• 제목/요약/키워드: Radial Deviation

검색결과 77건 처리시간 0.029초

동축류 버너에서 생성된 부분 예혼합 화염을 이용한 화염 온도 측정 검정원 연구 (Study on the Partially Premixed Flames Produced by a Coflow Burner as Temperature Calibration Source)

  • 박철웅;한재원;신현동
    • 한국연소학회지
    • /
    • 제5권1호
    • /
    • pp.91-98
    • /
    • 2000
  • We investigated a uniform temperature zone, produced by double flame structure of a co flow CH4/air partially premixed flame, to be used as a temperature calibration source for laser diagnostics. A broadband N2 CARS(coherent anti-Stokes Raman spectroscopy) system with a modeless laser was used for temperature measurement. When the stoichiometric ratio was 1.5, we found the uniform temperature zone in radial direction of the flame of which the averaged temperature was 2110 K with standard deviation 24 K. In the stoichiometric ratio range between 2.0 and 2.5, we found very stable temperature-varying zones in vertical direction at the center of the flame. The size of the zone was approximately 15 mm and it covered a temperature range from 300 K to 1900 K. We also suggest that this zone can be used as a calibration source for 2-D PLIF(planar laser induced flurescence) temperature measurement.

  • PDF

키보드와 마우스 사용시 착용식 손목 지지대 효과 (The Effect of Wearable Wrist Rest During Keyboard and Mouse Use)

  • 박경수;박강효;홍기범
    • 대한인간공학회지
    • /
    • 제27권3호
    • /
    • pp.33-41
    • /
    • 2008
  • The goal of this study was to compare wrist posture, muscular loads and perceived comfort among wearable wrist rest (WR), general wrist rest(GR), no wrist rest(NR) during keyboard and mouse use. Thirteen subjects performed text editing task in three test conditions: wearable wrist rest(WR), general wrist rest(GR), no wrist rest(NR). During text editing task, the right wrist posture was recorded by an electrogoniometer and the muscle activity in upper trapezius, anterior deltoid, extensor digitorum, extensor carpi ulnaris were recorded by electromyography. After all of the tests, the subjects rated perceived comfort. Working with wearable wrist rest(WR), compared to no wrist rest(NR) and general wrist rest(GR), decreased wrist radial/ulnar deviation and also decreased muscle activity in upper trapezius and anterior deltoid. At the same time, in work with wearable wrist rest(WR), the subjects rated more comfort at 5 of 8 body locations(shoulder, upper arm, wrist, hand, body).

비절삭 저항상수에 따른 절삭력 예측 (Cutting Force Estimation Considering the Specific Cutting Force Constant)

  • 김종도;윤문철
    • 한국기계가공학회지
    • /
    • 제18권10호
    • /
    • pp.75-82
    • /
    • 2019
  • Few studies have been conducted regarding theoretical turning force modelling while considering cutting constant. In this paper, a new cutting force modelling technique was suggested which considers the specific cutting force coefficients for turning. The specific cutting force is the multiplication of the cutting force coefficient and uncut chip thickness. This parameter was used for experimental modelling and prediction of theoretical cutting force. These coefficients, which can be obtained by fitting measured average forces in several conditions, were used for the formulation of three theoretical cutting forces for turning. The cutting force mechanism was verified in this research and its results were compared with each of the experimental and theoretical forces. The deviation of force was incurred by a small amount in this model and the predicted force considering feed rate, nose radius, and radial depth shows a physical behavior in main force, normal force, and feeding force, respectively. Therefore, this modelling technique can be used to effectively predict three turning forces with different tool geometries considering cutting force coefficients.

