• Title/Summary/Keyword: RS:X

Search Result 134, Processing Time 0.027 seconds

Insulin Inhibits the Expression of Adiponectin and AdipoR2 mRNA in Cultured Bovine Adipocytes

  • Sun, Y.G.;Zan, L.S.;Wang, H.B.;Guo, H.F.;Yang, D.P.;Zhao, X.L.;Gui, L.S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.22 no.10
    • /
    • pp.1429-1436
    • /
    • 2009
  • Adiponectin is an adipocyte-derived protein that has a regulatory role in energy homeostasis and influences insulin sensitivity. Its effects on glucose utilization and lipid metabolism are mediated by AdipoR1 and AdipoR2. How insulin affects adiponectin gene expression and secretion is still controversial. This study was conducted to determine the expression of adiponectin, AdipRs and $PPAR-\gamma$ during the differentiation of bovine preadipocytes and the effect of insulin on expression of these genes in bovine adipocytes. The bovine preadipocytes started to accumulate lipids three days after differentiation was induced, with increased expression of adiponectin, AdipoR2 and $PPAR-\gamma$ mRNAs. Insulin decreased the expression of adiponectin mRNA in a dose- and time-dependent fashion, and the inhibition was detectable at insulin concentrations as low as 10 nM and as early as 2 h after addition of 100 nM insulin. Insulin also inhibited the expression of AdipoR2 mRNA at concentrations from 1 to 1,000 nM or 24 h after addition of 100 nM insulin, but did not affect the expression of AdipoR1 in bovine adipocytes. Inhibition of PI3K with LY294002 reversed the inhibition of adiponectin and AdipoR2 mRNA expression by insulin. These results suggest that insulin suppresses the expression of adiponectin and AdipoR2 at least partially via the PI3K signal pathway.

Characteristics of Symmetric-Shape Parts Shearing on Micro NCT (마이크로 NCT에 의한 대칭형상구멍의 전단특성)

  • Hong N. P.;Kim B. H.;Chang I. B.;Kim H. Y.;Oh S. I.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2002.02a
    • /
    • pp.285-291
    • /
    • 2002
  • The shearing process for the sheet metal is normally used in the precision elements such as a frame of TFT-LCD or lead frame of If chips. In these precision elements, the burr formation prevents the system assembly and needs the additional burr removing process. In this paper, we developed the small size NC punching system which has an aligning kinematics between the rectangular shaped punch and die. The punch is driven by an ai cylinder and the sheet metal is moving on the X-Y table system which is driven by two stewing motors. The microprocessor control the whole system and communicate with the monitoring PC by RS232C serial communication protocol. The graphic user interface program in PC monitors nil control the punching system. The cross shaped joint hinge supports the punching die and positioned by two differential screws, whose are installed in perpendicular directions. The aligning between the punch and die is performed using the sheets of half thickness(0.1mm Brass) of the real process for the frame of the TFT-LCD. Using half thickness Brass, the burr formation is magnified and we can decide the aligning direction more easily then using the real thickness(0.2mm) Aluminum. In this paper, the aligning results are measured manually using the SEM photographs and we hope to make the automated aligning procedures using some kinds of image processing techniques.

  • PDF

Development of Respiration Gating RT Technique using Moving Phantom and Ultrasound Sensor: a feasibility study (동 팬텀과 초음파 센서를 이용한 호흡운동 조절 방사선치료 기술 개발)

