• Title/Summary/Keyword: Radial fracture

Search Result 144, Processing Time 0.024 seconds

Color Doppler Ultrasonographic Evaluation in Observing the Affects of $Osteoset^{(R)}$ on Radial Defects in Beagle Dogs (개에서 $Osteoset^{(R)}$의 요골 결손부 충진에 대한 색도플러초음파검사의 유용성 평가)

  • Jeon, Jong-Hoon;Seong, Yun-Sang;Eom, Ki-Dong;Kim, Jae-Hoon;Jang, Kwang-Ho
    • Journal of Veterinary Clinics
    • /
    • v.25 no.1
    • /
    • pp.1-8
    • /
    • 2008
  • This study is conducted to compare ultrasonographs with plain radiographs in monitoring bone regeneration during reconstruction of critical sized radial defects in dogs. A 15 mm bony defect was taken on each of the eight dog's radius using an electrical saw and an external fixator was applied. The experimental groups were divided into non-treated group(group 1) and $Osteoset^{(R)}$-treated group(group 2). Each fracture site was evaluated using plain radiography and ultrasonography. Radiographic callus formation occurred after $11.50{\pm}1.12$ days in group 1 and $11.50{\pm}0.5$ days in group 2. Neovascularized flow signal could be seen $6.50{\pm}1.5$ days and the vascular signal disappeared after $45.00{\pm}6.16$ days after operation in group 1. Neovascularized flow signal was observed $6.75{\pm}1.78$ days and vascular signal disappeared $23.25{\pm}3.03$ days after surgery which was caused by acoustic shadowing in group 2. Early stages of regeneration were observed more clearly with color Doppler ultrasonography than with plain radiography. Also from the results it is concluded that color Doppler ultrasonography are useful in observing initial stages of bone repair.

Prosthetic resurfacing of engaging posterior capitellar defects in recurrent posterolateral rotatory instability of the elbow

  • Dani Rotman;Jorge Rojas Lievano;Shawn W. O'Driscoll
    • Clinics in Shoulder and Elbow
    • /
    • v.26 no.3
    • /
    • pp.287-295
    • /
    • 2023
  • Background: Posterolateral rotatory instability (PLRI) is a common mechanism of recurrent elbow instability. While the essential lesion is a deficiency in the lateral ulnar collateral ligament (LUCL), there are often associated concomitant bony lesions, such as an Osborne-Cotterill lesions (posterior capitellar fractures) and marginal radial head fractures, that compromise stability. Currently, there is no standard treatment for posterior capitellar deficiency associated with recurrent PLRI. Methods: We conducted a retrospective review of five patients with recurrent PLRI of the elbow associated with a posterior capitellar impaction fracture engaging with the radial head during normal range of motion. The patients were treated surgically with LUCL reconstruction or repair and off-label reconstruction of the capitellar joint surface using a small metal prosthesis designed for metatarsal head resurfacing (HemiCAP toe classic). Results: Five patients (three adolescent males, two adult females) were treated between 2007 and 2018. At a median follow-up of 5 years, all patients had complete relief of their symptomatic instability. No patients had pain at rest, but two patients had mild pain (visual analog scale 1-3) during physical activity. Three patients rated their elbow as normal, one as almost normal, and one as greatly improved. On short-term radiographic follow-up there were no signs of implant loosening. None of the patients needed reoperation. Conclusions: Recurrent PLRI of the elbow associated with an engaging posterior capitellar lesion can be treated successfully by LUCL reconstruction and repair and filling of the capitellar defect with a metal prosthesis. This treatment option has excellent clinical results in the short-medium term. Level of evidence: IV.

EFFECT OF $CEO_2$ ADDITION IN GLASS COMPOSITION ON THE STRENGTH OF ALUMINA-GLASS COMPOSITES (알루미나-유리 복합체용 글래스의 조성에서 $CeO_2$의 함량변화가 강도에 미치는 영향)

