• Title/Summary/Keyword: RMS signal

Search Result 304, Processing Time 0.025 seconds

Characteristics on Arc Waveform and RMS of Current by Conductive Powder (도전성 분말에 의한 아크전류의 파형 및 실효값 특성)

  • Kim, Doo Hyun;Kang, Yang Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.3
    • /
    • pp.63-68
    • /
    • 2013
  • This paper is aimed to make an analysis on characteristics of the parallel arc waveform and RMS of current at the electrical tracking state by conductive powder. In order to achieve the goal in this paper, field state investigation at metal processing companies in Chung-Nam province area was conducted. With the field state investigation, conductive powder were collected from metal processing companies. By experiment on electrical connector(breaker, connector) over which the conductive powder were scattered, arc waveform and RMS of current were measured. The measured waveform and RMS(root-mean-square) of current were analyzed to describe characteristics and patterns of electrical arc by the conductive powder. It was proved that conductive powder on electrical connector can flow electrical current enough to make electrical fire with high thermal energy. Also the change of sine waveform and RMS of current can be used to find out relationship between electrical fire and fault signal by conductive powder. The results obtained in this paper will be very helpful for the prevention of electrical fires occurred at the metal processing companies.

Development of Remote Diagnosis System to Accumulate Abnormal Signal Data of Transformer (변압기의 이상 신호 데이터를 축적하기 위한 원거리 진단 시스템 개발)

  • Kwak, Seung Soo;Kim, Yong Sin
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2019.07a
    • /
    • pp.161-162
    • /
    • 2019
  • 본 논문에서는 변압기의 이상 신호 데이터를 원거리에서 축적하기 위한 이상 신호 진단 시스템을 제안한다. 이 시스템은 원격으로 변압기의 이상 신호를 수집하여 변압기의 이상을 알아낼 수 있다. 이 시스템은 상용된 통신 모듈의 느린 통신 속도를 고려하여 이상 신호를 RMS-DC 값으로 변환하는 작업을 추가하였다.

  • PDF

A Study on the Detection of the Chatter Using Current Signal in Turning (선삭가공시 전류신호를 이용한 채터 검출에 관한 연구)

  • 서한원;유기현;오석형;서남석
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.947-951
    • /
    • 1997
  • Recently, the necessity of the detection of abnormal machining process is being emphasized in order to improve the machining accuracy and reduce the cost in unmanned operating system. The vibration by chatter generated in cutting processes within machine tools is a relative motion between tools and workpieces. So, if the chatter occurs, the surface roughness and accuracy of workpieces will be deteriorate and it leads to the rapid wear of tools. The author intended to use the I /sab/RMS (current of root mean square) of current sigals and the movimg C.V. (coefficient of variation) of each phase for the detection method of chatter.

  • PDF

A Study on the Linear Motor Control System (니리어모터 이송계 제어 특성분석에 관한 연구)

  • Yoo, Song-Min
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2003.04a
    • /
    • pp.466-471
    • /
    • 2003
  • In order to analyze linear motor driven feed system, preliminary studies have been conducted focusing on the performance evaluation of the system based on the various combination of control gain along with acceleration. Tentative simulation revealed that due to the complexity of control system reduced number of control condition is recommended. Actual machining process with conventional feed system using endmill tool was employed as a preliminary study. Several sensing methods including AE, acceleration sensors and tool dynamometer were used. Results revealed the consistency in AE and cutting resistance. There were inconsistent empirical results in accelerometer probably due to the insensitivity of the sensor signal with respect to the experimental system

  • PDF

NEW ADAPTIVE METHOD FOR VOLTAGE SAG AND SWELL DETECTION

  • Mohamed, Mansour A.
    • Journal of the Korea Convergence Society
    • /
    • v.4 no.1
    • /
    • pp.33-41
    • /
    • 2013
  • This paper presents an adaptive recursive least squares algorithm (ARLS) for detecting voltage sag and voltage swell events in power systems. Different methods have been developed to detect voltage sag and voltage swell. Some of them use window techniques, which are too slow when voltage sag or swell mitigation is required. Others depend on the extraction of a single non-stationary sinusoidal signal out of a given multi-components input signal, and therefore they don't consider the harmonic components in calculating the voltage root mean square value (rms). The method, proposed in this paper, is capable of estimating the voltage rms taking into account all harmonic components. The method is tested by applying it to different, simulated signals using ATP program, and compared with voltage sag detection algorithms.