  • Lee, Suk;Lee, Sang-Hoon;Shin, Dong-Ho;Yang, Dae-Sik;Choi, Myung-Sun;Kim, Chul-Yong
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2004.11a
    • /
    • pp.122-125
    • /
    • 2004
  • In radiotherapy of tumors in liver, enough planning target volume (PTV) margins are necessary to compensate breathing-related movement of tumor volumes. To overcome the problems, this study aims to obtain patients' body movements by using a moving phantom and an ultrasonic sensor, and to develop respiration gating techniques that can adjust patients' beds by using reversed values of the data obtained. The phantom made to measure patients' body movements is composed of a microprocessor (BS II, 20 MHz, 8K Byte), a sensor (Ultra-Sonic, range 3 cm ${\sim}$3 m), host computer (RS232C) and stepping motor (torque 2.3Kg) etc., and the program to control and operate it was developed. The program allows the phantom to move within the maximum range of 2 cm, its movements and corrections to take place in order, and x, y and z to move successively. After the moving phantom was adjusted by entering random movement data(three dimensional data form with distance of 2cm), and the phantom movements were acquired using the ultra sonic sensor, the two data were compared and analyzed. And then, after the movements by respiration were acquired by using guinea pigs, the real-time respiration gating techniques were drawn by operating the phantom with the reversed values of the data. The result of analyzing the acquisition-correction delay time for the three types of data values and about each value separately shows that the data values coincided with one another within 1% and that the acquisition-correction delay time was obtained real-time (2.34 ${\times}$ 10$^{-4}$sec). This study successfully confirms the clinic application possibility of respiration gating techniques by using a moving phantom and an ultra sonic sensor. With ongoing development of additional analysis system, which can be used in real-time set-up reproducibility analysis, it may be beneficially used in radiotherapy of moving tumors.

  • PDF

Development of Respiration Gating RT Technique using Moving Phantom and Ultrasound Sensor: a feasibility study (동 팬텀과 초음파 센서를 이용한 호흡운동 조절 방사선치료 기술 개발)

  • Lee Suk;Lee Sang Hoon;Shin Dongho;Yang Dae Sik;Choi Myung Sun;Kim Chul Yong
    • Radiation Oncology Journal
    • /
    • v.22 no.4
    • /
    • pp.316-324
    • /
    • 2004
  • Purpose : In radiotherapy of tumors in liver, enough planning target volume (PTV) margins are necessary to compensate breathing-related movement of tumor volumes. To overcome the problems, this study aims to obtain patients' body movements by using a moving phantom and an ultrasonic sensor, and to develop respiration sating techniques that can adjust patients' beds by using reversed values of the data obtained. Materials and Methods : The phantom made to measure patients' body movements is composed of a microprocessor (BS II, 20 MHz, 8K Byte), a sensor (Ultra-Sonic, range $3\~3$ m), host computer (RS232C) and stepping motor (torque 2.3 Kg) etc., and the program to control and operate it was developed. The program allows the phantom to move within the maximum range of 2 cm, its movements and corrections to take place In order, and x, y and z to move successively. After the moving phantom was adjusted by entering random movement data (three dimensional data form with distance of 2 cm), and the phantom movements were acquired using the ultra sonic sensor, the two data were compared and analyzed. And then, after the movements by respiration were acquired by using guinea pigs, the real-time respiration gating techniques were drawn by operating the phantom with the reversed values of the data. Results : The result of analyzing the acquisition-correction delay time the three types of data values and about each value separately shows that the data values coincided with one another within $1\%$ and that the acquisition-correction delay time was obtained real-time $(2.34{\times}10^{-4}sec)$. Conclusion : This study successfully confirms the clinic application possibility of respiration gating techniques by using a moving phantom and an ultrasonic sensor. With ongoing development of additional analysis system, which can be used in real-time set-up reproducibility analysis, it may be beneficially used in radiotherapy of moving tumors.

Molecular Epidemiological Characteristics of Vibrio Parahaemolyticus as Recently wilde-spreaded in Korea (최근 한국에서 유행하는 장염비브리오균의 분자 역학적 특성)

