• Title/Summary/Keyword: RL

Search Result 442, Processing Time 0.024 seconds

Restless Legs Syndrome and Quality of Life in Hemodialysis Patients (혈액투석을 받는 만성신부전 환자에서 하지불안증후군과 삶의 질)

  • Choi, Hyun-Seok;Kang, Seung-Gul;Boo, Chang-Su;Lee, Heon-Jeong;Cho, Won-Yong;Kim, Hyoung-Kyu;Kim, Leen
    • Sleep Medicine and Psychophysiology
    • /
    • v.14 no.2
    • /
    • pp.99-106
    • /
    • 2007
  • Objective: Restless legs syndrome (RLS) is known to be associated with chronic renal failure (CRF) patients on hemodialysis, however the prevalence of RLS in CRF patients on hemodialysis is variable due to different diagnostic criteria or dialysis technique. A few reports have indicated the association between RLS symptom and lower life quality in CRF patients on hemodialysis. This study aims to investigate the prevalence of RLS and its association with the quality of life in CRF patients of a single dialysis unit in Korea. Methods: A total of 83 Korean CRF patients on hemodialysis in the Korea University Hospital were examined. International Restless Legs Syndrome Study Group (IRLSSG) criteria and International Restless Legs Scale (IRLS) were used to determine the diagnosis and severity of RLS. Questionnaires including Athens Insomnia Scale (AIS), Epworth sleepiness scale (ESS), and Medical Outcome Study Form-36 (SF-36) were administered to all the patients for the assessment of sleep and quality of life. Hamilton Depression Rating Scale (HDRS) and Clinical Global Impression (CGI) were also measured for depression and status of mental illness by psychiatrist. Results: Of the 83 patients, 31 (37.3%) patients were found to have RLS and 43 (51.8%) patients met at least one of the RLS diagnostic criteria. The AIS (t=2.40, p=0.019), ESS (t=2.41, p=0.018), HDRS (t=3.85, p<0.001) and CGI (t=3.52, p=0.001) were higher in the subjects with RLS compared to other subjects. The SF-36 scores were significantly lower in the patients with RLS except physical functioning and bodily pain. Total (p=0.005), physical component (p=0.019), and mental component scores (p=0.019) of SF-36 were significantly lower in patients with more severe RLS symptoms. Conclusion: There was significant relationship between RLS and poor quality of sleep and life. More severe RLS symptom was proven to be an important factor to make a quality of life worsen.

  • PDF

STUDY ON THE GROWTH OF THE MANDIBLE USING WIDE OPEN LATERAL CEPHALOGRAM (Wide open lateral cephalogram을 이용한 하악골 성장에 관한 연구)

  • Moon, Sung-Uk;Park, Young-Guk;Chung, Kyu-Rhim
    • The korean journal of orthodontics
    • /
    • v.31 no.1 s.84
    • /
    • pp.39-50
    • /
    • 2001
  • In proceeding with orthodontic treatment, the prediction for the shape, growth rate and growth direction of mandible plays a major role to set up the treatment plan and determine its period and prognosis. Various approaches being made so far have shown that the linear and angular measurement using lateral cephalograms are relatively accurate to estimate them. This study was purposed to find the shape of mandible more clearly by preventing the overlap of the Condyle head area which appears in lateral cephalogram, and to estimate its growth rate by comparing the growth quantity and ratio via lateral area measurement. This experimental was performed against 40 patients total, of which Class I of 14, Class II of 9 and Class III of 17 consist. Wide open lateral cephalograms of 40 patients were taken over average period of 4 Year 3 Months, then the linear and angular measurements were carried out with 11 itemized lists. Autocad Rl4 application program was utilized to draw their appearance, measure and compare their lateral area. As a result of study, conclusions were made as follows; 1. Mandibular body length (gonion-menton) tended to increase in order of CIII, CI and CII, and Mandibular body length of CIII group had a tendency to grow twice faster than that of CII group. 2. In lateral items such as Go-Me, A-Cd, B-Cp, E-F and G-H, CIII showed a significant increase on the year-average quantity and rate of the growth, and especially apparent difference was observed in CIII group rather than CII group. 3. For the 4 Year 3 Months period, the year-average growth quantity of lateral area of the mandible was $1.0cm^2$ for Class I, $0.8cm^2$ for Class II and $1.4cm^2$ for Class III, which corresponds to $11.9\%,\;11.8\%\;and\;20.3\%$ of growth ratio respectively. Thus, growth ratio almost 2 times more than other groups was observed in group CIII while growth ratio between group CI and CII has little difference. 4. Considering the results as above, it can be proposed that the difference in size of the mandible between groups is caused by the difference in the growth rate and growth quantity of the mandible, which generated in the middle of growth, rather than the difference in size of congenital Jaw-bone.

