• Title/Summary/Keyword: RGP 콘택트렌즈 피팅

Search Result 7, Processing Time 0.02 seconds

Comparison of preference and Empirical Fit Success Rates for Spheric and Aspheric RGP Lenses (구면 및 비구면 디자인 RGP 콘택트렌즈의 선호도와 경험적 피팅 성공률 비교)

  • Kim, Jai-Min;Kim, Soo-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.2
    • /
    • pp.9-16
    • /
    • 2008
  • To assess the preference and efficacy of empirical fitting methods with spheric and aspheric RGP lenses. Methods: Healthy 37 subjects were fitted with spheric design (diameter 9.3 mm) on right eye and aspheric design (dia 9.6 mm) on the left eye. Base curves which were fitted empirically (using on-K, Kavg-0.50D (or 1.00D) and manufacturer's recommended fitting guide) were compared with another base curve which obtained the best diagnostic fit with spheric and aspheric RGP lenses. The preference and fitting type (lid attachment or interpalpebral) for two design lenses were investigated 2 weeks after fitting RGP lenses. Results: Of 33 successful RGP lens-wearing subjects, 76% preferred spheric design compared with 24% of aspheric RGP lens wearers. Sixty seven percent were fitted with lid-attachment in spheric lenses, whereas 64% were fitted with lid-attachment in aspheric lenses. The acceptable fit success rates within ${\pm}$0.50D of base curves were 97% for the on-K fit, 100% for the Kavg-0.50D fit and 100% of the manufacturer's guide fit compared with the diagnostic fit in spheric design, whereas 91%, 79% and 94% reported on-K, Kavg-1.00D and manufacturer's guide, respectively, in aspheric design. Conclusions: Although aspheric RGP lenses are more popular in the Korean market, it is still preferable to fit subjects with spheric RGP lenses. Empirical fitting may be best accomplished with the spheric lenses using Kavg-0.50D fit and the manufacturer's fitting guide, whereas aspheric RGP lens designs are unacceptable lens fit based on empirical fitting.

  • PDF

A Study on the Change of Corneal Refractive Power before and after Wearing RGP Contact Lenses by Flat Fitting and Alingment Fitting with Diagnostic Method (RGP 콘택트렌즈의 진단적 피팅법에 의한 플랫한 피팅과 얼라인먼트 피팅 착용 전·후 각막 굴절력의 변화에 관한 연구)

  • Lee, Dae-Won;Kim, In-Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.2
    • /
    • pp.163-169
    • /
    • 2014
  • Purpose: This study is for compared the change of corneal refractive power before and after wearing of rigid gas permeable contact lense with diagnostic method which is 1 D flatter than alignment fitting on right eye and alignment fitting on left eye for 2 months and investigate the preference. Methods: Twenty middle school and high school students (40 eyes) who had never worn a contact lense before for no corneal topographical change, no ocular disease, no experience of ophthalmic surgery and have normal tear amount were selected for this study and corneal refractive power were examined before wearing rigid gas permeable contact lense and adaptation status and corneal examination were performed after 10 days of wearing and after cheking up the continuation of wearing, all candidate wear contact lens 8 hours per day for 2 month and corneal refractive power were compared. Results: After 2 months of wearing with 1 D flatter than the alignment fitting on right eyes, there was significant difference in the central corneal refractive power was $43.84{\pm}1.33D$, flat K power was $43.05{\pm}1.29D$, and steep K power was $44.61{\pm}1.42D$ decreased than before wearing (p<0.001, 0.001, 0.047). The e-value of the principal meridians also shows statistically significant difference (p=0.037, 0.015). After 2 months of wearing with alignment fitting on left eyes, the central corneal refractive power was $44.40{\pm}1.26D$, flat K power was $43.57{\pm}1.23D$. and flat K e-value was $0.58{\pm}0.05$ which showed no statistically significant difference (p = 0.769, 0.614, 0.181). But steep K power was $45.25{\pm}1.36$, and steep K e-value was $0.45{\pm}0.18$ which shows statistically significant difference (p=0.018, 0.027). Conclusions: Consider the comfort, clear vision, dryness for preference fitting investment, 6 students (30%) prefer right eye which is 1 D flatter fitting, 14 students (70%) prefer left eye which is alignment fitting. For rigid gas permeable fitting needed for accurate examination and should prescribe the alignment fitting which is suitable for each cornea.