세포 실험용 다중 주파수 동시 노출 장치 제작 (Fabrication of Multiple-Frequency Exposure System for In Vitro Experiment)

  • 김태홍;서민경;문지연;백정기
    • 한국전자파학회논문지
    • /
    • 제23권2호
    • /
    • pp.213-219
    • /
    • 2012
  • 최근 이동 통신 서비스의 증가로 인해 인류는 다양한 전자파에 동시 노출되어 있다. 그러나 전자파의 인체 영향 연구는 주로 단일 주파수에 대해서 행해졌다. 본 논문에서는 다중 주파수의 전자파를 동시에 노출시킬 수 있는 세포 실험 장치를 제작하였다. 세포 실험 장치는 836.5 MHz 주파수의 CDMA(Code Division Multiple Access) 및 1,950 MHz의 WCDMA(Wideband Code Division Multiple Access) 주파수의 신호를 동시에 발생시킬 수 있도록 광대역 특성을 갖는 radial transmission line 형으로 구성하였다. 변조된 신호는 증폭기, 디지털 감쇄기, RF 결합기를 통하여 원추형 안테나로 전달된다. SAR(Specific Absorption Rate)값은 광학 온도 프로브를 이용하여 petri dish 내 9개 지점에 대하여 3회 측정한 평균값을 이용하여 측정하였다. 측정된 안테나의 반사 손실은 -15dB 이하였고, 단위 입력 전력당 SAR 평균과 표준 편차는 CDMA 주파수에서 $0.105{\pm}0.019$ W/kg, WCDMA 주파수에서 $0.262{\pm}0.055$ W/kg이었다.

유동층 연소로에서 충전물이 압력 요동 특성에 미치는 영향 (The Effect of the Packing Materials on the Pressure Fluctuations in Fluidized Bed)

  • 김미영;조병렬;박상찬;이동규;김의식
    • 공업화학
    • /
    • 제9권6호
    • /
    • pp.852-856
    • /
    • 1998
  • 유동층 연소로에서 압력 요동의 통계적 처리 방법을 이용하여 충전물질의 유동층 거동에 대한 영향을 분석하였다. 실험은 내경이 6.7cm인 유동화 장치에서 수행하였고, 실험변수는 입자크기 및 분포, 유동화가스, 유동층의 aspect ratio(L/D), 충전물 등이다. 충전물질은 스크린 충전물질을 사용하였고, 압력 요동 특성은 차압 전달기로 측정하였다. 측정 압력 요동 특성치는 평균값과 표준편차, power spectral밀도 합수의 주진동수 등이다. 압력요동의 표준 편차는 압력 측정 tap의 반경 방향에 거의 영향을 받지 않았으며, 압력 측정 tap의 축방향에서는 충전물이 없는 경우 가스분산판 약 4.5cm 이상에서는 거의 일정하다. 충전물의 크기가 증가할수록 주진동수는 감소하는 경향이 나타났으며, 충전물의 양이 10% 부근에서 주진동수가 가장 큰 변화값을 나타내었다. 압력 요동의 표준 편차는 유동층 연소로의 거동을 해석하고 유동화 현상을 설명하는데 효과적이며, 압력 요동의 특성들은 충전물질에 많은 영향을 받았다.

  • PDF

Super-SBM을 이용한 항만배후단지 입주 물류기업의 효율성 분석에 관한 연구 (A Study on Efficiency of Resident Logistics Companies in Port Hinterland Using Super-SBM)

