• Title/Summary/Keyword: ROC with distance

Search Result 23, Processing Time 0.026 seconds

COMPARATIVE STUDY ON THE HORIZOTAL MEASUREMENTS OF SKELETAL CLASS III MALOCCLUSION USING THE ROC ANALYSIS (ROC 분석을 이용한 골격성 III급 부정교합의 수평계측방법간 비교연구)

  • Choi, Hee-Young;Chang, Young-Il
    • The korean journal of orthodontics
    • /
    • v.25 no.2 s.49
    • /
    • pp.153-163
    • /
    • 1995
  • In this study, Receiver Operating Characteristic(ROC) analysis was used to evaluate the ability of cephalometric measurements to identify patients with Class III malocclusions. ROC analysis is the method for determining the validity of a diagnostic measure and for evaluating the relative value of diagnostic tests. The sample consisted of 496 patients with malocclusion. Class III malocclusion is defined as the dental relationship for which The mesiobuccal groove of the lower first molar is deviated mesially from the mesiobuccal cusp of the upper first molar. Of the total sample of 496 patients, 245 had Class III malocclusions. 16 cephalometric measurements were selected, each of which was treated as a diagnostic test. The ROC curves were generated for each cephalometric measurement with intervals of $1.0^{\circ}$ for angular measurements, 1.0mm for linear measurements. The area under the ROC curves was measured for direct comparison among different diagnostic tests. The results were as follows; 1. The 'Wits' appraisal was found to be a better diagnostic criterion for the presence of Class III malocclusion than any other commonly'used cephalometric measurement. 2. AB plane angle, ANB angle, App-Bpp distance, AF-BF distance, APDI, Distance of point A and Pog to N perpendicular, maxillomandibular differential had high diagnostic value. 3. Cephalometric measurements which evaluate the position of the mandible had moderate diagnostic value. 4. Cephalometric measurements related to the maxilla discriminated least between patients with and without Class III malocclusion.

  • PDF

Image saliency detection based on geodesic-like and boundary contrast maps

  • Guo, Yingchun;Liu, Yi;Ma, Runxin
    • ETRI Journal
    • /
    • v.41 no.6
    • /
    • pp.797-810
    • /
    • 2019
  • Image saliency detection is the basis of perceptual image processing, which is significant to subsequent image processing methods. Most saliency detection methods can detect only a single object with a high-contrast background, but they have no effect on the extraction of a salient object from images with complex low-contrast backgrounds. With the prior knowledge, this paper proposes a method for detecting salient objects by combining the boundary contrast map and the geodesics-like maps. This method can highlight the foreground uniformly and extract the salient objects efficiently in images with low-contrast backgrounds. The classical receiver operating characteristics (ROC) curve, which compares the salient map with the ground truth map, does not reflect the human perception. An ROC curve with distance (distance receiver operating characteristic, DROC) is proposed in this paper, which takes the ROC curve closer to the human subjective perception. Experiments on three benchmark datasets and three low-contrast image datasets, with four evaluation methods including DROC, show that on comparing the eight state-of-the-art approaches, the proposed approach performs well.

NONPARAMETRIC MAXIMUM LIKELIHOOD ESTIMATION OF A CONCAVE RECEIVER OPERATING CHARACTERISTIC CURVE VIA GEOMETRIC PROGRAMMING

  • Lee, Kyeong-Eun;Lim, Johan
    • Bulletin of the Korean Mathematical Society
    • /
    • v.48 no.3
    • /
    • pp.523-537
    • /
    • 2011
  • A receiver operating characteristic (ROC) curve plots the true positive rate of a classier against its false positive rate, both of which are accuracy measures of the classier. The ROC curve has several interesting geometrical properties, including concavity which is a necessary condition for a classier to be optimal. In this paper, we study the nonparametric maximum likelihood estimator (NPMLE) of a concave ROC curve and its modification to reduce bias. We characterize the NPMLE as a solution to a geometric programming, a special type of a mathematical optimization problem. We find that the NPMLE is close to the convex hull of the empirical ROC curve and, thus, has smaller variance but positive bias at a given false positive rate. To reduce the bias, we propose a modification of the NPMLE which minimizes the $L_1$ distance from the empirical ROC curve. We numerically compare the finite sample performance of three estimators, the empirical ROC curve, the NMPLE, and the modified NPMLE. Finally, we apply the estimators to estimating the optimal ROC curve of the variance-threshold classier to segment a low depth of field image and to finding a diagnostic tool with multiple tests for detection of hemophilia A carrier.

