• Title/Summary/Keyword: RR 간격

Search Result 48, Processing Time 0.031 seconds

The Detection of PVC based Rhythm Analysis and Beat Matching (리듬분석과 비트매칭을 통한 조기심실수축(PVC) 검출)

  • Jeon, Hong-Kyu;Cho, Ik-Sung;Kwon, Hyeog-Soong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.11
    • /
    • pp.2391-2398
    • /
    • 2009
  • Premature ventricular contractions are the most common of all arrhythmias and may cause more serious situation in some patients. Therefore, the detection of this arrhythmia becomes crucial in the early diagnosis and prevention of possible life threatening cardiac diseases. Most of the algorithms detecting PVC reported in literature is not always feasible due to the presence of noise and P wave making the detection difficult, and the process being time consuming and ineffective for real time analysis. To solve this problem, a new approach for the detection of PVC is presented based rhythm analysis and beat matching in this paper. For this purpose, the ECG signals are first processed by the usual preprocessing method and R wave was detected. The algorithm that decides beat type using the rhythm analysis of RR interval and beat matching of QRS width is developed. The performance of R wave and PVC detection is evaluated by using MIT-BIH arrhythmia database. The achieved scores indicate sensitivity of 99.74%, positive predictivity of 99.81% and sensitivity of 93.91%, positive predictivity of 96.48% accuracy respectively for R wave and PVC detection.

PVC Classification based on QRS Pattern using QS Interval and R Wave Amplitude (QRS 패턴에 의한 QS 간격과 R파의 진폭을 이용한 조기심실수축 분류)

  • Cho, Ik-Sung;Kwon, Hyeog-Soong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.4
    • /
    • pp.825-832
    • /
    • 2014
  • Previous works for detecting arrhythmia have mostly used nonlinear method such as artificial neural network, fuzzy theory, support vector machine to increase classification accuracy. Most methods require accurate detection of P-QRS-T point, higher computational cost and larger processing time. Even if some methods have the advantage in low complexity, but they generally suffer form low sensitivity. Also, it is difficult to detect PVC accurately because of the various QRS pattern by person's individual difference. Therefore it is necessary to design an efficient algorithm that classifies PVC based on QRS pattern in realtime and decreases computational cost by extracting minimal feature. In this paper, we propose PVC classification based on QRS pattern using QS interval and R wave amplitude. For this purpose, we detected R wave, RR interval, QRS pattern from noise-free ECG signal through the preprocessing method. Also, we classified PVC in realtime through QS interval and R wave amplitude. The performance of R wave detection, PVC classification is evaluated by using 9 record of MIT-BIH arrhythmia database that included over 30 PVC. The achieved scores indicate the average of 99.02% in R wave detection and the rate of 93.72% in PVC classification.

Cardiovascular response to surprise stimulus (놀람 자극에 대한 심혈관 반응)

  • Eom, Jin-Sup;Park, Hye-Jun;Noh, Ji-Hye;Sohn, Jin-Hun
    • Science of Emotion and Sensibility
    • /
    • v.14 no.1
    • /
    • pp.147-156
    • /
    • 2011
  • Basic emotions such as happiness, sadness, anger, fear, and disgust have been widely used to investigate emotion-specific autonomic nervous system activity in many studies. On the contrary, surprise emotion, Suggested also as one of the basic emotions suggested by Ekman et al. (1983), has been least investigated. The purpose of this study was to provide a description of cardiovascular responses on surprise stimulus using electrocardiograph (ECG) and photoplethysmograph (PPG). ECG and PPG were recorded from 76 undergraduate students, as they were exposed to a visuo-acoustic surprise stimulus. Heart rate (HR), standard deviation of R-R interval (SD-RR), root mean square of successive R-R interval difference (RMSSD-RR), respiratory sinus arrhythmia (RSA), finger blood volume pulse amplitude (FBVPA), and finger pulse transit time (FPTT) were calculated before and after the stimulus presentation. Results show significant increase in HR, SD-RR, and RMSSD-RR, decreased FBVPA, and shortened FPTT. Evidence suggests that surprise emotion can be characterized by vasoconstriction and accelerated heart rate, sympathetic activation, and increased heart rate variability, parasympathetic activation. These results can be useful in developing an emotion theory, or profiling surprise-specific physiological responses, as well as establishing the basis for emotion recognition system in human-computer interaction.