  • 김상숙;이희무;이중복
    • KSBB Journal
    • /
    • v.18 no.6
    • /
    • pp.522-528
    • /
    • 2003
  • The purpose of this study is to inquire into molecular epidemiological characteristics of Vibrio parahaemolyticus. For this study, 120 strains(120 strains of Vibrio parahaemolyticus sampled from diarrhea patients) were examined and analyzed for biochemical characteristics, TDH (thermostable direct hemolysin) antibiotics sensitivity and detection of toxR, gyrE, tdh, and tds gents. G-S PCR (Group Specific Polymerase), PFGE (Pulsed-field Gel Electrophoriesis) methods were performed on the materials from patients were results. 1 Vibrio parahaemolyticus didn't grow in 0% density of NaCl, but the fact was found that those grew in 8% density of NaCl. 2. O:K serotypes of Vibrio parahaemolyticus was turned up in domestic patients was 17 types. Among those O3:K6 was the most, it was 68.3%. 3. In 18 kinds of antibiotic tests resistant against Ampicillin, Ticacillin was comparatively high. the case of resistant against Ampicillin, Ticacillin, Vancomycin at the multiple resistant was 52.5%. 4. Toxin gene tdh had only 109 strains among 120 ones isolated from patients held the genes of 199bp size, and 11 strains was negativity 5. In the test of Kanagawa toxic productivity, 107 strains among strains isolated from patients appeared to be positivity reaction 6. The strain that held trh toxin was only 3, and those among test strains had the genes of 250bp size and that had tdh, trh genes at a time were 3 strains, and TDH toxic productivity of those were 16 times, and it was weak. 7. Group Specific-PCR appeared to be useful in the confirmation of O3:K6 serotype interrelations. 8. Three strains which showed difference of 7 DNA sequence even in the same serotype were detected by the result of analyzing the regular gene, toxRS DNA sequence. These strains are differ from general strains which carry infection easily. 9. These mutual dose epidemiological relations were classified into smaller-parts through PFGE method. As a result of such classify, 3 findings were found. V. parahaemolyticus sampled from diarrhea patients were classified into 3 types. And third, the result obtained through PFGE method can be used as a useful tool in a point of molecular-epidemiological view.

Some Characteristics of Teflon-Thermoluminescent Dosimeters (테프론 열형광선량계(熱螢光線量計)의 특성(特性))

  • Lee, Soo-Yong
    • Journal of Radiation Protection and Research
    • /
    • v.7 no.1
    • /
    • pp.23-33
    • /
    • 1982
  • The characteristic thermoluminescence responses of Teflon thermoluminescent dosimeters to radiations have been studied by the variation of radiation qualities as well as the high dose radiations. The change in the sensitivity of TLDs for different radiation qualities were studied through not only the photon energy dependence but also the change of supralinearity on the photon energy dependence, by exposing $^{60}Co$ gamma rays, the effective X-rays of 44keV, 69keV, 108keV, and thermal neutron of 0.04 eV. The results were as the following: The TL response of $T-CaSO_4$: Dy as a function of absorbed dose was linear up to about 5 Gy, and the response beyond 5Gy was supralinear for $^{60}Co$ gamma rays. The supralinearity of T-LiF-7 became noticeably apparent more than that of $T-CaSO_4$:Dy and also the lower the LET of radiation became the higher the supralinear effects were. No supralinearity appeared for the thermal neutron irradiations equivalent to 10Gy of $^{60}Co$ gamma rays. The relative sensitivities (Rs), which depended on the doses of $^{60}Co$ gamma rays to the TLDs of T-LiF-7 and T-$CaSO_4$:Dy could be, respectively, approximated to the following empirical formula fitted by the least square method: $$R_{LiF}=1.021-0.04581\;logD+0.402(logD)^2-0.405(logD)^3,\;\;5{\times}10^3{\geq}D{\geq}1(Gy)$$ $$R_{CaSO_4}=0.976-0.3241\;logD+0.262(logD)^2-0.298(logD)^3,\;5{\times}10^3{\geq}D{\geq}1(Gy)$$.

  • PDF

Site Competition of Ca2+ and Cs+ Ions in the Framework of Zeolite Y (Si/Al = 1.56) and Their Crystallographic Studies (제올라이트 Y (Si/Al = 1.56) 골격 내의 Ca2+과 Cs+ 이온의 자리 경쟁 및 그들의 결정학적 연구)