  • PDF

Development of a split beam transducer for measuring fish size distribution (어체 크기의 자동 식별을 위한 split beam 음향 변환기의 재발)

  • 이대재;신형일
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.37 no.3
    • /
    • pp.196-213
    • /
    • 2001
  • A split beam ultrasonic transducer operating at a frequency of 70 kHz to use in the fish sizing echo sounder was developed and the acoustic radiation characteristics were experimentally analyzed. The amplitude shading method utilizing the properties of the Chebyshev polynomials was used to obtain side lobe levels below -20 dB and to optimize the relationship between main beam width and side lobe level of the transducer, and the amplitude shading coefficient to each of the elements was achieved by changing the amplitude contribution of elements with 4 weighting transformers embodied in the planar array transducer assembly. The planar array split beam transducer assembly was composed of 36 piezoelectric ceramics (NEPEC N-21, Tokin) of rod type of 10 mm in diameter and 18.7 mm in length of 70 kHz arranged in the rectangular configuration, and the 4 electrical inputs were supplied to the beamformer. A series of impedance measurements were conducted to check the uniformity of the individual quadrants, and also in the configurations of reception and transmission, resonant frequency, and the transmitting and receiving characteristics were measured in the water tank and analyzed, respectively. The results obtained are summarized as follows : 1. Average resonant and antiresonant frequencies of electrical impedance for four quadrants of the split beam transducer in water were 69.8 kHz and 83.0 kHz, respectively. Average electrical impedance for each individual transducer quadrant was 49.2$\Omega$ at resonant frequency and 704.7$\Omega$ at antiresonant frequency. 2. The resonance peak in the transmitting voltage response (TVR) for four quadrants of the split beam transducer was observed all at 70.0 kHz and the value of TVR was all about 165.5 dB re 1 $\mu$Pa/V at 1 m at 70.0 kHz with bandwidth of 10.0 kHz between -3 dB down points. The resonance peak in the receiving sensitivity (SRT) for four combined quadrants (quad LU+LL, quad RU+RL, quad LU+RU, quad LL+RL) of the split beam transducer was observed all at 75.0 kHz and the value of SRT was all about -177.7 dB re 1 V/$\mu$Pa at 75.0 kHz with bandwidth of 10.0 kHz between -3 dB down points. The sum beam transmitting voltage response and receiving senstivity was 175.0 dB re 1$\mu$Pa/V at 1 m at 75.0 kHz with bandwidth of 10.0 kHz, respectively. 3. The sum beam of split beam transducer was approximately circular with a half beam angle of $9.0^\circ$ at -3 dB points all in both axis of the horizontal plane and the vertical plane. The first measured side lobe levels for the sum beam of split beam transducer were -19.7 dB at $22^\circ$ and -19.4 dB at $-26^\circ$ in the horizontal plane, respectively and -20.1 dB at $22^\circ$ and -22.0 dB at $-26^\circ$ in the vertical plane, respectively. 4. The developed split beam transducer was tested to estimate the angular position of the target in the beam through split beam phase measurements, and the beam pattern loss for target strength corrections was measured and analyzed.