Image Evaluation of Projection Method in Chest Radiography (흉부 엑스선 촬영 시 촬영기법에 따른 영상 평가)

  • Ahn, Byung-Ju;Lee, Jun-Haeng
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.3
    • /
    • pp.217-223
    • /
    • 2022
  • In this study, images taken using a grid and images taken using Air Gap Technique were evaluated in X-ray chest radiography. Subjective Evaluation The ROC (Receiver Operating Characteristic) evaluation was evaluated by 5 radiologists who had worked for more than 10 years in the radiology department of a university hospital. Objective evaluation SNR (Signal to noise ratio) was evaluated. As a result of the analysis, the Cronbach Alpha value was 0.714, which was significantly higher. In the Air Gap Technique, the distance between the phantom and the subject was set at 20 cm, and the image was taken with a tube voltage of 100 kVp, a tube current and a recording time of 8 mAs. In the ROC (Receiver Operating Characteristic) evaluation, the highest score was obtained with 18 score and an objective evaluation SNR (signal to noise ratio) of 6,149 scored. Also, in the imaging method using a grid, when the distance between the phantom and the constant receptor is 15 cm apart, and the tube voltage is 110 kVp, the tube current and the recording time are taken at 8 mAs, the ROC evaluation score is 19 and the objective evaluation SNR (Signal to noise ratio) is the highest with 6.622 scored. Therefore, if the Air Gap Technique imaging method is used, which overcomes the shortcomings such as delay in reading, increase in patient's exposure dose, and shortening of mechanical lifespan, as well as re-radiography due to the cut-off phenomenon of the grid that appears using the grid, the It is thought that it will be very helpful for chest imaging, including the case of using a portable X-ray imaging device.

A Comparison of Urban Growth Probability Maps using Frequency Ratio and Logistic Regression Methods

  • Park, So-Young;Jin, Cheung-Kil;Kim, Shin-Yup;Jo, Gyung-Cheol;Choi, Chul-Uong
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.38 no.5_2
    • /
    • pp.194-205
    • /
    • 2010
  • To predict urban growth according to changes in landcover, probability factors werecal culated and mapped. Topographic, geographic and social and political factors were used as prediction variables for constructing probability maps of urban growth. Urban growth-related factors included elevation, slope, aspect, distance from road,road ratio, distance from the main city, land cover, environmental rating and legislative rating. Accounting for these factors, probability maps of urban growth were constr uctedusing frequency ratio (FR) and logistic regression (LR) methods and the effectiveness of the results was verified by the relative operating characteristic (ROC). ROC values of the urban growth probability index (UGPI) maps by the FR and LR models were 0.937 and 0.940, respectively. The LR map had a slightly higher ROC value than the FR map, but the numerical difference was slight, with both models showing similar results. The FR model is the simplest tool for probability analysis of urban growth, providing a faster and easier calculation process than other available tools. Additionally, the results can be easily interpreted. In contrast, for the LR model, only a limited amount of input data can be processed by the statistical program and a separate conversion process for input and output data is necessary. In conclusion, although the FR model is the simplest way to analyze the probability of urban growth, the LR model is more appropriate because it allows for quantitative analysis.

Statistical Fingerprint Recognition Matching Method with an Optimal Threshold and Confidence Interval

  • Hong, C.S.;Kim, C.H.
    • The Korean Journal of Applied Statistics
    • /
    • v.25 no.6
    • /
    • pp.1027-1036
    • /
    • 2012
  • Among various biometrics recognition systems, statistical fingerprint recognition matching methods are considered using minutiae on fingerprints. We define similarity distance measures based on the coordinate and angle of the minutiae, and suggest a fingerprint recognition model following statistical distributions. We could obtain confidence intervals of similarity distance for the same and different persons, and optimal thresholds to minimize two kinds of error rates for distance distributions. It is found that the two confidence intervals of the same and different persons are not overlapped and that the optimal threshold locates between two confidence intervals. Hence an alternative statistical matching method can be suggested by using nonoverlapped confidence intervals and optimal thresholds obtained from the distributions of similarity distances.

Utility of False Profile View for Screening of Ischiofemoral Impingement

  • Kwak, Dae-Kyung;Yang, Ick-Hwan;Kim, Sungjun;Lee, Sang-Chul;Park, Kwan-Kyu;Lee, Woo-Suk
    • Hip & pelvis
    • /
    • v.30 no.4
    • /
    • pp.219-225
    • /
    • 2018
  • Purpose: Ischiofemoral impingement (IFI)-primarily diagnosed by magnetic resonance imaging (MRI)-is an easily overlooked disease due to its low incidence. The purpose of this study was to evaluate the usefulness of false profile view as a screening test for IFI. Materials and Methods: Fifty-eight patients diagnosed with IFI between June 2013 and July 2017 were enrolled in this retrospective study. A control group (n=58) with matching propensity scores (age, gender, and body mass index) were also included. Ischiofemoral space (IFS) was measured as the shortest distance between the lateral cortex of the ischium and the medial cortex of lesser trochanter in weight bearing hip anteroposterior (AP) view and false profile view. MRI was used to measure IFS and quadratus femoris space (QFS). The receiver operating characteristics (ROC), area under the ROC curve (AUC) and cutoff point of the IFS were measured by false profile images, and the correlation between the IFS and QFS was analyzed using the MRI scans. Results: In the false profile view and hip AP view, patients with IFI had significantly decreased IFS (P<0.01). In the false profile view, ROC AUC (0.967) was higher than in the hip AP view (0.841). Cutoff value for differential diagnosis of IFI in the false profile view was 10.3 mm (sensitivity, 88.2%; specificity, 88.4%). IFS correlated with IFS (r=0.744) QFS (0.740) in MRI and IFS (0.621) in hip AP view (P<0.01). Conclusion: IFS on false profile view can be used as a screening tool for potential IFI.

