• Title/Summary/Keyword: RZ

검색결과 141건 처리시간 0.025초

Characterization of one Time-Sequential Stereoscopic 3D Display - Part I: Temporal Analysis -

  • Pierre, Boher;Thierry, Leroux;Collomb-Patton, Veronique
    • Journal of Information Display
    • /
    • 제11권2호
    • /
    • pp.57-62
    • /
    • 2010
  • A method of characterizing time-sequential stereoscopic 3D displays based on the measurement of the temporal behavior of the systems vs. the grey levels is proposed. An Nvidia 3D vision kit with a 3D-ready SAMSUNG 2233RZ LCD display is characterized in the paper. OPTISCOPE SA especially designed for the precise measurements of the luminance and temporal behavior of LCD displays was used. The transmittance and response time of the shutter glasses was first evaluated. Then the grey-to-grey response times of the display were measured. The 2D and 3D behaviors of the display were then compared. Finally, the temporal behavior of the complete system was modeled, and the grey-level variations on one view were deduced as a function of the synchronization and level of the other eye. The main sources of imperfection were identified and quantified, and a full computation of the system performances was done.

매우 짬은 펄스를 사용한 400b1s 광전송의 성능과 광섬유의 색분산과의 상관관계 (The effect of fiber chromatic dispersion on 40-Gb/s optical transmission using very short pulses)

  • 박상규
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 2001년도 제12회 정기총회 및 01년도 동계학술발표회
    • /
    • pp.176-177
    • /
    • 2001
  • 최근에 매우 짧은 펄스를 이용한 RZ 포맷의 고속 광전송이 소개되었다. 컴퓨터 시뮬레이션을 통하여 이 포맷이 40Gb/s 전송에 유효하다는 것이 보여졌으며, 또한 실험을 통하여 이 포맷이 광섬유에서의 SPM에 저항성을 갖는다는 것of 보여졌다. 이 후 몇 편의 논문을 통하여 160Gb/s,300km(3$\times$100km)전송, 40Gb/s, 720km(6$\times$120km)전송 등이 보고되었다. 이 새로운 포맷에서는 짧은 펄스를 사용하므로 광신호가 고유의 정보량이 요구하는 최소한의 것보다 넓은 대역폭을 차지하게 되며 이는 광섬유의 분산과 상호작용을 하여 광전송중 광섬유의 비선형성에 의한 신호의 왜곡을 줄이는 역할을 하게 된다. (중략)

  • PDF

A Study on the Mechanics of Shear Spinning of Cones

  • Kim Jae-Hun;Park Jun-Hong;Kim Chul
    • Journal of Mechanical Science and Technology
    • /
    • 제20권6호
    • /
    • pp.806-818
    • /
    • 2006
  • The shear spinning process, where the plastic deformation zone is localized in a very small portion of the workpiece, shows a promise for increasingly broader application to the production of axially symmetric parts. In this paper, the three components of working force are calculated by the newly proposed deformation model in which the spinning process is understood as shearing deformation after uniaxial yielding by bending, and shear stress, $\tau_{rz}$ becomes $\kappa$, yield limit in pure shear, in the deformation zone. The tangential forces are first calculated and the feed forces and the normal forces are obtained by the assumption of uniform distribution of roller pressure on the contact surface. The optimum contact area is obtained by minimizing the bending energy required to get the assumed deformation of the blank. The calculated forces are compared with experimental results. A comparison shows that theoretical prediction is reasonably in good agreement with experimental results.

All-optical Integrated Parity Generator and Checker Using an SOA-based Optical Tree Architecture

  • Nair, Nivedita;Kaur, Sanmukh;Goyal, Rakesh
    • Current Optics and Photonics
    • /
    • 제2권5호
    • /
    • pp.400-406
    • /
    • 2018
  • The Semiconductor Optical Amplifier (SOA)-based Mach-Zehnder interferometer is a major contributor in all-optical digital processing and optical computation. Optical tree architecture provides one of the new, alternative schemes for integrated all-optical arithmetic and logical operations. In this paper, we propose an all-optical 3-bit integrated parity generator and checker using SOA-MZI-based optical tree architecture. The proposed scheme, able to process input signals at a desired operating wavelength, has been characterized using RZ-modulated signals at 10 Gbps. The maximum extinction ratios achieved at the output of the parity generator and checker are 10 dB and 8 dB respectively.

