• 제목/요약/키워드: Rack server

검색결과 20건 처리시간 0.038초

Rack-Level DC Power Solution for Volume Servers

  • Kwon, Won-Ok;Seo, Hae-Moon;Choi, Pyung
    • ETRI Journal
    • /
    • 제32권6호
    • /
    • pp.940-949
    • /
    • 2010
  • Rack-level DC power supply is the optimal technology for providing DC power to a volume server without any power infrastructure changes in an existing AC data center. In this paper, we propose a smartly controllable and monitorable DC rack power system. The proposed system improves power efficiency by changing the power distribution architecture of a conventional method in the rack. We developed an optimal power control method in multipower modules to provide high efficiency at low loads. In addition, the proposed system provides real-time web monitoring of the rack power and environment around a rack. In our experiments, the proposed system improved the power efficiency by over 10% compared to an AC power system providing N+1 redundant power and power monitoring.

효율성 증가를 위한 블록 단위 스마트 랙 기술 개발 (Block Smart Rack Technology Development for Increased Efficiency)

  • 태효식;박구락
    • 한국컴퓨터정보학회논문지
    • /
    • 제20권4호
    • /
    • pp.11-16
    • /
    • 2015
  • 데이터센터는 전 세계적으로 클라우드 기반 IT 솔루션의 발전과 더불어 빅 데이터, 교육, 커뮤니케이션 수단의 발달과 전자기기 사용이 증가함에 따라 국내외로 그 수요가 꾸준히 증가하는 추세에 있다. 이러한 데이터센터의 증가는 IT장비의 발전을 가속화 시켰으며 서버 랙의 발열 또한 크게 높이는 결과를 가지고 왔다. 데이터 센터의 전산 발열량은 IT서버 전력사용의 99%이상이 열로 변환되므로, 서버의 크기와 용량이 증가할수록 발열량 또한 상승하게 된다. 본 논문에서는 공냉식 냉각방식을 중심으로, 데이터센터의 에너지 절감을 위한 공조시스템을 연구 하였으며, 해당 시스템의 성능분석 및 모의실험을 통하여 실제로 에너지 절감 효과가 있는 것으로 분석되었다.

IDC용 소형 통합보안라우터의 실시간 트래픽쉐이핑과 IPS의 융합 구현 (A Convergence Implementation of Realtime Traffic Shaping and IPS on Small Integrated Security Router for IDC)

  • 양승의;박기영;정회경
    • 한국정보통신학회논문지
    • /
    • 제23권7호
    • /
    • pp.861-868
    • /
    • 2019
  • 최근 들어 빅데이터와 사물인터넷 그리고 인공지능 등 다양한 서버 기반의 서비스가 온라인상에서 이루어지고 있다. 이에 따라 안정적인 서버 운영을 지원하는 IDC(Internet Data Center)의 수요도 커지고 있다. IDC는 안정적인 회선과 전력공급시설을 갖춘 서버 입주시설로써 효율적으로 구분되어진 랙 단위 서브네트워크 상에 서버를 20~30대씩 묶어 관리하는 시설이다. 여기서는 랙 단위로 서버들의 보안, 방화벽, 트래픽 등을 효율적으로 관리해주는 방법이 필요하다. 즉 라우터, 방화벽, IPS 그리고 회선속도를 제어해 주는 트래픽쉐이핑 기능과 최근 관심 분야인 VPN 기술까지 지원해야 한다. 이를 지원하기 위해 3~5종의 상용 장비를 채택할 경우 도입비용은 물론 운용관리에 큰 부담일수 있다. 따라서 본 논문에서는 5가지 기능을 하나의 랙 단위 소형 통합보안라우터에 구현하는 방법을 제시하고, 특히 IDC에서는 필수 기술인 트래픽 쉐이핑과 IPS를 융합 구현하며 이에 따른 효용성도 제시하고자 한다.

데이터센터의 급기온도 변화가 서버 냉각 성능에 미치는 영향에 대한 연구 (A Study on the Effects of Supply Air Temperature on the Server Cooling Performance in a Data Center)

  • 장현재
    • 설비공학논문집
    • /
    • 제30권2호
    • /
    • pp.83-91
    • /
    • 2018
  • A datacenter is a high energy consuming facility whose cooling energy consumption rate is 10~20 times larger than general office buildings. The higher the temperature of supply air from a CRAC (computer room air-conditioner) is supplied, the more energy efficient cooling is possible because of improving the COP of a chiller and advanced range of outdoor air temperature available for the economizer cycles. However, because the temperature of cold air flowing into server computers varies depending on air mixing configurations in a computer room, the proper supply air temperature must be considered based on the investigation of air mixing and heat dissipation. By these, this study aims to understand the effects of variation of the supply air temperature on the air flow distributions, temperature distributions and rack cooling efficiencies. Computational fluid dynamics (CFD) aided in conducting the investigation. As a result, the variation of the supply air temperature does not affect the air flow distributions. However, it mainly affects the temperature distribution. From the results of CFD simulations, Rack cooling indices (RCIHI and RCILO) were evaluated and showed the ideal state set at $19^{\circ}C$ of the supply air temperature.

