• Title/Summary/Keyword: RLSA

Search Result 5, Processing Time 0.017 seconds

Efficient Analysis of Couplings through Periodically Arranged Slots in a Radial Line Slot Antenna (RLSA 설계를 위한 주기적으로 배열된 슬롯을 통한 결합의 효율적인 해석)

  • 이중원;김용훈;박종국;남상욱
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.6
    • /
    • pp.931-939
    • /
    • 2001
  • The slot coupling characteristics was analysed in a radial-line slot antenna for its design. The previously proposed waveguide model with a periodic boundary condition on its narrow walls and periodically arranged slots on its wide wall was used. The magnetic field integral equation and two dyadic Green\`s functions for respective regions was derived and the method of moments was used. To maximize the efficiency of numerical analysis and to extract singularities, two different kinds of basis functions, the entire domain basis function and the sub-domain one, are used. In addition, the Ewald sum technique for the rectangular waveguide and the Shanks transform for the half space were used to accelerate the computation of the slowly convergent potential Green\`s functions. Simulation results expressed the effects of the various design parameters on the slot coupling.

  • PDF

A Study on the 60 GHz Band Radial Line Slot Array Antenna Fed by a Rectangular Waveguide (60 GHz 대역용 도파관 급전 Radial Line Slot Array 안테나에 관한 연구)

  • 김용훈;채희덕;이중원;박종국;김성철;김성철
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.3
    • /
    • pp.257-262
    • /
    • 2002
  • A single-layered radial line slot array (SL-RLSA) antenna etched on a substrate and fad by a rectangular waveguide is presented in the 60 ㎓ band. The design curves are obtained by an efficient electromagnetic coupling analysis using Ewald Sum technique and Shanks transformation. The antenna has rectangular waveguide feed structure using a rectangular waveguide-to-radial line transition. The prototype antenna of 10 cm-diameter was tested and the gain of 31 ㏈i and the efficiency of 38% were measured at 60 ㎓.

Local Current Distribution in a Ferromagnetic Tunnel Junction Fabricated Using Microwave Excited Plasma Method (마이크로파 여기 프라즈마법으로 제조한 강자성 터널링 접합의 국소전도특성)

  • Yoon, Tae-Sick;Kim, Cheol-Gi;Kim, Chong-Oh;Masakiyo Tsunoda;Migaku Takahashi;Ying Li
    • Journal of the Korean Magnetics Society
    • /
    • v.13 no.2
    • /
    • pp.47-52
    • /
    • 2003
  • Ferromagnetic tunnel junctions were fabricated by dc magnetron sputtering and plasma oxidation process. The local transport properties of the ferromagnetic tunnel junctions were studied using contact-mode Atomic Force Microscopy (AFM) and the local current-voltage analysis. Tunnel junctions with the structure of sub./Ta/Cu/Ta/NiFe/Cu/Mn$\_$75/Ir$\_$25//Co$\_$70/Fe$\_$30//Al-oxide were prepared on thermally oxidized Si wafers. Al-oxide layers were formed with microwave excited plasma using radial line slot antenna (RLSA) for 5 and 7 sec. Kr gas was used as the inert gas mixed with $O_2$ gas for the plasma oxidization. No correlation between topography and current image was observed while they were measured simultaneously. The local current distribution was well identified with the distribution of local barrier height. Assuming the gaussian distribution of the local barrier height, the ferromagnetic tunnel junction with longer oxidation time was well fitted with the experimental results. As contrast, in the case of the shorter time oxidation junction, the current mainly flow through the low barrier height area for its insufficient oxygen. Such leakage current might result in the decrease of tunnel magnetoresistance (TMR) ratio.

Damping of Inter-Area Low Frequency Oscillation Using an Adaptive Wide-Area Damping Controller

  • Yao, Wei;Jiang, L.;Fang, Jiakun;Wen, Jinyu;Wang, Shaorong
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.1
    • /
    • pp.27-36
    • /
    • 2014
  • This paper presents an adaptive wide-area damping controller (WADC) based on generalized predictive control (GPC) and model identification for damping the inter-area low frequency oscillations in large-scale inter-connected power system. A recursive least-squares algorithm (RLSA) with a varying forgetting factor is applied to identify online the reduced-order linearlized model which contains dominant inter-area low frequency oscillations. Based on this linearlized model, the generalized predictive control scheme considering control output constraints is employed to obtain the optimal control signal in each sampling interval. Case studies are undertaken on a two-area four-machine power system and the New England 10-machine 39-bus power system, respectively. Simulation results show that the proposed adaptive WADC not only can damp the inter-area oscillations effectively under a wide range of operation conditions and different disturbances, but also has better robustness against to the time delay existing in the remote signals. The comparison studies with the conventional lead-lag WADC are also provided.

Local Similarity based Document Layout Analysis using Improved ARLSA

  • Kim, Gwangbok;Kim, SooHyung;Na, InSeop
    • International Journal of Contents
    • /
    • v.11 no.2
    • /
    • pp.15-19
    • /
    • 2015
  • In this paper, we propose an efficient document layout analysis algorithm that includes table detection. Typical methods of document layout analysis use the height and gap between words or columns. To correspond to the various styles and sizes of documents, we propose an algorithm that uses the mean value of the distance transform representing thickness and compare with components in the local area. With this algorithm, we combine a table detection algorithm using the same feature as that of the text classifier. Table candidates, separators, and big components are isolated from the image using Connected Component Analysis (CCA) and distance transform. The key idea of text classification is that the characteristics of the text parallel components that have a similar thickness and height. In order to estimate local similarity, we detect a text region using an adaptive searching window size. An improved adaptive run-length smoothing algorithm (ARLSA) was proposed to create the proper boundary of a text zone and non-text zone. Results from experiments on the ICDAR2009 page segmentation competition test set and our dataset demonstrate the superiority of our dataset through f-measure comparison with other algorithms.