• Title/Summary/Keyword: ROC Curve

Search Result 593, Processing Time 0.028 seconds

Evaluation of Cancer Detection Efficiency by Means of Hybrid and Inverse Filter in Chest Radiography (디지털 흉부 방사선 영상에서 Hybrid Filter와 Inverse Filter를 적용한 종양의 검출능 평가)

  • Kim, Youn-Young;Kim, Tae-Young;Kim, Hyun-Ji;Park, Min-Seock;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.36 no.4
    • /
    • pp.319-326
    • /
    • 2013
  • The purpose of this study is to evaluate usefulness of Hybrid image and Inverse image about detection of tumor shadow in chest radiography using ROC analysis. Original images of 60 cases are selected from Standards digital image date base issued by the Japanese Society of Radiological Technology. Through computer language of C, Inverse images of 60 cases and Hybrid image of 30 cases are made. The continues reading experiment was conducted. In the case of inverse image were observed by 5 radiographer and 2 radiologist. In the case of In case of Hybrid image were observed by 3 student radiographer and 2 experienced radiographer. ROC curve are constructed using ROCKIT Program made by Metz. In Inverse image, a Az of average ROC curve was increases from 0.742 of original image to 0.775 of inverse image. In normal cases, the effect of the detrimental is same to that of the beneficial, however In abnormal cases, the beneficial effect is greater than detrimental effect. However in Hybrid image, a Az of average ROC curve was decreases from 0.5253 of original image to 0.4868 of Hybrid image. In Normal cases, the effect of the detrimental is greater than that of the Beneficial, however In abnormal cases, the Beneficial effect is greater than detrimental effect. The inverse image can be more positively considered for the detecting of tumor than the hybrid image.

Retrospective Analysis of Cytopathology using Gray Level Co-occurrence Matrix Algorithm for Thyroid Malignant Nodules in the Ultrasound Imaging (갑상샘 악성결절의 초음파영상에서 GLCM 알고리즘을 이용한 세포병리 진단의 후향적 분석)

  • Kim, Yeong-Ju;Lee, Jin-Soo;Kang, Se-Sik;Kim, Changsoo
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.237-243
    • /
    • 2017
  • This study evaluated the applicability of computer-aided diagnosis by retrospective analysis of GLCM algorithm based on cytopathological diagnosis of normal and malignant nodules in thyroid ultrasound images. In the experiment, the recognition rate and ROC curve of thyroid malignant nodule were analyzed using 6 parameters of GLCM algorithm. Experimental results showed 97% energy, 93% contrast, 92% correlation, 92% homogeneity, 100% entropy and 100% variance. Statistical analysis showed that the area under the curve of each parameter was more than 0.947 (p = 0.001) in the ROC curve, which was significant in the recognition of thyroid malignant nodules. In the GLCM, the cut-off value of each parameter can be used to predict the disease through analysis of quantitative computer-aided diagnosis.

Odds curve for two classification distributions (두 분류 분포를 위한 오즈 곡선)

  • Hong, Chong Sun;Oh, Se Hyeon;Oh, Tae Gyu
    • The Korean Journal of Applied Statistics
    • /
    • v.34 no.2
    • /
    • pp.225-238
    • /
    • 2021
  • The ROC, TOC, and TROC curves, which are visually descriptive methods of exploring the performance of the binary classification model, are implemented with TP, TN, FP, FN which consist of the confusion matrix, as well as their ratios TPR, TNR, FPR, FNR. In this study, we consider two types odds and then propose an odds curve representing these odds. And show the relationship between the odds curve and ROC curve. Based on the odds curve, we propose not only two statistics that measure the discriminant power of the odds curve but also the criteria for validation ratings of the odds curve. According to the shape of the odds curves, two classification distributions can be estimated and a criterion for validation ratings can be determined. The odds curve can be meaningfully used like other visual methods, and two kinds of measures for the discriminant power can be also applied together as an alternative criterion.

