• 제목/요약/키워드: Radiant Intensity

Search Result 40, Processing Time 0.024 seconds

Spectral Infrared Signature Analysis of the Aircraft Exhaust Plume (항공기 배기 플룸의 파장별 IR 신호 해석)

  • Gu, Bonchan;Baek, Seung Wook;Yi, Kyung Joo;Kim, Man Young;Kim, Won Cheol
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.42 no.8
    • /
    • pp.640-647
    • /
    • 2014
  • Infrared signature of aircraft exhaust plume is the critical factor for aircraft survivability. To improve the military aircraft survivability, the accurate prediction of infrared signature for the propulsion system is needed. The numerical analysis of thermal fluid field for nozzle inflow, free stream flow, and plume region is conducted by using the in-house code. Weighted Sum of Gray Gases Model based on Narrow Band with regrouping is adopted to calculate the spectral infrared signature emitted from aircraft exhaust plume. The accuracy and reliability of the developed code are validated in the one-dimensional band model. It is found that the infrared radiant intensity is relatively more strong in the plume through the analysis, the results show the different characteristic of the spectral infrared signature along the temperature, the partial pressure, and the species distribution. The continuous spectral radiant intensity is shown near the nozzle exit due to the emission from the nozzle wall.

Evaluation of the Radiant Heat Effects according to the Change of Wind Velocity in Forest Fire by using WFDS (WFDS를 이용한 풍속에 따른 산림화재 복사열 강도 평가)

  • Song, Dong-Woo;Lee, Su-Kyung
    • Fire Science and Engineering
    • /
    • v.27 no.3
    • /
    • pp.1-7
    • /
    • 2013
  • The wildland fire intensity and scale are getting bigger owing to climate change in the world. In the case of domestic, the forest is distributed over approximately 63.7 % of country and the main facilities like a industrial facility or gas facility abuts onto it. Therefore there is potential that the wildland fire is developed to a large-scale disaster. In this study, the effect distances of the radiant heat flux from the crown fire are analysed according to the change of wind velocity. The safety criteria concerning the radiant heat flux to influence on the surrounding were researched to analyse the effect distances. The criteria of radiant heat flux were chosen $5kW/m^2$, $12.5kW/m^2$, $37.5kW/m^2$. WFDS, which is an extension of NIST's Fire Dynamics Simulator, was used to consequence analysis of the forest fire. In order to apply the analysis conditions, it is researched the forest conditions that is generally distributed in domestic region. As the result, the maximum effect distances by radiant heat were showed at the horizontal and vertical direction. When the wind velocity varied from 0 to 10 m/s, the maximum effect distance increased as the wind velocity increases. Interesting point is that the maximum effect distance were shown at the wind velocity of 8 m/s. The maximum effect distance was decreased according as the fuel moisture of trees increase. This study can contribute to analyse quantitative risk about the damage effect of the surrounding facilities caused by wildland fire.

A Feasibility Study on the Probabilistic Method for the Naval Ship Infra-red Signature Management (함정적외선신호 관리를 위한 확률론적 방법의 가능성 연구)

  • Park, Hyun-jung;Kang, Dae-soo;Cho, Yong-jin
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.56 no.5
    • /
    • pp.383-388
    • /
    • 2019
  • It is essential to reduce the Infra-red signature for increasing ship's survivability in ship design stage. However the ship's IR signature is quite sensitive to the maritime and atmosphere. Therefore, it is very important to select the marine meteorological data to be applied to the signature analysis. In this study, we selected the three meteorological sample sets from the population of the Korea Meteorological Administration's marine environment data in 2017. These samples were selected through the two-dimensional stratified sampling method, taking into account the geopolitical threats of the Korean peninsula and the effective area of the buoy. These sample sets were applied to three naval ships classified by their tonnage, and then the IR signature analysis was performed to derive the Contrast Radiant Intensity (CRI) values. Based on the CRI values, the validity of each sample set was determined by comparing Cumulative Distribution Function (CDF), and Probability Density Function (PDF). Also, we checked the degree of scattering in each sample set and determined the efficiency of analysis time and cost according to marine meteorological sample sets to confirm the possibility of a probabilistic method. Through this process, we selected the standard for optimization of marine meteorological sample for ship IR signature analysis. Based on this optimization sample, by applying probabilistic method to the management of IR signature for naval ships, the robust design is possible.

Infrared Signature Analysis on Armored Vehicle Applied with Emissivity Controlled Structure (장갑 차량의 방사율 제어구조 적용에 따른 적외선 신호 분석)

  • Kim, Taeil;Kim, Taehwan;Bae, Ji-Yeul;Jung, Daeyoon;Cho, Hyung Hee
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.30 no.2
    • /
    • pp.179-184
    • /
    • 2017
  • Due to rapid development of infrared guided weapon, survivability of armored vehicle is severely threatened. Hence, reduction of susceptibility by lowering infrared signature level is essential to enhance survivability of the vehicle. For this purpose, numerical analysis is conducted to analyze time and spatial characteristics of infrared signature of the vehicle when surface emissivity changes in this study. The analysis shows that the emissivity which produces minimum contrast radiant intensity is significantly altered by time and detecting position. Based on the result, it is concluded that the controlled structures which have different emissivity should be adopted at different region of the vehicle to effectively decrease infrared signature level.