Study on Evaluation of the Leak Rate for Steam Valve in Power Plant (발전용 증기밸브 누설량 평가에 관한 연구)

  • Lee, S.G.;Park, J.H.;Yoo, G.B.
    • Journal of Power System Engineering
    • /
    • v.11 no.1
    • /
    • pp.45-50
    • /
    • 2007
  • Acoustic emission technology is applied to diagnosis the internal leak and operating conditions of the major valves at nuclear power plants. The purpose of this study is to verify availability of the acoustic emission as in-situ diagnosis method. In this study, acoustic emission tests are performed when the pressurized high temperature steam flowed through gate valve(1st stage reheater valve) and glove valve(main steam dump valve) on the normal size of 4 and 8". The valve internal leak diagnosis system for practical field was designed. The acoustic emission method was applied to the valves at the site, and the background noise was measured for the abnormal plant condition. To improve the reliability, a judgment of leak on the system was used various factors which are AE parameters, trend analysis, signal level analysis and RMS(root mean square) analysis of acoustic signal emitted from the valve operating condition internal leak.

  • PDF

A Study of Tool Breakage Dection Using AE Sensor (AE(acoustic emission)센서를 이용한 공구파손검출에 관한 연구)

  • Lee, Jae-Jong;Song, Jun-Yeop;Park, Hwa-Yeong
    • 한국기계연구소 소보
    • /
    • s.19
    • /
    • pp.61-68
    • /
    • 1989
  • As the system monitoring technology become required in order to improve the system performance and the productivity, we’ve studied to the detection for the tool wear and the tool breakage using AE sensors that is able to detection of generated high frequency stress pulse at cutting. The detection system is consist of a sensing part, a amplifier part, a signal processing part, and a analysis & output part. The moment (a rms and a kurtosis) of statistical method is used for analysis of AE singnal. The experiment are carried out in a CNC lathe. In this study, we achieved that the amplitude level of the AE signal and statistical moments was largely changed as the tool failure. The change rate of Kurtosis was especially large, but the change rate of the rms was small.

  • PDF

Measurement Procedure and Analysis of Terrestrial DTV Field Test in Taejeon (대전지역의 지상파 DTV 현장 측정 및 결과 분석)

  • 김종호;조진호;이형수;박재홍
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.5
    • /
    • pp.830-838
    • /
    • 2000
  • This paper represents measurement prodcedure and analysis of terrestrial DTV field test results over Taejeon city area. Thirty three points were selected as measuring points. Signal power, noise power, Segment Error Rate, RMS delay spread and equalizer performance was measured. The video and audio quality of DTV was good over half of test sites. Equalizer, could correct signal ghost and improve S/N up to 13.7 dB. From this test, the test procedure for DTV will be estabilished.

  • PDF

A study on the Precision of RMS value calculation using Mother Wavelet (마더 웨이브렛에 따른 RMS값 계산의 정확도 검토에 관한 연구)

  • Oh, K.S.;Kim, C.H.;Park, N.O.;Lee, D.J.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.265-267
    • /
    • 2003
  • The wavelet transform(WT) has been extensively applied in solving many problems in applied science and engineering following its introduction in early 1980's. The WT analyzes a signal in a changeable frequency range by employing a moving window whereby along time window is used to obtain low frequency information and short time window is used to obtain high frequency information. In this paper, after various fault types in 154 KV transmission system was simulated by using EMTP, and the RMS values by changing Mother wavelet was calculated by applying wavelet transform to the simulated voltage and current signal.

  • PDF

The study of AC source measurement algorithm using Digital System (디지털시스템을 이용한 교류 전원 계측 알고리즘에 관한 연구)

  • Seo, Yong-Won;Kim, Yun-Seo;Yang, O
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.979-982
    • /
    • 2003
  • 본 논문은 단상 또는 3상의 AC 전원의 전류나 전압 또는 전력을 계측하기 위해 Analog Signal들을 Digital Signal로 변환하여 특정 Algorithm의 연산을 수행하여 결과를 얻는 과정을 Microprocessor를 이용하여 처리하는 방법은 산업현장이나 연구개발에서 흔히 사용하는 방법이다. 본 논문에서는 Microprocessor를 이용하여 보편화된 3가지의 계측 Algorithm인 DFT, True RMS, Summation Algorithm을 사용하여 동일 System에 3상 AC의 전류 부하를 일정 범위에서 가변 하여 인가시키면서 계측 값을 사용하여 Algorithm의 계측 결과의 오차율과 연산에 소요되는 시간과 외부 잡음인 Surge, Impulse, 정전기, 방파, 고조파에 대한 System의 처리 효율을 연구 하였다.

  • PDF