A Comparison of the Contact Areas between Cornea and RGP Lenses by Fitting Status (피팅 상태에 따른 RGP 렌즈와 각막과의 간극 비교)

  • Park, Eun Hye;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.3
    • /
    • pp.255-264
    • /
    • 2012
  • Purpose: In this study, the effect of lens fitting status on the contact area between spherical/aspherical RGP lens and the cornea having different astigmatic degree and corneal type was investigated for guiding the proper selection of RGP lens. Methods: Spherical and aspherical RGP lenses were applied on ninety eyes $(25.12{\pm}3.52years)$ having with-the-rule astigmatism by different fitting status. Then, their central, mid-peripheral and peripheral areas of fluorescein pattern were calculated and compared for the quantitative evaluation of the contact area between spherical/aspherical RGP lens. Results: The central and peripheral areas with the alignment fitting was significant different based on lens design. However, the central area didn't show any significant difference by lens design and corneal type when fitted in steep or flat. When analyzed by the corneal shape, both lenses with alignment and flat fitting had significant difference in central and peripheral areas. However, the central, mid-peripheral and peripheral areas with steep fitting didn't show the difference by corneal types. When analyzed by the astigmatic degree, the central and peripheral areas with alignment fitting changed proportionally to the increase of corneal astigmatism regardless of corneal shape. With steep and flat fitting, however, the central, mid-peripheral and/or peripheral areas in round- and symmetric bowtie-typed corneas showed the conflicting result when compared to those of alignment fitting when analyzed by the astigmatic degree. Conclusions: In this study, it was confirmed that the contact areas of cornea and RGP lens fitted steep and flat status were largely affected by the corneal type and corneal astigmatism rather than RGP lens fitted in alignment status. Also, this result commonly occurred in both spherical and aspherical RGP lenses.

A Study on Prescription of RGP Contact Lens in Korean Optometrist (안경사의 RGP콘택트렌즈 처방 실태조사)

  • Kim, Young-Hoon;Baarg, Saangbai;Kim, Kwang-Bae;Kim, Dae-Hyoun;Lim, Byung-Kwan;Sun, Kyoung-Ho
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.3
    • /
    • pp.7-17
    • /
    • 2007
  • There has been an increase in rigid gas permeable contact lens prescription by the optometrists in Korea since 1995. Therefore, the aim of our study was to find out which equipment is needed for adequate RGP contact lens prescription and the level of the clinical knowledge that they have and the level of education for the patient, to seize about the extended lens education programmes for the Korean optometrist. Also, we tried to figure out the problem that they had in the RGP contact lens prescription, to develope the educational programs for students and to improve legal uncertainties, through this research. The result came out with the following through questionnaires of 400 male and female opticians who is in clinical field. The distributions of respondents are 270 male (67.5%), 130 female (32.5%), and 356 optometry major (89%). We found out the optometry-majored people had faster clinical lens prescriptions (p=0.000), 72.5% of opticians prescribe the RGP-Lenses, and 27.5% do not because of laking in experience (P=0.000). They responded that they need slit-lamp, button lamp, fluorescein dry paper, and etc,for prescription or fitting test. In regular-check-up (Follow-up), the result came out very low by 83% of respondents who are not getting it regularly. And 83.5% (334 people) of them wanted to have those Extended Educational Programs and also the Clinical Education Programs.

  • PDF

The Effects of Corneal Type and Corneal Astigmatism on Tear Volume between Rigid Gas Permeable Lens and the Cornea (각막형상 및 각막난시도가 RGP렌즈와 각막사이의 눈물양에 미치는 영향)