  • PDF

The Study of Shielding Effect on Ovoids of Three Different Gynecological Applicator Sets in microSelectron-HDR System (microSelectron-HDR System에서 부인암 강내조사에 쓰이는 세 가지 Applicator Set들의 Ovoids에 대한 차폐효과 연구)

  • Cho, Young-K.;Park, Sung-Y.;Choi, Jin-H.;Kim, Hung-J.;Kim, Woo-C.;Loh, John-J.K.;Kim, Joo-Y.
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.4
    • /
    • pp.259-266
    • /
    • 1998
  • There are three different types of gynecological applicator sets available in microSelectron-high dose-rate(HDR) System by Nucletron; standard applicator set(SAS), standard shielded applicator set(SSAS), and Fletcher-Williamson applicator set(FWAS). Shielding effect of a SAS without shielding material was compared with that of a SSAS with shielding material made of stainless steel(density ${\varrho}=8,000kg/m^3$) at the top and bottom of each ovoid, and of a FWAS with shielding material made of tungsten alloy(density ${\varrho}=14,000kg/m^3$ at the top and bottom of each ovoid. The shielding effects to the rectum and bladder of these two shielded applicator sets were to be measured at reference points with an ion chamber and specially designed supporting system for applicator ovoids inside of the computerized 3-dimensional water phantom. To determine the middle point of two ovoids the measurement was performed with the reference tip of ion chamber placed at the same level and at the middle point from the two ovoids, while scanning the dose with the ion chamber on each side of ovoids. The doses to the reference points of rectum were measured at 20(Rl), 25(R2), 30(R3), 40(R4), 50(R5), and 60(R6) mm located posteriorly on the vertical line drawn from M5(the middle dwell position of ovoid), and the doses to the bladder were measured at 20(Bl), 30(B2), 40(B3), 50(B4), and 60(B5) mm located anteriorly on the vertical line drawn from M5. The same technique was employed to measure the doses on each reference point of both SSAS and FWAS. The differences of measured rectal doses at 25 mm(R2) and 30 mm(R3) between SAS and SSAS were 8.0 % and 6.0 %: 25.0% and 23.0 % between SAS and FWAS. The differences of measured bladder doses at 20 mm(Bl) and 30 mm(B2) between SAS and SSAS were 8.0 % and 3.0 %: 23.0 % and 17.0 % between SAS and FWAS. The maximum shielding effects to the rectum and bladder of SSAS were 8.0 % and 8.0 %, whereas those of FWAS were 26.0 % and 23.0 %, respectively. These results led to the conclusion that FWAS has much better shielding effect than SSAS does, and when SSAS and FWAS were used for gynecological intracavitary brachytherapy in microSelectron-HDR system, the dose to the rectum and bladder was significantly reduced to optimize the treatment outcome and to lower the complication rates in the rectum and bladder.

  • PDF

Stress and Relective Index of ${SiN}_{x}$ and ${SiN}_{x}/\textrm{SiO}_{x}/{SiN}_{x}$ Films as Membranes of Micro Gas Sensor (Micro Gas Sensor의 Membrane용 ${SiN}_{x}$막과 ${SiN}_{x}/\textrm{SiO}_{x}/{SiN}_{x}$막의 응력과 굴절율)

  • Lee, Jae-Seok;Sin, Seong-Mo;Park, Jong-Wan
    • Korean Journal of Materials Research
    • /
    • v.7 no.2
    • /
    • pp.102-106
    • /
    • 1997
  • Micro gas sensors including thin film catal) tic type require stress-free memhrancs for etch stop of Si anisotropic etching and sublayer of sensing elements hecause stress is one of the main factors affecting breakdown of thin membranes. This paper reports the effects of deposition conditions on stress and refractive index of $SiN_{x}/SiO_{x}/(NON)$ films deposited by low pressure c11ernic;rl vapor deposition(L, t'CVI)) 2nd reactve sputtering. In the case of I.PCVI1, the stresses of $SiN_{x}$ and NON films arc $7.6{\times}10^{8}dyne/cm^2$ and $3.3{\times}10^{8}dyne/cm^2$, respectibely, and the refractive indices are 3.05 and 152, respectively. In the cxse oi the sputtered SiN, , compressi\e stress decreased in magnitude and then turned to tensility as increasing proc, ess pressure by lmtorr to 30mtorr and cicreasmg applied power density by $2.74W/cm^2$ to $1.10W/cm^2$. The hest value of film stress obt;~ined under condition of lOmtorr and $1.37W/cm^2$ in this' experiment was $1.2{\times}10^{9}dyne/cm^2$ cnnipressive. The refr~ict~ve index decreased from 2 05 to 1 89 as decreasing applied power density by lnitorr to 3Orntorr and increasing process pressure hy $2.74W/cm^2$ to $1.10W/cm^2$. Stresses of films deposited by both LPCVL) and sputtering decreased as incre;lsing temperature and showed plastic behavior as decreasing temperature.

