• 제목/요약/키워드: RT Simulation

검색결과 154건 처리시간 0.032초

OFDMA 무선 시스템에서의 시간-효용과 채널 상태 기반의 하향 링크 패킷 스케줄링 (Time Utility and Channel State based Wireless Downlink Packet Scheduling Algorithm for OFDMA System)

  • 류승완;서현화;정수정;임순용;박세권
    • 산업공학
    • /
    • 제17권spc호
    • /
    • pp.111-121
    • /
    • 2004
  • In this paper, we propose an urgency and efficiency based wireless packet scheduling (UEPS) algorithm that is able to schedule real time (RT) and non-real time (NRT) traffics at the same time. The proposed UEPS algorithm is designed to support wireless downlink packet scheduling in the OFDMA system which is a strong candidate wireless system for the next generation mobile communications. The UEPS algorithm uses the time-utility function as a scheduling urgency factor and the relative status of the current channel to the average one as an efficiency indicator of radio resource usage. The design goal of the UEPS algorithm is to maximize throughput of NRT traffics with satisfying QoS requirements of RT traffics. The simulation study shows that the proposed UEPS algorithm is able to give better throughput performance than existing wireless packet scheduling algorithms such as proportional fair (PF) and modified-largest weighted delay first (M-LWDF) while satisfying QoS requirements of RT traffics such as the average delay and the packet loss rate under various traffic loads.

Precise Prediction of Optical Performance for Near Infrared Instrument Using Adaptive Fitting Line

  • Ko, Kyeongyeon;Han, Jeong-Yeol;Nah, Jakyoung;Oh, Heeyoung;Yuk, In-Soo;Park, Chan;Chun, Moo-Young;Oh, Jae Sok;Kim, Kang-Min;Lee, Hanshin;Jeong, Ueejeong;Jaffe, Daniel T.
    • Journal of Astronomy and Space Sciences
    • /
    • 제30권4호
    • /
    • pp.307-314
    • /
    • 2013
  • Infrared optical systems are operated at low temperature and vacuum (LT-V) condition, whereas the assembly and alignment are performed at room temperature and non-vacuum (RT-NV) condition. The differences in temperature and pressure between assembly/alignment environments and operation environment change the physical characteristics of optical and opto-mechanical parts (e.g., thickness, height, length, curvature, and refractive index), and the resultant optical performance changes accordingly. In this study, using input relay optics (IO), among the components of the Immersion GRating INfrared Spectrograph (IGRINS) which is an infrared spectrograph, a simulation based on the physical information of this optical system and an actual experiment were performed; and optical performances in the RT-NV, RT-V, and LT-V environments were predicted with an accuracy of $0.014{\pm}0.007{\lambda}$ rms WFE, by developing an adaptive fitting line. The developed adaptive fitting line can quantitatively control assembly and alignment processes below ${\lambda}/70$ rms WFE. Therefore, it is expected that the subsequent processes of assembly, alignment, and performance analysis could not be repeated.

휴대 인터넷 시스템에서의 패킷 스케줄링 알고리즘 연구 (A Packet Scheduling Algorithm for High-speed Portable Internet System)

  • 최성훈
    • 산업경영시스템학회지
    • /
    • 제30권1호
    • /
    • pp.59-65
    • /
    • 2007
  • HPI (High-speed Portable Internet) system which provides high speed internet services is going to be commercialized soon. Since HPI provides simultaneously four different service types such as UGS (Unsolicited Grant Service), rtPS (real time Polling Service), nrtPS(non-real time Polling Service), and BE (Best Effort) under different QoS (Quality of Service) requirements and limited wireless channel resources, efficient packet scheduling mechanisms are necessary to increase the utilization of channels as well as to satisfy the various QoS requirements. This study regards the traffic data to be served as time series and proposes a new packet scheduling algorithm based on the nonparametric statistical test. The performance of the newly proposed algorithm is evaluated through the simulation analysis using a simulator that can evaluate the performance of packet scheduling mechanisms under various values of system parameters and measures such as packet delay time, data transmission rate, number of loss packets, and channel utilization.