  • Kim, Jihye;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.2
    • /
    • pp.141-150
    • /
    • 2015
  • Purpose: In the present study, a difference in tear volume between the cornea and the rigid gas permeable (RGP) lens relative to corneal shape and corneal astigmatism was investigated by the alignment fitting status of spherical and aspherical RGP lenses. Methods: Spherical and aspherical RGP lenses were fitted with alignment in 77 subjects (135 eyes) who were in their 20~30s. Tear volume stained with fluorescein was qualitatively analyzed by dividing cornea into center, mid-peripheral and peripheral parts. Results: For the spherical RGP lens fitting, tear volume differences were found in each part in all corneal types. For the aspherical RGP lens fitting, tear volume differences were in each corneal part in symmetric bow tie- and asymmetric bow tie-type corneas. However, the tear was equally distributed from the center to the peripheral part in round- and oval-type corneas. In the group with corneal astigmatism lower than 1.25 D, tear volume between center and peripheral parts, and mid-peripheral and peripheral parts, was different when a spherical RGP lens was fitted. However, tear volume in each part was not different in the group with corneal astigmatism over 1.50 D. Moreover, the tear volumes of the central and mid-peripheral parts were proportionally increased with increasing corneal astigmatism in both spherical and aspherical RGP lenses. Furthermore, aspherical RGP lenses showed greater increments than spherical RGP lenses. Conclusions: The results revealed that the difference in tear volume between aspherical RGP lens and cornea was less than spherical RGP lens, and the difference in tear volume varied according to corneal shape and astigmatism. In addition, the method of measuring relative tear volume between RGP lens and cornea that was established in the present study can be used to evaluate tear volume between contact lens and cornea.

A Study on a Changed Power of Tear lens at Spherical RGP lens Fitting (구면 RGP렌즈 Fitting시 누액렌즈 굴절력 변화에 대한 연구)

  • Park, Seong-Jong;Joo, Seok-Hee;Jung, Ju-Hyun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.2
    • /
    • pp.455-462
    • /
    • 2004
  • In this paper, we measured and analysised the power change of tear lens for 85 patients - 170 myopia eyes - who are fitted using RGP lens, considering the BGR of RGP lens, the corneal astigmatism power, and corneal curvature. We got the following results from these experiments; 1. When the BCR of RGP lens changes, the diopters of tear lens of "on-k", 0.05Pt, 01.0Ft, 0.05St, and 0.10St are -0.25D, -0.46D, -0.63D, +0.07D, and +0.26D, respectively. 2. When the corneal astigmatism power changes, the diopters of tear lens of group below 0.75D, group of 1.00D~1.25D, group of 1.50D~1.75D, and group over 2.00D in "on-k" state, are -0.25D, -0.18D, -0.09D, and -0.39D, respectively. 3. When the corneal astigmatism power changes and the BCR of test lens is changed by 0.05mm step, the change values of tear lens diopter for 0.05St and 0.05Ft approximate to ${\pm}0.25D$, while these for 0.10St and 0.10Ft don't approximate to the value below ${\pm}0.25D$.[are irregular value below ${\pm}0.25D$.] 4. When the corneal curvature and the HCR of RGP lens change, the diopters of tear lens of group below 7.50mm, group of 7.55~7.80mm, group of 7.85~8.20mm, and group over 8.25mm in "on-k" state, are -0.40D, -0.11D, -0.20D, and -0.19D, respectively. 5. When the BCR of test lens is changed by 0.05mm step and the corneal curvature increases, the change values of tear lens diopter decrease, while these over 8.25mm are mean value ${\pm}0.17D$ and the value below ${\pm}0.25D$.

  • PDF

The Effects of Spherical and Aspherical RGP Contact Lenses on Visual Performance (구면 및 비구면 RGP 콘텍트렌즈가 시력의 질에 미치는 영향)

  • Kim, Soo-Hyun;Kim, Hyun Jung;Kim, Jai-Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.1
    • /
    • pp.31-38
    • /
    • 2009
  • Purpose: This study was to evaluate corneal topography, contrast sensitivity and ocular response of a RGP, back surface aspherical contact lens compared with a spherical contact lens. Methods: A total 37 subjects were fitted with a spherical lens in right eye and an aspherical in the left eye and were evaluated for changes in corneal topography and contrast sensitivity over a 2-month period. Results: Thirty-four of 37 subjects completed the 2-month study. The corneal topography did not show differences between spherical and aspherical RGP lenses. The eyes fitted with the aspherical lenses demonstrated a greater reduction in contrast sensitivity compared with their spherical counterparts under photopic condition. Subjects preferred comfort and ocular responses provided by the spherical lens. Conclusions: Corneal topography when comparing spherical and back surface aspherical RGP lenses did not show any significant difference in the subjects. Spherical RGP lens yields better contrast sensitivity and preference than aspherical RGP lens at photopic condition. Further investigation of aberrations induced by contact lens design is warranted to explain the observed differences in visual performance.

  • PDF