  • Lee, Hwa-Jin;Song, Kwang-Yeob;Kang, Jeong-Kil
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.5
    • /
    • pp.595-605
    • /
    • 2000
  • Dental ceramics have good aesthetics, biocompatibility, low thermal conductivity, abrasion resistance, and color stability. However poor resistance to fracture and shrinkage during firing process have been limiting factors in their use, particularly in multiunit ceramic restorations. A new method for making all-ceramic crowns that have high strength and low processing shrinkage has been developed and is referred to as the Vita In-Ceram method. This study was performed to investigate the effect of $CeO_2$ addition in borosilicate glasses on the strength of alumina-glass composites. Porous alumina compacts were prepared by slip casting and sintered at $1,100^{\circ}C$ for 2 hours. Dense composites were made by infiltration of molten glass into partially sintered alumina at $1,140^{\circ}C$ for 4 hours. Specimens were polished sequentially from #800 to #2000 diamond disk. and the final surface finishing on the tensile side was received an additional polishing sequence through $1{\mu}m$ diamond paste. Biaxial flexure test was conducted by using ball-on-three-ball method at a crosshead speed of 0.5mm/min. To examine the microstructural aspect of crack propagation in the alumina-glass composites, Vickers-produced indentation crack was made on the tensile surface at a load of 98.0 N and dwell time of 15 sec, and the radial crack patterns were examined by an optical microscope and a scanning electron microscope. The results obtained were summarized as follows; 1. The porosity rates of partially sintered alumina decreased with the rising of firing temperature. 2. The maximum biaxial flexure strength of 423.5MPa in alumina-glass composites was obtained with an addition of 3 mol% $CeO_2$ in glass composition and strength values showed the aspect of decrease with the increase of $CeO_2$ content. 3 The biaxial flexure strength values of alumina-glass composites were decreased with rising the firing temperature. 4. Observation of the fracture surfaces of alumina-glass composites indicated that the enhancement of strength in alumina-glass composites was due to the frictional or geometrical inter-locking of rough fracture surfaces and ligamentary bridging by intact islands of materials left behind the fracture front.

  • PDF

Comparison of Three Surgical Method Outcomes for Dorsal Communition Distal Radial Fractures: External Fixation, External Fixation with Allogenous Bone Graft (DBM) and Volar Locking Plate Fixation (배측 분쇄가 있는 원위부 요골 관절내 골절의 3가지 수술적 치료 결과 비교: 외고정 기구 단독, 외고정 기구와 동종골이식 및 수장측 잠김 압박 금속판)

  • Choi, Joon-Cheol;Na, Hwa-Yeop;Lee, Young-Sang;Kim, Woo-Sung;Oh, Kyung-Soo;Song, Woo-Suk;Kim, Se-Jun
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.8 no.2
    • /
    • pp.115-120
    • /
    • 2009
  • Purpose: To evaluate the outcomes of three different surgical approaches in treating a distal radius fracture with dorsal communition. Materials and Methods: From April, 2006 to May, 2009, 49 patients over age of 60years old with unstable dorsal communition distal radius fracture were analyzed. We compared maintainability of reduction by radiological follow-up observations and clinical outcomes using Mayo wrist scores. One-Way ANOVA test was performed to examine the statistical correlation between the methods. Results: All three approaches provided satisfactory post-op reduction results. However, follow-up observations showed significant loss of reduction in the external fixation only group compared to the added bone graft group and the volar anatomical locking plate group (P<0.05). Mayo wrist score was indifferent between the three groups. Conclusion: Treatment of a distal radius fracture with severe dorsal communition using an external fixation only appears to be insufficient in maintaining reduction of a cancellous bone defect.

  • PDF

Stabilization of Short Juxta-articular Fractures Using a Circular External Skeletal Fixator System in Dogs (개에서 원형외고정장치를 이용한 관절주위 골절의 안정화)

  • Cheong, Hye-Yeon;Kim, Joo-Ho;Cha, Jae-Gwan;Seol, Jae-Won;Kim, Min-Su;Lee, Hae-Beom
    • Journal of Veterinary Clinics
    • /
    • v.31 no.6
    • /
    • pp.523-526
    • /
    • 2014
  • Three dogs were admitted for repair of bone fracture. Case 1 (Maltese, 1.8 kg, intact female, 5-month-old) and case 2 (poodle, 3.0 kg, intact female, 6-month-old) had non-weight bearing lameness in the left pelvic limb, and case 3 (mixed, 3.3 kg, intact female, age unknown) had non-weight-bearing lameness in the left thoracic limb. On orthopedic examination, there was pain, crepitus, palpable instability and substantial soft tissue swelling on the affected side. No neurological deficits were identified. Radiographs revealed left proximal metaphyseal tibial and fibular fractures in cases 1 and 2, and left proximal metaphyseal radial and ulnar fractures in case 3. All cases had closed long-bone fractures with short juxta-articular fracture segments. Under fluoroscopic guidance, proper placement of the ring fixation elements was confirmed during surgery. Two or three rings were used to stabilize fractures with traditional circular external skeletal fixators (CESF). Postoperative radiographs showed acceptable alignment and apposition of the previously identified fracture. Time to radiographic union ranged from 5 to 14 weeks and there were no signs of implant failure or pin tract infection. Functional outcomes were excellent in all cases. CESF can be successfully used to reduce short juxta-articular fractures in which bone plates or external skeletal fixation cannot be applied.

