• Title/Summary/Keyword: Radial motion

Search Result 305, Processing Time 0.027 seconds

Dynamic behavior of a scroll compressor with radial compliance device (반경방향 순응기구를 갖는 스크롤 압축기의 동적 거동)

  • 김현진;김재호;이진갑
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.1
    • /
    • pp.33-43
    • /
    • 1998
  • Dynamic behavior of a scroll compressor has been investigated analytically. The equations of motion of moving elements of the scroll compressor such as the orbiting scroll, anti-rotation device, slider bush, and the crank shaft with eccentric crank pin have been set up. As the solutions of these equations, reaction forces between the moving elements, and also between the moving elements and the compressor frame have been calculated. The reaction forces from the moving elements to the frame are the unbalanced forces, which produce accelerations of the compressor body. These accelerations can be used as a measure of the compressor vibration. The major contributions to the unbalanced forces come from the orbiting movement of the orbiting scroll.

  • PDF

Numerical Analysis of Tip Clearance Effects in a Micro Radial Inflow Turbine

  • Watanabe, Naoki;Teramoto, Susumu;Nagashima, Toshio
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.03a
    • /
    • pp.622-627
    • /
    • 2004
  • There are many difficulties in realizing Ultra-micro gas turbine system. Among them, the effects of tip clearance upon the micro turbine flowfield are discussed in this paper. The flowfield was investigated numerically with the Reynolds-averaged three-dimensional thin-layer Navier-Stokes equations. Calculations were conducted with clearance height from 0% to 10% of the passage height. Leakage mass flow and deterioration of efficiency are proportional to the clearance height for the clearance height larger than 4%. However, in the case of 2% clearance, leakage flow is significantly reduced due to relative motion of the casing and as a result deterioration of efficiency is very small. It is difficult to control tip clearance in micro turbines, but the results of this study indicate that if the clearance height is controlled within a few per-cent of passage height, deterioration of stage performance will be small.

  • PDF

Motion-compensated Radial Representation-based Real-Time Object Tracking (움직임 보상한 방사상 표현 기반 실시간 객체 추적)

  • Ra, Jeong-Jung;Seo, Kyung-Seok;Choi, Heung-Moon
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2004.05a
    • /
    • pp.719-722
    • /
    • 2004
  • 객체 중심점에서 움직임을 추정하고 보상하여 빠르게 움직이는 객체의 윤곽선을 실시간으로 추적 할 수 있는 알고리듬을 제안하였다. 방사상 표현 (radial representation) 방식을 적용하여 객체 중심점에서만 블록정합 (block matching) 알고리듬으로 움직임을 추정하고 보상하여 적은 계산량으로 객체 움직임을 추정하고 보상함으로써 객체 윤곽선을 실시간으로 추적하였다. 에너지 수렴 과정에서 기울기 영상과 차영상 (differential image)을 에너지 함수로 함께 사용함으로 배경 잡영 등에도 강건하도록 하였다. 실험 결과 움직임이 빠른 객체와 배경 잡영 속의 객체도 실시간으로 강건하게 추적함을 확인하였다.

  • PDF

The Effect of Casing Geometry on Rotordynamic Fluid Forces on a Closed Type Centrifugal Impeller in Whirling Motion

  • Richert, Julien;Nishiyama, Yumeto;Hata, Shinichiro;Horiguchi, Hironori;Tsujimoto, Yoshinobu
    • International Journal of Fluid Machinery and Systems
    • /
    • v.4 no.2
    • /
    • pp.217-222
    • /
    • 2011
  • The rotordynamic fluid forces acting on a closed type impeller in whirling motion were measured and the influence of the clearance geometry on the stability of the impeller was examined. At small positive whirling speed, the rotordynamic forces acted as destabilizing forces for all casings. A small clearance between the shroud of the impeller and the casing caused large fluid force, but did not change the destabilizing region. Radial grooves in the clearance were effective for reducing the fluid forces and destabilizing region due to the reduction of the circumferential velocity without the deterioration of the pump performance. A rotating phenomenon like a rotating stall of the impeller occurred at low flow rate and the resonance between it and the whirling motion led to a sudden increase in force at the whirling speed ratio of 0.7.