  • 박종민;전준우;여기태
    • 한국항해항만학회지
    • /
    • 제39권6호
    • /
    • pp.507-514
    • /
    • 2015
  • 본 연구는 항만 물류배후단지에 입주하여 운영하는 입주업체들의 효율성을 분석하는 것을 연구의 목적으로 하였다. 인천항과 부산신항 항만 물류배후단지 13개 입주기업을 효율성 분석대상으로 하였으며, 투입변수는 투자액, 면적, 종업원 수를 사용하였고, 산출변수는 물동량과 매출액을 선정하였다. 효율성 분석방법으로는 전통적인 CCR 모형과 BCC 모형을 적용하고 이들의 한계점을 극복하기 위해 초효율성 모형과 Super-SBM 모형을 적용하였다. 초효율성 모형의 분석결과, 평균값은 0.777, 표준편차는 0.541로 나타나 각 기업 간 효율성 점수 차이는 33% 정도 존재하는 것으로 분석되었다. Super-SBM 모형의 분석결과, 평균값은 0.649, 표준편차는 0.489로 초효율성 모형에서 여분을 고려할 경우 기업 간 효율성 점수 평균이 약 13% 정도 감소한 것으로 나타났다. 이러한 감소의 의미는 비방사형 여분이 존재하는 DMU의 효율성 점수하락이 평균 13% 정도 됨을 의미한다. 투입요소의 비효율성 분석결과 면적 -33%, 투자액 -33%에 비해 종업원 수의 비효율성이 -45%로 가장 큰 것으로 분석되었다.

손목 자세와 외부 부하에 따른 손목 불편도 모델링 (Modeling of Wrist Discomfort with External Loads)

  • 최광수;박재규;정의승;최재호
    • 대한인간공학회지
    • /
    • 제24권3호
    • /
    • pp.11-27
    • /
    • 2005
  • The objectives of this study are to analyze representative wrist postures while using hand tools and parts at general assembly processes, to evaluate perceived discomfort on the wrist when external loads are present, and to suggest an evaluation and prediction model of perceived discomfort. Sixteen subjects participated in an experiment to appraise perceived discomfort. Three types of the wrist postures with five levels of non-neutralities were analyzed when five levels of external load were applied to each posture. The ANOVA results showed that the perceived discomfort of wrist postures was significantly affected by both the wrist posture and external load (p$<$0.001). It was also shown that some of the interactions between external loads and the wrist postures(Flexion/$Extension^*$Load, Flexion/$Extension^*$supination/pronation, ulnar/radial $deviation^*$supination/pronation) were significant(p$<$0.001). The result implies that a new posture classification scheme for workload assessment methods may be needed to reflect such effects of external load and wrist posture. A regression model of perceived discomfort was developed with respect to wrist posture and external load from the experimental data. A subsequent experiment revealed that the correlation coefficient between the predicted values of perceived discomfort from the model and the actual values obtained from the experiment was about 0.98. It is expected that the results help to properly estimate the body stress resulting from worker's postures and external loads and can be used as a valuable design guideline to analyze potential hazard of musculoskeletal diseases in industry.

한방 치료를 이용한 키엔벡 병의 치험 1례 (A Case Report on Kienb$\ddot{o}$ck's Disease by Korean Medical Treatments)

  • 이용은;김재수;임성철;이윤규;이봉효;정태영;이현종
    • Journal of Acupuncture Research
    • /
    • 제30권5호
    • /
    • pp.203-209
    • /
    • 2013
  • Objectives : The purpose of this study is to report the clinical effects of Korean medical treatment for Kienb$\ddot{o}$ck's disease. Methods : The patient was treated using acupuncture, electroacupuncture, herbal medicine, pharmacopuncture treatment, and other treatments including moxibustion, physical rehabilitation for 6 weeks. And we evaluated the patient through verbal rating scale(VRS), disability of the arm, shoulder and hand(DASH), range of motion(ROM). Results : After treatment, VRS is changed from 7 to 3, DASH is changed from 37.93 to 20.69. And ROM is changed from $60^{\circ}$ to $70^{\circ}$ in wrist flexion, and from $10^{\circ}$ to $15^{\circ}$ in radial deviation. Conclusion : These results suggest that Korean medical treatment is effective to the patient complaining pain and dysfunction.