Evaluation of Residual Strength in Damaged Brittle Materials (취성재료의 손상후 잔류강도 평가)

  • Sin, Hyeong-Seop;O, Sang-Yeop;Seo, Chang-Min
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.5
    • /
    • pp.932-938
    • /
    • 2002
  • In structural applications, brittle materials such as soda-lime glasses and ceramics are usually subjected to multiaxial stress state. Brittle materials with cracks or damage by foreign object impacts are apt to fracture abruptly from cracks, because of their properities of very high strength and low fracture toughness. But in most cases, the residual strength of structural members with damage has been tested under uniaxial stress condition such as the 4-point bend test. Depending upon the crack pattern developed, the strength under multiaxial stress state might be different from the one under uniaxial. A comparative study was carried out to investigate the influence of stress state on the residual strength evaluation. In comparable tests, the residual strength under biaxial stress state by the ball-on-ring test was greater than that under the uniaxial one by the 4-point bend test, when a small size indendation crack was introduced. In the case that crack having an angle of 90deg. to the applied stress direction, the ratio of biaxial to uniaxial flexure strength was about 1.12. The residual strength was different from crack angles to loading direction when it was evaluated by the 4-point bend test. The ratio of residual strength of 45deg. crack to 90deg. one was about 1.20. In the case of specimen cracked by a spherical impact, it was shown that an overall decrease in flexure strength with increasing impact velocity, and the critical impact velocity for formation of a radial and/or cone crack was about 30m/s. In those cases that relatively large cracks were developed as compared with the case of indented cracks, the ratio of residual strength under biaxial stress state to one uniaxial became small.

Feasibility of Hydraulic Fracturing for Securing Additional Saline Groundwater in the Land-based Aquaculture Farm (양식장 용수 추가 확보를 위한 수압파쇄 적용성 평가)

  • Lee, Byung Sun;Kim, Young In;Park, Hak Yun;Cho, Jung Hwan;Song, Sung-Ho
    • Journal of Soil and Groundwater Environment
    • /
    • v.20 no.7
    • /
    • pp.34-42
    • /
    • 2015
  • Feasibility tests for the hydraulic fracturing were conducted in order to secure additional saline groundwater for irrigating to the land-based aquaculture farm. Two boreholes were placed to the aquaculture farm A and B, respectively. A hydraulic fracturing using single packer was applied to major fracture zones within two boreholes. To identify effects of hydraulic fracturing on securing additional saline groundwater, some selective methods including well logging methods, pumping tests, and groundwater quality analysis were commonly applied to the boreholes before and after the hydraulic fracturing. Enlarging/creating fracture zones, increasing water contents in bedrock near boreholes, and increasing transmissivity were observed after the hydraulic fracturing. Even though the hydraulic fracturing could be an alternative to secure additional saline groundwater to the land-based aquaculture farm, salinity of the groundwater did not meet optimal thresholds for each fingerling in two farms: Fresh submarine groundwater discharge flowed the more into borehole of the farm A that resulted in decreasing a salinity value. Increased saline groundwater quantity in the borehole of the farm B rarely affect to the salinity. Although salinity problem of groundwater limited its direct use for the farms, the mixing with seawater could be effectively used for the fingerlings during the early stage. A horizontal radial collector well placed in the alluvial layer could be an alternative for the farms as well.

A Comparative Review on Carthmi-Flos Pharmacopuncture Treatment - Focused on Clinical Study (홍화약침 시술에 관한 임상논문 비교연구)