  • Kim, Hu Sik;Park, Jong Sam;Lim, Woo Taik
    • Journal of the Mineralogical Society of Korea
    • /
    • v.31 no.4
    • /
    • pp.235-248
    • /
    • 2018
  • The present work was performed in order to study the effect of competing cation of $Ca^{2+}$ ion on ion exchange of $Cs^+$ on zeolite Y (Si/Al = 1.56). Three single-crystals of fully dehydrated and partially $Cs^+$-exchanged zeolites Y (Si/Al = 1.56) were prepared by the flow method using mixed ion-exchange solutions. The $CsNO_3:Ca(NO_3)_2$ molar ratios of the ion exchange solution were 1 : 1 (crystal 1), 1 : 100 (crystal 2), and 1 : 250 (crystal 3) with a total concentration of 0.05 M. The single-crystals were then vacuum dehydrated at 723 K and $1{\times}10^{-4}Pa$ for 2 days. The structures of the crystals were determined by single-crystal synchrotron X-ray diffraction technique in the cubic space group $Fd{\bar{3}}m$, at 100(1) K. The unit-cell formulas of crystals 1, 2, and 3 were ${\mid}Cs_{21}Ca_{27}{\mid}[Si_{117}Al_{75}O_{384}]-FAU$, ${\mid}Cs_2Ca_{36.5}{\mid}[Si_{117}Al_{75}O_{384}]-FAU$, and ${\mid}Cs_1Ca_{37}{\mid}[Si_{117}Al_{75}O_{384}]-FAU$, respectively. In all three crystals, the $Ca^{2+}$ ions preferred to occupy site I in the D6Rs, with the remainder occupying sites I', II', and II. On the other hand, the significant differences in the fractional distribution of $Cs^+$ ions are observed depending on the intial $Cs^+$ concentrations in given ion exchange solution. In Crystal 1, $Cs^+$ ion are located at sites II', II, III, and III', and in crystal 2, at sites II, IIIa, and IIIb. In crystal 3, $Cs^+$ ions are only located at sites IIIa and IIIb. The degree of $Cs^+$ ion exchange decreased sharply from 28.0 to 2.7 to 1.3 % as the initial $Ca^{2+}$ concentration increases and the $Cs^+$ content decreases.

Lack of Influence of an XRCC3 Gene Polymorphism on Oral Cancer Susceptibility: Meta-analysis

  • Zhang, En-Jiao;Cui, Zhi-Gang;Xu, Zhong-Fei;Duan, Wei-Yi;Huang, Shao-Hui;Tan, Xue-Xin;Yin, Zhi-Hua;Sun, Chang-Fu;Lu, Li
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.23
    • /
    • pp.10329-10334
    • /
    • 2015
  • Background: To systematically summarize the association between the X-ray repair cross complementing 3 (XRCC3) gene polymorphism and oral cancer susceptibility by meta-analysis. Materials and Methods: Databases including PubMed, EMbase, CNKI, VIP and WanFang Data were searched to identify case-control studies concerning the association between an XRCC3 gene polymorphism and the risk of oral cancer from the inception to June 2014. Two reviewers independently screened the literature according to the criteria, extracted the data and assessed the quality. Then meta-analysis was performed using Stata 11.0 software. Results: Seven published case-control studies including 775 patients with oral cancer and 1922 controls were selected. Associations between the rs861539 polymorphism and overall oral cancer risk were not statistically significant in all kinds of comparison models (CT vs CC: OR=0.94, 95%CI=0.74-1.18; TT vs CC: OR=0.94, 95%CI=0.64-1.38; dominant model: OR=0.95, 95%CI=0.76-1.18; recessive model: OR=0.94, 95%CI=0.69-1.29; allele T vs C: OR=0.97, 95%CI=0.84-1.11). In the stratified analysis by ethnicity, no significant associations were found among Asians and Caucasians. On stratification by tumor type, no significant associations were found for cancer and oral premalignant lesions. Conclusions: The XRCC3 gene polymorphism was not found to be associated with the risk of oral cancer. Considering the limited quality of the included case-control studies, more high quality studies with large sample size are needed to verify the above conclusion.