Moving load induced dynamic response of functionally graded-carbon nanotubes-reinforced pipes conveying fluid subjected to thermal load

  • Tahami, F. Vakili;Biglari, H.;Raminnea, M.
    • Structural Engineering and Mechanics
    • /
    • v.64 no.4
    • /
    • pp.515-526
    • /
    • 2017
  • Dynamic response of functionally graded Carbon nanotubes (FG-CNT) reinforced pipes conveying viscous fluid under accelerated moving load is presented. The mixture rule is used for obtaining the material properties of nano-composite pipe. The radial force induced by viscous fluid is calculated by Navier-Stokes equation. The material properties of pipe are considered temperature-dependent. The structure is simulated by Reddy higher-order shear deformation shell theory and the corresponding motion equations are derived by Hamilton's principal. Differential quadrature (DQ) method and the Integral Quadrature (IQ) are applied for analogizing the motion equations and then the Newmark time integration scheme is used for obtaining the dynamic response of structure. The effects of different parameters such as boundary conditions, geometrical parameters, velocity and acceleration of moving load, CNT volume percent and distribution type are shown on the dynamic response of pipe. Results indicate that increasing CNTs leads to decrease in transient deflection of structure. In accelerated motion of the moving load, the maximum displacement is occurred later with respect to decelerated motion of moving load.

Effects of Immersive Virtual Reality Intervention on Upper Extremity Function in Post-Stroke Patients (몰입형 가상현실 프로그램 Rapael Smart Glove가 뇌졸중 환자의 상지기능에 미치는 영향)

  • Bae, Wonjin;Kam, Kyungyoon
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.5 no.3
    • /
    • pp.1-9
    • /
    • 2017
  • Purpose: The purpose of this study was to investigate the effects of an immersive, virtual reality-based exercise program on range of motion and dexterity in the upper extremities of stroke patients. Methods: Fifteen patients with hemiparesis after stroke participated in this study. The participants participated in Rapael Semart GloveTM, an immersive, virtual reality-based exercise program, performed for 30 minutes-, 3 times per week for 4 weeks. The Rapael Smart GloveTM program and a Box and Block Test (BBT) were used to measure range of motion and to assess dexterity, respectively, pre-and post-intervention. Results: Range of motion in pronation and supination of the forearm and flexion, extension, and ulnar deviation of the wrist improved after the intervention. Dexterity measured by BBT also improved. However, range of motion in flexion and extension of the fingers and radial deviation of the wrist did not improve. Conclusion: This study presents the effects of an immersive, virtual reality-based exercise program on hand function. In the future, a study comparing an immersive, virtual reality- based exercise program to other upper-extremity interventions for stroke patients should be conducted. A study about the effects of an immersive virtual reality program on activities of daily living is also needed.

Anterior Dislocation of the Radial Head Combined with Plastic Deformity of the Ulnar Shaft in an Adult: A Case Report

  • Moon, Sang Won;Kim, Youngbok;Kim, Young-Chang;Kim, Ji-Wan;Yoon, Taiyeon;Kim, Seung-Chul
    • Clinics in Shoulder and Elbow
    • /
    • v.21 no.1
    • /
    • pp.42-47
    • /
    • 2018
  • A 25-year-old woman presented to the emergency room with a painful and swollen right forearm. She had just sustained an injury from an accident during which her arm was tightly wound by a rope as she was lowering a net from a fishing boat. Before being released, her arm was rigidly trapped in the rope for approximately ten minutes. Radiographs revealed anterior dislocation of the radial head that was accompanied by plastic deformation of the proximal ulna, manifested as a reversal of the proximal dorsal angulation of the ulna (PUDA); suggested a Monteggia equivalent fracture. With the patient under general anesthesia, we reduced the radial head by posterior compression at $90^{\circ}$ of elbow flexion and at neutral rotation of the forearm. However, the reduction was easily lost and the elbow re-dislocated with even slight supination or extension of the arm. After the osteotomy of the ulnar deformity to restore the PUDA to normal, the reduction remained stable even with manipulation of the arm. We found that the patient could exercise a full range of motion without pain at the 3-month follow-up, and neither residual instability nor degenerative changes were observed at the final 3-year follow-up.

Surgical Correction of Hexadactyly: Innovation of new technique and its application (여섯 손가락증의 수술적 교정: 새로운 수술 방법의 고안과 적용)