소형 통합보안라우터의 실시간 트래픽쉐이핑과 IPS의 융합 (A Convergence of Realtime Traffic Shaping and IPS on Small Integrated Security Router)

  • 김도안;송현옥;이성옥;양승의;정회경
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2019년도 춘계학술대회
    • /
    • pp.454-455
    • /
    • 2019
  • IDC(Internet Data Center)는 안정적인 회선과 전력공급시설을 갖춘 서버 입주시설로써 효율적으로 구분되어진 랙 단위 서브네트워크 상에 서버를 20~30대씩 묶어 관리하는 시설이다. 여기서는 랙 단위로 서버들의 보안, 방화벽, 트래픽 등을 효율적으로 관리해주는 방법이 필요하다. 이를 지원하기 위해 3~5종의 상용 장비를 채택할 경우 도입비용은 물론 운용관리에 큰 부담일 수 있다. 따라서 본 논문에서는 5가지 기능을 하나의 랙 단위 소형 통합보안라우터에 구현하는 방법을 제시하고, 특히 IDC에서는 필수 기술인 트래픽 쉐이핑과 IPS를 융합 구현하며 이에 따른 효용성도 제시하고자 한다.

  • PDF

Implementation of web server monitoring system using crawling technology

  • Yu, Young-Geun;Nam, Ki-Bok;Park, Koo-Rack
    • 한국컴퓨터정보학회논문지
    • /
    • 제24권4호
    • /
    • pp.123-128
    • /
    • 2019
  • In modern society, there are WEB sites that provides information in various fields by many advances in IT technology. As the number of users accessing the Web increases, one server becomes unavailable, and multiple servers are deployed to provide the service. In addition, systems that control servers are required to manage multiple servers. However, server control systems in the existing market are mostly those that notify managers through SMS and apps when a server's down or a controlled port is closed. However, in case of servers that generate a lot of traffic, the Web server and the WAS are operated and managed each independently. The WEB and WAS provide service by connecting to each other. However, the connection between WEB and WAS may be disconnected due to various environmental factors. In this case, the existing control system can not determine whether the service is working properly. Even in the case of WEB and WAS of a server that is operated independently, there is a phenomenon that the existing control system does not know the problem even when the normal service is not provided due to environmental factors such as disconnection to DB. In this paper, we implemented a system to check the normal state of Web service using Web crawling to solve this problem.

데이터센터의 공조시스템 계획을 위한 IT장비의 전력 및 발열량 예측에 대한 연구 (Power and Heat Load of IT Equipment Projections for New Data Center's HVAC System Design)

  • 조진균;신승호
    • 설비공학논문집
    • /
    • 제24권3호
    • /
    • pp.212-217
    • /
    • 2012
  • The cooling of data centers has emerged as a significant challenge as the density of IT equipment increased. With the rapid increasing of heat load and cooling system, predictions for electronics power trends have been closely watched. A data center power density projection is needed so that IT organizations can develop data centers with adequate cooling for reasonable lifetimes. This paper will discuss the need for something more than processor and equipment power trend projections which have overestimated the required infrastructure for customers. This projection will use data from a survey of actual enterprise data centers and the ASHRAE projections to formulate a data center server heat load trend projection.

1U 렉마운터블 서버에서의 힛싱크 성능에 대한 비교 분석 (Comparative Analysis of Heat Sink Performance At 1U Rack Mountable Server)

  • 신정용;이인호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1472-1475
    • /
    • 2004
  • Current processor power consumption has dramatically increased and already reached 115 Watts. Therefore, Heat sink design needs more high accuracy in 1U server. The target performance of heat sink is very dependent of fin geometry and it is also seriously affected by design conditions such as fan type, air duct shape and heatsink design parameters. The present paper investigates the behavior of heat sink performance under various conditions. The present work addresses pressurized type plane fin heat sinks having dimension of 40 mm by 40 mm by 56 mm fan.

  • PDF

에너지 수요예측 및 절감을 위한 데이터 센터 원격 관리 서비스 (Data Center Remote Management Service for Demanding Forecasting and Reduction of Energy U sage)

  • 한종훈;정대교;배광용
    • 정보통신설비학회논문지
    • /
    • 제9권3호
    • /
    • pp.107-111
    • /
    • 2010
  • This paper is concerned with data center remote management service for demanding forecasting and reduction of energy usage. More particularly, intelligent server rack, mounted on inside of the data center, collects information about energy usage and temperature per server. Using this information, management platform forecasts energy demand in the future and automatically makes report according green environment raw. By providing the remote management service through remote terminals, users are not tied to a time and place to control device inside the data center. In this way, the data center remote management service enhances operability of the facility.

  • PDF

SIP기반 임베디드 IoT 안전관리 시스템 설계 (Design of Safety Management System for IoT based in SIP)

  • 김삼택
    • 한국융합학회논문지
    • /
    • 제9권10호
    • /
    • pp.69-74
    • /
    • 2018
  • 국내, 외에서 개발된 IP, SIP 전관방송 시스템들은 윈도우나 리눅스 서버 환경에서 개발되어 서버-랙에 장착되어 운용되는 구조이며, 소비전력이 많고, 시스템 장애 시 원격 대응에 어려움이 있다. 따라서 본 논문에서는 전광방송을 위해 사물인터넷 서비스 구조를 이용하여 IoT 디바이스와 IoT 게이트웨이를 IoT 서비스 서버에 연결하는 IoT 플랫폼을 구성하고, 이 구조를 이용하여 호 처리 및 방송 기능을 내장하며 공공장소의 비상통화 및 비상방송을 처리할 수 있는 임베디드 OS 기반의 안전관리 시스템 서버를 설계 했다. 본 서버는 표준 SIP를 지원하는 다양한 SIP기반 통화 및 방송장치와 상호호환되어 구내전화 및 구내방송시스템과 통합구축이 가능하다.