Optimal Waist Circumference for the Prevention of Cardiovascular Disease (심혈관계질환의 발병 위험을 선별할 수 있는 적정 허리둘레의 임계점)

  • Baik, In-Kyung;Shin, Chol
    • Korean Journal of Community Nutrition
    • /
    • v.15 no.2
    • /
    • pp.275-283
    • /
    • 2010
  • There are few studies reporting optimal waist circumference that can be utilized to prevent the incidence of cardiovascular disease (CVD). We evaluated the association of waist circumference and waist and hip circumference ratio (WHR) with incident cases of CVD developed over 6 years in a population-based prospective study including Korean adults. Analyses for receiver-operating characteristic (ROC) curve were performed with data for 1,733 men and 1,579 women who were aged 40 to 69 years and were free of a physician-diagnosis of CVD at baseline. Information on the diagnosis of CVD was periodically reported using interviewer-administered questionnaires and anthropometric measures were obtained by biennial health examinations. We newly identified 77 cases of CVD during a follow-up period between 2003 and 2008. On the basis of measures of diagnostic accuracy including minimum distance to ROC curve and Youden index, waist circumference of 85 cm for men, in particular for male nonsmokers, and of 80 cm for women and WHR of 0.88 to 0.90 for men and of 0.83 for women were found to be optimal cutoff points to identify individuals at CVD risks. The study also found that the use of the suggested optimal values for waist circumference show higher sensitivity and lower specificity compared with 90 cm for men and 85 cm for women, which are waist cutoff points given by the Korean Society for the Study of Obesity to define abdominal obesity for Korean adults. Although lower cutoff points of waist circumference (83 cm) and WHR (0.87) were observed to be optimal for male smokers compared with male nonsmokers, whether suggesting waist cutoff points specific to smokers is needed warrants further studies. After taking into account other cardiovascular risk factors including smoking, men with waist circumference of 85 cm or greater and women with 80 cm or greater were at an increased risk of CVD. Thus, these cutoff points of waist circumference may be able to capture more individuals at CVD risks contributing to the prevention of future development of CVD.

A Study of CBIR(Content-based Image Retrieval) Computer-aided Diagnosis System of Breast Ultrasound Images using Similarity Measures of Distance (거리 기반 유사도 측정을 통한 유방 초음파 영상의 내용 기반 검색 컴퓨터 보조 진단 시스템에 관한 연구)

  • Kim, Min-jeong;Cho, Hyun-chong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.8
    • /
    • pp.1272-1277
    • /
    • 2017
  • To assist radiologists for the characterization of breast masses, Computer-aided Diagnosis(CADx) system has been studied. The CADx system can improve the diagnostic accuracy of radiologists by providing objective information about breast masses. Morphological and texture features were extracted from the breast ultrasound images. Based on extracted features, the CADx system retrieves masses that are similar to a query mass from a reference library using a k-nearest neighbor (k-NN) approach. Eight similarity measures of distance, Euclidean, Chebyshev(Minkowski family), Canberra, Lorentzian($F_2$ family), Wave Hedges, Motyka(Intersection family), and Cosine, Dice(Inner Product family) are evaluated by ROC(Receiver Operating Characteristic) analysis. The Inner Product family measure used with the k-NN classifier provided slightly higher performance for classification of malignant and benign masses than those with the Minkowski, $F_2$, and Intersection family measures.

Dimensional Stability of Bentwoods by Treatment Conditions

  • Jung, In-Suk;Lee, Weon-Hee;Chang, Jun-Pok;Bae, Hyun-Mi
    • Journal of the Korean Wood Science and Technology
    • /
    • v.30 no.3
    • /
    • pp.85-90
    • /
    • 2002
  • This study was carried out to investigate the dimensional stability of bentwoods by three treatments: steaming, urethane varnish coating, and polyethylene glycol (PEG) treatment. Bentwood processing employed a bending-jig with only 4 cm radius of curvature (ROC). The used species were bitter wood (Picrasma quassioides), painted maple (Acer mono), and birch (Betula schmidtiii). The bending properties of these are well-known in bentwood production (Jung et al., 2002). The bentwoods were treated repeated at room temperature [20℃, RH 80% (12 hours) and 40℃ under RH 10% (12 hours)]. To estimate the dimensional stability of bentwoods, we measured the radius of curvature and end-distance. The best results could be attained with PEG treatment. Steaming was the worst treatment. Comparing the properties of the different species, the dimensional stability of bitter wood was excellent. It was concluded that the steaming treatment was unsuitable for dimensional stability of bentwoods.