin-Crosslinked PVP Hydrogel as a Gastric Retention Platform (위내체류를 목적으로 한 알부민 가교 PVP 하이드로겔의 팽윤특성)

  • Shim, Chang-Koo;Yeo, So-Hyeon
    • Journal of Pharmaceutical Investigation
    • /
    • v.23 no.3
    • /
    • pp.145-153
    • /
    • 1993
  • Retaining a drug in the stomach by some means is sometimes necessary to extend the G1 absorption time of the drug more than 6-8 hrs. Hydrogel has often been examined for its feasibility as a dosage form, so called platform, that could be retained in the stomach due to its excellent swelling properties in the gastric fluid. In this study, polyvinylpyrrolidone (PVP) hydrogel crosslinked by albumin or acrylated albumin was synthesized in a tablet form and evaluated for its possibility as the platform. The synthesis of the hydrogel was performed by $^{60}Co\;{\gamma}-ray$ irradiation of N-vinyl-2-pyrrolidone (monomer) in the presence of a crosslinking agent: aqueous solution of albumin or acrylated albumin. Synthetic conditions such as radiation dose, dose rate and concentration of crosslinking agent were varied in order to optimize the swelling and mechanical properties of the hydrogels. Degree of swelling of albumin-crosslinked PVP (Al-PVP) was highly dependent on radiation dose, dose rate and albumin concentration: it was decreased as they increased. On the other hand, that of acrylated albumin-crosslinked PVP (Acryl-PVP) was almost independent on them except dose rate: it was decreased as the radiation dose rate increased. The compressive strength of the two hydrogels was decreased as the dose rate increased. Digestion of both PVP in artificial gastric fluid containing pepsin was delayed by the ${\gamma}-ray$ irradiation. In conclusion, Al-PVP and Acry-PVP with diverse swelling and mechanical properties could be obtained by controlling synthetic conditions, mainly the irradiation dose rate.

  • PDF

Solution to Decrease Spatial Dose Rate in Laboratory of Nuclear Medicine through System Improvement (시스템 개선을 통한 핵의학 검사실의 공간 선량률 감소방안)

  • Moon, Jae-Seung;Shin, Min-Yong;Ahn, Seong-Cheol;Yoo, Mun-Gon;Kim, Su-Geun
    • Quality Improvement in Health Care
    • /
    • v.20 no.1
    • /
    • pp.60-73
    • /
    • 2014
  • Objectives: This study aims at decreasing spatial dose rate through work improvement whilst spatial dose rate is the cause of increasing personal exposure dose which occurs in the process of handling radioisotope. Methods: From February 2013 until July 2013, divided into "before" and "after" the improvement, spatial dose rate in laboratory of nuclear medicine was measured in gamma image room, PET/CT-1 image room, and PET/CT-2 image room as its locations. The measurement time was 08:00, 12:00 and 17:00, and SPSS 21.0 USA was opted for its statistical analysis. Result: The spatial dose rate at distribution worktable, injection table, the entrance to the distribution room, and radioisotope storage box, which had showed high spatial dose rate, decreased by more than 43.7% a monthly average. The distribution worktable, that had showed the highest spatial dose rate in PET/CT-1 image room, dropped the rate to 42.3% as of July. The injection table and distribution worktable in the PET/CT-2 image room also showed the decline of spatial dose rate to 89% and 64.4%, respectively. Conclusion: By improving distribution process and introducing proper radiation shielding material, we were able to drop the spatial dose rate substantially at distribution worktable, injection table, and nuclide storage box. However, taking into account of steadily increasing amount of radioisotope used, strengthening radiation related regulations, and safe utilization of radioisotope, the process of system improvement needs to be maintained through continuous monitoring.