후기 고대영어의 동질군 장모음화 분석 (An Analysis of Homorganic Cluster Lengthening in Late Old English)

  • 권영국
    • 영어영문학
    • /
    • 제55권4호
    • /
    • pp.719-744
    • /
    • 2009
  • This paper aims to reexamine Homorganic Cluster Lengthening in Late Old English whereby OE short vowels became lengthened before specific consonant clusters such as /-ld, -nd, -mb, -rd, -rð, -ng, -rz/. As for the motivation for this apparently odd-looking sound change, I propose that it was the result of phonologization of the phonetic lengthening of syllables containing resonants homorganic with a following voiced obstruent. Adopting Luick's (1898) view of "resonant+voiced homorganic obstruent" phonologically as a single coda, I show that Homorganic Cluster Lengthening is in fact a natural sound change that can be explained with the proper postulation of a few quantity-related universal constraints within the framework of the Optimality Theory. The fact that the constraints and their ranking as posited in this paper can also account for Pre-Cluster Shortening points to the validity of my approach in the analysis of other quantity changes in Middle English.

IMPROVED VERSION ON SOME INEQUALITIES OF A POLYNOMIAL

  • Rashmi Rekha Sahoo;N. Reingachan;Robinson Soraisam;Khangembam Babina Devi;Barchand Chanam
    • Nonlinear Functional Analysis and Applications
    • /
    • 제28권4호
    • /
    • pp.919-928
    • /
    • 2023
  • Let P(z) be a polynomial of degree n and P(z) ≠ 0 in |z| < 1. Then for every real α and R > 1, Aziz [1] proved that $$\max\limits_{{\mid}z{\mid}=1}{\mid}P(Rz)-P(z){\mid}{\leq}{\frac{R^n-1}{2}}(M^2_{\alpha}+M^2_{{\alpha}+{\pi}})^{\frac{1}{2}}{\mid},$$ where $$M{\alpha}={\max\limits_{1{\leq}k{\leq}n}}{\mid}P(e^{i({\alpha}+2k{\pi})n}){\mid}.$$ In this paper, we establish some improvements and generalizations of the above inequality concerning the polynomials and their ordinary derivatives.

Comparative evaluation of roughness of titanium surfaces treated by different hygiene instruments

  • Unursaikhan, Otgonbayar;Lee, Jung-Seok;Cha, Jae-Kook;Park, Jung-Chul;Jung, Ui-Won;Kim, Chang-Sung;Cho, Kyoo-Sung;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • 제42권3호
    • /
    • pp.88-94
    • /
    • 2012
  • Purpose: The use of appropriate instruments to clean surfaces with minimal change, is critical for the successful maintenance of a dental implant. However, there is no consensus about the type and methodology for such instruments. The aim of this study was to characterize changes in the roughness of titanium surfaces treated by various scaling instruments. Methods: Thirty-seven identical disks (5 mm in diameter) were investigated in this study. The specimens were divided into eight groups according to the types of instrumentation and the angle of application. Ultrasonic scaling systems were applied on a titanium disk to simulate standard clinical conditions. The equipment included a piezoelectric ultrasonic scaler with a newly developed metallic tip (NS group), a piezoelectric ultrasonic scaler with a conventional tip (CS group), a piezoelectric root planer ultrasonic scaler with a conventional tip (PR group), and a plastic hand curette (PH group). In addition, the sites treated using piezoelectric ultrasonic scaler systems were divided two sub-groups: 15 and 45 degrees. The treated titanium surfaces were observed by scanning electron microscopy (SEM), and the average surface roughness (Ra) and mean roughness profile depth (Rz) were measured with a profilometer. Results: SEM no significant changes in the titanium surfaces in the NS group, regardless of the angle of application. The PH group also showed no marked changes to the titanium surface, although some smoothening was observed. All CS and PR sites lost their original texture and showed irregular surfaces in SEM analysis. The profilometer analysis demonstrated that the roughness values (Ra and Rz) of the titanium surfaces increased in all, except the PH and NS groups, which showed roughness decreases relative to the untreated control group. The Ra value differed significantly between the NS and PR groups (P<0.05). Conclusions: The results of this study indicated that changes in or damage to titanium surfaces might be more affected by the hardness of the scaler tip than by the application method. Within the limitations of this study, the newly developed metallic scaler tip might be especially suitable for peri-implant surface decontamination, due to its limited effects on the titanium surface.

