• Title/Summary/Keyword: RIIC

Search Result 2, Processing Time 0.015 seconds

A Read-In Integrated Circuit for IR Scene Projectors Adopting a Sub-Frame Control Technique for Minimizing the Temperature Loss (온도 손실의 최소화를 위해 Sub-Frame 제어 기법을 적용한 적외선 영상 투사기용 신호입력회로)

  • Shin, Uisub;Cho, Min Ji;Kang, Woo Jin;Jo, Young Min;Lee, Hee Chul
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.8
    • /
    • pp.113-118
    • /
    • 2016
  • In this paper, a read-in integrated circuit (RIIC) for IR scene projectors (IRSPs) adopting a sub-frame control technique is proposed, which minimizes the reduction of the apparent temperature of the IR images projected from IRSPs operating at a frame rate of 30 Hz. The proposed sub-frame control technique significantly reduces the amount of scene data loss on capacitors, which is caused by leakage currents flowing through MOSFET switches during holding periods, by dividing a unit frame into 8 sub-frames and refreshing the same scene data for each sub-frame. A current-drive RIIC was designed for the higher apparent temperature of IR radiated from the emitter, and it receives the scene data as a form of analog voltages from an external DAC. A prototype chip with a $64{\times}32$ RIIC array was fabricated using Magnachip/SKhynix $0.35{\mu}m$ 2-poly 4-metal CMOS process, and the measured maximum output data current is $230.3{\mu}A$. This amount of current ensures the projection of IR images whose maximum apparent temperature is $366.2^{\circ}C$ in the mid-wavelength IR (MWIR) when applied to a prototype emitter having a resistance of $15k{\Omega}$.

AN INFRA-RED SPECTROPHOTOMETRIC STUDY OF THE REACTION IN CALCIUM HYDROXIDE DENTAL CEMENT (치과용(齒科用) 수산화(水酸化)칼슘 시멘트의 경화반응(硬化反應)에 관(關)한 적외선분석학적(赤外線分析學的) 연구(硏究))

  • Kim, Choong-Jong;Min, Byung-Soon;Choi, Ho-Young;Park, Sang-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.10 no.1
    • /
    • pp.71-83
    • /
    • 1984
  • The purpose of this study was to evaluate the transmission spectrum of the set calcium hydroxide dental cement (Dycal, L.D. Caulk Co. Milford, Del.) Cement was prepared for A T R spectra at a low powder-to-liquid ratio of 3.0gm/ml in order to retard the reaction and facilitate the manipulation of loading the cement into the cell. Spectra were recorded on an I R Spectrophotometer (MX-1, FT) at an agle of incidence of 55. The A T R cell was a RIIc Model TR5 with a hemisperical KRS-5 (Thallium-Bromide-Iodide). A spectrum was recorded within 3 minutes. Further spectra were recorded after 5,10,30 minutes and 1,5,24, 72 hours. The results were as follows; 1. The setting reaction between acid paste and base past would take place fastly within 10 minutes after mix, and that would be slow until 72 hours after mix. 2. In the set cements, some methyl salicylate and calcium hydroxide remained unreacted until 72 hours after mix. 3. The setting reaction and the reaction rate occuring at the surface and in the bulk cements were similar. 4. The chelates were bound together between calcium hydroxide and methyl salicylate.

  • PDF