• Title/Summary/Keyword: Radial Load

Search Result 375, Processing Time 0.092 seconds

Critical Speed Analysis of a 75 Ton Class Liquid Rocket Engine Turbopump due to Load Characteristics (75톤급 액체로켓엔진 터보펌프의 하중 특성에 따른 임계속도 해석)

  • Jeon, Seong-Min;Kwak, Hyun-D.;Hong, Soon-Sam;Kim, Jin-Han
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.22-29
    • /
    • 2011
  • Critical speed of high thrust liquid rocket engine turbopump is obtained through a rotordynamic analysis and a unloaded turbopump test is peformed for validation of the numerical model. The first critical speed predicted by the numerical analysis is correlated well with the test result for the bearing unloaded rotor condition only considering mass unbalance load. Using the previous rotordynamic model, critical speed variation is estimated as a function of varied bearing stiffness due to pump and turbine radial loads with relative angle difference. From the numerical analysis, it is found that the relative angle difference of pump and turbine radial loads greatly affects the critical speed. However, additional axial load reduces the effect derived from the relative angle difference of radial loads.

  • PDF

Critical Speed Analysis of a 75 Ton Class Liquid Rocket Engine Turbopump due to Load Characteristics (75톤급 액체로켓엔진 터보펌프의 하중 특성에 따른 임계속도 해석)

  • Jeon, Seong-Min;Kwak, Hyun-D.;Hong, Soon-Sam;Kim, Jin-Han
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.16 no.4
    • /
    • pp.42-49
    • /
    • 2012
  • Critical speed of high thrust liquid rocket engine turbopump is obtained through a rotordynamic analysis and a unloaded turbopump test is peformed for validation of the numerical model. The first critical speed predicted by the numerical analysis is correlated well with the test result for the bearing unloaded rotor condition only considering mass unbalance load. Using the previous rotordynamic model, critical speed variation is estimated as a function of varied bearing stiffness due to pump and turbine radial loads with relative angle difference. From the numerical analysis, it is found that the relative angle difference of pump and turbine radial loads greatly affects the critical speed. However, additional axial load reduces the effect derived from the relative angle difference of radial loads.

Study on the Semi-Analytical Ice Load Calculation Methods for the Ice-Breaking Simulation (쇄빙시뮬레이션을 위한 반해석적 빙하중 계산법 고찰)

  • Kim, Jeong-Hwan;Jang, Beom-Seon;Kim, Yooil
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.57 no.6
    • /
    • pp.353-364
    • /
    • 2020
  • This paper presents the semi-analytical ice load calculation methods that are useful to simulate the ice-breaking process. Since the semi-analytical methods rely on the previously developed closed form equations or numerical analysis results, the user's exact understanding for the equations must be supported in order to use the methods properly. In this study, various failure modes of ice such as local crushing, in-plane splitting failure, out-of-plane bending failure and radial or circumferential cracking with rotation of the broken ice floe are considered. Based on the presented methods, the fracture modes were evaluated according to the size and thickness of ice. In addition, time series analysis for the ice-breaking process was performed on several ice conditions and the results were analyzed.

The Switch Installation Criteria For Satisfying Future Reliability Goal (향후 신뢰도 목표를 만족하는 개폐기 설치 기준 제시)

  • Jo, Nam-Hun;O, Jeong-Hwan;Ha, Bok-Nam;Lee, Heung-Ho
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.9
    • /
    • pp.433-440
    • /
    • 2002
  • The addition of switches to a distribution feeder does, in general, increase reliability by decreasing the duration of the outage of many to the customers on the feeder. To cover its service area so that feeder-level delivery reaches sufficiently close to all customers, feeders typically split their routes many times, in what is often called a lateral feeder. It is interesting to note, however, that the effectiveness of a switch is very much dependent on the types of lateral feeder. The types of lateral are classified into two types. The first is loop lateral feeder that can connect its load to an adjacent feeder through a tie line in case that a fault occurs in its feeder and it is laid out so that every feeder has complete fault backup through re-switching of its loads to other sources like a main feeder The second is the radial lateral feeder cannot connect its load to an adjacent line, no provision is made for contingency backup of feeders. There are no other circuits in the radial lateral feeder form which to restore power. In this study, we evaluate the effectiveness of a switch installation between on the radial and loop lateral feeders to increase reliability by decreasing the duration of the outage. These results can help power utility to design the switch layouts on the radial and loop lateral feeder system.

Analytical Approach for Optimal Allocation of Distributed Generators to Minimize Losses

  • Kaur, Navdeep;Jain, Sanjay Kumar
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.6
    • /
    • pp.1582-1589
    • /
    • 2016
  • In this paper the integration of Distributed Generation (DG) in radial distribution system is investigated by computing the optimal site and size of DG to be placed. An analytical expression based on equivalent current injection has been derived by utilizing topological structure of radial distribution system to find optimal size of DG to minimize losses. In the presented formulation, the optimal DG placement is obtained without repeatedly computing the load flow. The proposed formulation can be used to find the optimal size of all types of DGs namely Type-I, Type-II, Type-III and Type-IV DGs. The investigations are carried out on IEEE 33-bus and 69-bus radial distribution systems. The optimal DG placement results into reduction in active and reactive power losses and improvement in voltage profile of the buses.