Revised Reversible and Totally Irreversible Zones for the Linear Sweep Voltammetry at a Planar Electrode

  • Kwak Juhyoun
    • Bulletin of the Korean Chemical Society
    • /
    • 제15권1호
    • /
    • pp.57-63
    • /
    • 1994
  • Digital simulation program for one-dimensional geometric systems of electrochemical phenomena was developed. The accuracy of the digital simulation is discussed by comparing with the known solutions. Applying this program to the linear sweep voltammetry at a planar electrode for the electrode reaction, 0 + ne${\to}$R, the accurate current functions for the reversible and totally irreversible charge transfer systems were obtained. Comparing these current functions with the simulated voltammograms for various other values of ${\alpha}$ (0.1 to 1.0) and ${\Lambda}\;(10^{-5}\;to\;10^5)$, the revised zones that are different from those proposed by Matsuda and Ayabe for the reversible and totally irreversible systems are proposed. For ${\alpha}{\ge}$0.1 the reversible zone is in ${\Lambda}{\ge}10^{1.7}$ and the totally irreversible zone is in ${\Lambda}{\le}10^{-1.7}$, where ${\Lambda}=k^{\circ}/ [D_o^{1-{\alpha}}D_R^{\alpha}(nF/RT)v]^{1/2}$.

지하수 히트펌프 시스템의 대수층 활용 사레 연구 (Study on the aquifer utilization for a ground water heat pump system)

  • 심병완;이철우
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 추계학술대회
    • /
    • pp.32-35
    • /
    • 2006
  • The validation of a groundwater source heat pump system installation site is estimated by bydrogeothermic model ing. The hydraulic characteristics of the aquifer system is evaluated from pumping and recovery tests. In addition, the temperature distribution by the pumping and the injection of groundwater, and water level fluctuations are simulated by numerical modeling. The total cooling and heating load for the building is designed as 120RT(refrigeration ton) and the ground water source heat pump system covers 50RT as a subsidiary system The scenario of heat pump operation is organized as pumping and inject ion of groundwater that is performed for 8 hours per day in cooling mode for 90 days during the summer season The heat transfer by the injected warm water is limited near the inject ion wells in the simulated temperature distribution. The reason is that the given operation time is too short to expect broad thermal diffusion in large volume of the aquifer in the simulation time The simulated groundwater level and temperature distribution can be used as important data to develope an energy effective pumping and injection well system. Also it will be very useful to evaluate the hydraulic capacity of a target groundwater reservoir.

  • PDF

Comparison of Predicted Acoustics with the Measured Acoustic Properties of a Multi-Purpose Hall

  • Haan, Chan-Hoon
    • The Journal of the Acoustical Society of Korea
    • /
    • 제25권3E호
    • /
    • pp.95-100
    • /
    • 2006
  • The present study presents the design procedures and the acoustic properties of the main hall of Ansan Cultural Arts Center in Korea which has opened in 2004. The acoustic design values are compared with the measured acoustic properties of the completed multi-purpose hall. Acoustic design criteria were suggested in the design stage through the 3-dimentional computer simulations. The acoustic parameters including SPL, RT, C80, $D_{50}$M, RASTI were measured in the hall after completed. Acoustic measurements were carried out in the 40 measurement points using MLS sound source signal in 4 different sound source points. The results show the even distribution of sound levels within the 2.0dB of difference among all seats. The reverberation time of 1.66sec was measured which is similar to the objective value of 1.65 sec in empty states. It was also found that average C80 values lie in the objective extents of C80 from -1 to 3dB and average D50 value of 54 was measured. Thus, it is concluded that the hall can be used as a multi-purpose hall with a suitable acoustic conditions.