The Effect of Wheelchair Propulsion on Carpal Tunnel Syndrome of Wrist Joint

  • Kong, Jin-Yong;Kwon, Hyuk-Cheol;Chang, Ki-Yeon;Jeong, Dong-Hoon
    • 한국전문물리치료학회지
    • /
    • 제11권4호
    • /
    • pp.7-17
    • /
    • 2004
  • Individuals who propel wheelchairs have a high prevalence of upper extremity injuries (i.e., carpal tunnel syndrome, elbow/shoulder tendonitis, impingement syndrome). Musculoskeletal injuries can result from overuse or incorrect use of manual wheelchairs, and can hinder rehabilitation efforts. To better understand the mechanisms of upper extremity injuries, this study investigates the motion of the wrist during wheelchair propulsion. This study also examines changes in the variables that occur with fatiguing wheelchair propulsion to determine how the time parameters of wheelchair propulsion and the state of fatigue influence the risk of injury. A two dimensional (2-D) analysis of wrist movement during the wheelchair stroke was performed. Twenty subjects propelled a wheelchair handrim on a motor-driven treadmill at two different velocities (50, 70 m/min). The results of this study were as follows; The difference in time parameters of wheelchair propulsion (cadence, cycle time, push time, recovery time, and PSP ratio) at two different velocities was statistically significant. The wrist kinematic characteristics had statistically significant differences at two different velocities, but wrist radial deviation and elbow flexion/extension had no statistically significant differences. There were statistically significant differences in relation to fatigue in the time parameter of wheelchair propulsion (70 m/min) between initial 1 minute and final 1 minute. The wrist kinematic characteristics between the initial 1 minute and final 1 minute in relation to fatigue had statistically significant differences but the wrist flexion-extension (50 m/min) had no statistically significant differences. According to the results, the risk of musculoskeletal injuries is increased by fatigue from wheelchair propulsion. To prevent musculoskeletal injuries, wheelchair users should train in a muscle endurance program and consider wearing a splinting/grove. Moreover, wheelchair users need education on propulsion posture, suitable joint position, and proper recovery patterns of propulsion.

  • PDF

남자 고등부 포환던지기 선수들의 연도 별 기록에 따른 글라이드와 딜리버리 국면의 운동학적 차이 (The Analysis of Kinematic Difference in Glide and Delivery Phase for the High School Male Shot Putter's Records classified by Year)

  • 박재명;장재관;김태삼
    • 한국운동역학회지
    • /
    • 제23권4호
    • /
    • pp.295-306
    • /
    • 2013
  • The purpose of this study was to provide high school male shot putters training methods of gliding and delivery motion through comparative analysis of kinematic characteristics. To accomplish this purpose, three dimensional motion analysis was performed for the subjects(PKC, KKH, YDL) who participated in high school male shot putter competition on 92nd (2011), 93rd (2013) National Sports Festival. The subjects were filmed by four Sony HXR-MC2000 video cameras with 60 fields/s. The three-dimensional kinematic data of the glide, conversion and delivery phase were obtained by Kwon3d 3.1 version. The data of the shoulder rotational angles and projection angles were calculated with Matlab R2009a. The following conclusions had been made. With the analysis of the gliding and stance length ratio, the gliding length was shorter at the TG than the SG with short-long technique but the gliding and stance length ratio was 46.8:53.2% respectively. The deviation of the shots trajectory from APSS(Athlete-plus-shot-system) revealed that the PKC showed similar to "n-a-b-c-I" of skilled S-shape type, KKH and YDL showed "n-a-d-f-I'" of unskilled type. Furthermore, they showed smaller radial distance from the central axis of the APSS and the shots were away from the linear trajectory. From this characteristics, The PKC who performed more TG than SG had shorter glide with S-shape of APSS(skilled type) showed the better record than others with technical skill. But KKH and YDL had bigger glide ratio with "n-a-d-f-I'" of unskilled type and improved their records with technical factor. The projection factor had an effect on the record directly. Because PKC maintained more lower glide and transition posture with momentum transfer through COG's rapid horizontal velocity respectively the subject possessed the characteristics of high horizontal and vertical velocity with large turning radius from shot putter to APSS.