  • Lee, Soo-Hwan;Yoon, Jeong-Won;Kim, Soon-Joong
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.27 no.4
    • /
    • pp.55-65
    • /
    • 2017
  • Objectives The purpose of this review is to analyze results of case studies and controlled studies about Carthmi-Flos pharmacopuncture. Based on the review, authors desire to suggest the study model including precise information and evident the effect of Carthmi-Flos pharmacopuncture objectively in treating clinical disorders. Methods We search 44 studies about Carthmi-Flos pharmacopuncture from 6 Korean web databases, using words 'Carthmi-Flos pharmacopuncture' in Korean alphabet. This study had been conducted throughout 1 month (July, 2017). We selected case studies and controlled trials in investigated 44 thesis, excluding experimental research and thesis not using the Carthmi-Flos pharmacopuncture for major treatment. Results We analyze 13 case reports and 7 controlled trials. As a result, Carthmi-Flos Pharmacopuncture was used mostly in musculoskeletal, neurological diseases. But this can be applied to internal diseases. Disorders reported effectively were carpal tunnel syndrome, degenerative knee joint arthritis, posterior neck pain, low back pain, radial nerve palsy, shoulder pain, lumbar compression fracture, alopecia areata, chronic daily headache, duverney fracture, oligomenorrhea, cervical disc herniation, rheumatoid arthritis and cervical headache. Conclusions As we analyzed, Carthmi-Flos pharmacopuncture is specifically effective in musculoskeletal and neurologic diseases. But there are various problems in study design. To design accurately, the study design should include much more specific information. And the result can be more precise by excluding other methods.

Study on the Improvement of Strength for 12% Chromium Steel Rotor (12% Cr 로터강의 강도 개선에 관한 연구)

  • Jang, Yun-Seok;O, Se-Uk
    • Journal of Ocean Engineering and Technology
    • /
    • v.3 no.2
    • /
    • pp.125-137
    • /
    • 1989
  • To check technical improvement in the soundness and strength of 12% Cr steel rotor, a 25 tons of rotor with 65 tons of ingot was made in real size and was cut to pieces to take test samples, and the various mechanical tests such as impact, tensile, creep, and fatigue were carried out. The strengths are compared with those of 1% Cr-Mo-V rotor of same size. Microstructures of the samples are examined and reviewed. The results can be summarized as follows. 1) Fracture appearance transition temperatures are 80.deg. C at the center part and 60.deg. C near surface of 12% Cr rotor, and 8.deg. C near surface of 1% Cr-Mo-V rotor. 2) Comparative rapid softening occurs at higher temperatures above 600.deg. C for 12% Cr steel and 550.deg. C for 1% Cr-Mo-V steel in tension tests. 3) Fatigue crack propagation rate of 12% Cr steel is almost same as that of 1% Cr-Mo-V steel at the same corresponding surface part of the rotors. The crack growth rate of center part of 12% Cr rotor is faster than near surface part of the rotor, and the crack growth rate at the load condition of R=0.04 is slower than that of the load condition of R=0.5 for both 12% Cr steel and 1% Cr-Mo-V steel. 4) Crack growth rate of radial direction near surface of 12% Cr rotor is faster than that of transverse direction at the same part because of the difference in residual stresses. 5) Both creep and fatigue strengths of 12% Cr steel are superior to those of 1% Cr-Mo-V steel and the difference is thought the effect of climb and glide controlled creep by solid solution of alloying elements and dispersion of carbides.

  • PDF

Study on the Improvement of Strength for 12% Chromium Steel Rotor (12% Cr 로터강의 강도 개선에 관한 연구)

  • Jang, Yun-Seok;O, Se-Uk
    • Journal of Ocean Engineering and Technology
    • /
    • v.3 no.2
    • /
    • pp.625-625
    • /
    • 1989
  • To check technical improvement in the soundness and strength of 12% Cr steel rotor, a 25 tons of rotor with 65 tons of ingot was made in real size and was cut to pieces to take test samples, and the various mechanical tests such as impact, tensile, creep, and fatigue were carried out. The strengths are compared with those of 1% Cr-Mo-V rotor of same size. Microstructures of the samples are examined and reviewed. The results can be summarized as follows. 1) Fracture appearance transition temperatures are 80.deg. C at the center part and 60.deg. C near surface of 12% Cr rotor, and 8.deg. C near surface of 1% Cr-Mo-V rotor. 2) Comparative rapid softening occurs at higher temperatures above 600.deg. C for 12% Cr steel and 550.deg. C for 1% Cr-Mo-V steel in tension tests. 3) Fatigue crack propagation rate of 12% Cr steel is almost same as that of 1% Cr-Mo-V steel at the same corresponding surface part of the rotors. The crack growth rate of center part of 12% Cr rotor is faster than near surface part of the rotor, and the crack growth rate at the load condition of R=0.04 is slower than that of the load condition of R=0.5 for both 12% Cr steel and 1% Cr-Mo-V steel. 4) Crack growth rate of radial direction near surface of 12% Cr rotor is faster than that of transverse direction at the same part because of the difference in residual stresses. 5) Both creep and fatigue strengths of 12% Cr steel are superior to those of 1% Cr-Mo-V steel and the difference is thought the effect of climb and glide controlled creep by solid solution of alloying elements and dispersion of carbides.