• 제목/요약/키워드: Radial Deviation

검색결과 77건 처리시간 0.026초

Effects of Immersive Virtual Reality Intervention on Upper Extremity Function in Post-Stroke Patients (몰입형 가상현실 프로그램 Rapael Smart Glove가 뇌졸중 환자의 상지기능에 미치는 영향)

  • Bae, Wonjin;Kam, Kyungyoon
    • Journal of The Korean Society of Integrative Medicine
    • /
    • 제5권3호
    • /
    • pp.1-9
    • /
    • 2017
  • Purpose: The purpose of this study was to investigate the effects of an immersive, virtual reality-based exercise program on range of motion and dexterity in the upper extremities of stroke patients. Methods: Fifteen patients with hemiparesis after stroke participated in this study. The participants participated in Rapael Semart GloveTM, an immersive, virtual reality-based exercise program, performed for 30 minutes-, 3 times per week for 4 weeks. The Rapael Smart GloveTM program and a Box and Block Test (BBT) were used to measure range of motion and to assess dexterity, respectively, pre-and post-intervention. Results: Range of motion in pronation and supination of the forearm and flexion, extension, and ulnar deviation of the wrist improved after the intervention. Dexterity measured by BBT also improved. However, range of motion in flexion and extension of the fingers and radial deviation of the wrist did not improve. Conclusion: This study presents the effects of an immersive, virtual reality-based exercise program on hand function. In the future, a study comparing an immersive, virtual reality- based exercise program to other upper-extremity interventions for stroke patients should be conducted. A study about the effects of an immersive virtual reality program on activities of daily living is also needed.

The Endocardial Boundary Detection based on Statistical Charact'eristics of Echocardiographic Image (초음파 영상의 통계적 특성에 근거한 심내벽 윤곽선 검출)

  • Won, Chul-Ho;Kim, Myoung-Nam;Cho, Jin-Ho
    • Journal of Biomedical Engineering Research
    • /
    • 제17권3호
    • /
    • pp.365-372
    • /
    • 1996
  • The researches to acquire diagnostic parameters from ultrasonic images are advanced with the progress of the digital image processing technique. Especially, the detection of endocardial boundary is very important in ultrasonic images, because endocardial boundary is used as a clinical parameter to estimate both the cardiac area and the variation of cardiac volume. Various methods to detect cardiac boundary are proposed, but these are insufficient to detect boundary. In this paper, an algorithm that detects the endocardial boundary, expanding the cavity region from the center using statistical information, is proposed The value of mean and sty:nd, wd deviation in cavity region is lower than those in muscle re- gion. Therefore, if we define the multiplication of mean and standard deviation as homogeneous coefficient, it can lead to conclusion that the pixels with small variation of these coefficleno are cavity region, and extraction of endocardial boundary from cavity region is possible. The proposed method detected endocardial boundary more effectively than edge based or threshold based method and is robuster to noise than radial searching method that has high dependency for center position.

  • PDF

Functional Motion Analysis of Wrist Joints (손목관절의 기능적 운동 특성의 동작 분석)

  • Han Jung Soo
    • Journal of Biomedical Engineering Research
    • /
    • 제24권6호
    • /
    • pp.543-548
    • /
    • 2003
  • Injuries of wrist in upper extremity is common onset in industrialized world. The development of joint arthroplasty and mechanical joint is area of research for biomechanical engineer and surgeon for a decade. Therefore. the knowledge of characteristic of joint motion is essential to develop the artificial wrist joint. In this study. the joint motions of wrist required for activities of daily living (ADLs). including personal hygiene and care. and general home activity were measured using flexible electrogoniometer. Total of 25 different daily activities were separated into four groups and tested on 15 subjects who did not show any abnormality of their joint functions. The maximum functional range of motion required for ADLs were obtained and standardized for analysis and comparison. Also. a least functional range of motion for ADLs were investigated. Results revealed that any significant differences were not found in least functional range of motion between left and right wrist to perform ADLs. However. a significant difference was found in different ADLs. Therefore. least range of motion obtained in this study can be used as basic data to design artificial joint and set a goal for surgeon to achieve appropriate treatment from patients.

Endocardial boundary detection by fuzzy inference on echocardiography (퍼지 추론에 의한 심초음파 영상의 심내벽 윤곽선 검출)

  • 원철호;채승표;구성모;김명남;조진호
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • 제34S권5호
    • /
    • pp.35-44
    • /
    • 1997
  • In this paper, a an algorithm that detects the endocardial boundary, expanding the region from endocardial cavity using fuzzy inference, is proposed. This algorithm decides the ventricular cavity by fuzzy inference in process of searching each pixel from the inside of left ventricle in echocardial image and expands it. Uncertainty and fuzziness exists in decision of endocardial boundary. Therefore, we convert the lingustic representation of mean, standard deviation, and threshold value that are characteristic variables of endocardial boundary to fuzzy input and output variables. And, we extract proposed method is robuster to noise than radial searching method that is highly dependent on center position. To prove the similarity of detected boundary by fuzzy nference, we used the measures of SIZE, correlation coefficient, MSD, and RMSE and had acquired reasonable results.