  • PDF

Interpolation Technique to Improve the Accuracy of RR-interval in Portable ECG Device (휴대형 심전계 장치의 RR 간격의 정확도 개선을 위한 보간법 개발)

  • Lee, Eun-Mi;Hong, Joo-Hyun;Cha, Eun-Jong;Lee, Tae-Soo
    • Journal of Biomedical Engineering Research
    • /
    • v.31 no.4
    • /
    • pp.316-320
    • /
    • 2010
  • HRV(Heart rate variability) analysis parameter is widely used as an index to evaluate the autonomic nervous system and cardiac function. For reliable HRV analysis, we need to acquire the accurate ECG signals. Most of commercially available portable ECG devices have low sampling rate because of low power consumption and small size issues, which make it difficult to measure RR-interval accurately. This study is to improve the accuracy of RR-interval by developing R-wave interpolation technique, based on the morphological characteristics of the QRS complex. When the developed method was applied to ECG obtained at 200 Hz and the results were compared with 1000 Hz reference device, the error range decreased by 1.33 times in sitting and by 2.38 times in cycling exercise. Therefore, the proposed interpolation technique is thought to be useful to improve the accuracy of R-R interval in the portable ECG device with low sampling rate.

Premature Contraction Arrhythmia Classification through ECG Pattern Analysis and Template Threshold (ECG 패턴 분석과 템플릿 문턱값을 통한 조기수축 부정맥분류)

  • Cho, Ik-sung;Cho, Young-Chang;Kwon, Hyeog-soong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.2
    • /
    • pp.437-444
    • /
    • 2016
  • Most methods for detecting arrhythmia require pp interval, diversity of P wave morphology, but it is difficult to detect the p wave signal because of various noise types. Therefore it is necessary to use noise-free R wave. In this paper, we propose algorithm for premature contraction arrhythmia classification through ECG pattern analysis and template threshold. For this purpose, we detected R wave through the preprocessing method using morphological filter, subtractive operation method. Also, we developed algorithm to classify premature contraction wave pattern using weighted average, premature ventricular contraction(PVC) and atrial premature contraction(APC) through template threshold for R wave amplitude. The performance of R wave detection, PVC classification is evaluated by using 6 record of MIT-BIH arrhythmia database that included over 30 PVC and APC. The achieved scores indicate the average of 99.77% in R wave detection and the rate of 94.91%, 95.76% in PVC and APC classification.

Feature Extraction based on Auto Regressive Modeling and an Premature Contraction Arrhythmia Classification using Support Vector Machine (Auto Regressive모델링 기반의 특징점 추출과 Support Vector Machine을 통한 조기수축 부정맥 분류)

  • Cho, Ik-sung;Kwon, Hyeog-soong;Kim, Joo-man;Kim, Seon-jong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.2
    • /
    • pp.117-126
    • /
    • 2019
  • Legacy study for detecting arrhythmia have mostly used nonlinear method to increase classification accuracy. Most methods are complex to process and manipulate data and have difficulties in classifying various arrhythmias. Therefore it is necessary to classify various arrhythmia based on short-term data. In this study, we propose a feature extraction based on auto regressive modeling and an premature contraction arrhythmia classification method using SVM., For this purpose, the R-wave is detected in the ECG signal from which noise has been removed, QRS and RR interval segment is modelled. Also, we classified Normal, PVC, PAC through SVM in realtime by extracting four optimal segment length and AR order. The detection and classification rate of R wave and PVC is evaluated through MIT-BIH arrhythmia database. The performance results indicate the average of 99.77% in R wave detection and 99.23%, 97.28%, 96.62% in Normal, PVC, PAC classification.