  • PDF

Investigations on data-driven stochastic optimal control and approximate-inference-based reinforcement learning methods (데이터 기반 확률론적 최적제어와 근사적 추론 기반 강화 학습 방법론에 관한 고찰)

  • Park, Jooyoung;Ji, Seunghyun;Sung, Keehoon;Heo, Seongman;Park, Kyungwook
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.25 no.4
    • /
    • pp.319-326
    • /
    • 2015
  • Recently in the fields o f stochastic optimal control ( SOC) and reinforcemnet l earning (RL), there have been a great deal of research efforts for the problem of finding data-based sub-optimal control policies. The conventional theory for finding optimal controllers via the value-function-based dynamic programming was established for solving the stochastic optimal control problems with solid theoretical background. However, they can be successfully applied only to extremely simple cases. Hence, the data-based modern approach, which tries to find sub-optimal solutions utilizing relevant data such as the state-transition and reward signals instead of rigorous mathematical analyses, is particularly attractive to practical applications. In this paper, we consider a couple of methods combining the modern SOC strategies and approximate inference together with machine-learning-based data treatment methods. Also, we apply the resultant methods to a variety of application domains including financial engineering, and observe their performance.

Effects of Several Medicinal Plants Extract on Survival Rate, Chlorophyll Contents and Photosynthetic Electron Transport Activity of Liverwort Photoautotrophic Cultured Cell (약용식물 추출액이 우산이끼 자가관양배양세포의 생존율, 엽록소함량 및 광합성전자전달 활성에 미치는 영향)

  • 정형진;권순태;김시무
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.40 no.2
    • /
    • pp.133-141
    • /
    • 1995
  • The effects of allelochemicals from medicinal plants have been studied as photo-synthetic inhibitor for photoautotrophic(PA) cultured cells. The extracts from 9 plant species were used for measuring the physiological effects on the liverwort cultured cell in following areas; germination inhibition, chlorophyll contents, hill activity, cell viability, photosynthetic oxygen evolution,and protein pattern changes on SDS PAGE. Germination inhibitions were detected in all plant after treating with 10% extract. Especially, treatment with 10% extract from Pulsatilla koreana and Aconitum carmichael inhibited germinations completely. Chlorophyll fornation was inhibited completely by treating PA cells with extract of Pulsatilla koreana, whose effect was similar to that of DCMU 10-3M, inhibitor for photosynthetic electron trans-fer. The treatment with extract from Pulsatilla koreana on PA cell showed the highest hill activity and the lowest cell viability among extracts studied. Oxygen releasing has been decreased down to 14-77% after treating with extracts from Pinellia ternata, Araliacont inentaila, Pulsatilla koreana and Vitex rotundifolia. Especially, 60$\mu$l of Pulsatilla koreana extract into 2ml mixture of PA cell inhibit-ed oxygen release up to 50%. Protein bands on SDS-PAGE, 14kD, 31kD, 41kD, 53kD, and 73kD, were not detected after treating Pulsatilla koreana extract on PA cells.

  • PDF

A Simulation of Temperature Control of Greenhouse with Hot-Water Heating System (온수난방시스템 온실의 온도제어 시뮬레이션)

  • 정태상;하종규;민영봉
    • Journal of Bio-Environment Control
    • /
    • v.8 no.3
    • /
    • pp.152-163
    • /
    • 1999
  • It is required to analyze the controlled response of air temperature in greenhouse according to control techniques for precise control. In this study, a mathematical model was established for air heating of greenhouse with hot-water heating system The parameters of the model were decided by regression analysis using reference data measured at the greenhouse being heated In the simulation for the digital control of air temperature in the greenhouse, the mathematical model to evaluate the control performances was used. Tested control methods were ON-OFF contpol, p control, rl control and PID control. The mathematical model represented by inside air temperature ( T$_{i}$), hot-water temperature (T$_{w}$) in heating pipe and outside air temperature (T$_{o}$) was expressed as a following discrete time equation ; T$_{i}$($textsc{k}$+1)= 0.851.T$_{i}$($textsc{k}$)+0.055.T$_{w}$($textsc{k}$)+0.094.T$_{o}$($textsc{k}$) Control simulations for various control methods showed the settling time, the overshoot and the steady state nor as follows; infinite time, 3.5$0^{\circ}C$, 3.5$0^{\circ}C$ for ON-OFF control : 30min 2.37$^{\circ}C$, 0.51$^{\circ}C$ for P control; 21min, 0.0$0^{\circ}C$, 0.23$^{\circ}C$ for PI control; 18min 0.0$0^{\circ}C$, 0.23$^{\circ}C$ for PID control, respectively. PI and PID controls appeared to be optimal control methods. There was no effect of differential gain on the heating process but much effect of integral gain on it.on it.