Model Design for Successful Adoption of ERP Cost Management System (ERP 원가관리시스템의 성공적 도입을 위한 모형 설계)

  • 오은해;김창수;이재엽
    • Proceedings of the Korea Association of Information Systems Conference
    • /
    • 2004.11a
    • /
    • pp.349-365
    • /
    • 2004
  • 기업의 또는 부문에서 구축된 각 정보시스템들은 시간이 지남에 따라 기업의 경쟁우위를 확보하기 위해 통합의 필요성이 증대하게 되었는데, 이러한 필요에 의해 제기된 것이 ERP(Enterprise Resource Planning: 전사적 자원관리)이다. 급변하는 기업의 내${\cdot}$외부 환경에 대해 신속하게 대응하기 위해 ERP 시스템을 도입하는 기업들의 수가 증가함에도 불구하고 ERP 원가관리시스템에 대한 연구는 아직까지 그 범위가 한정되었다고 할 수 있다. 본 논문은 ERP 도입 현황 및 원가관리시스템의 도입${\cdot}$설계현황자료를 바탕으로 하여, 중소기업의 ERP 원가관리시스템의 성공적 도입을 위한 방향을 제시하고자 한다. 중소기업에서 ERP 원가관리시스템을 도입할 때는, 원가관리시스템의 특성과 구축 목표, 구조 설계, 원가대상 설정 등과 관련된 다음과 같은 사항들을 고려하여야 성공적인 시스템을 구축할 수 있을 것이다. 첫째, ERP 원가관리시스템 특성 분석단계에서는 원가정보를 구성하는 내용의 충실성뿐만 아니라 정보가 전달${\cdot}$제공되는 범위와 대상의 적합성과 함께 그 표현의 형식 또한 고려되어야 한다. 둘째, ERP 원가관리시스템 구축목표 설정단계에서는 인가관리정보의 산출요건에 대한 명확한 이해와 목표설정을 기반으로 해야 한다. 셋째, ERP 원가 관리시스템 구조 분석 및 선계단계에서는 생산관리시스템 및 원가대상 설정 분석이 이루어져야 한다. 넷째, ERP 원가관리시스템 구현단계에서는 원가관리시스템과 타 계열시스템과의 인터페이스를 고려해야 한다. 따라서 원가관리시스템의 구현 시에는 관련시스템에서 어떠한 정보론 인터페이스 받을 것인가를 명확히 하여 시스템 가동 시에 타 관련시스템과 원활한 연계가 되도록 함으로써 전사적 종합시스템이 되도록 하여야 학 것이다.RS와 제진장치에 대한 전체적인 성능평가를 성공적으로 수행하였으며, 운전결과 및 경험은 향후 상용설비를 위한 기본자료로 활용할 것이다.X>, 그리고 입원기간은 $21.6\pm14.3일(13\~56)$이었다. 수술 후 평균 CK-MB는 $11.3\pm14.1ng/mL$였다. 수술 후 조기 혈관 개존율은 $100\% (24/24)$였다. 모든 환자에서 완전 추적이 가능하였으며 평균 추적기간은 $20.4\pm15.2개월(5\~43)$이었다. 이 기간 중 사망환자나 흉통이 재발한 환자는 없었다. 걸론: 80세 이상 고령의 환자에서 OPCAB은 수술 후 합병증을 줄이고 좋은 결과를 보여 주었다. 그러므로 고령의 환자에서도 관상동맥우회술의 적응증이 되면 적극적으로 수술을 시행할 필요가 있으며, 수술방법은 OPCAB이 좋을 것으로 생각한다서 실용적 개발의 가능성을 보였다.에 따라 현저한 차이가 있었으며 Dimethoate처리$(30^{\circ}C,\; 0.2\%$액에서 24시간)에 의하여 볍씨의 호흡량이 감소되었다. 9) 산소호흡량과 평균발아소요일수와는 $\gamma=-0.945$로 부의 유의한 상관을 보였는데 산소호흡량이 많은 품종은 평균발아소요일수가 짧은 경향을 보였다. 10) 볍씨의 산소호흡량과 Dimethoate 처리에 의한 볍씨의 발아저해도와는 $\gamma=-0,771$의 높은 부의 상관을 보였으며 산색호흡량이 많은 품종이 발아저해도가 낮고 적은 품종에서는 높았다. 현재까지는 그 활동이 11.2년의 주기성을 보여주지만 그 이전에 있어서는 그 활동이 극히 약화되었을 뿐만 아니라 매우 불규칙하다는 것이 Schneider와 Mass(1975)에 의해 밝혀졌다. 결국 1710년대부터 현재까지 우리나라에 있어서 벼멸구와 흰

