• Title/Summary/Keyword: RT Simulation

Search Result 154, Processing Time 0.028 seconds

A Fast Resource Reallocation Protocol (FRRP) for rt-VBR MPEG-2 video services over ATM Networks (ATM 상에서 실시간 가변비트율 MPEG-2 동영상 서비스를 위한 고속 자원 재할당 프로토콜)

  • 홍승은;장경훈;김덕진;고성제
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.24 no.8B
    • /
    • pp.1426-1437
    • /
    • 1999
  • The introduction of fast packet switching networks such as the ATM leads to the possibility of video services with constant quality. However, the fixed traffic descriptor(TD), which is defined by ATM Forum and ITU-T, can not simultaneously satisfy network efficiency and video quality. This paper presents fast resource reallocation protocol (FRRP) which can provide an effective compromise between network efficiency and video quality. This protocol reallocates the network resources and then adapts the traffic to the reallocated resources. In the proposed method, a video session is divided into several time-intervals according to its generated traffic and TD is calculated which well characterizes the traffic during the specific subdivided interval. In addition, a system model, where MPEG coding algorithm and network control are unified, is proposal and the performance of the FRRP in terms of cell loss rate(CLR) is evaluated though the simulation using real video traffic(Star Wars). Simulation results show that the FRRP has only 5 ~35% CLR of the fixed TD.

  • PDF

The Development of Outdoor Augmented Reality System by GPS (GPS를 이용한 옥외용 증강현실 시스템 개발)

  • Choi, T.J.;Jang, B.T.;Han, S.H.;Kim, J.K.;Hur, W.
    • Proceedings of the IEEK Conference
    • /
    • 2000.06c
    • /
    • pp.153-156
    • /
    • 2000
  • In this paper, we developed an outdoor augmented reality system which has remote real scenes acquisition ability. The real scenes acquisition system consists of Image acquisition system, tracking system, wireless data transceiver and power supply. The tracking system consists of Tans Vector and RT-20 which measures a position and attitude of the CCD camera that attached to the remote control helicopter. Wireless data transceiver system is utilized for data transmission of remote system that of attitude, position information, and real scenes data that acquired by the CCD camera. Maximum propelling power of remote control helicopter is 15Kg, so we used 7.2V li-ion cell as a power supply for system minimize. As the results of experiment, the developing system presented application possibility of remote information acquisition system such as construction simulation & estimation, broadcasting, tour guide.

  • PDF

Probabilistic Evaluation of RV Integrity Under Pressurized Thermal Shock (가압열충격을 받는 원자로용기의 확률론적 건전성 평가)

  • Kim, Jong-min;Bae, Jae-hyun;Sohn, Gap-heon;Yoon, Ki-seok;Choi, Taek-Sang
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.90-95
    • /
    • 2004
  • The probabilistic fracture analysis is used to determine the effects of uncertainties involved in material properties, location and size of flaws, etc, which can not be addressed using a deterministic approach. In this paper the probabilistic fracture analysis is applied for evaluating the RV(Reactor Vessel) under PTS(Pressurised Thermal Shock). A semi-elliptical axial crack is assumed in the inside surface of RV. The selected random parameters are initial crack depth, neutron fluence, chemical composition of material (copper, nickel and phosphorous) and $RT_{NDT}$. The deterministically calculated $K_I$ and crack tip temperature are used for the probabilistic calculation. Using Monte Carlo simulation, the crack initiation probability for fixed flaw and PNNL(Pacific Northwest National Laboratory) flaw distribution is calculated. As the results show initiation probability of fixed flaw is much higher than that of PNNL distribution, the postulated crack sizes of 1/10t in this paper and 1/4t of ASME are evaluated to be very conservative.

  • PDF

Design of a High Temperature Production Heat Pump System Using Geothermal Water at Moderate Temperature (중온 지열수를 이용한 고온제조 열펌프 시스템 해석 및 설계)

  • Kim, Min-Sung;Baik, Young-Jin;Park, Seong-Ryong;Chang, Ki-Chang;Lee, Young-Soo;Ra, Ho-Sang
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.638-641
    • /
    • 2008
  • Geothermal water at moderate temperature in a range between 30 to $50^{\circ}C$ exists sparse in surroundings. Mostly they are utilized as heat or water source at spar zones in Korea. However, a large portion of used water is discarded due to its poor recovery quality and inferior application technologies. In this research, an innovative heat pump system based on the hybrid concept that combinate compression cycle and absorption cycle was investigated mathematically. The hybrid heat pump aims to recycle various kind of the heat sources at moderate temperature including geothermal water effectively. The prime objective of the simulation is to design a compression/absorption hybrid heat pump system which can make high temperature above the level of $90^{\circ}C$ and low temperature of $20^{\circ}C$ as well at the same using $50^{\circ}C$ geothermal heat water. As a result, primitive data was provided as a basis to design a prototype 3 RT class hybrid heat pump.

  • PDF

Effect of Acoustic Reflector's Surface Density on Sound Absorption Characteristics and Stage Acoustics (음향 반사판의 밀도별 흡음특성 및 무대음향에의 영향)

  • Kim, Young-Sun;Jeong, Jeong-Ho;Jeon, Jin-Yong;Kim, Myeong-Seok
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.5
    • /
    • pp.429-436
    • /
    • 2012
  • In concert halls and auditoriums, acoustic reflector and stage enclosure is one of the main factors on the room and stage acoustic characteristics. As a stage enclosure and acoustic reflector honey comb based light-weight reflector is widely used, because it is easy to install. However, there was not enough research on the surface density effect on room and stage acoustics. In this study, sound absorption coefficient tests on three kinds of wooden acoustic reflectors with different surface density were conducted. Surface density of acoustic reflector was changed from 11 kg/$m^2$ to 41 kg/$m^2$. For the low frequency excitation, sub-woofer was used with omnidirectional loud-speaker simultaneously. From the experiments, it was found that sound absorption coefficient below 250 Hz band was decrease by the increment of surface density. In order to check the influence of the surface density on room and stage acoustic parameters, room acoustic simulation was conducted with sound absorption coefficients, which were tested in reverberation chamber. By the increment of surface density of acoustic reflector, RT(reverberation time) and EDT(early decay time) were increased. Also, ST(stage support) was improved in low frequency bands.