A Discussion on the Radiation Efficiency Measurement of Porous Surface Flames (다공성 표면 화염의 복사열효율측정에 관한 논의)

  • Jeong, Hwanghui;Sim, Keunseon;Lee, Keeman
    • 한국연소학회:학술대회논문집
    • /
    • 2014.11a
    • /
    • pp.157-159
    • /
    • 2014
  • This article describes an investigation of basic combustion characteristics of radiant burner with various firing rate and equivalence ratios in porous metal. As a main experimental condition, firing rates and equivalence ratios each were adjusted from 204 to $408kW/m^2$ and 0.6 to 1.3. The purpose of this study is to investigate radiation efficiency using two experiment methods. The first way is to calculate the radiation efficiency by measuring the temperature of the burner surface, and the second is to compute the radiation efficiency by measuring the radiation intensity of the burner surface with a radio meter. The value of the radiation efficiency did not exactly match in the two cases. But we figured out that in accordance with increasing heat power, radiation efficiency was decreased. And additional complementary experiment on the relationship between these values is needed.

  • PDF

Experimental Analysis of Radiative Heat Interchange on Furnace Exit Plane of a Steam Boiler

  • Ahn, Kook-Young;Antonovsky, Vjacheslav-Ivanovich
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.2
    • /
    • pp.239-247
    • /
    • 2001
  • Measured radiative heat fluxes on the furnace exit plane of a heavy duty power boiler of steam output 1650 T/h are discussed. A high-ash pulverized bituminous coal was used. Such measurements are necessary to improve heat fluxes inside a steam boiler furnace was manufactured. An extra small heat radiation sensor was placed in the water cooled head of the probe. The sensor had no direct contact with furnace gases and measured only the radiant energy. There was no exposure to convective heat transfer. With the radiometric probe, one can obtain a spherical indicatrix of radiation intensity as well as hemispherical radiative heat flux incident on any surface passing through a measuring point inside the furnace. Thus, the quantity of radiation energy, passing through the furnace exit plane, to the convective heating surfaces and the quantity of radiation energy going in the opposite direction were measured. A formula for relative radiative heat flux on the furnace exit plane has been proposed.

  • PDF

Investigation on Numerical Integration for Radiation Heat Transfer in Radiating Fluid (복사유체의 복사열전달 수치 적분에 관한 연구)

  • Han Cho Young
    • Journal of computational fluids engineering
    • /
    • v.9 no.2
    • /
    • pp.43-51
    • /
    • 2004
  • Interaction between fluid flow and thermal radiation has received considerable attention due to its numerous applications in engineering field. In this case the thermofluid properties of radiating fluid vary with the variation of temperature field caused by absorption and emission of radiant heat. To analyze the radiation heat transfer in radiating fluid, the simultaneous solution of the radiative transfer equation (RTE) and the fluid dynamics equations is required. This means that the numerical procedure used for the RTE must be computationally efficient to permit its inclusion in the other submodels, and must be compatible with the other transport equations. The finite volume method (FVM) and the discrete ordinates method (DOM) are usually employed to simulate radiation problems in generalized coordinates. These two representative methods are examined and compared, especially in view of the numerical integration of the radiation intensity over solid angle. The FVM shows better accuracy than the DOM owing to less constraints of the selection of control angle.

Investigation on Numerical Integration for Radiation Heat Transfer in Radiating Fluid (복사유체의 복사열전달 수치 적분에 관한 연구)

  • Han Cho Young
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2004.03a
    • /
    • pp.62-70
    • /
    • 2004
  • Interaction between fluid flow and thermal radiation has received considerable attention due to its numerous applications in engineering field. In this case the thermofluid properties of radiating fluid vary with the variation of temperature field caused by absorption and emission of radiant heat. To analyze the radiation heat transfer in radiating fluid, the simultaneous solution of the radiative transfer equation (RTE) and the fluid dynamics equations is required. This means that the numerical procedure used for the RTE must be computationally efficient to permit its inclusion in the other submodels, and must be compatible with the other transport equations. The finite volume method (FVM) and the discrete ordinates method (DOM) are usually employed to simulate radiation problems in generalized coordinates. These two representative methods are examined and compared, especially in view of the numerical integration of the radiation intensity over solid angle. The FVM shows better accuracy than the DOM owing to less constraints of the selection of control angle.

  • PDF

UV/IR flame detector using Microprocessor (마이크로프로세서를 사용한 UV/IR 불곶 감지기)

  • 박성진;임병현;임종연;김명원;윤길호
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.215-218
    • /
    • 2001
  • A flame detector responds either to radiant energy visible to the human eye or outside the range of human vision. Such a detector is sensitive to glowing embers, coals, or flames which radiate energy of sufficient intensity and spectral quality to actuate the alarm. An infra-red detectors can respond to the total IR component of the flame alone or in combination with flame flicker in the frequency range of 5 to 30 Hz. A major problem in the use of infrared detectors receiving total IR radiation is the possible interference of solar radiation in the infrared region. When detectors are located in places shielded from the sun, such as vaults. filtering or shielding the unit from the sun's rays is unnecessary. In this study, we proposed method for redue a false alarm with using filtering & sensor technology for distinguish of causes of raise a false alarm and pure flame.

  • PDF

A Comparative Study between Measurement and Prediction Results of a Naval Ship Infrared Signature in the Marine Environment (해상환경에서 함정 적외선 신호 측정 및 예측결과 비교 분석 연구)

  • Kim, Jung-Ho;Yoon, Yoon-Sik
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.48 no.4
    • /
    • pp.336-341
    • /
    • 2011
  • Ship infrared signature is the cause of detection and tracking by infrared sensor and anti-ship missile seeker. Recent warships have been applied the infrared stealth technology to reduce own ship infrared signature and tested to validate own ship infrared signature level. This study describes the two issues. Firstly, we describe the infrared measurement concept and infrared signature level establishment method that have been performed. Secondly, we compare and analyze the error components between the infrared measurement and simulation result.