  • PDF

프레스다이용 코일스프링의 신뢰성평가 및 고장분석 사례 발표

  • Go, Se-Hyeon;Park, Sang-Yong;Jang, Jin-Man;Lee, Won-Sik
    • Proceedings of the Korean Reliability Society Conference
    • /
    • 2006.05a
    • /
    • pp.239-246
    • /
    • 2006
  • 프레스다이용 코일스프링은 자동차 및 전자제품의 외형생산에 필요한 금형 내에 장착되는 금형용 스프링으로서 녹아웃 및 스트리퍼 등에 사용되고 있다. 프레스다이용 코일스프링이 사용 중 파손 시에는 고가인 금형의 손상 및 생산성에 영향을 미칠 수도 있기 때문에 사용 환경에서의 신뢰성확보가 요구되어지고 있다. 특히 중(重)하중 및 극중(極重)하중용 스프링은 과거 현장에서 파손사례가 자주 발생함으로 인해 외산을 선호하는 경향이 있는 형편이다. 이에 국산 스프링의 신뢰성검증 및 확보를 위해 신뢰성기반구축사업을 통해 신뢰성평가기준(RS D 0014)가 제정되었으며, 이 평가기준에 의거하여 국내 업체의 제품에 대해 신뢰성평가를 실시하였다. 프레스다이용 코일스프링의 파손원인은 주로 반복하중에 의한 피로파손과 일정한 변위의 변형으로 발생하는 코일스프링 자유높이의 축소로 크게 구분되어질 수 있다. 시험결과 주 파손양상은 피로에 의한 균열발생이었으며, 코일 끝단부와 끝단부 직하부의 코일과의 마찰에 의한 균열발생이 주원인이었다. 즉, 코일의 끝단면과 직하면 코일이 연속적으로 부딪침으로써 발생한 변형 및 마모에 의해 표면균열이 발생하고, 표면균열에서 반복적인 부하하중이 가해짐으로써 피로균열 진전을 통해 점차적으로 파손이 진행되어졌음을 알 수 있었다. 본 발표에서는 기준에 의거하여 로하중용 프레스 다이용 코일스프링을 평가한 신뢰성평가시험 결과에 대해 보고하고, 파단면 관찰과 외산제품과의 미세조직 및 조성 등의 비교분석결과 등을 기초로 파손원인을 분석한 결과에 대해 보고하고자 한다.제고할 수 있을 것으로 기대한다.X>$CdCl^+,\;CdSO_4$ 등이 형성되었다. 수은의 경우는 해수 및 증류수를 용출용매로 이용한 모든 경우에서 납, 구리, 카드뮴과는 달리 대부분 침전하였다. 더욱이 해수에 존재하는 고농도 염소($Cl^-$)와의 수착으로 인해 finite solid인 calomel($Hg_2Cl_2$)이 형성되어 대부분 침전(SI=0)되기 때문에 납, 구리, 카드뮴 보다 더 낮은 환경이동성을 갖을 것으로 사료된다. 상기 실험결과 용출용매로 증류수와 해수를 이용했을 때, 제강 슬래그에서 용출되는 납, 구리, 카드뮴, 수은의 용출 경향의 차이를 확인할 수 있었고 이에 따라서, 납, 구리, 카드뮴의 용출 유해성은 낮기 때문에 해양구조물로의 제강슬래그 유효이용은 적합할 것으로 판단되었다.im80%$로 계산되었다. 열형광선량계로 측정된 방사선량은 각각 1.8, 1.2, 0.8, 1.2, 0.8 (70 cm 거리) cGy로 측정되었으며, 환자의 복부 표면에서의 서베이메터를 이용한 측정량은 10.9 mR/h였다. 차폐구조물의 사용 시 전체 치료 동안에 태아선량은 약 1 cGy 정도로 평가되었다. 결론 : AAPM Report No.50의 자료에 따르면, 임산부의 방사선 치료 시 태아의 방사선 피폭선량은 5 cGy 이하일 경우에 방사선 피폭에 따른 태아의 위험이 거의 없는 것으로 제시되고 있다. 본원에서 차폐 구조물을 설치하였을 경우에 측정된 태아선량은 약 1 cGy로 측정되었고, 고안된 차폐구조물

  • PDF