  • PDF

Study on the partially premixed flames produced by a coflow burner as temperature calibration source (동축류 버너에서 생성된 부분 예혼합 화염을 이용한 화염 온도 측정 검정원 연구)

  • Park, Chul-Woung;Hahn, Jae-Won;Shin, Hyun-Dong
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2000년도 제21회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.160-167
    • /
    • 2000
  • We investigated a uniform temperature zone, produced by double flame structure of a coflow CH4/air partially premixed flame, to be used as a temperature calibration source for laser diagnostics. A broadband N2 CARS(coherent anti-Stokes Raman spectroscopy) system with a modeless laser was used for temperature measurement. When the stoichiometric ratio was 1.5, we found the uniform temperature zone in radial direction of the flame of which the averaged temperature was 2110 K with standard deviation 24 K. In the stoichiometric ratio range between 2.0 and 2.5, we found very stable temperature-varying zones in vertical direction at the center of the flame. The size of the zone was approximately 15 mm and it covered a temperature range from 300 K to 1900 K. We also suggest that this zone can be used as a calibration source for 2-D PLIF(planar laser induced flurescence) temperature measurement.

  • PDF

Wrist Motion in Computer Keyboard Typing

  • Han, Jung-Soo
    • Journal of Mechanical Science and Technology
    • /
    • 제17권12호
    • /
    • pp.2004-2009
    • /
    • 2003
  • The purpose of this study is to define how wrist motion is affected by different postures and supporting devices and to discover functional range of wrist motion for keyboard typing. The range of wrist motion (ROM) needed for fourteen experienced typists to type on a computer keyboard was measured by flexible and biaxial electrogoniometers. The most frequent wrist motion during typing was in extended and ulnarly deviated positions in both wrists. Range of wrist motion was similar in both wrists. The average ROM for keyboard typing with the typists' own posture was about 39 in flexion/extension (FEM) and 29 in radial/ulnar deviation (RUD) in both wrists. The range of wrist motion was significantly reduced to 30 in FEM and 27 in RUD with use of either wrist or forearm supporting devices, which suggests that these devices might help to relieve fatigue, discomfort, or pain during and/or after typing. Results of this study will be of interest to clinicians and helpful to those who are professionally or non-professionally involved in typing.

Using a Disturbance Observer for Eccentricity Compensation in Optical Storage Systems

  • Kim, Kyung-Soo
    • Transactions on Control, Automation and Systems Engineering
    • /
    • 제4권4호
    • /
    • pp.319-323
    • /
    • 2002
  • In this paper, we consider the track-following control problem in the optical data storage systems in the presence of the eccentricity. The eccentricity results in the radial deviation of the objective lens so that it degrades the reliability of the data decoding system. To cope with the eccentricity, an adaptive disturbance compensation technique is newly proposed in the time domain based on a disturbance observer of reduced order, which effectively estimates the low frequency components of the disturbance. The proposed compensator is simply added to the conventional feedback control. The error dynamics of the observer and the sensitivity analysis are given to illustrate the effectiveness of the proposed approach. Finally, through experiments in an optical storage system, the feasibility of the proposed approach is verified.

An Experimental Study on the Characteristics of Generated Particle using Homogeneous Condensation Particle Generator (응축입자 발생기에서의 입자 발생특성에 관한 실험적 연구)

  • Kim, J.H.;Kim, S.S.
    • Proceedings of the KSME Conference
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.392-397
    • /
    • 2000
  • Mono-disperse particles generated by a condensation particle generator are widely used to meet the experimental and industrial needs. The characteristics of particles generated by homogeneous nucleation have been studied experimentally using a laminar flow condensation particle generator. Dry nitrogen gas saturated with oleic acid vapor was cooled well below the saturation temperature causing the highly supersaturated vapor to nucleate. The dependence of GSD(Geometric Standard Deviation), GMD(Geometric Mean Diameter), and the mass concentration of particles on the temperature at the evaporator, flow rate and the temperature condition at condenser was studied. The experimental results show that the mass concentration of particles is affected by the radial temperature profile at condenser. Nucleation at the center of the condenser causes the mass concentration of particles to increase. The experimental results also show that the suppression of additional nucleation by a constant temperature condition at the condenser increases the mean diameter of particle.

  • PDF

Investigation of crystallinity and microstructure of $YMnO_3$ single crystal grown by floating zone method

  • Cho, N.T.;Kwon, D.H.;Shin, J.H.;Ahn, C.I.;Shim, K.B.
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • 제13권4호
    • /
    • pp.168-171
    • /
    • 2003
  • $YMnO_{3}$ single crystals have been grown by a floating zone technique and the optimal growth conditions were investigated. Their crystallinity and microstructure were characterized by the chemical etch pit patterns, their distribution and the compositional difference depending on the G value. In particular, the microstructural feature was interpreted in terms of compositional deviation along radial direction on (1010) growth plane.

Improvement of a characteristic point detection algorithm of arterial pulse (동맥맥파의 특징점 검출 알고리즘 개선에 관한 연구)

  • Jeon, Young-Ju;Lee, Jeon;Kim, Jong-Yeol;Lee, Lark-Beom;Im, Jae-Jong
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1916-1917
    • /
    • 2007
  • Aortic AIx(augmentation index) has been used to measure aortic stiffness and evaluate ventricular load quantitatively. Algorithm for the detection of augmentation point gradually increases the differential order to detect inflection point rather than detects the distinctive point that appears after a specific time. Developed algorithm for AIx is proved to provide more accurate results than the ones developed by previous studies with the deviation from $-11.5{\pm}14.34$ points to $-3.75{\pm}1.26$ points. Results could provide the basis for the measurement of aortic stiffness using easily-measurable radial artery pulse waves, and could be extended to develop a system for early diagnosis of various vascular diseases.

  • PDF