  • Tark, Kwan Chul;Lee, Myung Chul
    • Archives of Plastic Surgery
    • /
    • v.36 no.5
    • /
    • pp.642-648
    • /
    • 2009
  • Purpose: Hexadactyly without thumb is a rare congenital anomaly of the hand where six triphalangeal digits are symmetrically distributed without thumb. Contrary to mirror hands, triphalangeal six digits are symmetrically distributed on each side at the midline with well - differentiated carpal bones, extensor tendons, one ulnar and one radius. The authors developed a new surgical technique based on a three - dimensional concept to correct the hexadactyly and applied to 2 cases of hexadactyly with good functional and aesthetic results. Here we document the surgical technique and its result. Methods: A 16 month old male patient visited our clinic with chief complaints of bilateral hexadactyly deformity. On physical examination most radial first and second digits showed no opposition and adduction motion on both side hands. Radiography showed 6 triphalangeal digits with normal development of carpal, radial and ulnar bone. Right side abnormality was corrected by removal of most radial side extra - digit, rotation and migration of 2nd ray to thumb position and creation of 1st web by transposing a mid - palm based rectangular palmar flap as in Snow & Littler procedure which has been being applied for correction of 1st web syndactyly in cleft hand deformity. Seven months later, left side abnormality was also corrected with the same procedure. Results: Postoperative appearances of the both hands were satisfactory. Flexion, extension, opposition and grasping were possible with the pollicized 2nd ray. Pinching power was 3.0 kg 15 months after surgery and 2.5 kg 22 months after in right hand respectively. Conclusion: In correction of hexadactyly deformity, satisfactory aesthetic and relevant functional results can be expected with authors' newly developed technique: removal of most radial digit, rotation and migration of 2nd digit to thumb position as well as creation of the 1st web space by transposition of mid - palm based rectangular flap.

Applying Focused and Radial Shock Wave for Calcific Tendinitis of the Shoulder : Randomized Controlled Study

  • Kim, Jonggun;Oh, Changmin;Yoo, John;Yim, Jongeun
    • Physical Therapy Rehabilitation Science
    • /
    • v.11 no.3
    • /
    • pp.356-362
    • /
    • 2022
  • Objective: Extracorporeal shock wave therapy (ESWT) is a nonsurgical treatment alternative to surgery for various musculoskeletal diseases that have traditionally been difficult to treat conservatively, including calcific tendinitis, tennis elbow, and plantar fasciitis. This study evaluated the effect of focused and radial shock wave therapy for calcific tendinitis of the shoulder. Design: Randomized controlled study Methods: Forty participants with calcific tendinitis were randomized into focused shock wave therapy (FSWT, n=20) and radial shock wave therapy (RSWT, n=20) groups. Patients were examined before and one week after treatment. Pain intensity was subjectively assessed using the visual analogue scale and function was assessed using the Constant-Murley score (CMS) and range of motion (ROM). Results: The results showed a significant decrease in pain and significant increase in shoulder mobility and function in both groups. However, FSWT was significantly more effective than RSWT, based on CMS and ROM assessment. Conclusions: Although it is possible to raise the energy intensity of RSWT to increase the depth at which the energy becomes dispersed, higher energy intensity is associated with a greater risk of severe neurovascular damage, and that high-intensity stimulation can cause adverse effects such as pain and petechiae. Therefore, FSWT is considered to be a safe and effective method for treating tendinous lesions while minimizing adverse effects. In conclusion, both FSWT and RSWT can reduce pain and increase mobility and function. FSWT can be considered as an alternative for calcific tendinitis of the shoulder.

Acutrak Screw Fixation for Radial Head Fracture -7 Cases Report- (Acutrak 나사를 이용한 요골두 골절의 치료 -7례 보고-)

  • Kim, Kwang-Yul;Lim, Moon-Sup;Shin, Heung-Sub;Choi, Shin-Kwon
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.5 no.1
    • /
    • pp.75-80
    • /
    • 2006
  • Purpose: To evaluate the efficiency of Acutrak screw fixation for radial head fracture (Mason type 2) without considering the safe Bone of radial head. Materials and Methods: Consecutive seven radial head fracture of Mason type II underwent internal fixation with Acutrak screws from May 2001 to February 2003. The mean follow-up period was 1.2years (ranged, $6 months{\sim}2.5 years$). The mean age of patients was 47 years old (ranged, $36{\sim}60years$ old). The cause of injury were fall down -4 cases and traffic accident -3 cases. The results were evaluated by Mayo Clinic results scoring system. Results: Functional Rating Index of Mayo Clinic was excellent- 2 cases and good- 5 cases. There were no nonunion, loosening, heterotopic ossification, infection or degenerative changes. The postoperative range of motion in elbow joint is nearly full for flexion, extension, pronation and supination in this study Conclusion: Consideration of safe zone is not necessary when Acutrak screws are used for radial head fracture. It seems to be a useful method that Acutrak screw fixation for radial head fracture (Mason type II) could achieve good radiologic and clinical results without influencing proximal radio-ulnar joint and has powerful fixation.

  • PDF