Optimal Parameter Extraction based on Deep Learning for Premature Ventricular Contraction Detection (심실 조기 수축 비트 검출을 위한 딥러닝 기반의 최적 파라미터 검출)

  • Cho, Ik-sung;Kwon, Hyeog-soong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.12
    • /
    • pp.1542-1550
    • /
    • 2019
  • Legacy studies for classifying arrhythmia have been studied to improve the accuracy of classification, Neural Network, Fuzzy, etc. Deep learning is most frequently used for arrhythmia classification using error backpropagation algorithm by solving the limit of hidden layer number, which is a problem of neural network. In order to apply a deep learning model to an ECG signal, it is necessary to select an optimal model and parameters. In this paper, we propose optimal parameter extraction method based on a deep learning. For this purpose, R-wave is detected in the ECG signal from which noise has been removed, QRS and RR interval segment is modelled. And then, the weights were learned by supervised learning method through deep learning and the model was evaluated by the verification data. The detection and classification rate of R wave and PVC is evaluated through MIT-BIH arrhythmia database. The performance results indicate the average of 99.77% in R wave detection and 97.84% in PVC classification.

Parameter Extraction for Based on AR and Arrhythmia Classification through Deep Learning (AR 기반의 특징점 추출과 딥러닝을 통한 부정맥 분류)

  • Cho, Ik-sung;Kwon, Hyeog-soong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.10
    • /
    • pp.1341-1347
    • /
    • 2020
  • Legacy studies for classifying arrhythmia have been studied in order to improve the accuracy of classification, Neural Network, Fuzzy, Machine Learning, etc. In particular, deep learning is most frequently used for arrhythmia classification using error backpropagation algorithm by solving the limit of hidden layer number, which is a problem of neural network. In order to apply a deep learning model to an ECG signal, it is necessary to select an optimal model and parameters. In this paper, we propose parameter extraction based on AR and arrhythmia classification through a deep learning. For this purpose, the R-wave is detected in the ECG signal from which noise has been removed, QRS and RR interval is modelled. And then, the weights were learned by supervised learning method through deep learning and the model was evaluated by the verification data. The classification rate of PVC is evaluated through MIT-BIH arrhythmia database. The achieved scores indicate arrhythmia classification rate of over 97%.

The Hurst Exponent of RR Intervals in MCG Heartbeat Time Series (MCG 시계열 신호에서 RR간격 분석)

  • Lee, Hyoung;Min, Joon-Young;Lee, In-Jung
    • Journal of Information Technology Applications and Management
    • /
    • v.12 no.4
    • /
    • pp.25-31
    • /
    • 2005
  • We know that the Hurst Exponent (HE) is a real number in [0, 1] which denotes randomness of time series. in this research, we suggest non-linear analysis of human biological signals through HE. The feasibility of human biological signals using inductive incitement provides Some diagnosis for active treatment. In our experiment, we measured the heartbeat through the MCG, 29 healthy and 34 abnormal subjects ostensibly. The raw data of acupuncture incitement are supported by opinions of gross examination and pathological diagnosis. The mean values of HE are 0.345, 0.755 and 0.805 for the periods of before, during and after acupuncture treatment, respectively in case of abnormal subjects. On the other hand, the mean values, 0.808, 0.797 and 0.785 are for normal cases, correspondingly. From this data, we show that HE is very significant in abnormal controls according to an acupuncture incitement, and the incitement effect is evidently extracted in abnormal subjects. But, in normal subjects, the incitement effect is meaningless.

  • PDF

A Large Scale Separation & Purification of Cyanobacterial Toxins (남조류 독성물질의 대량분리 및 정제)

  • Yoon, Suk Chang;Park, Keun Young;Pyo, Dong Jin
    • Journal of the Korean Chemical Society
    • /
    • v.42 no.1
    • /
    • pp.51-56
    • /
    • 1998
  • It is very difficult to separate and purify the microcystins, cyanobacterial toxins since it exist in a trace level in natural lakes. In this paper, we developed a new analytical method to separate and purify the microcystin RR and LR from the freeze-dried cyanobacterial cells in natural lakes. We used 7.5 g silica gel as a stationary phase and ethyl acetate: isopropanol: water (30: 45: 25) as a mobile phase and microcystins were eluted using an open column. The eluting solvent was collected in a small bottle at the intervals of 3 mL and the fractions were chromatographed with HPLC to confirm the microcystin RR and LR.

  • PDF