The impact of radiotherapy on clinical outcomes in parameningeal rhabdomyosarcoma

  • Choi, Yunseon;Lim, Do Hoon
    • Radiation Oncology Journal
    • /
    • v.34 no.4
    • /
    • pp.290-296
    • /
    • 2016
  • Purpose: Radiotherapy (RT) is considered a mainstay of treatment in parameningeal rhabdomyosarcoma (PM-RMS). We aim to determine the treatment outcomes and prognostic factors for PM-RMS patients who treated with RT. In addition, we tried to evaluate the adequate dose and timing of RT. Materials and Methods: Twenty-two patients with PM-RMS from 1995 to 2013 were evaluated. Seven patients had intracranial extension (ICE) and 17 patients had skull base bony erosion (SBBE). Five patients showed distant metastases at the time of diagnosis. All patients underwent chemotherapy and RT. The median radiation dose was 50.4 Gy (range, 40.0 to 56.0 Gy). Results: The median follow-up was 28.7 months. Twelve patients (54.5%) experienced failure after treatment; 4 local, 2 regional, and 6 distant failures. The 5-year local control (LC) and overall survival (OS) were 77.7% and 38.5%, respectively. The 5-year OS rate was 50.8% for patients without distant metastases and 0% for patients with metastases (p < 0.001). Radiation dose (<50 Gy vs. ${\geq}50Gy$) did not compromise the LC (p = 0.645). However, LC was affected by ICE (p = 0.031). Delayed administration (>22 weeks) of RT was related to a higher rate of local failure (40.0%). Conclusion: RT resulted in a higher rate of local control in PM-RMS. However, it was not extended to survival outcome. A more effective treatment for PM-RMS is warranted.

Survival and Complication Rate of Radiation Therapy in Stage I and II Carcinoma of Uterine Cervix (병기 I, II 자궁 경부암에서 방사선치료 후 생존율 및 합병증 분석)

  • Ma, Sun-Young;Cho, Heung-Lea;Sohn, Seung-Chang
    • Radiation Oncology Journal
    • /
    • v.13 no.4
    • /
    • pp.349-357
    • /
    • 1995
  • Purpose : To analyze survival rate and late rectal and bladder complication for patients with stage I and II carcinoma of uterine cervix treated by radiation alone or combined with chemotherapy Materials and Methods : Between November 1984 and December 1993, 127 patients with stage I and II carcinoma of uterine cervix treated by radiation alone or combined therapy of radiation and chemotherapy. Retrospective analysis for survival rate was carried out on eligible 107 patients and review for complication was possible in 91 patients. The median follow-up was 47 months (range 3-118) and the median age of patiens was 56 years (range 31-76). 26 patients were stage IB by FIGO classification, 40 were stage IIA and 41 were stage IIB. 86 cases were treated by radiation alone and 21 were treated by radiation and chemotherapy. 101 patients were treated with intracavitary radiation therapy (ICRT), of these, 80 were received low dose rate (LDR) ICRT and 21 were received high dose rate (HDR) ICRT. Of the patients who received LDR ICRT, 63 were treated by 1 intracavitary insertion and 17 were underwent 2 insertions And we evaluated the external radiation dose and midline shield. Results : Actuarial survival rate at 5 years was $92{\%}$ for stage IB, $75{\%}$ for stage IIA, $53{\%}$ for stage IIB and $69{\%}$ in all patients Grade 1 rectal complications were developed in 20 cases ($22{\%}$), grade 2 were in 22 cases ($24{\%}$). 22 cases ($24{\%}$) of grade 1 urinary complications and 17 cases ($19{\%}$) of grade 2 urinary complications were observed But no patient had severe complications that needed surgical management or admission care. Maximum bladder dose for the group of patients with urinary complications was higher than that for the patients without urinary complications (7608 cGy v 6960cGy. p<0.01) Maximum rectal dose for the group of patients with rectal complications was higher than that for the patients without rectal complications (7041cGy v 6269cGy, p<0.01). While there was no significant difference for survival rate or bladder complication incidence as a function of dose to whole pelvis, Grade 2 rectal complication incidence was significantly lower for the patients receiving less than 4500cGy ($6.3{\%}$ v $25.5{\%}$, p<0.05). There was no significant differance between HDR ICRT group and LDR ICRT group for survival rate according to stage, on the other hand complication incidence was higher in the HDR group than LDR group, This was maybe due to different prescription doses between HDR group and LDR group. Midline shield neither improved survival rate nor decreased complication rate. The number of insertion in LDR ICRT group did not affect on survival and compication rate. Conclusion : In stage I and II carcinoma of uterine cervix there was no significant differance for 5 year survival rate by radiation therapy technique. Rectal complication incidence was as a function of dose to whole pelvis and there were positive correlations of maximum dose of rectum and bladder and each complication incidence. So we recommand whole pelvis dose less than 4500cGy and maximum dose of rectum and bladder as low as possible.

  • PDF