DNA marker를 이용한 벼의 조직배양 효율개선 (Improvement of cultural efficiency using DNA markers in anther and seed culture of rice)

  • 김홍집;김태헌;손재근
    • Current Research on Agriculture and Life Sciences
    • /
    • 제27권
    • /
    • pp.21-28
    • /
    • 2009
  • 벼의 약 및 현미 배양효율과 관련된 DNA marker를 이용하여 인디카형 벼 품종인 'IR 36'의 조직배양 효율을 개선하기 위하여 실험한 결과를 요약하면 다음과 같다. 벼품종 간에 약 및 현미배양 효율을 비교한 결과 자포니카 > 통일형 > 인디카 형의 순으로 나타났다. 그러나 MGRI집단의 약배양에서 식물체분화율이 높은 계통으로 선발된 'MGRI 079'와 'MGRI 036'의 약배양 효율은 각각 19.8%, 19.9%로 가장 높게 나타났다. 'MGRI 079'에 'IR 36'이 여교배되어 양성된 $BC_2F_4$ 90 계통에 대한 marker검정을 실시하여 positive band를 나타내는 34계통을 선발할 수 있었다. 선발된 34계통 중 10 계통의 약배양에서 캘러스 형성률은 'IR 36' 보다 현저히 높았다. 선발된 10 계통의 현미배양에서도 캘러스형성 능력과 식물체재분화율이 'IR 36' 보다 높게 나타났다. $BC_2F_4$ 계통 중에서 식물체분화능력이 높은 계통으로 선발된 $BC_2F_4$-28은 간장이 'IR 36'보다 큰 편이었으나 출수기와 미립특성은 'IR 36'과 비슷하였다.

  • PDF

새로운 소신호 등가회로를 활용한 CDTA의 해석 및 저역통과 필터설계 (Analyzing of CDTA using a New Small Signal Equivalent Circuit and Application of LP Filters)

  • 방준호;송제호;이우춘
    • 한국산학기술학회논문지
    • /
    • 제15권12호
    • /
    • pp.7287-7291
    • /
    • 2014
  • CDTA는 전류모드로 아날로그 신호처리를 수행하는 능동회로로써 높은 선형성과 넓은 주파수 대역폭을 갖는 장점을 가지고 있다. 또한 입력 차동전류가 모두 접지된 임피던스 소자로 흐르게 되어 안정적인 동작을 수행하도록 한다. 본 논문에서는 CDTA를 해석하기 위해 새로운 소신호 등가회로를 제안한다. 제안된 소신호 등가회로는 입력과 내부단자 및 출력단자의 기생성분이 고려되어 크기 및 주파수 특성이 기존회로보다 정밀하게 분석될 수 있다. 제안된 소신호 회로를 활용하여 다양한 파라미터의 변화에 의하여 특성변동을 관찰한 결과, 저항(Rz) 등 특정한 값이 CDTA의 특성에 큰 영향을 주게 되는 것도 확인되었다. 본 논문에서 검증된 소신호 등가회로의 설계 파라미터는 CDTA 아날로그 회로와 그 응용회로를 설계하는데 편리성과 정확성을 제공할 수 있음을 보였다. 본 논문에서 제안된 CDTA 소신호등가회로를 이용하여 2.5MHz 저역통과 필터를 설계하였고 HSPICE 시뮬레이션을 통하여 그 유용성을 검증하였다.

일부 세치제와 주방세제 사용에 의한 의치상 레진의 표면변화 (Surface changes of denture base resin according to two toothpastes and a kitchen detergent)

  • 강재경;김수화;유은미;최혜숙;최유리;김광만
    • 한국치위생학회지
    • /
    • 제12권3호
    • /
    • pp.611-620
    • /
    • 2012
  • Objectives : This study evaluated the changes in surface roughness of denture base resin according to the types of denture cleansers. Methods : A denture base resin(Vertex RS, Dentimax, Netherland) was used. Two toothpaste(Antiplaque, Bukwang, Korea; 2080, Aekyung, Korea) and a kitchen detergent(Trio, Aekyung, Korea) were used as a denture cleanser. The specimens were put on the V8 crossbrushing machine(Sabri enterprises, Downers grove, IL, USA) to reproduce toothbrushing and the toothbrushes were flat, round end and soft type. The surfaces of denture base resin specimens were observed by profilometer(SJ-400, MITUTOYO, Japan) and SEM(S-3000N, Hitachi Co., Ibaraki, Japan). Results : 1. According to the result of measuring surface roughness, there was statistically significant difference in Ra, Rq, and Rz(p<0.05). 2. As for Ra, Rq and Rz, Antiplaque toothpaste showed the highest roughness, and there was significant difference from other groups(p<0.01). 2080 toothpaste, Trio, and distilled water were classified as the same group. 3. According to the result of observation with the SEM, the surfaces of the Antiplaque toothpaste group after toothbrushing showed the greatest roughness, and the surfaces of 2080 toothpaste, Trio, and distilled water groups were rough in order. Trio and distilled water had the surfaces similar to those before toothbrushing. Conclusions : Studies to compare the efficacy of denture management methods and examine the effects of denture cleansers on denture materials will be helpful for dental hygienists and dentists providing patients with proper information and education. And it will be also useful for denture users' oral health.