중학교 일반교실 실내음향 시뮬레이션에 관한 연구 (A Study on the Computer Simulation of Acoustic Characteristics in Middle School Lecture Room)

  • 모승준;이민섭
    • 교육시설
    • /
    • 제10권4호
    • /
    • pp.5-20
    • /
    • 2003
  • The purpose of the research on the noise of educational facilities is to build up pleasant environments by minimizing the influence on the students in the school. This study provides fundamental data for acoustic design by measuring, computer simulation and analyzing the room acoustic characteristics of the lecture room in middle school. For measurement on the factors of room acoustic, RT of lecture room and noise reductions depending on various walls of different structures were measured and analyzed. The lecture system being installed and carried out on the normal lecture room was divided into 4 types-employment of multimedia machines, employment of multimedia machines and loud speakers, employment of loud speaker, and existing verbal speaking-and SPL for each type was measured and analyzed. Based on the measured characteristics of acoustic characteristics for normal lecture room, the problems for environment of noise were understood through computer simulation, applications for improvements of performance for each facility were studied, schemes for improvements of performance by using the effects were presented, necessary fundamental data were secured, and schemes to enhance flexibility on the existing facilities of school against changing educational courses were secured.

2중열원 히트펌프시스템의 냉방성능예측에 관한 연구 (Cooling Performance Evaluation study of Dual-Source Heat Pump System)

  • 노관종;김지영;강은철;박희문;이의준
    • 한국지열·수열에너지학회논문집
    • /
    • 제3권1호
    • /
    • pp.1-9
    • /
    • 2007
  • A steady-state simulation model for Dual-Source Heat Pump(DSHP) of 8RT was presented. A Dual-Source Heat Pump(DSHP) has been designed to make up for the conventional air source heat pumps. The performance evaluation has been conducted under internal standard test conditions such as ISO-13256-1 and KS C 9306. However, as test conditions such as entering water, indoor and outdoor air conditions could not be controlled to satisfy the standard test conditions in outdoor tests, a series of experiments have been conducted with the actual test conditions. Then, computer models for DSHP could be used for the standard condition have developed using EES program. The model was developed from basic thermodynamic principles and heat transfer relations. Most of the parameters were obtained with EES from the actual catalog data. The simulation results were in good agreement with the experiments.

  • PDF

모바일 3차원 그래픽 아키덱쳐를 위한 시뮬레이션 프레임웍 (A Simulation Framework for Mobile 3D Graphics Architecture)

  • 이원종;박정수;한탁돈
    • 한국정보과학회:학술대회논문집
    • /
    • 한국정보과학회 2006년도 한국컴퓨터종합학술대회 논문집 Vol.33 No.1 (A)
    • /
    • pp.226-228
    • /
    • 2006
  • In this paper we describe a simulation and development framework for designing mobile 3D graphics architectures. We are developing a simple and flexible simulation and verification environment (SVE) that uses gITrace's ability to intercept and redirect an OpenGL/ES streams. In combination wlth gITrace to trace OpenGL/ES commands, the SVE simulates the behavior of mobile 3D graphics pipeline during playback of traces, and then produces the second geometry trace that can be used as a test vector for the Verilog/HDL RT-level model. By comparing the frame-by-frame results, we can conduct architectural verification. To demonstrate the functionality of the SVE, we show the implementation of the verified mobile 3D architecture on a FPGA board. For this, we also present an application development environment (ADE) includes a mobile graphics API and a device driver interface (DDI). The proposed two software environments, the SVE and the ADE could be used fer developing and testing mobile applications, architectural study and speculative hardware designs.

  • PDF

캡슐형 빙축열시스템에 대한 운전 시뮬레이션 및 에너지비용 분석 (Simulation and Energy Cost Calculation of Encapsulated Ice Storage System)

  • 이경호;주용진;최병윤;김상준
    • 태양에너지
    • /
    • 제19권3호
    • /
    • pp.63-73
    • /
    • 1999
  • Ice storage systems are used to shift the peak load in day time into night time in summer. This paper describes a system simulation of partial ice storage system composed of an encapsulated ice storage tank, a screw compressor chiller, a heat exchanger, and a brine pump. For the system simulation, a one-dimensional model of ice storage tank is developed and validated by comparison with the performance data from measurements of an ice storage tank installed at a building. The control strategies considered in this study are chiller priority and storage priority being used commercially. The system is simulated with design cooling load of 600 RT peak load in design day and with off-design day cooling load, and the electric energy costs of the two control strategies for the same system size are compared. As a result of calculation, the energy consumption in a week for storage priority is higher than that for chiller priority control. However due to lower cost of night electric charge rate, energy cost for storage priority control is lower than chiller priority.

  • PDF