Positive and negative predictive values by the TOC curve

  • Hong, Chong Sun;Choi, So Yeon
    • Communications for Statistical Applications and Methods
    • /
    • v.27 no.2
    • /
    • pp.211-224
    • /
    • 2020
  • Sensitivity and specificity are popular measures described by the receiver operating characteristic (ROC) curve. There are also two other measures such as the positive predictive value (PPV) and negative predictive value (NPV); however, the PPV and NPV cannot be represented by the ROC curve. Based on the total operating characteristic (TOC) curve suggested by Pontius and Si (International Journal of Geographical Information Science, 97, 570-583, 2014), explanatory methods are proposed to geometrically describe the PPV and NPV by the TOC curve. It is found that the PPV can be regarded as the slope of the right-angled triangle connecting the origin to a certain point on the TOC curve, while 1 - NPV can be represented as the slope of the right-angled triangle connecting a certain point to the top right corner of the TOC curve. When the neutral zone exists, the PPV and 1-NPV can be described as the slopes of two other right-angled triangles of the TOC curve. Therefore, both the PPV and NPV can be estimated using the TOC curve, whether or not the neutral zone is present.

Bivariate ROC Curve (이변량 ROC곡선)

  • Hong, C.S.;Kim, G.C.;Jeong, J.A.
    • Communications for Statistical Applications and Methods
    • /
    • v.19 no.2
    • /
    • pp.277-286
    • /
    • 2012
  • For credit assessment models, the ROC curves evaluate the classification performance using two univariate cumulative distribution functions of the false positive rate and true positive rate. In this paper, it is extended to two bivariate normal distribution functions of default and non-default borrowers; in addition, the bivariate ROC curves are proposed to represent the joint cumulative distribution functions by making use of the linear function that passes though the mean vectors of two score random variables. We explore the classification performance based on these ROC curves obtained from various bivariate normal distributions, and analyze with the corresponding AUROC. The optimal threshold could be derived from the bivariate ROC curve using many well known classification criteria and it is possible to establish an optimal cut-off criteria of bivariate mixture distribution functions.

Standard criterion of hypervolume under the ROC manifold (ROC 다면체 아래 체적의 판단기준)

  • Hong, C.S.;Jung, D.G.
    • Journal of the Korean Data and Information Science Society
    • /
    • v.25 no.3
    • /
    • pp.473-483
    • /
    • 2014
  • Even though the ROC manifold for more than three dimensional space which is an extension of the ROC curve and surface has difficulty to represent graphically, the hypervolume under the ROC manifold (HUM) statistic can be defined and obtained based on AUC and VUS measures for the ROC curve and the ROC surface. Hence the definition and characteristics of the HUM for four dimensional space are studied in this work. By extension of the standard criterion of AUC for probabilities of default based on Basel II, the 13 classes of standard criterion of HUM are proposed in order to discriminate four classification models and some application methods are discussed. In order to explore the standard criterion of HUM whose values are obtained from various distributions, ternary plot is used and explained.

A Comparison of the Interval Estimations for the Difference in Paired Areas under the ROC Curves (대응표본에서 AUC차이에 대한 신뢰구간 추정에 관한 고찰)

  • Kim, Hee-Young
    • Communications for Statistical Applications and Methods
    • /
    • v.17 no.2
    • /
    • pp.275-292
    • /
    • 2010
  • Receiver operating characteristic(ROC) curves can be used to assess the accuracy of tests measured on ordinal or continuous scales. The most commonly used measure for the overall diagnostic accuracy of diagnostic tests is the area under the ROC curve(AUC). When two ROC curves are constructed based on two tests performed on the same individuals, statistical analysis on differences between AUCs must take into account the correlated nature of the data. This article focuses on confidence interval estimation of the difference between paired AUCs. We compare nonparametric, maximum likelihood, bootstrap and generalized pivotal quantity methods, and conduct a monte carlo simulation to investigate the probability coverage and expected length of the four methods.