Relation of Deformation between Die and Product in Backward extrusion (후방압출 공정에서 금형과 제품의 변형관계)

  • 박태식
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2000.04a
    • /
    • pp.83-87
    • /
    • 2000
  • The die for cold forging gets a ver high axial load and radial pressure during processing and hence deforms considerably in the radial direction. This radial deformation of die becomes a important factor influencing the dimensional accuracy of a product. In order to obtain a product with highly accurate dimension therefore it is essential to acquire some information on elastic deformation of the die and the product. The study has been performed for the relation of the deformation between a die and a product in backward extrusion. The strain of the die has been given by the simple experiment using the strain gauges attached to the outer surface of the die. Also the history of the deformation of the die and the product has been given by the experiment and Lames' formula. The results has been compared with the previous another method. The study has given useful results for the deformation history of the die and the product through the experiment and Lame's formula in backward extrusion which can be applied in the die design for the product with accurate dimension

  • PDF

Dynamic Behaviour of a Radial Compliant Crank Mechanism Used in Scroll Compressor (스크롤 압축기에 적용된 가변반경 크랭크 기구의 동적 거동에 관한 연구)

  • 김태종;한동철
    • Tribology and Lubricants
    • /
    • v.12 no.2
    • /
    • pp.8-19
    • /
    • 1996
  • Scroll compressor using a slide bushing type radial compliant crank mechanism is modelled, and it's dynamic behaviour characteristics are analyzed. Sealing forces generated in the flank surfaces of the orbiting scroll depending on the distance, e, from slide bushing center to crank pin center are calculated. From the stable condition of orbiting scroll for the moment equilibrium in tangential direction, the range of e is determined as 0$r_o$. Transient response of a crankshaft supported by two journal bearings is investigated, considering applied load, moment, and unbalance force by eccentric mass. As a result, conical whirl mode with circular orbits are obtained. The characteristics of journal orbits and frictional losses are calculated with a variation of viscosity and bearing clearance.

A Method for Indentifying Broken Rotor Bar and Stator Winding Fault in a Low-voltage Squirrel-cage Induction Motor Using Radial Flux Sensor

  • Youn, Young-Woo;Hwang, Don-Ha;Sun, Jong-Ho;Kang, Dong-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.5
    • /
    • pp.666-670
    • /
    • 2011
  • In this paper, a method for detecting broken rotor bar and stator winding fault in a low voltage squirrel-case induction motor using an air-gap flux variation analysis is proposed to develop a simple and low cost diagnosis technique. To measure the leakage flux in radial direction, a radial flux sensor is designed as a search coil and installed between stator slots. The proposed method is able to identify two kinds of motor faults by calculating load condition of motors and monitoring abnormal signals those are related with motor faults. Experimental results obtained on 7.5kW three-phase squirrel-cage induction motors are discussed to verify the performance of the proposed method.

Pressure Pulsation Characteristics of a Multiple-Delivery Radial Piston Hydrulic Pump (다중 토출 레이디얼 유압 피스톤 펌프의 압력 맥동 특성)

  • Choi, S.R.;Lim, J.C.;Lee, I.Y.
    • Journal of Drive and Control
    • /
    • v.11 no.2
    • /
    • pp.1-8
    • /
    • 2014
  • In this study, the authors carried out experiments and numerical simulations in order to clarify the pressure pulsation characteristics in multiple-delivery rotating-cam and stationary-cylinder type radial piston pumps. Also, a tee filter was applied to the pump in order to mitigate the pressure pulsation. Through the experiments and simulations, it was known that pressure pulsation with a magnitude higher than 40% of the mean load pressure could occur in the pump used in the experiments. Moreover, it was confirmed that a tee filter designed in this study could effectively mitigate the pressure pulsation.

Load Distribution, Contact and Fatigue Life Analysis for Ball Bearing of Under Moment Load (모멘트 하중을 고려한 볼베어링의 하중분배, 접촉 및 피로수명 해석)

  • Kim, Young-Kuk;Moon, Seok-Man;Kim, Tae-Wan;Cho, Yong-Joo
    • Tribology and Lubricants
    • /
    • v.27 no.3
    • /
    • pp.162-166
    • /
    • 2011
  • This study is aimed to predict the fatigue life for bearings under combined radial, thrust and moment load. In order to do this, a series of simulation such as bearing load distribution, initial surface stress, subsurface stress and fatigue analysis is needed. And using the bearing's material fatigue property we can predict fatigue life for ball bearing.