  • PDF

Rapid Gas Chromatographic Screening of Dairy Products for Volatile and Nonvolatile Organic Acids (기체크로마토그래피법에 의한 유제품내 휘발성 및 비휘발성 유기산의 신속한 스크리닝)

  • Kim, Jung-Han;Kim, Kyoung-Rae;Chai, Jeong-Young;Oh, Chang-Hwan;Park, Hyung-Kook;Choi, Kyoung-Sook
    • Korean Journal of Food Science and Technology
    • /
    • v.26 no.6
    • /
    • pp.665-669
    • /
    • 1994
  • A rapid gas chromatographic (GC) profiling method was applied to dairy products (milk and cheeses) for the simultaneous analysis of volatile and nonvolatile organic acids. Cheese samples were first made into aqueous samples by dissolving in water. The aqueous samples were then extracted with organic solvents after the acidification and NaCI saturation. The organic layers (diethyl ether : hexane= 1 : 1) were extracted with $NaHCO_3$ saturated solution with subsequent solid-phase extraction of the aqueous phases using Chromosorb P column/diethyl ether followed by triethylamine treatment. The resulting triethylammonium salts of acids were directly converted into volatile tert.-butyldimethylsilyl derivatives, which were analyzed by dual-capillary column GC, and GC-mass spectrometry. From milk and four cheese samples studied, 31 organic acids including 21 fatty acids and other hydroxy and dioic acids were tentatively identified. The amounts of the fatty acids were different among the kinds of cheese and thus the simplified retention index (RI) spectra of organic acids were useful for the visual pattern recognition of each sample, when the Direct Comparision method between cheese and a blind sample were attempted, it was quickly recognized to be a gouda cheese with the 999 ppt match quality value.

  • PDF

Changes in the Luminal Surface of the PTFE Graft used in Systemic- pulmonary Shunt Operation (체폐단락술에 사용되었던 PTFE 인조혈관 내면의 변화)

  • Park, Yeong-Hwan;Jang, Byeong-Cheol;Sin, Dong-Hwan;Jo, Beom-Gu
    • Journal of Chest Surgery
    • /
    • v.29 no.8
    • /
    • pp.836-843
    • /
    • 1996
  • Histologic, and scanning electron microscopic observa ions were made of 12 biopsy specimens from polytetrdiluoroethylene (PTFE) grafts that had been Implanted as systemic-pulmonAry shunt for improving oxygenation of cyanotic congenital heart disease and harvested near the end of pulmonary artery side at the time of redo shunt or tonal correction between 1985 and 1992. The types of shunt operation are modified Blalock-Taussig shunt in 10 cases, Waterston-Cooley shunt in 1 And Potts shunt in 1 case. The 5 mm PTFE graft was used In 10, 4mm in 1 and 6mm in 1 case. The mean duration of implantalion was 0 $\pm$ 14.1 months(rl.on 12 months to 55 months). The plAtelets were aggregated between gaps'of Coretex surface and intimal thickening was noted about 10 to 20 months after implantation. Endothelial cells were found in the 40-months patent PTFE graft by light and scanning electron microscopy. In the specimen of poor flow or zero flow graft, severe intimal hyperplasia and thrombi which was made of platelets were noted . Based on this experience, we think that the patency will be maintained well if the connective tissue could be Hxed firmly over the Inner layer of the Goretex and the endothelial cell layer sllould form over the con- nective tissue and platelet aggregation should be prevented.

  • PDF