Multivariate Outlier Removing for the Risk Prediction of Gas Leakage based Methane Gas (메탄 가스 기반 가스 누출 위험 예측을 위한 다변량 특이치 제거)

  • Dashdondov, Khongorzul;Kim, Mi-Hye
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.12
    • /
    • pp.23-30
    • /
    • 2020
  • In this study, the relationship between natural gas (NG) data and gas-related environmental elements was performed using machine learning algorithms to predict the level of gas leakage risk without directly measuring gas leakage data. The study was based on open data provided by the server using the IoT-based remote control Picarro gas sensor specification. The naturel gas leaks into the air, it is a big problem for air pollution, environment and the health. The proposed method is multivariate outlier removing method based Random Forest (RF) classification for predicting risk of NG leak. After, unsupervised k-means clustering, the experimental dataset has done imbalanced data. Therefore, we focusing our proposed models can predict medium and high risk so best. In this case, we compared the receiver operating characteristic (ROC) curve, accuracy, area under the ROC curve (AUC), and mean standard error (MSE) for each classification model. As a result of our experiments, the evaluation measurements include accuracy, area under the ROC curve (AUC), and MSE; 99.71%, 99.57%, and 0.0016 for MOL_RF respectively.

Image saliency detection based on geodesic-like and boundary contrast maps

  • Guo, Yingchun;Liu, Yi;Ma, Runxin
    • ETRI Journal
    • /
    • v.41 no.6
    • /
    • pp.797-810
    • /
    • 2019
  • Image saliency detection is the basis of perceptual image processing, which is significant to subsequent image processing methods. Most saliency detection methods can detect only a single object with a high-contrast background, but they have no effect on the extraction of a salient object from images with complex low-contrast backgrounds. With the prior knowledge, this paper proposes a method for detecting salient objects by combining the boundary contrast map and the geodesics-like maps. This method can highlight the foreground uniformly and extract the salient objects efficiently in images with low-contrast backgrounds. The classical receiver operating characteristics (ROC) curve, which compares the salient map with the ground truth map, does not reflect the human perception. An ROC curve with distance (distance receiver operating characteristic, DROC) is proposed in this paper, which takes the ROC curve closer to the human subjective perception. Experiments on three benchmark datasets and three low-contrast image datasets, with four evaluation methods including DROC, show that on comparing the eight state-of-the-art approaches, the proposed approach performs well.

Optimization of Predictors of Ewing Sarcoma Cause-specific Survival: A Population Study

  • Cheung, Min Rex
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.10
    • /
    • pp.4143-4145
    • /
    • 2014
  • Background: This study used receiver operating characteristic curve to analyze Surveillance, Epidemiology and End Results (SEER) Ewing sarcoma (ES) outcome data. The aim of this study was to identify and optimize ES-specific survival prediction models and sources of survival disparities. Materials and Methods: This study analyzed socio-economic, staging and treatment factors available in the SEER database for ES. 1844 patients diagnosed between 1973-2009 were used for this study. For the risk modeling, each factor was fitted by a Generalized Linear Model to predict the outcome (bone and joint specific death, yes/no). The area under the receiver operating characteristic curve (ROC) was computed. Similar strata were combined to construct the most parsimonious models. Results: The mean follow up time (S.D.) was 74.48 (89.66) months. 36% of the patients were female. The mean (S.D.) age was 18.7 (12) years. The SEER staging has the highest ROC (S.D.) area of 0.616 (0.032) among the factors tested. We simplified the 4-layered risk levels (local, regional, distant, un-staged) to a simpler non-metastatic (I and II) versus metastatic (III) versus un-staged model. The ROC area (S.D.) of the 3-tiered model was 0.612 (0.008). Several other biologic factors were also predictive of ES-specific survival, but not the socio-economic factors tested here. Conclusions: ROC analysis measured and optimized the performance of ES survival prediction models. Optimized models will provide a more efficient way to stratify patients for clinical trials.