Lyman-alpha radiative transfer through outflowing halo models to understand both the observed spectra and surface brightness profiles of Lyman-alpha halos around high-z star-forming galaxies

  • Song, Hyunmi;Seon, Kwang-il
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.43 no.1
    • /
    • pp.59.3-59.3
    • /
    • 2018
  • With a recent observational study of extended Lyman-alpha halos around individual high-z star-forming galaxies by Leclercq et al. (2017) using MUSE, we perform radiative transfer calculations to see if Lyman-alpha scattering can explain the spatial extents of the halos together with their spectra. We adopt a spherically-symmetric halo model in which Lyman-alpha sources and neutral hydrogen (HI) medium have exponential density distributions. The HI medium is set to have outflowing motion based on a momentum-driven wind scenario in a gravitational potential well. We run our Lyman-alpha radiative transfer code, LaRT, upon this halo model for various sets of parameters regarding the HI medium such as temperature, optical depth, density scale radius, outflow velocities, and dust content. We analyze simulation results to see the impact of each parameter on Lyman-alpha spectra and surface brightness profiles, and degeneracies between the parameters. We also find a parameter set that best reproduces simultaneously the observed spectra and surface brightness profiles of the MUSE Lyman-alpha halos.

  • PDF

Design and performance evaluation of G.983.1 based on Dynamic UC Protocol for ATM-PON (ATM-PON에서의 G.983.1을 이용한 Dynamic MAC Protocol의 설계 및 성능평가)

  • Jang, Seong-Ho;Jang, Jong-Uk
    • The KIPS Transactions:PartC
    • /
    • v.9C no.4
    • /
    • pp.523-530
    • /
    • 2002
  • Earlier efforts on optical access concentrated on the design of PONs for the collection and distribution portion of the access network. PON architecture is very simple but it requires MAC protocol for control of upstream traffic. This paper proposes a MAC protocol for a broadband access network using an ATM Passive Optical Network supporting CBR/rtYBR, nrtYBR, UBR and ABR traffic. For the proposed MAC scheme, we present grant field format, minislot format, and bandwidth allocation algorithm. From the simulation result, we have confirmed that our proposed scheme can reduce the average cell delay in comparison to that of conventional MAC schemes.

Estimation on the effect of design variables for sealing performance of the dust seal using finite element simulation (유한요소해석을 이용한 더스트 씰 밀봉성에 대한 설계변수의 영향평가)

  • Lee K.O.;Lee S.U.;Huh Y.M.;Kang S.S.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.123-124
    • /
    • 2006
  • Usually, hydraulic cylinder is widely used as the actuator in the equipment of construction machines, airplane and military machines. In case of these devices, due to use under severe environment such as water, $SiO^2$ and dust, etc. seal which has high packing ability and long service life has been required. These characteristics are largely influenced by material and geometries of seal such as approach angle, withdrawal angle and interference. Recently, many a study about seal material has been performed so that many materials have been developed. But the concrete studies including the relationships between geometry of seal and sealing performance have hardly been performed yet. Therefore, in this study, we predicted the deformation behavior and contact normal distribution of dust seal with the variation of geometries of seal lip using finite element analysis. And based on the results of analyses, we discussed the effects of the design variables fur sealing performance of the dust seal.

  • PDF

In-Situ Performance Analysis of Centrifugal Chiller According to Varying Conditions of Chilled and Cooling Water (현장에서 운전중인 터보냉동기의 냉수와 냉각수 조건 변화에 따른 성능 해석)

  • Kim, Yeong-Il;Jang, Yeong-Su;Sin, Yeong-Gi;Baek, Yeong-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.3
    • /
    • pp.482-490
    • /
    • 2002
  • This paper presents modelling and analyzing method of centrifugal chiller which has a rated capacity of 200 RT(703 kW) through on-site performance test. Field performance data of a chiller installed in a research building of KIST have been collected. Simple models were developed for predicting the heat exchanger and system performances by regression of chiller operation data during 5 days in August. The models proposed here account for the effect of variations of cooling capacity, temperatures and flew rates of secondary fluids. The proposed models can predict the actual performance data from June to September within $\pm$ 5% error. The COP of centrifugal chiller are estimated under the standard rating conditions and reduced mass flow rates of chilled and cooling water.

Cooling Performance Analysis of Solar Heating and Cooling System in an Office Building (사무소 건물 적용 태양열냉난방시스템의 냉방성능 분석)

  • Jang, Jae-Su;Ko, Myeong-Jin;Kim, Yong-Shik
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.217-222
    • /
    • 2011
  • This study examined the cooling performance of a solar heating and cooling system for an office building using the dynamic simulation program (TRNSYS). This solar heating and cooling system incorporates evacuated tube solar collectors of $204m^2$, storage tank of $8m^3$, 116.2kW auxiliary heater, single-effect $LiBr/H_2O$ absorption chiller of 20RT nominal cooling capacity. It was found that for the representing day showed peak cooling load the annual average collection efficiency of the collector was 32.9% and coefficient of performance of single-effect $LiBr/H_2O$ absorption chiller was 0.68. And the results shows for the cooling season the solar fraction of the solar heating and cooling system was 32.2% and maximal and minimal solar fraction was 63.4% for May 17.9% for July respectively.

  • PDF